Home About us Contact | |||
Stenosis Severity (stenosis + severity)
Selected AbstractsInitial feasibility of a multi-station high resolution three-dimensional dark blood angiography protocol for the assessment of peripheral arterial diseaseJOURNAL OF MAGNETIC RESONANCE IMAGING, Issue 4 2009Georgeta Mihai PhD Abstract Purpose To evaluate the feasibility of a multi-station three dimensional (3D) T1-weighted turbo spin echo (TSE) dark-blood Sampling Perfection with Application optimized Contrasts using different flip angle Evolution sequence (T1w-SPACE), to assess aorta, iliac, and superficial femoral (SFA) arteries (inflow vessels) by comparing it with a multi-station contrast enhanced MR angiography (CE-MRA) with identical resolution. Materials and Methods A total of 6 volunteers and 14 peripheral arterial disease (PAD) patients were included in the study. Abdominal and thigh T1w-SPACE and lower leg time-resolved MRA (TR-MRA) with low dose contrast were followed by 3-station CE-MRA. Quantitative measurements of lumen area at 17 locations from T1w-SPACE and CE-MRA were obtained. Additionally, vessel wall areas at the same locations were obtained from the T1w-SPACE images. Results Quantitative comparison of lumen areas with T1w-SPACE and CE-MRA revealed strong correlation between the two techniques and strong inter-observer agreement for each of the two imaging methods (r > 0.9; P < 0.001). Localized vessel wall area measurements obtained in PAD patients were significantly greater compared with those obtained in normal volunteers (mean difference 43.75 ± 12.46 mm2; P < 0.001). Stenosis severity obtained from T1w-SPACE localized measurements showed significant arterial area stenosis in PAD patients. Conclusion T1w-SPACE imaging of inflow vessels is feasible, and in addition to CE-MRA has the ability to assess atherosclerotic plaque and vascular remodeling. J. Magn. Reson. Imaging 2009;30:785,793. © 2009 Wiley-Liss, Inc. [source] Validation of the Clinical COPD Questionnaire as a psychophysical outcome measure in adult laryngotracheal stenosisCLINICAL OTOLARYNGOLOGY, Issue 4 2009S.A.R. Nouraei Objectives:, To validate the Clinical Chronic Obstructive Pulmonary Disease Questionnaire (CCQ), a patient-administered instrument developed for bronchopulmonary disease as a disease-specific psychophysical outcome measure for adult laryngotracheal stenosis. Design:, Prospective observational study. Settings:, Tertiary/National referral airway reconstruction centre. Participants:, Thirty-three tracheostomy-free patients undergoing endoscopic laryngotracheoplasty. Main outcome measures:, CCQ and the Medical Research Council (MRC) Dyspnoea scale, a previously validated but more limited scale, were administered to patients 2 weeks before surgery, preoperatively, and 2 weeks after endoscopic laryngotracheoplasty. Pulmonary function was assessed preoperatively. Internal consistency was assessed with Cronbach , statistics and test,retest reliability was determined using intraclass correlation. Correlations between CCQ and MRC scale, and pulmonary function were used to assess convergent and divergent validity respectively. Instrument responsiveness was assessed by correlating total and domain-specific CCQ scores with anatomical disease severity and post-treatment effect size. Results:, There were 12 males and 21 females. Mean age was 44 ± 15 years. Cronbach , coefficient and intraclass correlation coefficient were 0.88 and 0.95 respectively. Total and domain-specific CCQ scores significantly correlated with the MRC scores (P < 0.001) and significant correlations between CCQ and peak expiratory flow rate and FEV1 were identified (P < 0.03). There were statistically significant changes in total and domain-specific CCQ scores when different stenosis severities were compared. Clinical COPD Questionnaire scores also changed significantly and congruently following surgery (P < 0.05 in both cases). Discussion:, Clinical COPD Questionnaire is a valid and sensitive instrument for assessing symptom severity and levels of function and well-being in adult patients with laryngotracheal stenosis and can be used as a patient-centred disease-specific outcome measure for this condition. [source] Is Left Ventricular Diastolic Thickening Documented During Dobutamine and Pacing Stress Echocardiography Related to Myocardial Ischemia?ECHOCARDIOGRAPHY, Issue 1 2002An Animal Model Study Transient increase in diastolic wall thickness (pseudohypertrophy) during pacing stress echocardiography has been reported in normal myocardium. To evaluate the occurrence of pseudohypertrophy and to investigate the contribution of myocardial ischemia on its production during pacing and dobutamine stress echocardiography, we produced a physiologically significant coronary stenosis in 14 open chest dogs. The stenosis in the circumflex artery was measured by quantitative coronary angiography (range: 50% to 89% reduction in luminal diameter), and no resting segmental wallmotion abnormalities were observed by epicardial echocardiography (short-axis, papillary level). In each study, dobutamine (5,40 ,g/kg/min) and pacing (up to 260 beats/min) were performed randomly. Positivity of stress echocardiography tests was quantitatively determined by a significant (P < 0.05) reduction or failure to increase in absolute and percent systolic wall thickening in the myocardial area supplied by the stenotic artery as compared to the left anterior descending (LAD) artery-related areas. Diastolic wall thickness and left ventricular diastolic area were compared before and after each stress test in the circumflex and LAD artery-related regions. Pseudohypertrophy was observed in 57% and 86% of dogs for pacing and dobutamine, respectively, in the circumflex region, and in 50% and 64% in the LAD region. Despite its increased incidence in the circumflex region, the augmented diastolic wall thickness did not correlate with coronary stenosis severity or stress test positivity, but correlated inversely with changes in left ventricular diastolic area. In addition, it correlated directly with changes in heart rate only for pacing. In conclusion, pseudohypertrophy was a frequent finding during pacing and dobutamine stress echocardiography tests but was not related to myocardial ischemia in this animal model. [source] Protected Carotid Stenting in High-Risk Patients: Results of the SpideRX Arm of the Carotid Revascularization with ev3 Arterial Technology Evolution TrialJOURNAL OF INTERVENTIONAL CARDIOLOGY, Issue 5 2010ROBERT D. SAFIAN M.D. Purpose:,A prospective nonrandomized multicenter registry of 160 patients with severe carotid stenosis and high-risk features for carotid endarterectomy was conducted during the 3-month period from March to May 2005. Methods:,Carotid artery stenting (CAS) was performed with the SpideRXÔ Embolic Protection System (ev3, Inc., Plymouth, MN, USA) as part of an investigational device exemption from the Food and Drug Administration. Results:,The primary end-point of major adverse cardiac and cerebrovascular events at 30 days after CAS was observed in nine patients (5.6%), including death in four patients (2.5%), nonfatal stroke in five patients (3.1%), and nonfatal myocardial infarction in one patient (0.6%). A secondary end-point of technical success (defined as successful deployment of all devices, filter retrieval, and final diameter stenosis <50%) was achieved in 156 of 160 patients (97.5%). The only independent predictor of death or stroke at 30 days was baseline stenosis severity (P < 0.05). Conclusion:,CAS with distal embolic protection using the SpideRXÔ Embolic Protection System is a reasonable alternative for revascularization of some high-risk patients with severe carotid stenosis. (J Interven Cardiol 2010;23:491,498) [source] The Accuracy of Transcranial Doppler in the Diagnosis of Stenosis or Occlusion of the Terminal Internal Carotid ArteryJOURNAL OF NEUROIMAGING, Issue 4 2004Jose C. Navarro MD ABSTRACT Background and Purpose. Transcranial Doppler (TCD) can detect intracranial stenoses and occlusions that can help in the diagnosis and management of ischemic stroke. The accuracy parameters for lesions located in the terminal internal carotid artery (TICA) are less known, unlike other basal cerebral vessels. Patients and Methods. The authors studied consecutive patients referred for TCD who underwent contrast angiography or magnetic resonance angiography. They calculated the sensi tivity, specificity, positive and negative predictive values (PPV and NPV), and likelihood ratios. Results. Forty-three patients had TCD and angiography: mean age was 57 ± 20 years, and 65% were men. Twenty-two patients were diagnosed with TICA stenosis or occlusion on TCD underwent angiography. Four patients had abnormal TCD findings that were not confirmed by angiography. Two of 21 patients with normal TCD showed mod erate (< 50%) stenosis of the TICA and cavernous segment of the internal carotid artery at angiography. Accuracy parameters for TCD were as follows: sensitivity = 90% (confidence interval [CI], 63%-96%), specificity = 83% (CI, 61%-94%), PPV = 82%, NPV = 86%, positive likelihood ratio = 5, and negative likelihood ratio = 0.17. Conclusions. TCD is a sensitive screening tool for the lesions in the TICA. Specificity is likely affected by a wide spectrum of the stenosis severity shown at angiography and time lags between the studies. [source] The effect of statin therapy on the progression of carotid artery stenosis in relation to stenosis severityACTA NEUROLOGICA SCANDINAVICA, Issue 1 2010O. Hegland Objectives,,, To examine the effect of early statin treatment on progression of arteriosclerosis in internal carotid arteries (ICA); to compare the progression of arteriosclerosis in ICA of patients treated with a statin to the progression seen in drug-naïve patients. Patients and methods,,, We performed repetitive Doppler scans of 363 carotid arteries with ICA stenosis ,40% in 254 patients over time. Information on statin therapy and other risk factors for stroke were correlated with the annual change in degree of ICA stenosis. Results,,, In statin-treated patients, 19% of ICA stenosis showed a progression while 74% showed a regression of stenosis. In statin - naïve patients, 63% of stenotic arteries showed a progression, while a reduction could be observed in 28%. Decrease of ICA stenosis was most accentuated in patients with a mild stenosis and was independent of serum cholesterol levels. Conclusion,,, Treatment with statins already in early stages of ICA stenosis might delay the progression and even reverse the degree of stenosis. [source] |