Determination of clavulanic acid in calf plasma by liquid chromatography tandem mass spectrometry

JOURNAL OF MASS SPECTROMETRY (INCORP BIOLOGICAL MASS SPECTROMETRY), Issue 11 2006
Tim Reyns
Abstract A method for the quantification of clavulanic acid in calf plasma using high-performance liquid chromatography combined with electrospray ionization (ESI) mass spectrometry, operating in the negative ionization mode (LC-MS/MS), is presented. Sample preparation includes a simple and fast deproteinization with acetonitrile and a back-extraction of the acetonitrile with dichloromethane. Chromatography is performed on a reversed-phase PLRP-S polymeric column using 0.05% formic acid in water and acetonitrile. The limit of quantification is 25 ng/ml, which is lower than other published methods using ultraviolet (UV), fluorimetric or mass spectrometric detection. The limit of detection is calculated to be 3.5 ng/ml. The stability of clavulanic acid was demonstrated according to The Guidelines of Bioanalytical Method Validation of The Food and Drug Administration (FDA): freeze and thaw stability, short-term stability, long-term stability, stock solution stability and postpreparative stability. The method is used in a pharmacokinetic and bioequivalence study of amoxycillin/clavulanic acid formulations in calves. Copyright © 2006 John Wiley & Sons, Ltd. [source]


LC-MS/MS determination of 2-(4-((2-(2S,5R)-2-Cyano-5-ethynyl-1-pyrrolidinyl)-2-oxoethylamino)-4-methyl-1-piperidinyl)-4-pyridinecarboxylic acid (ABT-279) in dog plasma with high-throughput protein precipitation sample preparation

BIOMEDICAL CHROMATOGRAPHY, Issue 11 2007
Joseph Kim
Abstract As an effective DPP-IV inhibitor, 2-(4-((2-(2S,5R)-2-Cyano-5-ethynyl-1-pyrrolidinyl)-2-oxoethylamino)-4-methyl-1-piperidinyl)-4-pyridinecarboxylic acid (ABT-279), is an investigational drug candidate under development at Abbott Laboratories for potential treatment of type 2 diabetes. In order to support the development of ABT-279, multiple analytical methods for an accurate, precise and selective concentration determination of ABT-279 in different matrices were developed and validated in accordance with the US Food and Drug Administration Guidance on Bioanalytical Method Validation. The analytical method for ABT-279 in dog plasma was validated in parallel to other validations for ABT-279 determination in different matrices. In order to shorten the sample preparation time and increase method precision, an automated multi-channel liquid handler was used to perform high-throughput protein precipitation and all other liquid transfers. The separation was performed through a Waters YMC ODS-AQ column (2.0 × 150 mm, 5 µm, 120 Å) with a mobile phase of 20 mm ammonium acetate in 20% acetonitrile at a flow rate of 0.3 mL/min. Data collection started at 2.2 min and continued for 2.0 min. The validated linear dynamic range in dog plasma was between 3.05 and 2033.64 ng/mL using a 50 µL sample volume. The achieved r2 coefficient of determination from three consecutive runs was between 0.998625 and 0.999085. The mean bias was between ,4.1 and 4.3% for all calibration standards including lower limit of quantitation. The mean bias was between ,8.0 and 0.4% for the quality control samples. The precision, expressed as a coefficient of variation (CV), was ,4.1% for all levels of quality control samples. The validation results demonstrated that the high-throughput method was accurate, precise and selective for the determination of ABT-279 in dog plasma. The validated method was also employed to support two toxicology studies. The passing rate was 100% for all 49 runs from one validation study and two toxicology studies. Copyright © 2007 John Wiley & Sons, Ltd. [source]


Determination of ethyl sulfate , a marker for recent ethanol consumption , in human urine by CE with indirect UV detection

ELECTROPHORESIS, Issue 23 2006
Francesc A. Esteve-Turrillas
Abstract A CE method for the determination of the ethanol consumption marker ethyl sulfate,(EtS) in human urine was developed. Analysis was performed in negative polarity mode with a background electrolyte composed of 15,mM maleic acid, 1,mM phthalic acid, and 0.05,mM cetyltrimethylammonium bromide (CTAB) at pH,2.5 and indirect UV detection at 220,nm (300,nm reference wavelength). This buffer system provided selective separation conditions for EtS and vinylsulfonic acid, employed as internal standard, from urine matrix components. Sample pretreatment of urine was minimized to a 1:5 dilution with water. The optimized CE method was validated in the range of 5,700,mg/L using seven lots of urine. Intra- and inter-day precision and accuracy values, determined at 5, 60, and 700,mg/L with each lot of urine, fulfilled the requirements according to common guidelines for bioanalytical method validation. The application to forensic urine samples collected at autopsies as well as a successful cross-validation with a LC-MS/MS-based method confirmed the overall validity and real-world suitability of the developed expeditious CE assay (sample throughput 130 per day). [source]


Quantification of fudosteine in human plasma by high-performance liquid chromatography-electrospray ionization mass spectrometry employing precolumn derivatization with 9-fluorenylmethyl chloroformate

JOURNAL OF MASS SPECTROMETRY (INCORP BIOLOGICAL MASS SPECTROMETRY), Issue 5 2006
Fengguo Xu
Abstract This paper describes a novel method for the sensitive and selective determination of fudosteine in human plasma. The method involves a derivatization step with 9-fluorenylmethyl chloroformate (FMOC-Cl) in borate buffer and detection based on high-performance liquid chromatography-electrospray ionization mass spectrometry (LC/ESI/MS). After acetonitrile-induced protein precipitation of plasma samples, fudosteine was derivatized with FMOC-Cl, then extracted by ethyl acetate, evaporated, reconstituted and injected using an LC/ESI/MS instrument. Separation was achieved using an ODS column and isocratic elution. Excellent linearity was obtained for the entire calibration range from 0.05 to 20 µg/ml. Validation assays of the lower limit of quantification (LLOQ) as well as for the intra- and inter-batch precision and accuracy met the international acceptance criteria for bioanalytical method validation. Using the developed analytical method, fudosteine could be detected for the first time in human plasma with a low limit of detection (LLOD) of 0.03 µg/ml. The proposed method has been successfully applied to study the pharmacokinetics of fudosteine in healthy Chinese volunteers after single and multiple oral administration. Copyright © 2006 John Wiley & Sons, Ltd. [source]


Quantitative analysis of docetaxel in human plasma using liquid chromatography coupled with tandem mass spectrometry

BIOMEDICAL CHROMATOGRAPHY, Issue 5 2005
I. E. L. M. Kuppens
Abstract An assay for the quantitative determination of docetaxel in human plasma is described. Docetaxel was extracted from the matrix using liquid,liquid extraction with ter -butylmethylether, followed by high-performance liquid chromatographic analysis using an alkaline eluent. Paclitaxel was used as internal standard. Positive ionization electrospray tandem mass spectrometry was performed for selective and sensitive detection. The method was validated according to the FDA guidelines on bioanalytical method validation. The validated range for docetaxel was from 0.25,1000 ng/mL using 200 µL plasma aliquots. The method requires only a limited volume (200 µL) of human plasma and the method can be applied in studies requiring a low lower limit of quantitation of 0.25 ng/mL. The assay was applied successfully in several clinical and pharmacological studies with docetaxel. Copyright © 2004 John Wiley & Sons, Ltd. [source]


Enantioselective LC/MS method for the determination of an antimalarial agent Fenozan B07 in dog plasma

CHIRALITY, Issue 5 2006
Ciriaco Maraschiello
Abstract A chiral liquid chromatography/mass spectrometry (LC/MS) bioanalytical procedure has been developed for the analysis of the antimalaric agent Fenozan B07 in dog plasma. Normal-phase chromatography involving a phenylcarbamate derivative of cellulose coated on silica gel as the chiral stationary phase was used to resolve (,)-(S,S)-B07 from (+)-(R,R)-B07. The enantiomers were detected by a mass spectrometer equipped with an atmospheric pressure chemical ionization (APCI) interface operated in the negative ion mode. A mass spectrum, characterized by a base peak of m/z 285, was obtained for each enantiomer. The m/z 285 ion was very specific for the analysis of both enantiomers in the plasma. The selected ion monitoring analysis of the plasma samples was therefore performed at m/z 285 for quantitative purposes. The enantiomers were extracted from the plasma in a basic medium and purified by solid-phase extraction using a hydrophilic,lipophilic balanced sorbent. A lower limit of quantification of 2 ng/mL in plasma was achieved for both enantiomers. The quantitative procedure reported in this study was highly specific and sensitive, and was validated according to the FDA guidance on bioanalytical method validation. Chirality, 2006. © 2006 Wiley-Liss, Inc. [source]