Automated Hematology Analyzer (automate + hematology_analyzer)
Selected AbstractsPerformance evaluation of the PENTRA 60C+ automated hematology analyzer and comparison with the ADVIA 2120INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, Issue 2 2009K. GUERTI Summary The PENTRA 60C+ hematology analyzer provides a complete blood cell (CBC) count, including a five-part differential (5-DIFF) count and two leukocyte subpopulations, i.e. large immature cells (LIC's) and atypical lymphocytes (ALY's). We evaluated its analytical performance and assessed agreement with the ADVIA 2120, in order to install the analyzer in a small satellite hematology laboratory. First we assessed repeatability, reproducibility and carry-over to evaluate the analytical performance. Then we used Pearson correlation coefficients, Passing and Bablok regression analysis and a graphical approach (n = 209) to evaluate agreement with the ADVIA 2120. Repeatability and reproducibility were excellent for the majority of CBC and 5-DIFF count parameters. Carry-over was negligible. Our data showed very good correlation for most CBC count parameters. Lower correlation coefficients were observed for red cell distribution width, mean corpuscular volume and mean platelet volume. As compared to the ADVIA 2120, the 5-DIFF count performed very well. Agreement was poorer for low-level eosinophils and basophils. Furthermore, the PENTRA 60C+ was equally able to identify pathological blood samples through the determination of LIC's and ALY's. Therefore, the PENTRA 60C+ is an eligible blood cell counter to be operational in a satellite laboratory setting. [source] Venous stasis and routine hematologic testingINTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, Issue 5 2006G. LIPPI Summary Prolonged venous stasis, as generated by a long tourniquet placement, produces spurious variations in several measurable analytes. To verify to what extent venous stasis influences routine hematologic testing, we assessed routine hematologic parameters, including hemoglobin, hematocrit, red blood cell count (RBC), main cell hemoglobin (MHC), main cell volume (MCV), platelet count (PLT), main platelet volume (MPV), white blood cell count (WBC) and WBC differential on the Advia 120 automated hematology analyzer in 30 healthy volunteers, either without venous stasis (no stasis) or after application of a 60 mmHg standardized external pressure by a sphygmomanometer, for 1 (1-min stasis) and 3 min (3-min stasis). Although the overall correlation between measures was globally acceptable, the mean values for paired samples were significantly different in all parameters tested, except MCV, MHC, PLT, MPV, eosinophils, basophils and large unstained cells after 1-min stasis and all parameters except MCV, MHC, MPV and basophils after 3-min venous stasis. As expected RBC, hemoglobin and hematocrit displayed a significant trend towards increase, whereas WBC and the WBC subpopulations were decreased. Difference between measurements by Bland and Altman plots exceeded the current analytical quality specifications for desirable bias for WBC, RBC, hemoglobin, hematocrit, lymphocytes and monocytes in samples collected after either 1- and 3-min stasis. These results provide clear evidence that venous stasis during venipuncture might produce spurious and clinically meaningful biases in the measurement of several hematologic parameters, prompting further considerations on the usefulness of adopting appropriate preventive measures for minimizing such influences. [source] Quantification of red blood cell fragmentation by the automated hematology analyzer XE-2100 in patients with living donor liver transplantationINTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, Issue 5 2005S. BANNO Summary The fragmented red cell (FRC) is a useful index for diagnosing and determining the severity of thrombotic thrombocytopenic purpura (TTP), thrombotic microangiopathy (TMA) and other similar conditions, as it is found in peripheral blood in patients with these diseases. The FRC expression rate has conventionally been determined by manual methods using smear samples. However, it is difficult to attain accurate quantification by such methods as they are time consuming and prone to a great margin of error. With cases of living donor liver transplantation, the current study examined the possibility of using a multi-parameter automated hematology analyzer, the XE-2100 (Sysmex Corporation) for FRC quantification. While there was a notable correlation between the manual and automated measurements, the manual measurement resulted in higher values. This suggested remarkable variations in judgment by individuals. The FRC values had a significant correlation with the reticulocyte count, red blood cell distribution width (RDW), fibrin/fibrinogen degradation products (P-FDP) and lactate dehydrogenase (LDH) among the test parameters, and this finding was consistent with the clinical progression in patients. The automated method can offer precise measurements in a short time without inter-observer differences, meeting the requirement for standardization. The determination of FRC count (%) by the XE-2100 that enables early diagnoses and monitoring of TTP or TMA will be useful in the clinical field. [source] Automatic analysis of normal bone marrow blood cells using the XE-2100 automated hematology analyzerJOURNAL OF CLINICAL LABORATORY ANALYSIS, Issue 1 2003Hisako Shibata Abstract The bone marrow aspiration test conventionally has been performed by visual methods, using a light microscope, because automatic blood cell analyzers cannot adequately capture erythroblasts and immature granulocytes (IGs) (Tatsumi et al.: Osaka City Med J 1988;34:135,146; Tatsumi et al.: Am J Clin Pathol 1986;86:50,54). With the development of the XE-2100 automatic blood cell analyzer (Sysmex Corporation, Kobe, Japan) in 1999, the classification of erythroblasts and IGs by means of flow cytometry (Zini et al.: Infus Ther Transfus Med 2001;28:277,279; Briggs et al.: Sysmex J Int 1999;9:113,119) became possible. In the present study we classified cells in 65 bone marrow aspiration specimens by the microscopic method and with the XE2100, and compared the results. A good correlation was found in the nucleated red blood cell (NRBC), white blood cell (WBC), and total nucleated cell (TNC) counts; the myeloid/erythroid ratio (M/E ratio); neutrophils, lymphocytes, eosinophils, and IGs in the immature myeloid information (IMI) channel; and the total cell count. These items can all be analyzed in about 54 sec with the XE2100, which is faster than with the microscopic method. Therefore, analysis of bone marrow aspiration specimens with this apparatus appears to be very useful for clinical screening as well as laboratory testing. J. Clin. Lab. Anal. 17:12,17, 2003. © 2003 Wiley-Liss, Inc. [source] |