Tip Catheter (tip + catheter)

Distribution by Scientific Domains


Selected Abstracts


Comparison of Cool Tip Versus 8-mm Tip Catheter in Achieving Electrical Isolation of Pulmonary Veins for Long-Term Control of Atrial Fibrillation: A Prospective Randomized Pilot Study

JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, Issue 10 2006
SANJAY DIXIT M.D.
Objective: To compare safety and efficacy of 8-mm versus cooled tip catheter in achieving electrical isolation (EI) of pulmonary veins (PV) for long-term control of atrial fibrillation (AF). Background: There is paucity of studies comparing safety/efficacy of 8-mm and cooled tip catheters in patients undergoing AF ablation. Methods and Results: This was a randomized and patient-blinded study. Subjects were followed by clinic visits (at 6 weeks and 6 months) and transtelephonic monitoring (3-week duration) done around each visit. Primary endpoints were: (1) long-term AF control (complete freedom and/or >90% reduction in AF burden on or off antiarrhythmic drugs at 6 months after a single ablation), and (2) occurrence of serious adverse events (cardiac tamponade, stroke, LA-esophageal fistula, and/or death). Eighty-two patients (age 56 ± 9 years, 60 males, paroxysmal AF = 59) were randomized (42 patients to 8-mm tip and 40 patients to cooled tip). EI of PVs was achieved in shorter time by the 8-mm tip as compared with cooled tip catheter (40 ± 23 minutes vs 50 ± 30 minutes; P < 0.05) but long-term AF control was not different between the two (32 patients [78%] vs 28 patients [70%], respectively; P = NS). One serious adverse event occurred in each group (LA-esophageal fistula and stroke, respectively) and no significant PV stenosis was observed in either. Conclusion: EI of PVs using either 8-mm or cooled tip catheter results in long-term AF control in the majority after a single ablation procedure, with comparable efficacy and safety. [source]


Esophageal Luminal Temperature Measurement Underestimates Esophageal Tissue Temperature During Radiofrequency Ablation Within the Canine Left Atrium: Comparison Between 8 mm Tip and Open Irrigation Catheters

JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, Issue 6 2008
JENNIFER E. CUMMINGS M.D.
Introduction: Evaluation of luminal temperature during left atrial ablation is used clinically; however, luminal temperature does not necessarily reflect temperature within the esophageal wall and poses a risk of atrioesophageal fistula. This animal study evaluates luminal esophageal temperature and its relation to the temperature of the external esophageal tissue during left atrial lesions using the 8 mm solid tip and the open irrigated tip catheters (OIC). Methods and Results: A thermocouple was secured to the external surface of the esophagus at the level of the left atrium of the dogs. Luminal esophageal temperature was measured using a standard temperature probe. In four randomized dogs, lesions were placed using an 8 mm solid tip ablation catheter. In six randomized dogs, lesions were placed using the 3.5 mm OIC. The average peak esophageal tissue temperature when using the OIC was significantly higher than that of the 8 mm tip catheter (88.6°C ± 15.0°C vs. 62.3°C ± 12.5°C, P < 0.05). Both OIC and 8 mm tip catheter had significantly higher peak tissue temperatures than luminal temperatures (OIC: 88.6°C ± 15.0°C vs 39.7°C ± 0.82°C, P < 0.05) (8 mm: 62.3°C ± 12.5°C vs 39.0 ± 0.5°C, P < 0.05). Both catheters achieved peak temperatures faster in the tissue as compared to the lumen of the esophagus, although the tissue temperature peaked significantly faster for the OIC (OIC: 25 seconds vs 90 seconds, P < 0.05) (8 mm: 63 seconds vs 105 seconds, P < 0.05). Conclusion: Despite the significant difference in actual tissue temperatures, no significant difference was observed in luminal temperatures between the OIC and 8 mm tip catheter. [source]


Comparison of Cool Tip Versus 8-mm Tip Catheter in Achieving Electrical Isolation of Pulmonary Veins for Long-Term Control of Atrial Fibrillation: A Prospective Randomized Pilot Study

JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, Issue 10 2006
SANJAY DIXIT M.D.
Objective: To compare safety and efficacy of 8-mm versus cooled tip catheter in achieving electrical isolation (EI) of pulmonary veins (PV) for long-term control of atrial fibrillation (AF). Background: There is paucity of studies comparing safety/efficacy of 8-mm and cooled tip catheters in patients undergoing AF ablation. Methods and Results: This was a randomized and patient-blinded study. Subjects were followed by clinic visits (at 6 weeks and 6 months) and transtelephonic monitoring (3-week duration) done around each visit. Primary endpoints were: (1) long-term AF control (complete freedom and/or >90% reduction in AF burden on or off antiarrhythmic drugs at 6 months after a single ablation), and (2) occurrence of serious adverse events (cardiac tamponade, stroke, LA-esophageal fistula, and/or death). Eighty-two patients (age 56 ± 9 years, 60 males, paroxysmal AF = 59) were randomized (42 patients to 8-mm tip and 40 patients to cooled tip). EI of PVs was achieved in shorter time by the 8-mm tip as compared with cooled tip catheter (40 ± 23 minutes vs 50 ± 30 minutes; P < 0.05) but long-term AF control was not different between the two (32 patients [78%] vs 28 patients [70%], respectively; P = NS). One serious adverse event occurred in each group (LA-esophageal fistula and stroke, respectively) and no significant PV stenosis was observed in either. Conclusion: EI of PVs using either 8-mm or cooled tip catheter results in long-term AF control in the majority after a single ablation procedure, with comparable efficacy and safety. [source]


Cooled Needle Catheter Ablation Creates Deeper and Wider Lesions Than Irrigated Tip Catheter Ablation

JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, Issue 5 2005
ARAVINDA THIAGALINGAM F.R.A.C.P.
Objectives: To design and test a catheter that could create deeper ablation lesions. Background: Endocardial radiofrequency (RF) ablation is unable to reliably create transmural ventricular lesions. We designed an intramural needle ablation catheter with an internally cooled 1.1-mm diameter straight needle that could be advanced up to 14 mm into the myocardium. The prototype catheter was compared with an irrigated tip ablation catheter. Methods: Ablation lesions were created under general anesthesia in 14 male sheep (weight 44 ± 7.3 kg) with fluoroscopic guidance. Each of the catheters was used to create two ablation lesions at randomly allocated positions within the left ventricle. The irrigation rate, target temperature, and maximum power were: 20 mL/min, 85°C, 50 W for the intramural needle catheter and 20 mL/min, 50°C, 50 W for the irrigated tip catheter, respectively. All ablations were performed for 2 minutes. After the last ablation, blue tetrazolium (12.5 mg/kg) was infused intravenously. The heart was removed via a left thoracotomy after monitoring the sheep for one hour. Results: There was no evidence of cardiac tamponade in any sheep. The intramural needle catheter lesions were significantly wider (10.9 ± 2.8 mm vs 10.1 ± 2.4 mm, P = 0.01), deeper (9.6 ± 2.0 mm vs 7.0 ± 1.3 mm, P = 0.01), and more likely to be transmural (38% vs 0%, P = 0.03). Conclusions: Cooled intramural needle ablation creates lesions that are significantly deeper and wider than endocardial RF ablation using an irrigated tip catheter in sheep hearts. This technology may be useful in treating ventricular tachycardia resistant to conventional ablation techniques. [source]


The effect of fundal pressure manoeuvre on intrauterine pressure in the second stage of labour

BJOG : AN INTERNATIONAL JOURNAL OF OBSTETRICS & GYNAECOLOGY, Issue 5 2002
Catalin S. Buhimschi
Objective To investigate the relationship between intrauterine pressure and the application of a standardised fundal pressure manoeuvre, and to determine the maternal, fetal and labour characteristics that modulate the relationship. Design Prospective measurement of intrauterine pressure during the second stage of labour. Setting North American university hospital. Population Forty full-term women in spontaneous labour were studied during the second stage. Each woman acted as her own control. All women laboured with requested epidural analgesia. Methods A fundal pressure manoeuvre was performed so as to standardise the level of force and the surface area of application. Intrauterine pressure was measured using a sensor,tip catheter. Five interventions were analysed: 1. valsalva during a uterine contraction; 2. fundal pressure and valsalva during a contraction; 3. fundal pressure during a contraction without valsalva; 4. fundal pressure in the absence of uterine contractions; and 5. valsalva in the absence of uterine contractions. Results Women in the second stage of labour transiently increased their expulsive force (as reflected by intrauterine pressure) by 86% of their baseline contraction using valsalva and fundal pressure simultaneously. The efficiency by which both contraction-enhancing manoeuvres increased intrauterine pressure was directly related to gestational age and inversely related to myometrial thickness. Conclusion Fundal pressure applied under controlled conditions significantly increases intrauterine pressure in some, but not all women. Simultaneous measurement of intrauterine pressure, to maintain feedback during application will create a ,controlled environment' for the obstetrician and reassurance that this manoeuvre can be applied in a controlled fashion. Future delineation of the group of women that could benefit from fundal pressure, as well as the group that is refractory is essential to avoid unnecessary or delayed operative interventions. [source]


Esophageal Luminal Temperature Measurement Underestimates Esophageal Tissue Temperature During Radiofrequency Ablation Within the Canine Left Atrium: Comparison Between 8 mm Tip and Open Irrigation Catheters

JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, Issue 6 2008
JENNIFER E. CUMMINGS M.D.
Introduction: Evaluation of luminal temperature during left atrial ablation is used clinically; however, luminal temperature does not necessarily reflect temperature within the esophageal wall and poses a risk of atrioesophageal fistula. This animal study evaluates luminal esophageal temperature and its relation to the temperature of the external esophageal tissue during left atrial lesions using the 8 mm solid tip and the open irrigated tip catheters (OIC). Methods and Results: A thermocouple was secured to the external surface of the esophagus at the level of the left atrium of the dogs. Luminal esophageal temperature was measured using a standard temperature probe. In four randomized dogs, lesions were placed using an 8 mm solid tip ablation catheter. In six randomized dogs, lesions were placed using the 3.5 mm OIC. The average peak esophageal tissue temperature when using the OIC was significantly higher than that of the 8 mm tip catheter (88.6°C ± 15.0°C vs. 62.3°C ± 12.5°C, P < 0.05). Both OIC and 8 mm tip catheter had significantly higher peak tissue temperatures than luminal temperatures (OIC: 88.6°C ± 15.0°C vs 39.7°C ± 0.82°C, P < 0.05) (8 mm: 62.3°C ± 12.5°C vs 39.0 ± 0.5°C, P < 0.05). Both catheters achieved peak temperatures faster in the tissue as compared to the lumen of the esophagus, although the tissue temperature peaked significantly faster for the OIC (OIC: 25 seconds vs 90 seconds, P < 0.05) (8 mm: 63 seconds vs 105 seconds, P < 0.05). Conclusion: Despite the significant difference in actual tissue temperatures, no significant difference was observed in luminal temperatures between the OIC and 8 mm tip catheter. [source]


Comparison of Cool Tip Versus 8-mm Tip Catheter in Achieving Electrical Isolation of Pulmonary Veins for Long-Term Control of Atrial Fibrillation: A Prospective Randomized Pilot Study

JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, Issue 10 2006
SANJAY DIXIT M.D.
Objective: To compare safety and efficacy of 8-mm versus cooled tip catheter in achieving electrical isolation (EI) of pulmonary veins (PV) for long-term control of atrial fibrillation (AF). Background: There is paucity of studies comparing safety/efficacy of 8-mm and cooled tip catheters in patients undergoing AF ablation. Methods and Results: This was a randomized and patient-blinded study. Subjects were followed by clinic visits (at 6 weeks and 6 months) and transtelephonic monitoring (3-week duration) done around each visit. Primary endpoints were: (1) long-term AF control (complete freedom and/or >90% reduction in AF burden on or off antiarrhythmic drugs at 6 months after a single ablation), and (2) occurrence of serious adverse events (cardiac tamponade, stroke, LA-esophageal fistula, and/or death). Eighty-two patients (age 56 ± 9 years, 60 males, paroxysmal AF = 59) were randomized (42 patients to 8-mm tip and 40 patients to cooled tip). EI of PVs was achieved in shorter time by the 8-mm tip as compared with cooled tip catheter (40 ± 23 minutes vs 50 ± 30 minutes; P < 0.05) but long-term AF control was not different between the two (32 patients [78%] vs 28 patients [70%], respectively; P = NS). One serious adverse event occurred in each group (LA-esophageal fistula and stroke, respectively) and no significant PV stenosis was observed in either. Conclusion: EI of PVs using either 8-mm or cooled tip catheter results in long-term AF control in the majority after a single ablation procedure, with comparable efficacy and safety. [source]


Cavotricuspid Isthmus Ablation with Large-Tip Gold Alloy Versus Platinum-Iridium-Tip Electrode Catheters

PACING AND CLINICAL ELECTROPHYSIOLOGY, Issue 2009
ATTILA KARDOS M.D., Ph.D.
Background: Gold has excellent electrical conductive properties and creates deeper and wider lesions than platinum-iridium during radiofrequency (RF) ablation in vitro. We tested the maximum voltage-guided technique (MVGT) of cavotricuspid isthmus (CTI) ablation using two 8-mm tip catheters containing gold (group G) or platinum-iridium (group PI). Methods: We enrolled 31 patients who underwent CTI ablation. In group G (n = 15) CTI ablation was performed with a gold-tip ablation catheter, while in group PI (n = 16) a platinum-iridium tip was used. Ablation was guided by CTI potentials with the highest amplitude until achievement of bidirectional block (BIB). If BIB was not achieved after 10 RF applications, RF was delivered via a 3.5-mm irrigated-tip catheter. Success rate, procedure duration, duration of fluoroscopic exposure, and number of RF applications were measured. Results: BIB was achieved in all patients in group G, while in group PI an irrigated tip was used in four patients (0% vs 25%, P < 0.001). These four patients required a total of 21 additional RF applications (5.25 ± 2.22). Procedure time (56.4 ± 12 vs 73.1 ± 15 minutes P < 0.05) and fluoroscopic explosure (4.9 ± 2.3 vs 7.1 ± 3.8 minutes, P < 0.01) were shorter in group G than in group PI. Mean number of RF applications was lower (4.6 ± 1.9 vs 6.6 ± 3.1 P < 0.001) and total RF duration shorter (280 ± 117 vs 480 ± 310 seconds) in group G than in group PI. No difference was observed in the number of recurrences at a 6 month-follow up (1 in group G vs 1 in group PI). Conclusion: Using the MVGT of CTI ablation, gold-tip catheters were associated with shorter procedural and fluoroscopic times, and fewer RF applications. [source]