| |||
Blood Flow Rate (blood + flow_rate)
Selected AbstractsRole of shear stress on nitrite and NOS protein content in different size conduit arteries of swineACTA PHYSIOLOGICA, Issue 2 2009X. Guo Abstract Aim:, Inherent fundamental difference exists among arteries of different sizes. The purpose of this study was to evaluate the relation between regional difference of wall shear stress (WSS) in various sizes arteries and contents of nitrite and NO synthase (NOS) isoforms. Methods:, Five different conduit arteries in a wide range of diameter (1,8 mm) were examined in the hind limbs of 13 pigs. Blood flow rate and outer diameter were measured in vivo to determine WSS. Arterial tissues were harvested for the measurement of nitrite and NOS protein contents. The concentration of nitrite, a product of NO synthesis, was determined by high-performance liquid chromatography method. Western blot analysis was used to assess the protein contents of endothelial NOS (eNOS), inducible NOS (iNOS) and neuronal NOS (nNOS). Results:, Our data show that WSS increases with a decrease in artery diameter. Nitrite level increases with increasing WSS and hence decreases with artery diameter. The eNOS protein contents decrease with an increase in diameter. No significant difference for iNOS and nNOS protein contents was found with different artery diameter. A significant positive correlation between tissue nitrite and eNOS protein contents was also observed. Finally, the WSS-normalized eNOS is not significantly different in various size vessels. Conclusion:, Regional difference in blood flow has no effect on iNOS and nNOS protein contents in these conduit arteries. Regional difference in eNOS expression and nitrite contents may be related to the WSS-induced NO by the endothelium under normal physiological conditions. [source] On-Pump Beating Heart Versus Hypothermic Arrested Heart Valve Replacement SurgeryJOURNAL OF CARDIAC SURGERY, Issue 2 2008Ümit Karadeniz M.D. Methods: Fifty valvular surgery patients were randomly assigned into three groups. Sixteen patients underwent beating heart valve replacement with normothermic bypass without cross-clamping the aorta, 17 patients underwent the same procedure with cross-clamping the aorta and retrograde coronary sinus perfusion, and the remaining 17 patients had conventional surgery with hypothermic bypass and cardioplegic arrest. Results: Two-channel electroencephalography (EEG) was recorded to assess changes in cerebral cortical synaptic activity and 95% spectral edge frequency values were recorded continuously. Bispectral monitoring was used to measure the depth of anesthesia. Blood flow rates in middle cerebral artery (MCA) were measured by transcranial Doppler (TCD). Reduction in spectral edge frequency (>50%) or bispectral index (BIS) (<20) or transcranial Doppler flow velocity (>50%) was detected in four patients in Group 1, five patients in Group 2, and three patients in Group 3. BIS or EEG values never reached zero, which indicates isoelectric silence during surgery. Gross neurological examinations were normal in all patients postoperatively. Conclusion: There is no difference regarding neurological monitoring results between on-pump beating heart and hypothermic arrested heart valve replacement surgery. Also no significant difference was encountered among the groups regarding the clinical outcomes. [source] Prediction of hemodialysis sorbent cartridge urea nitrogen capacity and sodium release from in vitro testsHEMODIALYSIS INTERNATIONAL, Issue 2 2008Benjamin P. ROSENBAUM Abstract In sorbent-based hemodialysis, factors limiting a treatment session are urea conversion capacity and sodium release from the cartridge. In vitro experiments were performed to model typical treatment scenarios using various dialyzers and 4 types of SORBÔ sorbent cartridges. The experiments were continued to the point of column saturation with ammonium. The urea nitrogen removed and amount of sodium released in each trial were analyzed in a multi-variable regression against several variables: amount of zirconium phosphate (ZrP), dialysate flow rate (DFR), simulated blood flow rate (BFR), simulated patient whole-body fluid volume (V), initial simulated patient urea concentration (BUNi), dialyzer area permeability (KoA) product, initial dialysate sodium and bicarbonate (HCO3i) concentrations, initial simulated patient sodium (Nai), pH of ZrP, creatinine, breakthrough time, and average urea nitrogen concentration in dialysate. The urea nitrogen capacity (UNC) of various new SORBÔ columns is positively related to ZrP, BFR, V, BUNi, and ZrP pH and negatively to DFR with an R2adjusted=0.990. Two models are described for sodium release. The first model is related positively to DFR and V and negatively to ZrP, KoA product, and dialysate HCO3i with an R2adjusted=0.584. The second model incorporates knowledge of initial simulated patient sodium (negative relationship) and urea levels (negative relationship) in addition to the parameters in the first model with an R2adjusted=0.786. These mathematical models should allow for prediction of patient sodium profiles and the time of column urea saturation based on simple inputs relating to patient chemistries and the dialysis treatment. [source] A study of the extracorporeal rate of blood flow and blood pressure during hemodialysisHEMODIALYSIS INTERNATIONAL, Issue 4 2007Hariprasad S. TRIVEDI Abstract Hemodynamic instability is a common problem during hemodialysis (HD). The effect of blood flow rate (BFR) on blood pressure (BP) during HD has not been previously evaluated. Subjects receiving HD for the treatment of renal failure were enrolled (n=34). For each patient, during the last hour of 2 consecutive HD sessions the BFR was set at 200 mL/min for 30 min and at 400 mL/min for 30 min, during which period the fluid removal rate was kept constant. The order of the BFR alterations was randomized. The study procedure was repeated during the next HD session but with reversal of the order of the altered BFR. During each 30-min period, BP was recorded at baseline and subsequently every 10 min. During the BFR of 400 mL/min, subjects had a higher systolic BP by an average of 4.1 mmHg compared with the BFR of 200 mL/min (95% confidence interval [CI] 0.22,7.98; p=0.038). Similarly, during the BFR of 400 mL/min, subjects had a higher diastolic BP by an average of 3.04 mmHg compared with the BFR of 200 mL/min (95% CI 0.55,5.53; p=0.017). Likewise, during the BFR of 400 mL/min, subjects had a higher mean arterial pressure by an average of 3.44 mmHg (95% CI 0.77,6.11; p=0.012). The findings suggest that during HD, BPs are maintained higher at higher BFRs as compared with lower BFRs. [source] Efficacy and safety of DALI LDL-apheresis at high blood flow rates: A prospective multicenter studyJOURNAL OF CLINICAL APHERESIS, Issue 4 2003T. Wendler Abstract Direct adsorption of lipids (DALI) is the first LDL-apheresis method compatible with whole blood. Usually, the blood flow rate is adjusted at 60,80 ml/min, which results in session times of about 2 hr. The present study was performed to test the safety and efficacy of low-density lipoprotein cholesterol (LDL-C) and lipoprotein (a) [Lp(a)] removal by DALI at high blood flow rates in order to reduce treatment time. Thirteen chronic DALI patients in seven centers suffering from hypercholesterolemia (LDL-C 162 ± 42 mg/dl at baseline) and coronary artery disease were treated on a weekly or biweekly basis by DALI apheresis. The blood flow rate QB was held constant for at least two sessions, respectively, and was increased from 60 to 80, 120, 160, 200, and 240 ml/min. All patients had pre-existing av-fistulas. The anticoagulation was performed by a heparin bolus plus ACD-A at a ratio of citrate: blood ranging from 1:20 to 1:90. Clinically, the sessions were well tolerated and only 26/201 sessions (12%) of the treatments were fraught with minor adverse events. Acute LDL-C reductions (derived from LDL-C levels determined by lipoprotein electrophoresis) averaged 72/66/60/53/50/48% for QB = 60/80/120/160/200/240 ml/min. Lp(a) reductions were 68/67/62/60/58/56%, whereas HDL-C losses were ,10%. Routine blood chemistries and blood cell counts remained in the normal range. Treatment times averaged 142/83/45 min at Qb = 60/120/240 ml/min. On average, DALI LDL-apheresis could be performed safely and effectively at high blood flow rates up to at least 120 ml/min in patients with good blood access, which significantly reduced treatment time from 142 to 83 min (,42%). J. Clin. Apheresis 18:157,166, 2003. © 2003 Wiley-Liss, Inc. [source] Prospective investigation of a subcutaneous, implantable central venous access device for therapeutic plasma exchange in adults with neurological disordersJOURNAL OF CLINICAL APHERESIS, Issue 1 2002Basilio Pertiné Abstract Standard alternatives to antecubital access for long-term therapeutic plasma exchange, including percutaneous polyurethane or tunneled silicone catheters, are associated with complications and inconvenience for the patient. We have investigated the Bard CathLink® 20, a subcutaneously implantable central venous access device, as an alternative for outpatient plasma exchange. The CathLink® 20 consists of a funnel-shaped titanium port connected to a soft polyurethane-derived catheter and is accessed percutaneously using an 18-gauge catheter-over-needle Angiocath®. Six patients with paraproteinemic polyneuropathies underwent 64 outpatient plasma exchanges using the CathLink® 20 for access, 31 using 2 CathLink® 20's (draw and return), 20 using a single CathLink® 20 as the draw site and 13 using a single CathLink® 20 as the return site. Mean (± SD) plasma removed was 3,680 ± 551 ml in 115.2 ± 25.3 min. Apheresis personnel were able to access the ports in 1.23 ± 0.6 attempts per port per procedure. Six of 70 planned procedures were aborted: 3 because of failure of an antecubital access site and 3 because of catheter occlusion resolved using a thrombolytic agent. Whole blood flow rate was approximately 54 ml/min, and plasma flow rate was about 32 ml/min for 135 min. Access pressures were stable at ,150 to ,200 torr (P = 0.1395). Return line pressures varied between 90 and 130 torr (P = 0.0147). No patient required hospitalization during the study. Though not optimized for apheresis, the CathLink® 20 provides a reasonable option for chronic apheresis patients who lack adequate peripheral venous access. J. Clin. Apheresis 17:1,6, 2002. © 2002 Wiley-Liss, 2002. [source] Pharmacokinetics of drugs in rats with diabetes mellitus induced by alloxan or streptozocin: comparison with those in patients with type I diabetes mellitusJOURNAL OF PHARMACY AND PHARMACOLOGY: AN INTERNATI ONAL JOURNAL OF PHARMACEUTICAL SCIENCE, Issue 1 2010Joo H. Lee Abstract Objectives In rats with diabetes mellitus induced by alloxan (DMIA) or streptozocin (DMIS), changes in the cytochrome P450 (CYP) isozymes in the liver, lung, kidney, intestine, brain, and testis have been reported based on Western blot analysis, Northern blot analysis, and various enzyme activities. Changes in phase II enzyme activities have been reported also. Hence, in this review, changes in the pharmacokinetics of drugs that were mainly conjugated and metabolized via CYPs or phase II isozymes in rats with DMIA or DMIS, as reported in various literature, have been explained. The changes in the pharmacokinetics of drugs that were mainly conjugated and mainly metabolized in the kidney, and that were excreted mainly via the kidney or bile in DMIA or DMIS rats were reviewed also. For drugs mainly metabolized via hepatic CYP isozymes, the changes in the total area under the plasma concentration,time curve from time zero to time infinity (AUC) of metabolites, AUCmetabolite/AUCparent drug ratios, or the time-averaged nonrenal and total body clearances (CLNR and CL, respectively) of parent drugs as reported in the literature have been compared. Key findings After intravenous administration of drugs that were mainly metabolized via hepatic CYP isozymes, their hepatic clearances were found to be dependent on the in-vitro hepatic intrinsic clearance (CLint) for the disappearance of the parent drug (or in the formation of the metabolite), the free fractions of the drugs in the plasma, or the hepatic blood flow rate depending on their hepatic extraction ratios. The changes in the pharmacokinetics of drugs that were mainly conjugated and mainly metabolized via the kidney in DMIA or DMIS rats were dependent on the drugs. However, the biliary or renal CL values of drugs that were mainly excreted via the kidney or bile in DMIA or DMIS rats were faster. Summary Pharmacokinetic studies of drugs in patients with type I diabetes mellitus were scarce. Moreover, similar and different results for drug pharmacokinetics were obtained between diabetic rats and patients with type I diabetes mellitus. Thus, present experimental rat data should be extrapolated carefully in humans. [source] Evaluation of the anti-vascular effects of combretastatin in rodent tumours by dynamic contrast enhanced MRINMR IN BIOMEDICINE, Issue 2 2002Ross J. Maxwell The anti-vascular effects of the tubulin binding agent, disodium combretastatin A-4 3- O -phosphate (CA-4-P), have been investigated in the rat P22 carcinosarcoma by measurements of radiolabelled iodoantipyrine uptake and dynamic contrast-enhanced MRI. The iodoantipyrine estimates of absolute tumour blood flow showed a reduction from 0.35 to 0.04,ml g,1 min,1 6,h after 10,mg kg,1 CA-4-P and to <0.01,ml g,1 min,1 after 100,mg kg,1. Tumour blood flow recovered to control values 24,h after 10,mg kg,1 CA-4-P, but there was no recovery by 24,h after the higher dose. Dynamic contrast-enhanced MR images were obtained at 4.7 T, following injection of 0.1,mmol kg,1 Gd-DTPA and analysed assuming a model arterial input function. A parameter, Ktrans, which is related to blood flow rate and permeability of the tumour vasculature to Gd-DTPA, was calculated from the uptake data. Ktrans showed a reduction from 0.34 to 0.11 min,1 6,h after 10,mg kg,1 CA-4-P and to 0.07 min,1 after 100,mg kg,1. Although the magnitude of changes in Ktrans was smaller than that in tumour blood flow, the time course and dose-dependency patterns were very similar. The apparent extravascular extracellular volume fraction, ,e, showed a four-fold reduction 6,h after 100,mg kg,1 CA-4-P, possibly associated with vascular shutdown within large regions of the tumour. These results suggest that Ktrans values for Gd-DTPA uptake into tumours could be a useful non-invasive indicator of blood flow changes induced by anti-vascular agents such as combretastatin. Copyright © 2002 John Wiley & Sons, Ltd. [source] Matching Efficacy of Online Hemodiafiltration in Simple Hemodialysis ModeARTIFICIAL ORGANS, Issue 12 2008Detlef H. Krieter Abstract PUREMA H (referred to as PES) is an innovative dialysis membrane for enhanced low-molecular-weight (LMW) protein removal. The purpose of the study was to prove whether its efficacy in hemodialysis (HD) matches that of online hemodiafiltration (HDF) with conventional high-flux membranes. In a prospective, randomized, cross-over study on eight maintenance dialysis patients, treatment efficacy of HD with PES was compared with online postdilution HDF with the two synthetic high-flux membranes polysulfone (referred to as PSU) and Polyamix (referred to as POX). Apart from the infusion of replacement fluid, which was set at 20% of the blood flow rate of 300 mL/min, operating conditions in HD and HDF were kept identical. Small solute and LMW protein plasma clearances as well as the reduction ratio (RR) of cystatin C and retinol-binding protein were not different between the therapies. HDF with POX resulted in a significantly lower myoglobin RR as compared with HD with PES, and HDF with PSU. A 4% higher beta2 -microglobulin RR was determined in HDF with PSU (73 ± 5%) as compared with PES in HD (69 ± 5%). The albumin loss was below 1 g for all treatments. Despite the fact that simple HD did not fully exploit the characteristics of PES, it achieved essentially similar LMW protein removal and albumin loss as compared with online postdilution HDF with the conventional synthetic high-flux membranes PSU and POX. Therefore, HD with PES may have beneficial effects on the outcome of maintenance dialysis patients similar to high-efficiency HDF. [source] Gender differences in ondansetron pharmacokinetics in ratsBIOPHARMACEUTICS AND DRUG DISPOSITION, Issue 7 2008Si H. Yang Abstract It has been reported that ondansetron is primarily metabolized via hepatic CYP2D and 3A1/2 in male Sprague,Dawley rats, and CYP2D1 and 3A2 are male dominant and male specific isozymes, respectively, in rats. Thus, it could be expected that the pharmacokinetics of ondansetron would be changed in male rats compared with those in female rats. Thus, gender-different ondansetron pharmacokinetics were evaluated after its intravenous or oral administration at a dose of 8 mg/kg to male and female Sprague,Dawley rats. After intravenous administration of ondansetron to male rats, the AUC and time-averaged non-renal clearance (Clnr) of the drug were significantly smaller (22.6% decrease) and faster (27.3% increase), respectively, than those in female rats. This probably could be due to faster hepatic blood flow rate in male rats. After oral administration of ondansetron to male rats, the AUC of the drug was also significantly smaller (58.8% decrease) than that in female rats, and this could have been due mainly to increased intestinal metabolism of ondansetron in addition to increased hepatic metabolism of the drug in male rats. Copyright © 2008 John Wiley & Sons, Ltd. [source] Effect of macrolide antibiotics on uptake of digoxin into rat liverBIOPHARMACEUTICS AND DRUG DISPOSITION, Issue 3 2007Suwako Ito Abstract The objective of this study was to examine the effect of macrolide antibiotics, clarithromycin, erythromycin, roxithromycin, josamycin and azithromycin, on the hepatic uptake of digoxin. The uptake of [3H]digoxin was studied in rats in vivo, using the tissue-sampling single-injection technique, and in isolated rat hepatocytes in vitro. The uptake of [3H]digoxin into rat hepatocytes was concentration-dependent with a Michaelis constant (Km) of 445 nM. All the macrolide antibiotics inhibited the uptake of [3H]digoxin into rat hepatocytes in a concentration-dependent manner. However, clarithromycin did not affect the in vivo hepatic uptake of digoxin in rats. The in vivo permeability,surface area product of digoxin for hepatic uptake (PSinf) was estimated to be 12.5 ml/min/g liver from the present in vitro data, which is far larger than the hepatic blood flow rate (1.4 ml/min/g liver). Macrolide antibiotics at clinically relevant concentrations inhibit digoxin uptake by rat hepatocytes in vitro, but not in vivo, probably because hepatic uptake of digoxin in rats is blood flow-limited. Clinically observed digoxin,macrolide interaction in humans could be due to macrolide inhibition of hepatic digoxin uptake, if the uptake is permeation-limited. Copyright © 2007 John Wiley & Sons, Ltd. [source] Intra- and extrarenal arteries exhibit different profiles of contractile responses in high glucose conditionsBRITISH JOURNAL OF PHARMACOLOGY, Issue 8 2008K Nobe Background and purpose: The renal artery (RA) has been extensively investigated for the assessment of renal vascular function/dysfunction; however, few studies have focused on the intrarenal vasculature. Experimental approach: We devised a microvascular force measurement system, which allowed us to measure contractions of interlobar arteries (ILA), isolated from within the mouse kidney and prepared without endothelium. Key results: KCl (50 mM) induced similar force development in the aorta and RA but responses in the ILA were about 50% lower. Treatment of RA with 10 ,M phenylephrine (PE), 10 nM U46619 (thromboxane A2 analogue) or 10 ,M prostaglandin F2, elicited a response greater than 150% of that induced by KCl. In ILA, 10 nM U46619 elicited a response that was 130% of the KCl-induced response; however, other agonists induced levels similar to that induced by KCl. High glucose conditions (22.2 mM glucose) significantly enhanced responses in RA and ILA to PE or U46619 stimulation. This enhancement was suppressed by rottlerin, a calcium-independent PKC inhibitor, indicating that glucose-dependent, enhanced small vessel contractility in the kidney was linked to the activation of calcium-independent PKC. Conclusion and implications: Extra- and intrarenal arteries exhibit different profiles of agonist-induced contractions. In ILA, only U46619 enhanced small vessel contractility in the kidney, which might lead to renal dysfunction and nephropathy through reduced intrarenal blood flow rate. A model has been established, which will allow the assessment of contractile responses of intrarenal arteries from murine models of renal disease, including type 2 diabetes. British Journal of Pharmacology (2008) 155, 1204,1213; doi:10.1038/bjp.2008.365; published online 22 September 2008 [source] Blood flow rate measurements with indicator techniques revisitedCLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, Issue 6 2009Per Sejrsen Summary In view of the emerging role, disturbances in regional blood flow rate seem to play in the pathogenesis of the metabolic syndrome; we review the concepts of the classical indicator dilution and washout techniques used for determinations of regional blood flow rate. Prerequisites, assumptions, necessary precautions for the application of these experimental techniques are emphasized. Special attention has been carried out to elucidate the consequence of a choice of indicators having a large distribution volume in the tissues. [source] Supraorbital cutaneous blood flow rate during carotid endarterectomyCLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, Issue 6 2006Jens D. Hove Summary Background:, The supraorbital skin region is supplied by the supraorbital artery, which is a branch of the internal carotid artery. The supraorbital cutaneous blood flow rate may therefore be influenced by changes in the internal carotid artery flow during carotid endarterectomy. Methods:, The supraorbital cutaneous blood flow rate was measured by the application of heat to the skin and following the subsequent dissipation of the heat in seven patients undergoing carotid endarterectomy. At the same time, the oxygenation in the right and left frontal region was monitored by near-infrared spectroscopy (NIRS). Results:, During cross-clamping of the carotid artery, the ipsilateral NIRS-determined frontal oxygenation tended to decrease [67 ± 13% to 61 ± 11% (P = 0·06); contralateral 68 ± 11% to 66 ± 8%] as did the supraorbital cutaneous blood flow rate from 56 ± 23 to 44 ± 7 ml 100 g,1 min,1. With the opening of the external carotid artery, the NIRS-determined frontal oxygenation reversed to 66 ± 8% (P<0·05) on the ipsilateral side, with no significant change on the contralateral side and the supraorbital cutaneous blood flow rate increased to 53 ± 11 (P<0·05). Opening of the internal carotid artery did not significantly affect the NIRS (67 ± 8% and 69 ± 9%; ipsilateral, contralateral), but the supraorbital cutaneous blood flow rate increased to 88 ± 10 ml 100 g,1 min,1 (P<0·001). Conclusion:, Cross-clamping of the internal carotid artery affects the supraorbital cutaneous blood flow rate as well as the frontal lobe oxygenation. [source] Comparison of side hole versus non side hole high flow hemodialysis cathetersHEMODIALYSIS INTERNATIONAL, Issue 1 2006Michael G. TAL Abstract Current literature suggests that side holes may be detrimental to dialysis catheter performance. Today, these catheters are primarily available with side holes. The purpose of this study was to compare flow rates, infection rate, and survival of side hole vs. non side hole hemodialysis catheters. Over a 16-month period patients were arbitrarily assigned to either a 14.5 F MAHURKAR® MAXIDÔ cuffed dual lumen tunneled catheter with side holes or a 14.5 F MAHURKAR MAXID cuffed dual lumen tunneled catheter without side holes ("non side hole catheters"). We performed a retrospective analysis of catheter flow rates, patency, catheter survival, and catheter-related infections. Information was gathered for the life of the catheter or up to 28 weeks. A total of 54 patients were enrolled in the study. Thirty-seven of 54 (68%) patients received a catheter with side holes for a total of 3,930 catheter days and 17/54 (32%) received a similar catheter without side holes for a total of 2,188 catheter days. Catheter infection necessitating removal of the catheter occurred in 10/37 catheters with side holes and 1/17 without side holes. Infection rates per 1,000 catheter days were 2.545 with side holes and 0.254 without side holes (p<0.001). Slightly improved catheter survival (p<0.05) was recorded with the non side hole catheters. No insertion complication (e.g., air embolization, bleeding, or kinking) occurred with either catheter. One catheter without side holes had to be repositioned 5 days after insertion because of poor flows. No significant difference was recorded in mean blood flow rates between the catheters. Results indicate reduced catheter infection rate in hemodialysis patients with the use of non side hole dual lumen tunneled cuffed catheters. [source] Factors affecting concentration of citrate in dialyzers when using citrate hemodialysate in vitroHEMODIALYSIS INTERNATIONAL, Issue 1 2005G. Baosong Objective:,To observe the factors that affect the citrate concentration in hollow fiber when using citrate hemodialysate. Methods:,By modeling hemodialysis in vitro, we studied 6 types of hemodialyzers at different blood flow rates, different dialysate flow-rate, and different fluids in vitro to detect the citrate concentration in hollow fiber. Results:,The citrate concentrations in different hemodialyzers were F60 > FB-130UGA > GA-HP130 > F6 > FB-130AGA > WS-70 in turn. The concentrations at different blood flow-rates were different 100 mL/min > 200 mL/min. Conclusions:,The concentration of citrate in hollow fiber is affected by different types of hemodialyzers and different blood as well as dialysate flow-rates. To achieve anticoagulation when using citrate hemodialysate, we must select suitable hemodialyzer such as FB-130UGA. [source] Association between blood flow and inflammatory state in a T-cell transfer model of inflammatory bowel disease in miceINFLAMMATORY BOWEL DISEASES, Issue 5 2010Norman R. Harris PhD Abstract Background: Adoptive transfer of naive T-lymphocyte subsets into lymphopenic mice initiates chronic gut inflammation that mimics several aspects of inflammatory bowel disease (IBD). Patients with IBD can have profound alterations in intestinal blood flow, but whether the same is true in the T-cell transfer model has yet to be determined. Methods: In the current study, chronic intestinal inflammation was induced in recombinase-activating gene-1-deficient (RAG,/,) mice by adoptive transfer of CD4+ T-lymphocytes obtained from interleukin-10 deficient (IL-10,/,) mice. Results: Four weeks later, widespread colonic inflammation was observed in the reconstituted recipients, in contrast to 2 control sets of mice injected with a different subset of lymphocytes or with vehicle alone. We observed that the resulting pathology induced in the reconstituted RAG,/, mice was divided distinctly into 2 subsets: 1 with blood flow near normal with very high inflammation scores, and the other with severely attenuated blood flow but with much lower signs of inflammation. Colonic and ileal blood flow rates in the latter subset of CD4+ mice averaged only ,30% compared to the mice with higher inflammation scores. The lower blood flow rates were associated with greatly reduced red blood cell concentrations in the tissue, suggesting a possible loss of vascular density. Conclusions: In this model of chronic intestinal inflammation, mild inflammation was associated with significant decreases in blood flow. Inflamm Bowel Dis 2009 [source] Efficacy and safety of DALI LDL-apheresis at high blood flow rates: A prospective multicenter studyJOURNAL OF CLINICAL APHERESIS, Issue 4 2003T. Wendler Abstract Direct adsorption of lipids (DALI) is the first LDL-apheresis method compatible with whole blood. Usually, the blood flow rate is adjusted at 60,80 ml/min, which results in session times of about 2 hr. The present study was performed to test the safety and efficacy of low-density lipoprotein cholesterol (LDL-C) and lipoprotein (a) [Lp(a)] removal by DALI at high blood flow rates in order to reduce treatment time. Thirteen chronic DALI patients in seven centers suffering from hypercholesterolemia (LDL-C 162 ± 42 mg/dl at baseline) and coronary artery disease were treated on a weekly or biweekly basis by DALI apheresis. The blood flow rate QB was held constant for at least two sessions, respectively, and was increased from 60 to 80, 120, 160, 200, and 240 ml/min. All patients had pre-existing av-fistulas. The anticoagulation was performed by a heparin bolus plus ACD-A at a ratio of citrate: blood ranging from 1:20 to 1:90. Clinically, the sessions were well tolerated and only 26/201 sessions (12%) of the treatments were fraught with minor adverse events. Acute LDL-C reductions (derived from LDL-C levels determined by lipoprotein electrophoresis) averaged 72/66/60/53/50/48% for QB = 60/80/120/160/200/240 ml/min. Lp(a) reductions were 68/67/62/60/58/56%, whereas HDL-C losses were ,10%. Routine blood chemistries and blood cell counts remained in the normal range. Treatment times averaged 142/83/45 min at Qb = 60/120/240 ml/min. On average, DALI LDL-apheresis could be performed safely and effectively at high blood flow rates up to at least 120 ml/min in patients with good blood access, which significantly reduced treatment time from 142 to 83 min (,42%). J. Clin. Apheresis 18:157,166, 2003. © 2003 Wiley-Liss, Inc. [source] High-resolution blood flow velocity measurements in the human fingerMAGNETIC RESONANCE IN MEDICINE, Issue 4 2001M. Klarhöfer Abstract MR phase contrast blood flow velocity measurements in the human index finger were performed with triggered, nontriggered, and cine acquisition schemes. A strong (Gmax = 200 mT/m), small bore (inner diameter 12 cm) gradient system inserted in a whole body 3 Tesla MR scanner allowed high-resolution imaging at short echo times, which decreases partial volume effects and flow artifacts. Arterial blood flow velocities ranging from 4.9,19 cm/sec were measured, while venous blood flow was significantly slower at 1.5,7.1 cm/sec. Taking into account the corresponding vessel diameters ranging from 800 ,m to 1.8 mm, blood flow rates of 3.0,26 ml/min in arteries and 1.2,4.8 ml/min in veins are obtained. The results were compared to ultrasound measurements, resulting in comparable blood flow velocities in the same subjects. Magn Reson Med 45:716,719, 2001. © 2001 Wiley-Liss, Inc. [source] Hemocompatibility of a Miniaturized Extracorporeal Membrane Oxygenation and a Pumpless Interventional Lung Assist in Experimental Lung InjuryARTIFICIAL ORGANS, Issue 1 2010Ruedger Kopp Abstract Extracorporeal membrane oxygenation (ECMO) is used for most severe acute respiratory distress syndrome cases in specialized centers. Hemocompatibility of devices depends on the size and modification of blood contacting surfaces as well as blood flow rates. An interventional lung assist using arteriovenous perfusion of a low-resistance oxygenator without a blood pump (Novalung, Hechingen, Germany) or a miniaturized ECMO with reduced filling volume and a diagonal blood pump (Deltastream, Medos AG, Stolberg, Germany) could optimize hemocompatibility. The aim of the study was to compare hemocompatibility with conventional ECMO. Female pigs were connected to extracorporeal circulation for 24 h after lavage induced lung injury (eight per group). Activation of coagulation and immune system as well as blood cell damage was measured. A P value <0.05 was considered significant. Plasmatic coagulation was slightly activated in all groups demonstrated by increased thrombin-anti-thrombin III-complex. No clinical signs of bleeding or thromboembolism occurred. Thrombelastography revealed decreased clotting capacities after miniaturized ECMO, probably due to significantly reduced platelet count. These resulted in reduced dosage of intravenous heparin. Scanning electron microscopy of oxygenator fibers showed significantly increased binding and shape change of platelets after interventional lung assist. In all groups, hemolysis remained negligible, indicated by low plasma hemoglobin concentration. Interleukin 8 and tumor necrosis factor-, concentration as well as leukocyte count remained unchanged. Both devices demonstrated adequate hemocompatibility for safe clinical application, although a missing blood pump did not increase hemocompatibility. Further studies seem necessary to analyze the influence of different blood pumps on platelet drop systematically. [source] DALI Apheresis in Hyperlipidemic Patients: Biocompatibility, Efficacy, and Selectivity of Direct Adsorption of Lipoproteins from Whole BloodARTIFICIAL ORGANS, Issue 2 2000T. Bosch Abstract: Recently, the first apheresis technique for direct adsorption of low-density lipoprotein (LDL) and lipoprotein(a) [Lp(a)] from whole blood (DALI) was developed that does not require a prior plasma separation. That markedly simplifies the extracorporeal circuit. The aim of the present study was to test the acute biocompatibility, efficacy, and selectivity of DALI apheresis. In a prospective clinical study, 6 hypercholesterolemic patients suffering from angiographically proven atherosclerosis were treated 4 times each by DALI. 1.3 patient blood volumes were treated per session at blood flow rates of 60,80 ml/min using 750 or 1,000 ml of polyacrylate/polyacrylamide adsorber gel. The anticoagulation consisted of an initial heparin bolus followed by a citrate infusion. The sessions were clinically essentially uneventful. Mean corrected reductions of lipoproteins amounted to 65% for LDL-cholesterol, 54% for Lp(a), 28% for triglycerides, 1% for HDL-cholesterol, and 8% for fibrinogen. The selectivity of lipoprotein removal was high. Cell counts remained virtually unchanged and no signs of hemolysis or clotting were detected. Cell activation parameters elastase, ,-thromboglobulin, interleukin-1,, and IL-6 showed no significant increase. Complement activation was negligible. There was significant, but clinically asymptomatic, bradykinin activation in the adsorber with mean maxima of 12,000 pg/ml in the efferent line at 1,000 ml of treated blood volume. In conclusion, DALI proved to be safe, selective, and efficient for the adsorption of LDL-C and Lp(a), which simplifies substantially the extracorporeal therapy in hypercholesterolemic patients. [source] Influence of blood flow and millimeter wave exposure on skin temperature in different thermal modelsBIOELECTROMAGNETICS, Issue 1 2009S.I. Alekseev Abstract Recently we showed that the Pennes bioheat transfer equation was not adequate to quantify mm wave heating of the skin at high blood flow rates. To do so, it is necessary to incorporate an "effective" thermal conductivity to obtain a hybrid bioheat equation (HBHE). The main aim of this study was to determine the relationship between non-specific tissue blood flow in a homogeneous unilayer model and dermal blood flow in multilayer models providing that the skin surface temperatures before and following mm wave exposure were the same. This knowledge could be used to develop multilayer models based on the fitting parameters obtained with the homogeneous tissue models. We tested four tissue models consisting of 1,4 layers and applied the one-dimensional steady-state HBHE. To understand the role of the epidermis in skin models we added to the one- and three-layer models an external thin epidermal layer with no blood flow. Only the combination of models containing the epidermal layer was appropriate for determination of the relationship between non-specific tissue and dermal blood flows giving the same skin surface temperatures. In this case we obtained a linear relationship between non-specific tissue and dermal blood flows. The presence of the fat layer resulted in the appearance of a significant temperature gradient between the dermis and muscle layer which increased with the fat layer thickness. Bioelectromagnetics 30:52,58, 2009. © 2008 Wiley-Liss, Inc. [source] |