Surface-enhanced Laser Desorption/ionization (surface-enhanced + laser_ionization)

Distribution by Scientific Domains


Selected Abstracts


Peak quantification in surface-enhanced laser desorption/ionization by using mixture models

PROTEINS: STRUCTURE, FUNCTION AND BIOINFORMATICS, Issue 19 2006
Martijn Dijkstra
Abstract Surface-enhanced laser desorption/ionization (SELDI) time of flight (TOF) is a mass spectrometry technology for measuring the composition of a sampled protein mixture. A mass spectrum contains peaks corresponding to proteins in the sample. The peak areas are proportional to the measured concentrations of the corresponding proteins. Quantifying peak areas is difficult for existing methods because peak shapes are not constant across a spectrum and because peaks often overlap. We present a new method for quantifying peak areas. Our method decomposes a spectrum into peaks and a baseline using so-called statistical finite mixture models. We illustrate our method in detail on 8 samples from culture media of adipose tissue and globally on 64 samples from serum to compare our method to the standard Ciphergen method. Both methods give similar estimates for singleton peaks, but not for overlapping peaks. The Ciphergen method overestimates the heights of such peaks while our method still gives appropriate estimates. Peak quantification is an important step in pre-processing SELDI-TOF data and improvements therein will pay off in the later biomarker discovery phase. [source]


Oncoproteomics of hepatocellular carcinoma: from cancer markers' discovery to functional pathways

LIVER INTERNATIONAL, Issue 8 2007
Stella Sun
Abstract Hepatocellular carcinoma (HCC) is a heterogeneous cancer with no promising treatment and remains one of the most prevailing and lethal malignancies in the world. Researchers in many biological areas now routinely identify and characterize protein markers by a mass spectrometry-based proteomic approach, a method that has been commonly used to discover diagnostic biomarkers for cancer detection. The proteomic research platforms span from the classical two-dimensional polyacrylamide gel electrophoresis (2-DE) to the latest Protein Chip or array technology, which are often integrated with the MALDI (matrix-assisted laser-desorption ionization), SELDI (surface-enhanced laser desorption/ionization) or tandem mass spectrometry (MS/MS). New advances on quantitative proteomic analysis (e.g. SILAC, ICAT, and ITRAQ) and multidimensional protein identification technology (MudPIT) have greatly enhanced the capability of proteomic methods to study the expressions, modifications and functions of protein markers. The present article reviews the latest proteomic development and discovery of biomarkers in HCC that may provide insights into the underlying mechanisms of hepatocarcinogenesis and the readiness of biomarkers for clinical uses. [source]


Peak quantification in surface-enhanced laser desorption/ionization by using mixture models

PROTEINS: STRUCTURE, FUNCTION AND BIOINFORMATICS, Issue 19 2006
Martijn Dijkstra
Abstract Surface-enhanced laser desorption/ionization (SELDI) time of flight (TOF) is a mass spectrometry technology for measuring the composition of a sampled protein mixture. A mass spectrum contains peaks corresponding to proteins in the sample. The peak areas are proportional to the measured concentrations of the corresponding proteins. Quantifying peak areas is difficult for existing methods because peak shapes are not constant across a spectrum and because peaks often overlap. We present a new method for quantifying peak areas. Our method decomposes a spectrum into peaks and a baseline using so-called statistical finite mixture models. We illustrate our method in detail on 8 samples from culture media of adipose tissue and globally on 64 samples from serum to compare our method to the standard Ciphergen method. Both methods give similar estimates for singleton peaks, but not for overlapping peaks. The Ciphergen method overestimates the heights of such peaks while our method still gives appropriate estimates. Peak quantification is an important step in pre-processing SELDI-TOF data and improvements therein will pay off in the later biomarker discovery phase. [source]


Mass spectrometry for the detection of differentially expressed proteins: a comparison of surface-enhanced laser desorption/ionization and capillary electrophoresis/mass spectrometry

RAPID COMMUNICATIONS IN MASS SPECTROMETRY, Issue 2 2004
Nils v. Neuhoff
The discovery of biomarkers is currently attracting much interest as it harbors great potential for the diagnosis and monitoring of human diseases. Here we have used two advanced mass spectroscopy based technologies, surface enhanced laser desorption ionization (SELDI-MS) and capillary electrophoresis/mass spectrometry (CE/MS), to obtain proteomic patterns of urine samples from patients suffering from membranous glomerulonephritis (MGN) and healthy volunteers. The results indicate that CE/MS analysis is able to display a rich and complex pattern of polypeptides with high resolution and high mass accuracy. In order to analyze these patterns, the MosaiqueVisu software was developed for peak identification, deconvolution and the display of refined maps in a three-dimensional format. The polypeptide profiles obtained with SELDI-MS from the same samples are much sparser and show lower resolution and mass accuracy. The SELDI-MS profiles are further heavily dependent on analyte concentration. SELDI-MS analysis identified three differentially expressed polypeptides, which are potential biomarkers that can distinguish healthy donors from patients with MGN. In contrast, approximately 200 potential biomarkers could be identified by CE/MS. Thus, while SELDI-MS is easy to use and requires very little sample, CE/MS generates much richer data sets that enable an in-depth analysis. Copyright © 2003 John Wiley & Sons, Ltd. [source]