Home About us Contact | |||
Donor/recipient Pairs (recipient + pair)
Selected AbstractsVenous hemodynamics in living donor right lobe liver transplantationLIVER TRANSPLANTATION, Issue 9 2002Gabriel E. Gondolesi MD We evaluated the influence of portal and hepatic venous hemodynamics on the immediate and 3-month postoperative function of living donor right lobe grafts. Portal velocity was measured prospectively by ultrasound in 14 consecutive donor/recipient pairs. Velocity was converted to flow with the Moriyasu formula. Measurements were taken in donors in the operating room and in recipients at 1 hour after reperfusion and 3 months after transplant. Recipient liver function tests were measured postoperatively. Prereperfusion and postreperfusion liver biopsies were evaluated and correlated with the hemodynamic and biochemical results. There were 11 male (78.6%) and 3 female donors (mean age, 38.9 ± 9.8 years) for 10 male (71.4%) and 4 female recipients (mean age, 49.3 ± 14 years). The mean graft/recipient weight ratio was 1.22 ± 0.3. The mean right portal vein pressure was 8 ± 1.8 mm Hg in donors versus 13 ± 4.7 mm Hg in recipients (P < .05). The mean peak flow velocity (Vmax) in the portal vein in donors was 47.6 ± 12.8 cm/sec (normal, 44 cm/sec). One hour after graft reperfusion in the recipient, the mean portal Vmax was significantly higher at 94.7 ± 28.4 cm/sec (P = .004), but by 3 months follow-up, mean portal Vmax had fallen to 58.8 ± 37.8 (P = .01). Recipient portal vein Vmax highly correlated with portal flow (r = 0.7, P = .01). Increased recipient total bilirubin on postoperative day 2 correlated highly with higher recipient portal flow one hour after transplant (r = 0.6; P = .03). Portal vein velocity/flow dramatically increases after reperfusion, returning to baseline about 3 months after transplant. Evaluation of hepatic and portal venous flow is a relatively easy skill to acquire. Intraoperative ultrasound may enable the surgeon to predict graft dysfunction and possibly, may be used to implement pre-emptive therapies. [source] Perception Versus Reality?: Virtual Crossmatch,How to Overcome Some of the Technical and Logistic LimitationsAMERICAN JOURNAL OF TRANSPLANTATION, Issue 8 2009A. R. Tambur The goal of this work was to evaluate concordance between (a) actual flow cytometric crossmatch (FCXM) that is performed by the OPO laboratory servicing our transplant center and (b) virtual XM (vXM) prediction based on antibody identification by solid-phase methods performed in our laboratory. A total of 1586 FCXM, performed between June 2007 and September 2008, between all potential deceased donors in our region and sera from patients awaiting kidney or kidney,pancreas transplant, listed at Northwestern Memorial Hospital were evaluated. A key finding of this analysis was the understanding that a thorough vXM cannot be performed in some donor/recipient pairs due to the lack of certain antibody profile data specific to the donor in question. Obtaining more in depth and stringent information regarding antibody specificities, we demonstrate an excellent sensitivity and specificity of the vXM assays, 86.1% and 96.8%, respectively, with a positive likelihood ratio and negative likelihood ratios of 26.9 and 0.14, respectively. The vXM can serve as an outstanding tool to predict HLA compatibility between donor and recipient, with the caveat that the presence/absence of all antibodies against the potential donor and their strength have been thoroughly investigated. [source] Hand-Assisted Laparoscopic Living-Donor Nephrectomy as an Alternative to Traditional Laparoscopic Living-Donor NephrectomyAMERICAN JOURNAL OF TRANSPLANTATION, Issue 10 2002Joseph F. Buell The benefits of laparoscopic living-donor nephrectomy (LDN) are well described, while similar data on hand-assisted laparoscopic living-donor nephrectomy (HALDN) are lacking. We compare hand-assisted laparoscopic living-donor nephrectomy with open donor nephrectomy. One hundred consecutive hand-assisted laparoscopic living-donor nephrectomy (10/98,8/01) donor/recipient pairs were compared to 50 open donor nephrectomy pairs (8/97, 1/00). Mean donor weights were similar (179.6 ± 40.8 vs. 167.4 ± 30.3 lb; p =,NS), while donor age was greater among hand-assisted laparoscopic living-donor nephrectomy (38.2 ± 9.5 vs. 31.2 ± 7.8 year; p <,0.01). Right nephrectomies was fewer in hand-assisted laparoscopic living-donor nephrectomy [17/100 (17%) vs. 22/50 (44%); p <,0.05]. Operative time for hand-assisted laparoscopic living-donor nephrectomy (3.9 ± 0.7 vs. 2.9 ± 0.5 h; p <,0.01) was longer; however, return to diet (6.9 ± 2.8 vs. 25.6 ± 6.1 h; p <,0.01), narcotics requirement (17.9 ± 6.3 vs. 56.3 ± 6.4 h; p <,0.01) and length of stay (51.7 ± 22.2 vs. 129.6 ± 65.7 h; p <,0.01) were less than open donor nephrectomy. Costs were similar ($11 072 vs. 10 840). Graft function and 1-week Cr of 1.4 ± 0.9 vs. 1.6 ± 1.1 g/dL (p =,NS) were similar. With the introduction of HALDN, our laparoscopic living-donor nephrectomy program has increased by 20%. Thus, similar to traditional laparoscopic donor nephrectomy, hand-assisted laparoscopic living-donor nephrectomy provides advantages over open donor nephrectomy without increasing costs. [source] Capillary electrophoresis for chimerism monitoring by PCR amplification of microsatellite markers after allogeneic hematopoietic cell transplantationCLINICAL TRANSPLANTATION, Issue 3 2005Alexandros Spyridonidis Abstract:, Background:, Hematopoietic chimerism has been demonstrated to be relevant for donor cell engraftment and detection of minimal residual disease after allogeneic hematopoietic cell transplantation (aHCT). In the light of increasing numbers of non-myeloablative aHCT as a treatment modality sensitive, rapid, and accurate chimerism monitoring techniques acquire novel relevance. Methods:, We evaluated the informativeness of five microsatellite markers in 376 donor/recipient pairs and evaluated the ability of capillary electrophoresis to detect mixed chimerism after aHCT. The sensitivity for capillary electrophoresis with respect to different markers was determined by limiting dilution assays with mixed chimerism samples containing defined amounts of cells or DNA. Furthermore, capillary electrophoresis was applied in 17 retrospectively selected patients with a mixed chimerism detected previously by gel electrophoresis, having undergone aHCT for different hematologic diseases and initially achieving a complete donor chimerism. Results:, In 163 of 165 (98%) of all related and 210 of 211 (99%) unrelated transplants the microsatellites identified informative alleles. The sensitivity and accuracy was higher with capillary electrophoresis when compared with gel electrophoresis with three of five microsatellites. Potential pitfalls with the application of capillary electrophoresis was preferential amplification and the occurrence of stutter peaks in the representative area. Investigation of the selected patient samples demonstrated that detection of a mixed chimerism was earlier with capillary electrophoresis when compared with gel electrophoresis. The detected recipient genotype by capillary electrophoresis examination, despite a negative gel electrophoresis result, ranged from 0.7 to 7.1%. Conclusions:, We conclude that chimerism assessment with our five microsatellites identified informative alleles in 99% of all donor/recipient pairs and may therefore be of use when establishing an institutional chimerism testing procedure. Capillary electrophoresis displayed a high sensitivity and accuracy for detecting a mixed chimerism in vitro and in vivo. [source] The Detrimental Effect of Poor Early Graft Function After Laparoscopic Live Donor Nephrectomy on Graft OutcomesAMERICAN JOURNAL OF TRANSPLANTATION, Issue 2 2009J. M. Nogueira We undertook this study to assess the rate of poor early graft function (EGF) after laparoscopic live donor nephrectomy (lapNx) and to determine whether poor EGF is associated with diminished long-term graft survival. The study population consisted of 946 consecutive lapNx donors/recipient pairs at our center. Poor EGF was defined as receiving hemodialysis on postoperative day (POD) 1 through POD 7 (delayed graft function [DGF]) or serum creatinine , 3.0 mg/dL at POD 5 without need for hemodialysis (slow graft function [SGF]). The incidence of poor EGF was 16.3% (DGF 5.8%, SGF 10.5%), and it was stable in chronologic tertiles. Poor EGF was independently associated with worse death-censored graft survival (adjusted hazard ratio (HR) 2.15, 95% confidence interval (CI) 1.34,3.47, p = 0.001), worse overall graft survival (HR 1.62, 95% CI 1.10,2.37, p = 0.014), worse acute rejection-free survival (HR 2.75, 95% CI 1.92,3.94, p < 0.001) and worse 1-year renal function (p = 0.002). Even SGF independently predicted worse renal allograft survival (HR 2.54, 95% CI 1.44,4.44, p = 0.001). Risk factors for poor DGF included advanced donor age, high recipient BMI, sirolimus use and prolonged warm ischemia time. In conclusion, poor EGF following lapNx has a deleterious effect on long-term graft function and survival. [source] Association of IL-6 gene polymorphism with the outcome of allogeneic haematopoietic stem cell transplantation in Czech patientsINTERNATIONAL JOURNAL OF IMMUNOGENETICS, Issue 4-5 2008Z. Ambruzova Summary Interleukin-6 (IL-6) is an important pro-inflammatory mediator implicated in immune-mediated complications of allogeneic haematopoietic stem cell transplantation (aHSCT). In accord with previous reports, this preliminary study on 56 donor,recipient pairs revealed IL-6-174 single nucleotide polymorphisms as a risk factor for the development of acute graft-versus-host disease and decreased survival after aHSCT. [source] Does middle hepatic vein omission in a right split graft affect the outcome of liver transplantation?LIVER TRANSPLANTATION, Issue 6 2007A comparative study of right split livers with, without the middle hepatic vein Preservation of the middle hepatic vein (MHV) for a right split liver transplantation (SLT) in an adult recipient is still controversial. The aim of this study was to evaluate the graft and patient outcomes after liver transplantation (LT) using a right split graft, according to the type of venous drainage. From February 2000 to May 2006, 33 patients received 34 cadaveric right split liver grafts. According to the type of recipient pairs (adult/adult or adult/child), the right liver graft was deprived of the MHV or not. The first group (GI, n = 15) included grafts with only the right hepatic vein (RHV) outflow, the second (GII, n = 18) included grafts with both right and MHV outflows. The 2 groups were similar for patient demographics, initial liver disease, and donor characteristics. In GI and GII, graft-to-recipient-weight ratio (GRWR) was 1.2 ± 0% and 1.6 ± 0.3% (P < 0.05), and cold ischemia time was 10 hours 55 minutes ± 2 hours 49 minutes and 10 hours 47 minutes ± 3 hours 32 minutes, respectively (P = not significant). Postoperative death occurred in 1 patient in each group. Vascular complications included anastomotic strictures: 2 portal vein (PV), 1 hepatic artery (HA), and 1 RHV anastomotic strictures; all in GI. Biliary complications occurred in 20% and 22% of the patients, in GI and GII, respectively (P = not significant). There were no differences between both groups regarding postoperative outcome and blood tests at day 1-15 except for a significantly higher cholestasis in GI. At 1 and 3 yr, patient survival was 94% for both groups and graft survival was 93% for GI and 90% for GII (P = not significant). In conclusion, our results suggest that adult right SLT without the MHV is safe and associated with similar long-term results as compared with those of the right graft including the MHV, despite that early liver function recovered more slowly. Technical refinements in outflow drainage should be evaluated in selected cases. Liver Transpl 13:829,837, 2007. © 2007 AASLD. [source] Clinical Outcomes of Multicenter Domino Kidney Paired DonationAMERICAN JOURNAL OF TRANSPLANTATION, Issue 10 2009Y. J. Lee Domino kidney paired donation (KPD) is a method by which an altruistic living nondirected donor (LND) is allocated to a pool of incompatible donor,recipient pairs (DRP) and a series of KPDs is initiated. To evaluate the feasibility and clinical outcomes of multicenter domino KPD, we retrospectively analyzed a cohort of DRPs who underwent domino KPD between February 2001 and July 2007 at one of 16 transplant centers. One hundred seventy-nine kidney transplants were performed, with 70 domino chains initiated by altruistic LND. There were 45 two-pair chains, 15 three-pair chains, 7 four-pair chains, 2 five-pair chains and 1 six-pair chain. A majority of donors were spouses (47.5%) or altruistic LNDs (39.1%). DRPs with a blood type O recipient or an AB donor comprised 45.9% of transplanted DRPs. HLA mismatch improved in transplanted donors compared to intended donors in pairs enrolled to improve HLA mismatch (3.4 ± 0.7 vs. 4.8 ± 1.0, p < 0.001). One-year and 5-year graft survival rates were 98.3% and 87.7%, respectively, with a median follow-up of 46 months. One-year and 5-year patient survival rates were 97.2% and 90.8%, respectively. In conclusion, multicenter domino KPD could multiply the benefits of donation from LNDs, with patients and graft survival rates comparable to those seen with conventional KPD. [source] Split-Liver Transplantation: A ReviewAMERICAN JOURNAL OF TRANSPLANTATION, Issue 11 2003John F. Renz Split-liver transplantation (SLT), a procedure where one cadaver liver is divided to provide for two recipients, offers immediate expansion of the existing cadaver donor pool. To date, the principal beneficiaries of SLT have been adult/pediatric recipient pairs with excellent outcomes reported; however, the current scarcity of cadaver organs has renewed interest in expanding these techniques to include two adult recipients from one adult cadaver donor. Significant obstacles to the widespread application of SLT exist and must be resolved by the transplant community before greater utilization can be realized. This manuscript reviews the historic background, surgical techniques, current results, and obstacles impeding further application of SLT. [source] |