Valores De (valore + de)

Distribution by Scientific Domains


Selected Abstracts


Confronting Uncertainty and Missing Values in Environmental Value Transfer as Applied to Species Conservation

CONSERVATION BIOLOGY, Issue 5 2010
SONIA AKTER
conservación de especies; error de transferencia; incertidumbre; transferencia de valor ambiental; valores de no uso Abstract:,The nonuse (or passive) value of nature is important but time-consuming and costly to quantify with direct surveys. In the absence of estimates of these values, there will likely be less investment in conservation actions that generate substantial nonuse benefits, such as conservation of native species. To help overcome decisions about the allocation of conservation dollars that reflect the lack of estimates of nonuse values, these values can be estimated indirectly by environmental value transfer (EVT). EVT uses existing data or information from a study site such that the estimated monetary value of an environmental good is transferred to another location or policy site. A major challenge in the use of EVT is the uncertainty about the sign and size of the error (i.e., the percentage by which transferred value exceeds the actual value) that results from transferring direct estimates of nonuse values from a study to a policy site, the site where the value is transferred. An EVT is most useful if the decision-making framework does not require highly accurate information and when the conservation decision is constrained by time and financial resources. To account for uncertainty in the decision-making process, a decision heuristic that guides the decision process and illustrates the possible decision branches, can be followed. To account for the uncertainty associated with the transfer of values from one site to another, we developed a risk and simulation approach that uses Monte Carlo simulations to evaluate the net benefits of conservation investments and takes into account different possible distributions of transfer error. This method does not reduce transfer error, but it provides a way to account for the effect of transfer error in conservation decision making. Our risk and simulation approach and decision-based framework on when to use EVT offer better-informed decision making in conservation. Resumen:,El valor de no uso (o pasivo) de la naturaleza es importante pero su cuantificación con muestreos pasivos consume tiempo y es costosa. En ausencia de estimaciones de estos valores, es probable que haya menos inversión en acciones de conservación que generen beneficios de no uso sustanciales, tal como la conservación de especies nativas. Para ayudar a superar decisiones respecto a la asignación de dólares para conservación que reflejan la carencia de estimaciones de los valores de no uso, estos valores pueden ser estimados indirectamente por la transferencia de valor ambiental (TVA). La transferencia de valor ambiental utiliza datos existentes o información de un sitio de estudio de tal manera que el valor monetario estimado de un bien ambiental es transferido a otro sitio. Un reto mayor en el uso de TVA es la incertidumbre sobre la señal y el tamaño del error (i.e., el porcentaje en que el valor transferido excede al valor actual) que resulta de la transferencia de estimaciones directas de los valores de no uso de un sitio de estudio a uno político, el sitio adonde el valor es transferido. Una TVA es más útil si el marco de toma de decisiones no requiere información muy precisa y cuando la decisión de conservación está restringida por tiempo y recursos financieros. Para tomar en cuenta la incertidumbre en el proceso de toma de decisiones, se puede seguir una decisión heurística que guie el proceso de decisión e ilustre sobre las posibles ramificaciones de la decisión. Para tomar en cuenta la incertidumbre asociada con la transferencia de valores de un sitio a otro, desarrollamos un método de riesgo y simulación que utiliza simulaciones Monte Carlo para evaluar los beneficios netos de las inversiones de conservación y que considera posibles distribuciones diferentes de la transferencia de error. Este método no reduce el error de transferencia, pero proporciona una manera para considerar el efecto del error de transferencia en la toma de decisiones de conservación. Nuestro método de riesgo y simulación y el marco de referencia basado en decisones sobre cuando utilizar TVA permiten la toma de decisiones en conservación más informadas. [source]


Effects of lipid extraction on stable carbon and nitrogen isotope analyses of fish tissues: potential consequences for food web studies

ECOLOGY OF FRESHWATER FISH, Issue 3 2004
M. A. Sotiropoulos
Abstract,,, We examined whether solvent-based lipid extractions, commonly used for stable isotope analysis (SIA) of biota, alters ,15N or ,13C values of fish muscle tissue or whole juvenile fish. Lipid extraction from muscle tissue led to only small (<1,) isotope shifts in ,13C and ,15N values. By contrast, ecologically significant shifts (+3.4, for ,13C and +2.8, for ,15N) were observed for whole juvenile fish. Sample variance was not affected by lipid extraction. For tissue-specific SIA, two sample aliquots may be required: a lipid-extracted aliquot for stable carbon isotope analysis when differing lipid content among tissues is a concern, and a nonextracted aliquot for ,15N determination. Whole organism SIA is not recommended because of the mix of tissues having different turnover times; for very small fish, we recommend that fish be eviscerated, decapitated, and skinned to minimise differences with samples of muscle tissue. Resumen 1. Cada vez con mayor frecuencia, los ecólogos de peces utilizan análisis de isótopos estables. Por ello, se hace cada vez más importante comprender las fuentes de variación, - debido a diferencias inherentes entre muestreos biológicos o como resultado de técnicas de procesamiento de muestreo - tanto como identificar estrategias para tratar tales fuentes. Examinamos si la extracción de lípidos basada en disolventes, comúnmente utilizada en análisis de isótopos de carbono estable, altera negativamente los valores de ,15N y ,13C de tejido muscular de tres peces de tamaño pequeño y de peces juveniles completos. 2. La extracción de lípidos de músculo de pez llevó a pequeños cambios isotópicos de + +0.4 a +1.0, y de +0.3 a +0.5, para ,13C y ,15N, respectivamente. Por el contrario, la extracción de lípidos de peces juveniles completos varió marcadamente en +3.4, para ,13C y +2.8, para ,15N - ambos cambios ecológicamente importantes. La varianza de los valores de muestreos de ,13C y de ,15N tanto para tejido muscular como para los peces completos no difirieron entre los muestreos de lípidos extraídos y muestreos sin tratamiento. 3. Nuestros resultados recomiendan el análisis de isótopos estables de tejidos específicos. Cuando ello no es posible o deseable, dos alícuotas de muestreo pueden ser requeridas: una alícuota de lípidos extraídos para el análisis de isótopos de carbono estable cuando la varianza de ,13C, debida a diferencias en el contenido de lípidos de diferentes tejidos, y una alícuota de no-extracción para determinaciones de ,15N. 4. Dada la mezcla de tejidos, el análisis de isótopos de un organismo completo no es recomendable , en el caso de peces muy pequeños, recomendamos que los peces sean eviscerados, decapitados, y despellejados para minimizar las diferencias de muestreos de tejido muscular. [source]


Force transmission of one- and two-piece morse-taper oral implants: a nonlinear finite element analysis

CLINICAL ORAL IMPLANTS RESEARCH, Issue 4 2004
Murat Cavit Çehreli
Abstract Purpose: To compare force transmission behaviors of one-piece (1-P) and two-piece (2-P) morse-taper oral implants. Material and methods: A three-dimensional finite element model of a morse-taper oral implant and a solid abutment was constructed separately. The implant,abutment complex was embedded in a Ø 1.5 cm × 1.5 cm acrylic resin cylinder. Vertical and oblique forces of 50 N and 100 N were applied on the abutment and solved by two different analyses. First, contact analysis was performed in the implant,abutment complex to evaluate a 2-P implant. Then, the components were bonded with a separation force of 1020 N to analyze a 1-P implant. Results: Von Mises stresses in the implant, principal stresses, and displacements in the resin were the same for both designs under vertical loading. Under oblique loading, principal stresses and displacement values in the resin were the same, but the magnitudes of Von Mises stresses were higher in the 2-P implant. The principal stress distributions around both implants in the acrylic bone were similar under both loading conditions. Conclusion: 2-P implants experience higher mechanical stress under oblique loading. Nevertheless, the 1-P- or 2-P morse-taper nature of an implant is not a decisive factor for the magnitude and distribution of stresses, and displacements in supporting tissues. Résumé Le but de cette étude a été de comparer les comportements de la transmission de la force desimplants buccaux en deux pièces. Un modèle d'éléments finis tridimensionnels d'un implant buccal et d'un pilier solide ont été construits séparément. Le complexe implant/pilier a été enfoui dans un cylindre de résine acrylique d'un diamètre 1,5 × 1,5 cm. Des forces obliques et verticales de 50 et 100 N ont été appliquées sur les piliers et analysées par deux méthodes. D'abord, l'analyse de contraste a été effectuée dans le complexe implant/pilier pour évaluer un implant en deux pièces. Ensuite, les composants ont été reliés avec une force de séparation de 1020N pour analyser un implant en une pièce. Les stress de Von Mises dans l'implant, les principaux stress et les déplacements dans la résine étaient les mêmes pour les deux modèles sous charge verticale. Lorsqu'une charge oblique était appliquée, les stress principaux et les valeurs de déplacements dans la résine étaient semblables mais l'amplitude des stress de Von Mises était plus importante dans l'implant à deux pièces. Les distributions des stress principaux autour des deux implants dans l'os acrylique était semblable sous les deux conditions de charge. Les implants en deux pièces subissent un stress mécanique plus important sous une charge oblique. Cependant, l'implant en une ou deux pièces avec un cône morse n'est pas un facteur décisif sur l'amplitude et la distribution des stress, et les déplacements des tissus de support. Zusammenfassung Ziel: Die Kraftübertragungsverhältnisse von ein- und zweiteiligen oralen Implantaten mit konischem Sitz der Sekundärteile zu untersuchen. Material und Methode: Es wurde je ein separates dreidimensionales Finite Element Modell eines oralen Implantats mit konischem Sitz der Sekundärteile und ein Massivsekundärteil konstruiert. Der Implantat-Sekundärteilkomplex wurde in einem Zylinder aus Acryl mit Durchmesser 1.5cm und Länge 1.5cm eingebettet. Vertikale und schräge Kräfte von 50 N und 100 N wurden auf das Sekundärteil appliziert und durch zwei verschiedene Analysen ausgewertet. Zuerst wurde eine Kontaktanalyse im Implantat-Sekundärteilkomplex zur Auswertung eines zweiteiligen Implantats durchgeführt. Dann wurden die Komponenten mit einer Separationskraft von 1020 N verbunden, um ein einteiliges Implantat zu analysieren. Resultate: Unter vertikaler Belastung waren der Van Mises Stress im Implantat, der generelle Stress und die Displatzierung im Kunststoff für beide Konstruktionen gleich. Unter schräger Belastung waren der generelle Stress und die Displatzierungswerte im Kunststoff die gleichen, jedoch war das Ausmass des von Mises Stress im zweiteiligen Implantat grösser. Die generelle Stressverteilung im Akrylknochen um die Implantate war unter beiden Belastungsbedingungen ähnlich. Schlussfolgerung: Zweiteilige Implantate erleiden grösseren mechanischen Stress unter schräger Belastung. Jedoch ist die ein- oder zweiteilige Konstruktion mit konischem Sitz der Sekundärteile bei Implantaten kein entscheidender Faktor für das Ausmass und die Verteilung des Stresses und für die Displatzierung in den Verankerungsgeweben. Resumen Intención: Comparar los comportamientos de transmisión de fuerzas de implantes orales en cono morse de una o dos piezas. Material y métodos: Se construyeron separadamente un modelo tridimensional de elemento finito de un implante oral de cono morse y un pilar sólido. El complejo implante-pilar se embebió en un cilindro de resina acrílica de , 1.5 cm × 1.5 cm. Se aplicaron fuerzas oblicuas de 50 N y 100 N sobre el pilar y se resolvieron por medio de dos análisis diferentes. Primero, se llevó a cabo un análisis de contacto en el complejo implante-pilar para evaluar un implante de dos piezas. Después, se unieron los componentes con una fuerza de separación de 1020 N para analizar un implante de una sola pieza. Resultados: El estrés de Von Mises, el estrés principal, y el desplazamiento en la resina fueron los mismos para ambos diseños bajo carga vertical. Bajo carga oblicua, los valores de estrés principal y desplazamiento en resina fueron los mismos, pero la magnitud de los estreses de Von Mises fueron mayores en los implantes de dos piezas. Las distribuciones del estrés principal alrededor de ambos implantes in el hueso acrílico fueron similares bajo ambas condiciones de carga. Conclusión: Los implantes de dos piezas experimentan un estrés mecánico mas alto bajo carga oblicua. Sin embargo, la naturaleza de un implante de cono morse de una o dos piezas no es un factor decisivo en la magnitud y distribución de los estreses, y desplazamientos en los tejidos de soporte. [source]