Home About us Contact | |||
Set Parameters (set + parameter)
Selected AbstractsA Neuro-Fuzzy Logic for ATIS Stand-Alone Control Systems: Structure, Calibration, and AnalysesCOMPUTER-AIDED CIVIL AND INFRASTRUCTURE ENGINEERING, Issue 3 2004Yaser E. Hawas The scheme logic attempts to optimize the network overall travel time by adjusting the path proportions while guessing the signal phase split decisions. An approximate simulation-based optimization algorithm is devised as an example of the logic operating this scheme. The logic is then replicated by a fuzzy-logic control system. Neural nets are utilized to develop the knowledge base of the fuzzy system and to calibrate the fuzzy set parameters. The neural nets utilize data replicates generated by the approximate simulation-based optimization algorithm. The calibration and effectiveness results of the fuzzy control system are presented. [source] Vertically fractured transversely isotropic media: dimensionality and deconstructionGEOPHYSICAL PROSPECTING, Issue 2 2009Michael A. Schoenberg ABSTRACT A vertically fractured transversely isotropic (VFTI) elastic medium is one in which any number of sets of vertical aligned fractures (each set has its normal lying in the horizontal x1, x2 -plane) pervade the medium and the sets of aligned fractures are the only features of the medium disturbing the axi-symmetry about the x3 -axis implying that in the absence of fractures, the background medium is transversely isotropic (TI). Under the assumptions of long wavelength equivalent medium theory, the compliance matrix of a fractured medium is the sum of the background medium's compliance matrix and a fracture compliance matrix. For sets of parallel rotationally symmetric fractures (on average), the fracture compliance matrix is dependent on 3 parameters , its normal and tangential compliance and its strike direction. When one fracture set is present, the medium is orthorhombic and the analysis is straightforward. When two (non-orthogonal) or more sets are present, the overall medium is in general elastically monoclinic; its compliance tensor components are subject to two equalities yielding an 11 parameter monoclinic medium. Constructing a monoclinic VFTI medium with n embedded vertical fracture sets, requires 5 TI parameters plus 3×n fracture set parameters. A deconstruction of such an 11 parameter monoclinic medium involves using its compliance tensor to find a background transversely isotropic medium and several sets of vertical fractures which, in the long wavelength limit, will behave exactly as the original 11 parameter monoclinic medium. A minimal deconstruction, would be to determine, from the 11 independent components, the transversely isotropic background (5 parameters) and two fracture sets (specified by 2 × 3 = 6 parameters). Two of the background TI medium's compliance matrix components are known immediately by inspection, leaving nine monoclinic components to be used in the minimal deconstruction of the VFTI medium. The use of the properties of a TI medium, which are linear relations on its compliance components, allows the deconstruction to be reduced to solving a pair of non-linear equations on the orientations of two fracture sets. A single root yielding a physically meaningful minimum deconstruction yields a unique minimal representation of the monoclinic medium as a VFTI medium. When no such root exists, deconstruction requires an additional fracture set and uniqueness is lost. The boundary between those monoclinic media that have a unique minimal representation and those that do not is yet to be determined. [source] Lethal photosensitization of periodontal pathogens by a red-filtered Xenon lamp in vitroJOURNAL OF PERIODONTAL RESEARCH, Issue 4 2003Donco Matevski Background:, The ability of Helium,Neon (He,Ne) laser irradiation of a photosensitizer to induce localized phototoxic effects that kill periodontal pathogens is well documented and is termed photodynamic therapy (PDT). Objectives:, We investigated the potential of a conventional light source (red-filtered Xenon lamp) to activate toluidine blue O (TBO) in vitro and determined in vitro model parameters that may be used in future in vivo trials. Materials and methods:,Porphyromonas gingivalis 381 was used as the primary test bacterium. Results:, Treatment with a 2.2 J/cm2 light dose and 50 µg/ml TBO concentration resulted in a bacterial kill of 2.43 ± 0.39 logs with the He,Ne laser control and 3.34 ± 0.24 logs with the lamp, a near 10-fold increase (p = 0.028). Increases in light intensity produced significantly higher killing (p = 0.012) that plateaued at 25 mW/cm2. There was a linear relationship between light dose and bacterial killing (r2 = 0.916); as light dose was increased bacterial survival decreased. No such relationship was found for the drug concentrations tested. Addition of serum or blood at 50% v/v to the P. gingivalis suspension prior to irradiation diminished killing from approximately 5 logs to 3 logs at 10 J/cm2. When serum was washed off, killing returned to 5 logs for all species tested except Bacteroides forsythus (3.92 ± 0.68 logs kill). Conclusions:, The data indicate that PDT utilizing a conventional light source is at least as effective as laser-induced treatment in vitro. Furthermore, PDT achieves significant bactericidal activity in the presence of serum and blood when used with the set parameters of 10 J/cm2, 100 mW/cm2 and 12.5 µg/ml TBO. [source] Neuropathological changes in vibration injury: An experimental studyMICROSURGERY, Issue 1 2005Hani S. Matloub M.D. Vibration syndrome, a clinical condition arising from chronic use of vibrating tools, is associated with a spectrum of neurovascular symptoms. To date, only its vascular pathology has been extensively studied; we sought to determine what direct neurologic injury, if any, is caused by vibration. Hindlimbs of anesthetized rats were affixed to a vibrating platform 4 h a day for 7 days. Study animals were vibrated with set parameters for frequency, acceleration, velocity, and amplitude; control animals were not vibrated. On day 7, nerves were studied by light and electron microscopy. While light microscopy showed minimal histologic differences between vibrated (n = 12) and control (n = 12) nerves, electron microscopic changes were dramatic. Splitting of the myelin sheath and axonal damage (e.g., myelin balls and "finger ring") were consistently seen in both myelinated and nonmyelinated axons. Despite relatively short vibration, definite pathology was demonstrated, suggesting that vibration syndrome has a direct neurologic component. © 2005 Wiley-Liss, Inc. Microsurgery 25:71,75, 2005. [source] |