Association of Left Atrial Strain and Strain Rate Assessed by Speckle Tracking Echocardiography with Paroxysmal Atrial Fibrillation

ECHOCARDIOGRAPHY, Issue 10 2009
Wei-Chuan Tsai M.D.
Background: We hypothesized that contraction of the LA wall could be documented by speckle tracking and could be applied for assessment of LA function. This study tried to identify the association between LA longitudinal strain (LAS) and strain rate (LASR) measured by speckle tracking with paroxysmal atrial fibrillation (PAF). Methods: Fifty-two patients (61 ± 17 years old, 23 men) with sinus rhythm at baseline referred for the evaluation of episodic palpitation were included. Standard four-chamber and two-chamber views were acquired and analyzed off-line. Peak LAS and LASR were carefully identified as the peak negative inflection of speckle tracking waves after P-wave gated by electrocardiography. Results: Ten patients (19%) had PAF. LAS, LASR, age, left ventricular end-diastolic dimension, left ventricular mass, LA volume, and mitral early filling-to-annulus early velocity ratio were different between patients with and without PAF. After multivariate analysis, LASR was significantly independently associated with PAF (OR 8.56, 95% CI 1.14,64.02, P = 0.036). Conclusion: Speckle tracking echocardiography could be used in measurements of LAS and LASR. Decreased negative LASR was independently associated with PAF. [source]


Catheterization,Doppler Discrepancies in Nonsimultaneous Evaluations of Aortic Stenosis

ECHOCARDIOGRAPHY, Issue 5 2005
Payam Aghassi M.D.
Prior validation studies have established that simultaneously measured catheter (cath) and Doppler mean pressure gradients (MPG) correlate closely in evaluation of aortic stenosis (AS). In clinical practice, however, cath and Doppler are rarely performed simultaneously; which may lead to discrepant results. Accordingly, our aim was to ascertain agreement between these methods and investigate factors associated with discrepant results. We reviewed findings in 100 consecutive evaluations for AS performed in 97 patients (mean age 72 ± 10 yr) in which cath and Doppler were performed within 6 weeks. We recorded MPG, aortic valve area (AVA), cardiac output, and ejection fraction (EF) by both methods. Aortic root diameter, left ventricular end-diastolic dimension (LVIDd) and posterior wall thickness (PWT) were measured by echocardiography and gender, heart rate, and heart rhythm were also recorded. An MPG discrepancy was defined as an intrapatient difference > 10 mmHg. Mean pressure gradients by cath and Doppler were 36 ± 22 mmHg and 37 ± 20 mmHg, respectively (P = 0.73). Linear regression showed good correlation (r = 0.82) between the techniques. An MPG discrepancy was found in 36 (36%) of 100 evaluations; in 19 (53%) of 36 evaluations MPG by Doppler was higher than cath, and in 17 (47%) of 36, it was lower. In 33 evaluations, EF differed by >10% between techniques. Linear regression analyses revealed that EF difference between studies was a significant predictor of MPG discrepancy (P = 0.004). Women had significantly higher MPG than men by both cath and Doppler (43 ± 25 mmHg versus 29 ± 15 mmHg [P = 0.001]; 42 ± 23 mmHg versus 32 ± 15 mmHg [P = 0.014], respectively). Women exhibited discrepant results in 23 (47%) of 49 evaluations versus 13 (25%) of 51 evaluations in men (P = 0.037). After adjustment for women's higher MPG, there was no statistically significant difference in MPG discrepancy between genders (P = 0.22). No significant interactions between MPG and aortic root diameter, relative wall thickness (RWT), heart rate, heart rhythm, cardiac output, and time interval between studies were found. In clinical practice, significant discrepancies in MPG were common when cath and Doppler are performed nonsimultaneously. No systematic bias was observed and Doppler results were as likely yield lower as higher MPGs than cath. EF difference was a significant predictor of discrepant MPG. Aortic root diameter, relative wall thickness, heart rate, heart rhythm, cardiac output, presence or severity of coronary artery disease, and time interval between studies were not predictors of discrepant results. [source]


A Hand-Carried Personal Ultrasound Device for Rapid Evaluation of Left Ventricular Function: Use After Limited Echo Training

ECHOCARDIOGRAPHY, Issue 4 2003
Kristina Lemola
A hand-carried personal ultrasound device (HCPUD) may be used for rapid cardiac screening by physicians with limited echo training. Our objective was to determine the accuracy of rapid HCPUD evaluation of left ventricular (LV) size and function when used by a Cardiology Fellow. Forty-five patients underwent an HCPUD exam using a 2.4-kg device with a 2- to 4-MHz curved transducer and color power Doppler (SonoSite). The results were compared with sonographer-performed and echocardiographer-interpreted exams using conventional equipment. The HCPUD exam lasted 6 ± 2 minutes. There was 100% agreement between HCPUD and conventional echo on qualitative assessment of LV systolic function. Comparing the HCPUD and conventional linear measurements of left ventricular end-diastolic dimension (LVEDD) and of interventricular septal (IVS) thickness: LVEDD is HCPUD = 0.94 conventional ,0.2,r = 0.82, P < 0.0001; IVS is HCPUD= 0.59conventional+0.6, r = 0.69, P < 0.0001. Thus, an HCPUD can effectively be used after limited training to rapidly screen for qualitative abnormalities of LV systolic function. Quantitative measurements of smaller structures with the HCPUD are more challenging. (ECHOCARDIOGRAPHY, Volume 20, May 2003) [source]


Sex-Specific Impact of Aldosterone Receptor Antagonism on Ventricular Remodeling and Gene Expression after Myocardial Infarction

CLINICAL AND TRANSLATIONAL SCIENCE, Issue 2 2009
Ph.D., Rosemeire M. Kanashiro-Takeuchi D.V.M.
Abstract Aldosterone receptor antagonism reduces mortality and improves post-myocardial infarction (Ml) remodeling. Because aldosterone and estrogen signaling pathways interact, we hypothesized that aldosterone blockade is sex-specific. Therefore, we investigated the mpact of eplerenone on left ventricular (LV) remodeling and gene expression of male infarcted rats versus female infarcted rats. Ml and Sham animals were randomized to receive eplerenone (100 mg/kg/day) or placebo 3 days post-surgery for 4 weeks and assessed by echocardiography. In the Ml placebo group, left ventricular end-diastolic dimension (LVEDD) increased from 7.3 ± 0.4 mm to 10.2 ± 1.0 mm (p < 0.05) and ejection fraction (EF) decreased from 82.3 + 4% to 45.5 + 11% (p < 0.05) in both sexes (p= NS between groups). Eplerenone attenuated LVEDD enlargement more effectively in females (8.8 ± 0.2 mm, p < 0.05 vs. placebo) than in males (9.7 ± 0.2 mm, p= NS vs. placebo) and improved EF in females (56.7 ± 3%, p < 0.05 vs. placebo) but not in males (50.6 + 3%, p= NS vs. placebo). Transcriptomic analysis using Rat_230,2.0 microarrays (Affymetrix) revealed that in females 19% of downregu-lated genes and 44% of upregulated genes post-MI were restored to normal by eplerenone. In contrast, eplerenone only restored 4% of overexpressed genes in males. Together, these data suggest that aldosterone blockade reduces Ml-induced cardiac remodeling and phenotypic alterations of gene expression preferentially in females than in males. The use of transcriptomic signatures to detect greater benefit of eplerenone in females has potential implications for personalized medicine. [source]