Blood Flow Resistance (blood + flow_resistance)

Distribution by Scientific Domains


Selected Abstracts


Slit-flow ektacytometry: Laser diffraction in a slit rheometer

CYTOMETRY, Issue 1 2005
Sehyun Shin
Abstract Background Deformability of red blood cells (RBCs) is a determinant of blood flow resistance as RBCs pass through small capillaries of the microcirculation. Available techniques for measuring RBC deformability often require a washing process after each measurement, which is not optimal for day-to-day clinical use. Methods A laser diffraction technique has been combined with slit-flow rheometry, which shows significant advances in ektacytometric design, operation, and data analysis. The essential features of this design are its simplicity (ease of operation and no moving parts) and a disposable element that is in contact with the blood sample. Results With slit ektacytometry, the deformation of RBCs subjected to continuously decreasing shear stress in a slit flow can be quickly measured with extremely small quantities of blood. The measurements with the slit ektacytometer were compared with those of LORCA and a strong correlation was apparent. The deformability of the hardened RBCs was markedly lower than that of the normal RBCs. In addition, the young cells showed higher values of the elongation index than did the old cells. Conclusions The newly developed slit ektacytometer can measure RBC deformability with ease and accuracy. In addition, the slit ektacytometer can be easily used in a clinical setting owing to the incorporation of a disposable element that holds the blood sample. © 2005 Wiley-Liss, Inc. [source]


Maternal and fetal microvasculature in sheep placenta at several stages of gestation

JOURNAL OF ANATOMY, Issue 3 2010
Shireen A. Hafez
Abstract Maternal and fetal microvasculature was studied in ewes at days 50, 90 and 130 of gestation using microvascular corrosion casting and scanning electron microscopy. Microvascular corrosion casts of caruncles at day 50 were cup-shaped with a centrally located cavity. Branches of radial arteries entered the caruncle from its base and ramified on the maternal surface of the caruncle. Stem arteries broke into an extensive mesh of capillaries forming crypts on the fetal surface. The architecture of the caruncle at day 90 was similar to what was found at day 50 but the vascularity and the depth of the crypts increased in correspondence to increased branching of fetal villi. The substance of the caruncle was thicker at day 130 compared with day 50, with no remarkable difference compared with day 90. Capillary sinusoids of irregular form and diameter were observed on the fetal surface of the caruncle at all stages. These sinusoids may reduce blood flow resistance and subsequently increase transplacental exchange capacity. A microvascular corrosion cast of the cotyledon was cup-shaped with wide and narrow sides. Cotyledonary vessels entered and left the cotyledon from the narrow side. A cotyledonary artery gave proximal collateral branches immediately after entering the cotyledon and then further branched to supply the remaining portion of the cotyledon. Vessel branches broke into a mesh of capillaries forming the fetal vascular villi. Fetal villi that were nearest to the center of the cotyledon were the longest. Capillaries forming villi were in the form of a web-like mesh, were irregular in size and had sinusoidal dilations. The architecture of the cotyledon at day 90 was similar to day 50, but the vascularity increased. Branching of the fetal villi became more abundant. This extensive branching presumably allows a higher degree of invasion and surface contact to maternal tissues. At day 130, the distal portions of the fetal villi showed low ridges and troughs to increase the surface area for diffusion. Branching of fetal villi appears to influence the elaboration of maternal crypts in all stages of gestation. However, correspondence between crypts and villi is restricted to distal portions of fetal villi. [source]


Effect of Aging on the Structure and Function of Skeletal Muscle Microvascular Networks

MICROCIRCULATION, Issue 4 2006
SHAWN E. BEARDEN
ABSTRACT Humans are active creatures, yet physical activity and activity tolerance decline over the life span. One prevailing theme in the literature to account for a portion of the reduced activity tolerance with aging is the observation that the capacity to augment blood flow to skeletal muscle may be impaired with advancing age. This dysfunction may be due to adaptations in the structure or function of their microvascular networks, which collectively determine blood flow resistance. The intent of this review is to present the current knowledge of structure and function of microvascular networks from skeletal muscle with special regard to how these may adapt to, or persist through, the aging process. Skeletal muscles are supplied by an intricate branching network of arterioles and venules. The consistency of findings among available studies suggests that the overall arteriolar and venular network branching topology establishes early in development and varies little, if at all, over the life span. Microvascular networks are not a series of functionally isolated segmental branches. Rather, these networks transmit and communicate vasomotor signals along their lengths and among their branches. Current evidence suggests that aging is associated with a decrement in the capacity of upstream vessels to respond to downstream vasodilation and signals transmitted cell-to-cell along the vascular wall. [source]


Development of Silicone Rubber Hollow Fiber Membrane Oxygenator for ECMO

ARTIFICIAL ORGANS, Issue 11 2003
Tadashi Motomura
Abstract:, Silicone rubber hollow fiber membrane produces an ideal gas exchange for long-term ECMO due to nonporous characteristics. The extracapillary type silicone rubber ECMO oxygenator having an ultrathin hollow fiber membrane was developed for pediatric application. The test modules were compared to conventional silicone coil-type ECMO modules. In vitro experiments demonstrated a higher O2 and CO2 transfer rate, lower blood flow resistance, and less hemolysis than the conventional silicone coil-type modules. This oxygenator was combined with the Gyro C1E3 centrifugal pump, and three ex vivo experiments were conducted to simulate pediatric V-A ECMO condition. Four day and 6 day experiments were conducted in cases 1 and 2, respectively. Case 3 was a long-term experiment up to 2 weeks. No plasma leakage and stable gas performances were achieved. The plasma free hemoglobin was maintained within a normal range. This compact pump-oxygenator system in conjunction with the Gyro C1E3 centrifugal pump has potential for a hybrid total ECMO system. [source]