Home About us Contact | |||
Resection Patients (resection + patient)
Selected AbstractsImplant-Supported Obturator Overdenture for Extensive Maxillary Resection Patient: A Clinical ReportJOURNAL OF PROSTHODONTICS, Issue 3 2010Cláudio Rodrigues Leles DDS Abstract This clinical report presents an implant-retained obturator overdenture solution for a Prosthodontic Diagnostic Index Class IV maxillectomy patient with a large oronasal communication and severe facial asymmetry, loss of upper lip and midfacial support, severe impairment of mastication, deglutition, phonetics, and speech intelligibility. Due to insufficient bone support to provide satisfactory zygomaticus implant anchorage, conventional implants were placed in the body of the left zygomatic arch and in the right maxillary tuberosity. Using a modified impression technique, a cobalt-chromium alloy framework with three overdenture attachments was constructed to retain a complete maxillary obturator. Patient-reported functional and quality of life measure outcomes were dramatically improved after treatment and at the two-year follow-up. [source] Use of dissecting sealer may affect the early outcome in patients submitted to hepatic resectionHPB, Issue 4 2008I. DI CARLO Abstract Background. Many technological devices have been used to avoid intraoperative bleeding during hepatic parenchymal transection and to avoid morbidity and mortality, but until now none is complete. The aim of this work is to prospectively analyze hepatic resection patients treated with a water-cooled high frequency monopolar device in order to evaluate its effectiveness. Patients and methods. All consecutive patients who underwent liver resection by use of this device, between January 2003 until December 2007, were analyzed prospectively. The following variables were considered: age, sex, kind of disease, kind of liver resection, number of major/minor resections, total operative time and transection time, number and time of clamping, blood loss, time of hospitalization, morbidity, and mortality. Results. Between January 2003 and December 2007, 26 patients were analyzed prospectively (69% women, 31% men). Ages ranged from 18 to 84 years. Sixty-five percent of patients had a malignant disease; 35%, a benign disease. The procedures performed were two major hepatectomies (7.6%) and 24 minor hepatectomies (92.4%). Hepatic transection was performed in 35 to 150 min. Total operative time range was 120,480 min. The average blood loss was 325 ml (range 50,600 ml). The mean postoperative stays were nine days for all the patient and six days for non-cirrhotic patients. Conclusion. The water-cooled high frequency monopolar device is useful for reducing ischemia,reperfusion damage due to the Pringle maneuver and for reducing the risk of morbidity. However, the Kelly forceps remains the only inexpensive instrument really essential for liver surgery. [source] MOSHER AWARD HONORABLE MENTION,THE LARYNGOSCOPE, Issue 4 2000Natural History of Acoustic Neuromas Abstract Objectives/Hypothesis 1) Develop a computerized technique to accurately compare acoustic neuroma size on routine computed tomography and magnetic resonance imaging (MRI) scans; 2) use this technique to determine the growth pattern in a large series of patients with acoustic neuroma who were conservatively managed; 3) describe the natural history of patients with acoustic neuromas who did not receive surgical intervention and those who underwent subtotal resection; 4) correlate the size and growth rate of acoustic neuromas to clinical presentation and auditory and vestibular testing; and 5) recommend guidelines for the management of patients with acoustic neuromas. Study Design A retrospective study from 1974 to 1999 of patients with unilateral acoustic neuromas who had conservative treatment by serial imaging studies (80 patients) or subtotal resection (49 patients). Methods All patient charts were evaluated for presenting symptoms, reasons for the type of management given, and clinical outcome. Charts were also reviewed with respect to serial audiological assessment, electronystagmography, and brainstem auditory evoked response. Imaging studies were analyzed using a computer technique so that serial studies could be compared to determine growth rates. Results Rigorous computer analysis of tumor size and growth rate was statistically the same as the radiologist's description of the tumor size and growth rate. Of 70 patients who were older than 65 years of age old at the time their tumor was discovered, 4 (5.7%) required intervention and 18 (26%) were dead of unrelated causes. These patients had a mean follow-up of 4.8 years (range, 0.01,17.2 y). Overall, growth rate for nonsurgical patients was 0.91 mm per year. Nonsurgical tumors did not grow or regressed in 42.3%. Overall postoperative growth rate for surgical subtotal resection patients was 0.35 mm per year. Surgical tumors did not grow or regressed after subtotal resection of acoustic neuroma in 68.5% of patients. Three patients (6.1%) required revision surgery because of tumor growth or the development of symptoms. Neither auditory nor vestibular testing was a reliable measure for determining tumor growth. Conclusion Measurement of the maximal tumor diameter on MRI scans is a reliable method for following acoustic neuroma growth. There is no need to perform a rigorous analysis of tumor size to determine whether the tumor is growing significantly. The vast majority of patients older than 65 years with acoustic neuromas do not require intervention. The indications for intervention should be based on a combination of rapid tumor growth with the development of symptoms. [source] Pattern of carcinoembryonic antigen drop after laparoscopic radiofrequency ablation of liver metastasis from colorectal carcinomaCANCER, Issue 1 2006Mohammed Ghanamah M.D. Abstract BACKGROUND Laparoscopic radiofrequency ablation (RFA) is being increasingly used for local control of hepatic metastasis from colorectal carcinoma (CRC). After surgical resection of colorectal liver metastasis, carcinoembryonic antigen (CEA) values fall within 2 weeks, making this a useful parameter to follow shortly after surgery. Little is known, however, about the expected pattern of the CEA drop after RFA. METHODS From September 1998 to October 2002, RFA to CRC liver metastasis was performed on 144 patients. A subset of 17 patients were studied who had no evidence of extrahepatic disease preoperatively, had all detectable tumor ablated intraoperatively, and who on long-term follow-up (up to 15 months) had no evidence of recurrent disease. Serum CEA was determined preoperatively, on the first postoperative day, at 1 week, and every 3 months afterwards. A computed tomography (CT) scan of the abdomen and pelvis was obtained every 3 months postoperatively. RESULTS Ten (58.8%) patients showed an increase in CEA on postoperative Day 1, averaging 38.3% compared with the preoperative value. CEA then fell to 50% of the preoperative value, on average, on Day 7 postoperatively and only reached its nadir at 3 months. CONCLUSIONS Unlike resection patients, those undergoing ablation show an initial rise in CEA, probably due to release from the ablated tissue. Although heating of RFA would be expected to destroy CEA, the initial rise and slow drop postoperatively argue for a release of immunoreactive CEA from the ablated zone. This slow decline in CEA indicates that several months should pass before assessing the extent of potential residual disease. Cancer 2006. © 2006 American Cancer Society. [source] |