Home About us Contact | |||
Subject Samples (subject + sample)
Selected AbstractsIntra- and intermuscular variation in human quadriceps femoris architecture assessed in vivoJOURNAL OF ANATOMY, Issue 3 2006Anthony J. Blazevich Abstract Despite the functional importance of the human quadriceps femoris in movements such as running, jumping, lifting and climbing, and the known effects of muscle architecture on muscle function, no research has fully described the complex architecture of this muscle group. We used ultrasound imaging techniques to measure muscle thickness, fascicle angle and fascicle length at multiple regions of the four quadriceps muscles in vivo in 31 recreationally active, but non-strength-trained adult men and women. Our analyses revealed a reasonable similarity in the superficial quadriceps muscles, which is suggestive of functional similarity (at least during the uni-joint knee extension task) given that they act via a common tendon. The deep vastus intermedius (VI) is architecturally dissimilar and therefore probably serves a different function(s). Architecture varies significantly along the length of the superficial muscles, which has implications for the accuracy of models that assume a constant intramuscular architecture. It might also have consequences for the efficiency of intra- and intermuscular force transmission. Our results provide some evidence that subjects with a given architecture of one superficial muscle, relative to the rest of the subject sample, also have a similar architecture in other superficial muscles. However, this is not necessarily true for vastus lateralis (VL), and was not the case for VI. Therefore, the relative architecture of one muscle cannot confidently be used to estimate the relative architecture of another. To confirm this, we calculated a value of whole quadriceps architecture by four different methods. Regardless of the method used, we found that the absolute or relative architecture of one muscle could not be used as an indicator of whole quadriceps architecture, although vastus medialis, possibly in concert with VL and the anterior portion of VI, could be used to provide a useful snapshot. Importantly, our estimates of whole quadriceps architecture show a gender difference in whole quadriceps muscle thickness, and that muscle thickness is positively correlated with fascicle angle whereas fascicle length is negatively, although weakly, correlated with fascicle angle. These results are supportive of the validity of estimates of whole quadriceps architecture. These data are interpreted with respect to their implications for neural control strategies, region-specific adaptations in muscle size in response to training, and gender-dependent differences in the response to exercise training. [source] Periodontal conditions in male adolescents using smokeless tobacco (moist snuff)JOURNAL OF CLINICAL PERIODONTOLOGY, Issue 12 2006Ulrika Montén Abstract Aim: The aim of this study was to evaluate the potential association of the use of smokeless tobacco (moist snuff) on the periodontal conditions of adolescents. Material and methods: A subject sample of one hundred and three 19-year-old male individuals (33 snuff users, 70 controls) living in Göteborg, Sweden, were clinically examined with regard to oral hygiene, gingivitis, probing pocket depth (PPD), clinical attachment loss (CAL) and gingival recession. Bitewing radiographs were obtained for assessments of alveolar bone level. Information about tobacco and oral hygiene habits was obtained by a structured questionnaire. Student 's t -test, ,2 -test and logistic regression analysis were used for statistical analysis. Results: The mean plaque and gingivitis scores in snuff-users were 59% (SD 21.0) and 47% (18.6), respectively, and in controls 64% (22.4) and 50% (18.3), respectively. The average PPD and CAL in snuff-users amounted to 2.3 mm (0.3) and 0.2 mm (0.1), respectively, and in controls 2.4 mm (0.3) and 0.1 mm (0.1) (p>0.05), respectively. The mean bone level was 1.3 mm (0.2) in both groups. The prevalence of subjects showing recession was 42% among snuff-users and 17% among controls (p=0.006). In snuff users, an average of 4% (0.9) of the teeth showed recession, compared with 1% (0.3) in controls (p<0.001). Limiting the analysis to the maxillary anterior tooth region, 33% of the snuff-users and 10% of the controls presented recessions (p=0.002). The use of snuff entailed an OR=5.1 to have gingival recessions. Conclusion: In the present population sample of adolescents, the use of smokeless tobacco (moist snuff) was not associated with the presence of periodontal disease except for a significantly high prevalence of gingival recessions. [source] Determination of levetiracetam in human plasma by liquid chromatography/electrospray tandem mass spectrometry and its application to bioequivalence studiesRAPID COMMUNICATIONS IN MASS SPECTROMETRY, Issue 17 2006Deepak S. Jain The first liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for the determination of levetiracetam, an antiepileptic drug, in human plasma is described. The plasma filtrate obtained after solid-phase extraction (SPE), using a polymer-based, hydrophilic-lipophilic balanced (HLB) cartridge, was submitted directly to a short column LC/MS/MS assay. There was no significant matrix effect on the analysis. For validation of the method, the recovery of the free analytes was compared to that from an optimized extraction method, and the analyte stability was examined under conditions mimicking sample storage, handling, and analytical procedures. The extraction procedure yielded extremely clean extracts with a recovery of 79.95% and 89.02% for levetiracetam and the internal standard (IS), respectively. The intra-assay and inter-assay precision for the samples at the lower limit of quantitation (LLOQ) were 6.33 and 6.82%, respectively. The calibration curves were linear for the dynamic range of 0.5 to 50,µg/mL with a correlation coefficient r,,,0.9971. The intra-assay accuracy at LLOQ, LQC, MQC, and HQC levels ranged from 81.60 to 95.40, 93.00 to 103.47, 95.97 to 104.09, and 91.15 to 95.18%, respectively, while the inter-assay accuracy at LLOQ, LQC, MQC and HQC levels varied from 80.20 to 95.40, 88.53 to 107.53, 95.97 to 108.45, and 91.15 to 112.70%, respectively. The method is rugged and fast with a total instrumental run time of 2,min. The method was successfully applied for bioequivalence studies in human subject samples after oral administration of 1000,mg immediate release (IR) formulations. Copyright © 2006 John Wiley & Sons, Ltd. [source] Sex differences in vocal patterns in the northern muriqui (Brachyteles hypoxanthus)AMERICAN JOURNAL OF PRIMATOLOGY, Issue 2 2010Luisa F. Arnedo Abstract We investigated whether sex differences in spatial dynamics correlate with rates of staccato and neigh vocalizations in northern muriquis (Brachyteles hypoxanthus) at the Reserva Particular do Patrimônio Natural,Feliciano Miguel Abdala, Minas Gerais, Brazil. A total of 2,727 10,min focal subject samples were collected on 32 adult females and 31 adult males between April 2007 and March 2008. Compared with males, females spent a significantly lower proportion of their time in proximity to other group members and gave staccatos at significantly higher rates while feeding, resting, and traveling. Conversely, males emitted neigh vocalizations at significantly higher rates than females when feeding and resting only. Both sexes gave significantly more staccatos when feeding than when they were engaged in other activities, but their respective rates of neighs did not vary across activities. Both females and males emitted staccato vocalizations at significantly higher rates during times of the year when preferred foods were scarce, but no seasonal differences in the rates of neigh vocalizations were observed in either sex. Females and males showed a reduction in the number of neighbors following staccato vocalizations and an increase in the number of neighbors following neigh vocalizations. Our findings of sex differences in the rates of staccato and neigh vocalizations and the effects of these vocalizations on interindividual spacing are consistent with sex differences in spatial dynamics, and confirm the role of vocal communication in mediating spatial associations in this species. Am. J. Primatol. 72:122,128, 2010. © 2009 Wiley-Liss, Inc. [source] A validated new method for nevirapine quantitation in human plasma via high-performance liquid chromatographyBIOMEDICAL CHROMATOGRAPHY, Issue 1 2006Courtney F. Silverthorn Abstract A fully validated and clinically relevant assay was developed for the assessment of nevirapine concentrations in neonate blood plasma samples. Solid-phase extraction with an acid,base wash series was used to prepare subject samples for analysis. Samples were separated by high performance liquid chromatography and detected at 280 nm on a C8 reverse-phase column in an isocratic mobile phase. The retention times of nevirapine and its internal standard were 5.0 and 6.9 min, respectively. The method was validated by assessment of accuracy and precision (statistical values <15%), specificity, and stability. The assay was linear in the range 25,10,000 ng[sol ]mL (r2 > 0.996) and the average recovery was 93% (n = 18). The lower limit of quantification (relative standard deviation <20%) was determined to be 25 ng[sol ]mL for 50 µL of plasma, allowing detection of as little as 1.25 ng of nevirapine in a sample. This value represents an increase in sensitivity of up to 30-fold over previously published methods. Copyright © 2005 John Wiley & Sons, Ltd. [source] Simultaneous quantitative determination of cyclosporine A and its three main metabolites (AM1, AM4N and AM9) in human blood by liquid chromatography/mass spectrometry using a rapid sample processing methodRAPID COMMUNICATIONS IN MASS SPECTROMETRY, Issue 5 2006Nozomu Koseki We have developed a sensitive and specific liquid chromatography/mass spectrometry (LC/MS) method for the simultaneous determination of cyclosporine A (CsA) and its three main metabolites (AM1, AM4N and AM9) in human blood. Following protein precipitation, supernatant was directly injected into the LC/MS system. Chromatographic separation was accomplished on a Symmetry C8 (4.6,×,75,mm, 3.5,µm) column with a linear gradient elution prior to detection by atmospheric pressure chemical ionization (APCI) MS using selected ion monitoring (SIM) in positive mode. This method can be applied to single mass equipment. The analytical range for each analyte was set at 1,2500,ng/mL using 100,µL of blood sample. The analytical method was fully validated according to FDA guidance. Intra-day mean accuracy and precision were 95.2,113.5% and 0.9,8.9%, respectively. Inter-day mean accuracy and precision were 95.8,107.0% and 1.5,10.7%, respectively. In blood all analytes were stable during three freeze/thaw cycles, for 24,h at room temperature and for 12 months at or below ,15°C. Stability was also confirmed in processed samples for 24,h at 10°C and for 6 months at 4°C in methanol. In addition, we confirmed the method could avoid matrix effects from transplant subjects' samples. This LC/MS technique provided an excellent method for simultaneous quantitative determination of CsA and its three metabolites for evaluation of their pharmacokinetic profiles. Copyright © 2006 John Wiley & Sons, Ltd. [source] |