Home About us Contact | |||
Autopsy Series (autopsy + series)
Selected AbstractsThree-dimensional sonographic volume measurement of the fetal spleenJOURNAL OF OBSTETRICS AND GYNAECOLOGY RESEARCH (ELECTRONIC), Issue 5 2007Toshiyuki Hata Abstract Aim:, The objective of this longitudinal study was to evaluate the growth of the fetal spleen in normal pregnancies, using three-dimensional ultrasound. Methods:, Three-dimensional sonographic examinations were performed on 14 appropriate-for-gestational-age fetuses. Fetal splenic volume was measured every 2,3 weeks after 20 weeks of gestational age until delivery. Results:, Curvilinear relationships were found between the gestational age and splenic volume (R2 = 80.2%, P < 0.0001), and normal ranges of splenic volume measurements for estimating the growth of the fetal spleen during normal pregnancy were generated. We found that the splenic volume calculation based on the equation for the volume of the ellipsoid by conventional two-dimensional ultrasound in previous investigations is about twice as large as that using three-dimensional ultrasound in our study, whereas the present data described in this study is quite comparable with previous data from an autopsy series. Conclusion:, Our findings suggest that the standard curve for the fetal splenic volume using three-dimensional ultrasound provides a superior means for evaluating the normal splenic growth in the fetus and for identifying splenic abnormalities in utero. However, the data and its interpretation in our study should be taken with some degree of caution because of the small number of subjects studied. Further studies involving a larger sample size would be needed to confirm these findings. [source] Neural tube defects and associated anomalies in a fetal and perinatal autopsy series,APMIS, Issue 4 2006LJUDMILLA A. G. NIELSEN Neural tube defects (NTDs) are congenital malformations of the central nervous system (CNS) secondary to abnormal closure of the neural tube during embryonic development. This study provides information on NTD rate, distribution, associated morphologic anomalies and organ weights in a Danish fetal and perinatal autopsy series during a 16 year period. The data were extracted from the autopsy reports of a consecutive series of 1984 fetal and perinatal autopsies from the Copenhagen area performed in the period 1989,2004. Registered parameters included: The location and morphology of the NTD, associated morphological anomalies, and organ weights. Organ weights were evaluated according to new fetal autopsy standards and grouped as low, normal or high. Ninety-seven NTD cases were found (4.9%): Spina bifida (38 cases), cephalocele (17 cases) and anencephaly (42 cases). 63% of NTD cases had associated morphologic anomalies. Among the most common were hydrocephalus, NTD in another region, and anomalies in the urogenital system. 58% of the NTD cases had abnormal weight of one or more organs. Most notable was low adrenal weight not only in anencephalic fetuses but also in cases with cephalocele, suggesting a possible association. [source] Experimental evaluation of the JenaClip transcatheter aortic valve,CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, Issue 3 2009Alexander Lauten Abstract Objective: Transcatheter techniques of aortic valve replacement are a treatment option for valvular heart disease in high-risk surgical candidates. We evaluated a self-expanding valve system with a novel mechanism of fixation in an experimental setting in an acute animal model and ex vivo in aortic root specimens. Method: A self-expanding nitinol stent containing a pericardial tissue valve was implanted in a transapical approach in 15 sheeps. The valve was introduced under fluoroscopic guidance through a 22F sheath by means of a specially designed delivery catheter. Deployment was performed on the beating heart without cardiopulmonary bypass or rapid ventricular pacing and facilitated by positioning feelers anchoring the device to the native aortic cusps. To investigate release and anchoring of the device during retrograde implantation, the stent was also implanted in aortic root specimens obtained from an autopsy series. Results: In animal experiments, stent deployment was primarily successful in 12 (80%) animals. Positioning feelers facilitated implantation by confirming the correct implantation plane of the stent and anchoring to the native aortic cusps. If primary location was not satisfactory the stent was retracted into the catheter and repositioned. After successful implantation no significant changes of hemodynamics were observed. Two animals (13%) developed ventricular fibrillation early in this experimental series due to displacement of one positioning element into a coronary ostium, major regurgitation was observed in two animals. Ex vivo evaluation of the device in aortic root specimens proved feasibility of stent release and leaflet fixation; ex vivo implantation was successful in all cases. Conclusion: .In this study, we demonstrate feasibility of a leaflet-fixation device in nondiseased aortic valves. The JenaClip provides an effective concept of fixation with positioning feelers that allows exact positioning without outflow obstruction and anchoring the valve to the native leaflets. Further studies are necessary to investigate this concept in diseased aortic valves. © 2009 Wiley-Liss, Inc. [source] |