Home About us Contact | |||
Valve Repair (valve + repair)
Kinds of Valve Repair Selected Abstracts3 ISCHEMIC MITRAL VALVE REPAIR: THE IMPACT OF THE MECHANISM OF MITRAL REGURGITATION ON LATE POSTOPERATIVE RESULTSECHOCARDIOGRAPHY, Issue 1 2004E. Ereminien Aim: The aim of our study was to establish the anatomical-functional mechanisms of ischemic mitral regurgitation (MR) and to analyse its impact on late results after mitral valve (MV) reconstructive surgery. Methods: The study included 53 patients with ischemic MR, who underwent CABG and MV repair. MV surgery consisted of subvalvular apparatus repair and/or annuloplasty. 2D Doppler investigations performed pre-, 10,14 days, and 12 months after surgery included evaluation of MV and left ventricular (LV) geometry and function. Results: Analysis of the mechanisms of ischemic MR permitted dividing patients into two groups: group 1,29 patients with inferobasal scar and posterior papillary muscle (PM) displacement, including 22 patients with PM infarction and 7 patients without it, and group 2,24 patients with isolated mitral annulus (MA) dilation. In the case of PM infarction two different mechanisms of MR were stated: (a) P3 restriction and A3 prolapse due to chordal tethering, (b) A3 P3 (commissural) prolapse due to chordal papillary elongation. Preoperatively LV geometry and function were better preserved in group 1 and late MV repair results were better versus (vs.) group 2: LV end-systolic diameter index decreased from 22.9 ± 3.1 mm/m2 to 20.9 ± 3.6 mm/m2 at 1 year, p < 0.05, LV ejection fraction increased from 34.9 ± 8.4 to 41.8 ± 8.1%, respectively, p < 0.05. No significant changes in LV geometry and function were noted in group 2. Conclusions: The underlying mechanism of ischemic MR has an impact on MV repair results. In patients with MR due to posterobasal infarction MV repair resulted in more favorable postoperative effect-marked improvement in LV geometry and function late after surgery versus MR due to isolated MA dilation. [source] Superior Vena Cava Syndrome post Minimally Invasive Mitral Valve RepairJOURNAL OF CARDIAC SURGERY, Issue 2 2010Turki B. Albacker M.D. The tamponade was caused by local compression of junction between the right atrium and superior vena cava. This case illustrates the importance of using transesophageal echocardiogram in postoperative management of cardiac surgery patients.,(J Card Surg 2010;25:174-175) [source] Ascending Thoracic Aorta Aneurysm Surgery and Aortic Valve Repair during PregnancyJOURNAL OF CARDIAC SURGERY, Issue 5 2009Pedro Gama M.D. A 31-year-old pregnant woman underwent surgery for a large ascending aorta aneurysm threatening rupture in the 12th week and then went on to a cesarean section at 38 weeks, which produced a healthy baby. [source] Mitral Valve Repair in a Patient With Ter Haar SyndromeJOURNAL OF CARDIAC SURGERY, Issue 5 2006Semih Barlas M.D. Up to date only ten patients were reported. We present a living patient with ter Haar Syndrome who has undergone successful mitral valve repair. [source] Beating Heart Ischemic Mitral Valve Repair and Coronary Revascularization in Patients with Impaired Left Ventricular FunctionJOURNAL OF CARDIAC SURGERY, Issue 5 2003Edvin Prifti M.D., Ph.D. Materials and Methods: Between January 1993 and February 2001, 91 patients with LVEF between 17% and 35% and chronic ischemic MVR (grade III,IV), underwent MV repair in concomitance with coronary artery bypass grafting (CABG) Sixty-one patients (Group I) underwent cardiac surgery with cardioplegic arrest, and 30 patients (Group II) underwent beating heart combined surgery. Aortic valve insufficiency was considered a contraindication for the on-pump/beating heart procedure. Mean age in Group I was 64.4 ± 7 years and in Group II, 65 ± 6 years (p = 0.69). Results: The in-hospital mortality in Group I was 8 (13%) patients versus 2 (7%) patients in Group II (p > 0.1). The cardiopulmonary bypass (CPB) time was significantly higher in Group I (p < 0.001). In Groups I and II, respectively (p > 0.1), 2.5 ± 1 and 2.7 ± 0.8 grafts per patient were employed. Perioperative complications were identified in 37 (60.7%) patients in Group I versus 10 (33%) patients in Group II (p = 0.025). Prolonged inotropic support of greater than 24 hours was needed in 48 (78.7%) patients (Group I) versus 15 (50%) patients (Group II) (p = 0.008). Postoperative IABP and low cardiac output incidence were significantly higher in Group I, p = 0.03 and p = 0.027, respectively. Postoperative bleeding greater than 1000 mL was identified in 24 patients (39.4%) in Group I versus 5 (16.7%) in Group II (p = 0.033). Renal dysfunction incidence was 65.6% (40 patients) in Group I versus 36.7% (11 patients) in Group II (p = 0.013). The echocardiographic examination within six postoperative months revealed a significant improvement of MV regurgitation fraction, LV function, and reduced dimensions in both groups. The postoperative RF was significantly lower in Group II patients 12 ± 6 (%) versus 16 ± 5.6 (%) in Group I (p = 0.001). The 1, 2, and 3 years actuarial survival including all deaths was 91.3%, 84.2%, and 70% in Group I and 93.3%, 87.1%, and 75% in Group II (p = ns). NYHA FC improved significantly in all patients from both groups. Conclusion. We conclude that patients with impaired LV function and ischemic MVR may undergo combined surgery with acceptable mortality and morbidity. The on/pump beating heart MV repair simultaneous to CABG offers an acceptable postoperative outcome in selected patients. [source] Upper Loop Reentry Post Mitral Valve RepairJOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, Issue 12 2008RICHARD L. SNOWDON M.D. No abstract is available for this article. [source] Feasibility of Myxomatous Mitral Valve Repair Using Direct Leaflet and Chordal Radiofrequency AblationJOURNAL OF INTERVENTIONAL CARDIOLOGY, Issue 6 2008JEFFREY L. WILLIAMS M.D., M.S. Objective: Minimally invasive repair of mitral valve prolapse (MVP) causing severe mitral regurgitation (MR) should reduce MR and have chronic durability. Our ex vivo, acute in vivo, and chronic in vivo studies suggest that direct application of radiofrequency ablation (RFA) to mitral leaflets and chordae can effect these repair goals to decrease MR. Methods: A total of seven canines were studied to assess the effects of RFA on mitral valve structure and function. RFA was applied ex vivo (n = 1), acutely in vivo using a right lateral thoracotomy and cardiopulmonary bypass (n = 3), and chronically in vivo using percutaneous access to the heart (n = 3). RFA was applied to the mitral valve and its associated chordae. Mitral valve structure and function (in vivo preparations) were then assessed. Results: Ex vivo application of RFA resulted in qualitative reduction in mitral leaflet surface area and chordal length. Acute in vivo application of RFA to canines found to have MVP causing severe MR demonstrated a 43.7,60.7% statistically significant (P = 0.039) reduction in postablation MR. Chronic, in vivo, percutaneous application of RFA was found to be feasible and the engendered alterations durable. Conclusion: These data suggest that myxomatous mitral valve repair using radiofrequency energy delivered via catheter is feasible. [source] Transcatheter Mitral Valve Repair for Functional Mitral Regurgitation: Coronary Sinus ApproachJOURNAL OF INTERVENTIONAL CARDIOLOGY, Issue 6 2007NICOLO PIAZZA M.D. Mitral regurgitation has become recognized as an important health problem. More specifically, functional mitral regurgitation is associated with worse outcomes in heart failure, postmyocardial infarction, and perioperative coronary artery bypass surgery patients. Many patients with severe mitral regurgitation are denied or refused mitral valve surgery. A less invasive procedure with possibly fewer potential complications may thus be attractive for patients with severe mitral regurgitation. Devices used for coronary sinus (CS) mitral annuloplasty are directed toward patients with functional mitral regurgitation. Because of its easy accessibility and close relationship to the posterior mitral annulus (MA), alterations of the CS geometry with percutaneous devices may translate to displacement of the posterior annulus and correct mitral leaflet coaptation. This review will focus on the contemporary CS annuloplasty devices: (1) Edwards MONARC system; (2) Cardiac Dimensions CARILLON; and (3) Viacor Shape Changing Rods system. In addition, important information obtained from recent imaging studies describing the relationship between the CS, MA, and coronary arteries will be reviewed. [source] Percutaneous Mitral Valve Repair for Mitral RegurgitationJOURNAL OF INTERVENTIONAL CARDIOLOGY, Issue 1 2003PETER C. BLOCK M.D. Mitral regurgitation (MR) associated with, ischemic, and degenerative (prolapse) disease, contributes to left ventricular (LV) dysfunction due to remodeling, and LV dilation, resulting in worsening of MR. Mitral valve (MV) surgical repair has provided improvement in survival, LV function and symptoms, especially when performed early. Surgical repair is complex, due to diverse etiologies and has significant complications. The Society for Thoracic Surgery database shows that operative mortality for a 1st repair is 2% and for re-do repair is 4 times that. Cardiopulmonary bypass and cardiac arrest are required. The attendant morbidity prolongs hospitalization and recovery. Alfieri simplified mitral repair using an edge-to-edge technique which subsequently has been shown to be effective for multiple etiologies of MR. The MV leaflers are typically brought together by a central suture producing a double orifice MV without stenosis. Umana reported that MR decreased from grade 3.6 +/,0.5 to0.8 +/,0.4 (P < 0.0001)and LV ejection fraction increased from 33 +/,13% to 45 +/,11%(P = 0.0156). In 121 patients, Maisano reported freedom from re-operation of 95 +/,4.8% with up to 6 year follow-up. Oz developed a MV "grasper" that is directly placed via a left ventriculotomy and coapts both leaflets which are then fastened by a graduated spiral screw. An in-vitro model using explanted human valves showed significant reduction in MR and in canine studies, animals followed by serial echo had persistent MV coaptation. At 12 weeks the device was endothelialized. These promising results have paved the way for a percutaneous or minimally invasive off pump mitral repair. Evalve has developed catheter-based technology, which, by apposing the edges of a regurgitant MV, results in edge-to-edge repair. Release of the device is done after echo and fluoroscopic evaluation under normal loading conditions. If the desired effect is not produced the device can be repositioned or retrieved. Animal studies show excellent healing, with incorporation of the device into the leaflets at 6,10 weeks with persistent coaptation. Another percutaneous approach has been to utilize the proximity of the coronary sinus (CS) to the mitral annulus (MA). Placement of a self-compressing device in the CS along the region of the posterior MA has, in canine models, reduced MR and addresses the issues of MA dilation and its contribution to MR. Ongoing studies are underway for both techniques. (J Interven Cardiol 2003;16:93,96) [source] Japan's First Robot-assisted Totally Endoscopic Mitral Valve Repair With a Novel Atrial RetractorARTIFICIAL ORGANS, Issue 10 2009Norihiko Ishikawa Abstract This case report presents the first robot-assisted totally endoscopic mitral valve plasty in Japan. A 54-year-old woman was found by echocardiography to have grade III mitral valve regurgitation because of prolapse of the posterior leaflet. Surgical repair was performed using the da Vinci Surgical System. For the totally endoscopic mitral valve repair, a right-sided approach was used through four ports. A transthoracic aortic cross-clamp and novel flexible port access retractor were inserted through a 5-mm skin incision. Quadrangular resection of the posterior leaflet was performed, and an annuloplasty band was placed into the atrium. Resection of the valve segment took 13 min, and band implementation, 45 min. The total pump time was 197 min and the aortic cross-clamp time, 117 min. Postoperative echocardiography confirmed the absence of mitral insufficiency. [source] Outcome of Pulmonary Valve Replacements in Adults after Tetralogy Repair: A Multi-institutional StudyCONGENITAL HEART DISEASE, Issue 3 2008Thomas P. Graham Jr. MD ABSTRACT Objective., The purpose of this study was to assess the outcome of pulmonary valve replacement (PVR) in adults with moderate/severe pulmonary regurgitation after tetralogy repair, with particular emphasis on patient outcome, durability of valve repair, and improvement in symptomatology. Design/Setting/Patients., The project committee of the International Society of Congenital Heart Disease undertook a retrospective multi-institutional analysis of PVR. Seven centers participated in submitting data on 93 patients >18 years of age who had the operation performed and follow-up obtained. The average age of PVR was 26± years (median 27 years). Time of follow-up after replacement was 3 years (range 4 days,28 years). Outcomes/Measures/Results., Kaplan,Meier estimates of durability of PVR showed approximately 50% replacement at 11 years. There were two deaths at 6 and 12 months after valve replacement. Right ventricular (RV) size estimated by echocardiography from pre- to postoperative studies decreased in 81% (P < 0.001 testing for equal proportions), but RV systolic function increased in only 36% (P = 0.09). Ability index improved in 59% (P < 0.001) and clinical heart failure status improved in 57% with this problem before PVR. PVR did not improve arrhythmia status in a small group of patients. Conclusions., PVR is associated with low mortality, decrease in RV size and improvement in ability index, and uncertain effects on RV systolic function. Average valve durability was approximately 11 years. Criteria for PVR that will preserve RV function are not clearly identified, and management of these patients remains a difficult enterprise. [source] Successful Repair of Aortic and Mitral Incompetence Induced by Methylsergide Maleate: Confirmation by Intraoperative Transesophageal EchocardiographyECHOCARDIOGRAPHY, Issue 3 2003D.O., Thomas Joseph Methylsergide maleate, an effective anti-migraine medication, has a well-documented association with left-sided cardiac valve dysfunction. Prior reports have described cardiac valve dysfunction in patients using methylsergide chronically for a minimum of 6 years, with surgical intervention consisting of valve replacement for patients with intractable congestive heart failure. We report a 51-year-old woman who developed severe mitral and aortic valvular dysfunction after taking methylsergide maleate for migraine headaches for a period of 19 months, and who subsequently underwent aortic and mitral valve repair with excellent short-term results. (ECHOCARDIOGRAPHY, Volume 20, April 2003) [source] Avecor Trillium Oxygenator Versus Noncoated Monolyth Oxygenator: A Prospective Randomized Controlled StudyJOURNAL OF CARDIAC SURGERY, Issue 4 2008Frédéric Vanden Eynden M.D. This study was designed to study the effects of the surface coating of a hollow fiber membrane oxygenator on coagulation, inflammation markers, and clinical outcomes. The biomaterials used to coat the membrane include heparin, polyethylene oxide chains (PEO), and sulfate/sulfonate groups. The coated membrane was compared to an uncoated oxygenator made of polypropylene. Methods: Two hundred patients who were scheduled to undergo valve repair and/or replacement surgery with or without coronary surgery were enrolled in the study. The patients were randomized to undergo CPB with either the Avecor oxygenator with TrilliumÔ (Medtronic, Minneapolis, MN, USA), a biopassive surface, or the Monolyth (Sorin, Irvine, CA, USA) oxygenator without coating. The primary and secondary endpoints were the differences between these oxygenators in regard to patients' biochemistry, coagulation profiles, inflammatory mediators, and clinical outcomes, including blood loss and neurological events. Results: There were no differences between the two groups in terms of biochemistry, coagulation profile, inflammatory mediator release, and blood loss. Five patients in the Avecor group showed clinical evidence of a stroke confirmed with computerized tomography (CT) scan imaging, and none in the noncoated oxygenator group. Conclusion: The oxygenator Avecor offers similar results in terms of inflammation and coagulation profiles and blood loss during valvular surgery compared to a standard uncoated control oxygenator. The rate of neurological events was unusually elevated in the former group of patients, with only speculative explanation at this point. Further studies are warranted to clarify this aspect. [source] Mitral Valve Repair in a Patient With Ter Haar SyndromeJOURNAL OF CARDIAC SURGERY, Issue 5 2006Semih Barlas M.D. Up to date only ten patients were reported. We present a living patient with ter Haar Syndrome who has undergone successful mitral valve repair. [source] Beating-Heart Valvular Surgery: A Possible Alternative for Patients with Severely Compromised Ventricular FunctionJOURNAL OF CARDIAC SURGERY, Issue 2 2002Richard J. Kaplon M.D. We report a novel approach to myocardial protection in a patient requiring multi-valve surgery who had an ejection fraction of 15%. Warm oxygenated blood was infused continuously both antegrade and retrograde during aortic valve replacement and mitral and tricuspid valve repair. Adequacy of perfusion was confirmed by the absence of electrocardiographic changes. Clinical improvement suggests that this strategy of myocardial protection warrants further investigation. [source] Partial Left Ventriculectomy and Limited Heart Transplantation AvailabilityJOURNAL OF CARDIAC SURGERY, Issue 2 2001Ph.D., sa Gradinac M.D. Background and Aim: Partial left ventriculectomy, a novel cardiac volume reduction operation, is applied in countries without a developed heart transplantation program. We sought to determine its impact in our population of patients. Methods: Partial left ventriculectomy was performed in 38 patients during the last 4 years. Basic inclusion criteria were nonischemic dilated cardiomyopathy and poor response to medical therapy for heart failure. Hemodynamic evaluation was carried out before and after operation. A modified surgical technique of mitral valve repair and ventricle suturing was applied. Results: Thirty-day, 6-month, and 2-year survival rates were 82%± 7%, 65%± 8%. and 61%± 9%, respectively. Duration of heart failure symptoms was the only predictor of survival (p = 0.042). A high proportion of noncardiac causes of death was noted. Functional capacity in surviving patients improved at every successive measurement up to 1 year postoperatively. Conclusions: The introduction of partial left ventriculectomy in a country with limited heart transplantation availability had a great impact on the management of end-stage heart failure and may represent the only surgical option for some patients. The average cost per patient was substantially lower when compared to heart transplantation. [source] Feasibility of Myxomatous Mitral Valve Repair Using Direct Leaflet and Chordal Radiofrequency AblationJOURNAL OF INTERVENTIONAL CARDIOLOGY, Issue 6 2008JEFFREY L. WILLIAMS M.D., M.S. Objective: Minimally invasive repair of mitral valve prolapse (MVP) causing severe mitral regurgitation (MR) should reduce MR and have chronic durability. Our ex vivo, acute in vivo, and chronic in vivo studies suggest that direct application of radiofrequency ablation (RFA) to mitral leaflets and chordae can effect these repair goals to decrease MR. Methods: A total of seven canines were studied to assess the effects of RFA on mitral valve structure and function. RFA was applied ex vivo (n = 1), acutely in vivo using a right lateral thoracotomy and cardiopulmonary bypass (n = 3), and chronically in vivo using percutaneous access to the heart (n = 3). RFA was applied to the mitral valve and its associated chordae. Mitral valve structure and function (in vivo preparations) were then assessed. Results: Ex vivo application of RFA resulted in qualitative reduction in mitral leaflet surface area and chordal length. Acute in vivo application of RFA to canines found to have MVP causing severe MR demonstrated a 43.7,60.7% statistically significant (P = 0.039) reduction in postablation MR. Chronic, in vivo, percutaneous application of RFA was found to be feasible and the engendered alterations durable. Conclusion: These data suggest that myxomatous mitral valve repair using radiofrequency energy delivered via catheter is feasible. [source] Advances in Heart Valve SurgeryJOURNAL OF INTERVENTIONAL CARDIOLOGY, Issue 6 2003MATTHIAS AAZAMI Heart valve surgery continues to evolve in a dynamic fashion. While the exact role of minimally invasive approaches still needs to be defined, progress has been made in the development of new bioprostheses and their durability. Most importantly, valve repair has been standardized for the mitral and introduced for the aortic valve with results that have been superior to valve replacement. Selection of the optimal procedure for the individual patient is now facilitated. In the future, a wider application of repair procedures and further improvements of biologic valves can be anticipated not only to influence long-term results but also the decision-making process for conservative or surgical treatment. (J Interven Cardiol 2003;16:535,541) [source] Japan's First Robot-assisted Totally Endoscopic Mitral Valve Repair With a Novel Atrial RetractorARTIFICIAL ORGANS, Issue 10 2009Norihiko Ishikawa Abstract This case report presents the first robot-assisted totally endoscopic mitral valve plasty in Japan. A 54-year-old woman was found by echocardiography to have grade III mitral valve regurgitation because of prolapse of the posterior leaflet. Surgical repair was performed using the da Vinci Surgical System. For the totally endoscopic mitral valve repair, a right-sided approach was used through four ports. A transthoracic aortic cross-clamp and novel flexible port access retractor were inserted through a 5-mm skin incision. Quadrangular resection of the posterior leaflet was performed, and an annuloplasty band was placed into the atrium. Resection of the valve segment took 13 min, and band implementation, 45 min. The total pump time was 197 min and the aortic cross-clamp time, 117 min. Postoperative echocardiography confirmed the absence of mitral insufficiency. [source] |