Home About us Contact | |||
Reaction Monitoring (reaction + monitoring)
Kinds of Reaction Monitoring Terms modified by Reaction Monitoring Selected AbstractsScreening for the calstabin-ryanodine receptor complex stabilizers JTV-519 and S-107 in doping control analysisDRUG TESTING AND ANALYSIS, Issue 1 2009Mario Thevis Abstract Recent studies outlined the influence of exercise on the stability of the skeletal muscle calstabin1-ryanodine receptor1-complex, which represents a major Ca2+ release channel. The progressive modification of the type-1 skeletal muscle ryanodine receptor (RyR1) combined with reduced levels of calstabin1 and phosphodiesterase PDE4D3 resulted in a Ca2+ leak that has been a suggested cause of muscle damage and impaired exercise capacity. The use of 1,4-benzothiazepine derivatives such as the drug candidates JTV-519 and S-107 enhanced rebinding of calstabin1 to RyR1 and resulted in significantly improved skeletal muscle function and exercise performance in rodents. Due to the fact that the mechanism of RyR1 remodelling under exercise conditions were proven to be similar in mice and humans, a comparable effect of JTV-519 and S-107 on trained athletes is expected, making the compounds relevant for doping controls. After synthesis of JTV-519, S-107, and a putative desmethylated metabolite of S-107, target compounds were characterized using nuclear magnetic resonance spectroscopy and electrospray ionization (ESI),high-resolution/high-accuracy Orbitrap mass spectrometry. Collision-induced dissociation pathways were suggested based on the determination of elemental compositions of product ions and H/D-exchange experiments. The most diagnostic product ion of JTV-519 was found at m/z 188 (representing the 4-benzyl-1-methyl piperidine residue), and S-107 as well as its desmethylated analog yielded characteristic fragments at m/z 153 and 138 (accounting for 1-methoxy-4-methylsulfanyl-benzene and 4-methoxy-benzenethiol residues, respectively). The analytes were implemented in existing doping control screening procedures based on liquid chromatography, multiple reaction monitoring and simultaneous precursor ion scanning modes using a triple quadrupole mass spectrometer. Validation items such as specificity, recovery (68,92%), lower limit of detection (0.1,0.2 ng/mL), intraday (5.2,18.5%) and interday (8.7,18.8%) precision as well as ion suppression/enhancement effects were determined. Copyright © 2009 John Wiley & Sons, Ltd. [source] Analyses of gibberellins in coconut (Cocos nucifera L.) water by partial filling-micellar electrokinetic chromatography-mass spectrometry with reversal of electroosmotic flowELECTROPHORESIS, Issue 10 2008Liya Ge Abstract In this paper, we present the results of simultaneous screening of eight gibberellins (GAs) in coconut (Cocos nucifera L.) water by MEKC directly coupled to ESI-MS detection. During the development of MEKC-MS, partial filling (PF) was used to prevent the micelles from reaching the mass spectrometer as this is detrimental to the MS signal, and a cationic surfactant, cetyltrimethylammonium hydroxide, was added to the electrolyte to reverse the EOF. On the basis of the resolution of the neighboring peaks, different parameters (i.e., the pH and concentration of buffer, surfactant concentrations, length of the injected micellar plug, organic modifier, and applied separation voltage) were optimized to achieve a satisfactory PF-MEKC separation of eight GA standards. Under optimum conditions, a baseline separation of GA standards, including GA1, GA3, GA5, GA6, GA7, GA9, GA12, and GA13, was accomplished within 25,min. Satisfactory results were obtained in terms of precision (RSD of migration time below 0.9%), sensitivity (LODs in the range of 0.8,1.9,,M) and linearity (R2 between 0.981 and 0.997). MS/MS with multiple reaction monitoring (MRM) detection was carried out to obtain sufficient selectivity. PF-MEKC-MS/MS allowed the direct identification and confirmation of the GAs presented in coconut water (CW) sample after SPE, while, the quantitative analysis of GAs was performed by PF-MEKC-MS approach. GA1 and GA3 were successfully detected and quantified in CW. It is anticipated that the current PF-MEKC-MS method can be applicable to analyze GAs in a wide range of biological samples. [source] Identification of androstenedione in a river containing paper mill effluent,ENVIRONMENTAL TOXICOLOGY & CHEMISTRY, Issue 6 2001Ronald Jenkins Abstract Effluent from a paper mill discharging into the Fenholloway River, Taylor County, Florida, USA, contains chemicals that masculinize females of the resident population of eastern mosquitofish (Gambusia holbrooki), as evidenced in females by elongated anal fins, which is normally a male-specific trait. To identify androgenic components in the effluent, water collected from the Fenholloway River and a control tributary was fractionated using solid-phase extraction and reverse-phase high-performanceliquid chromatography. Two Fenholloway River fractions induced androgen receptor-dependent transcriptional activity in transient transfection cell culture assays. Of these, androstenedione was confirmed by liquid chromatography-mass spectrometry with multiple reaction monitoring. [source] Homologous desensitization of guanylyl cyclase A, the receptor for atrial natriuretic peptide, is associated with a complex phosphorylation patternFEBS JOURNAL, Issue 11 2010Juliane Schröter Atrial natriuretic peptide (ANP), via its guanylyl cyclase A (GC-A) receptor and intracellular guanosine 3,,5,-cyclic monophosphate production, is critically involved in the regulation of blood pressure. In patients with chronic heart failure, the plasma levels of ANP are increased, but the cardiovascular actions are severely blunted, indicating a receptor or postreceptor defect. Studies on metabolically labelled GC-A-overexpressing cells have indicated that GC-A is extensively phosphorylated, and that ANP-induced homologous desensitization of GC-A correlates with receptor dephosphorylation, a mechanism which might contribute to a loss of function in vivo. In this study, tandem MS analysis of the GC-A receptor, expressed in the human embryonic kidney cell line HEK293, revealed unambiguously that the intracellular domain of the receptor is phosphorylated at multiple residues: Ser487, Ser497, Thr500, Ser502, Ser506, Ser510 and Thr513. MS quantification based on multiple reaction monitoring demonstrated that ANP-provoked desensitization was accompanied by a complex pattern of receptor phosphorylation and dephosphorylation. The population of completely phosphorylated GC-A was diminished. However, intriguingly, the phosphorylation of GC-A at Ser487 was selectively enhanced after exposure to ANP. The functional relevance of this observation was analysed by site-directed mutagenesis. The substitution of Ser487 by glutamate (which mimics phosphorylation) blunted the activation of the GC-A receptor by ANP, but prevented further desensitization. Our data corroborate previous studies suggesting that the responsiveness of GC-A to ANP is regulated by phosphorylation. However, in addition to the dephosphorylation of the previously postulated sites (Ser497, Thr500, Ser502, Ser506, Ser510), homologous desensitization seems to involve the phosphorylation of GC-A at Ser487, a newly identified site of phosphorylation. The identification and further characterization of the specific mechanisms involved in the downregulation of GC-A responsiveness to ANP may have important pathophysiological implications. Structured digital abstract ,,MINT-7713870, MINT-7713887: PMCA (uniprotkb:P20020) and GC-A (uniprotkb:P18910) colocalize (MI:0403) by fluorescence microscopy (MI:0416) [source] Evaluating outpatient pharmacy services: a literature review of specialist heart failure servicesINTERNATIONAL JOURNAL OF PHARMACY PRACTICE, Issue 1 2006Tracey-Lea Hargraves Pharmacist (formerly) Objective To identify appropriate methods to evaluate a specialist pharmacy service for heart failure patients in an ambulatory care setting. Method An extensive literature review was undertaken to identify the published data on evaluative studies of specialist pharmacy services, including those directed at heart failure patients in an ambulatory care model of service provision. Key findings Six studies were identified evaluating outpatient pharmacy services for heart failure. The pharmacy services provided in these settings were not well defined. The impact of the pharmacist was compared to ,usual care', that is care delivered without a pharmacist, by either a prospective randomised controlled trial (RCT), or before and after studies. In most cases the service was delivered by one pharmacist at one site. Services were primarily targeted at patients and focused on medication and lifestyle education, adverse drug reaction monitoring, and compliance/adherence. In all studies, there was a trend for improvement in the outcomes measured. Different study endpoints were examined, including process indicators such as compliance and outcome measures such as morbidity (clinical), quality of life (humanistic), and hospital admissions (economic). The ideal evaluative study would be an adequately powered, prospective, randomised controlled trial, comparing the effect of the pharmacist service to usual care (without the specified pharmacy service). Appropriate study endpoints including process indicators and outcome measures are needed. Identification of specific components and the extent of the service that would provide the most benefit to selected patient groups would be of interest. Conclusions Specialist ambulatory care pharmacy services have not been well defined or evaluated in the literature. Limited randomised controlled data exist. [source] Dichlorvos, chlorpyrifos oxon and Aldicarb adducts of butyrylcholinesterase, detected by mass spectrometry in human plasma following deliberate overdoseJOURNAL OF APPLIED TOXICOLOGY, Issue 6 2010Bin Li Abstract The goal of this study was to develop a method to detect pesticide adducts in tryptic digests of butyrylcholinesterase in human plasma from patients poisoned by pesticides. Adducts to butyrylcholinesterase in human serum may serve as biomarkers of pesticide exposure because organophosphorus and carbamate pesticides make a covalent bond with the active site serine of butyrylcholinesterase. Serum samples from five attempted suicides (with dichlorvos, Aldicarb, Baygon and an unknown pesticide) and from one patient who accidentally inhaled dichlorvos were analyzed. Butyrylcholinesterase was purified from 2 ml serum by ion exchange chromatography at pH 4, followed by procainamide affinity chromatography at pH 7. The purified butyrylcholinesterase was denatured, digested with trypsin and the modified peptide isolated by HPLC. The purified peptide was analyzed by multiple reaction monitoring in a QTRAP 4000 mass spectrometer. This method successfully identified the pesticide-adducted butyrylcholinesterase peptide in four patients whose butyrylcholinesterase was inhibited 60,84%, but not in two patients whose inhibition levels were 8 and 22%. It is expected that low inhibition levels will require analysis of larger serum plasma volumes. In conclusion, a mass spectrometry method for identification of exposure to live toxic pesticides has been developed, based on identification of pesticide adducts on the active site serine of human butyrylcholinesterase. Copyright © 2010 John Wiley & Sons, Ltd. [source] High-performance liquid chromatography coupled with electrospray ionization tandem mass spectrometry for the determination of flocoumafen and brodifacoum in whole bloodJOURNAL OF APPLIED TOXICOLOGY, Issue 1 2007Mi-cong Jin Abstract A high-performance liquid chromatographic,tandem mass spectrometric (HPLC,MS,MS) assay was developed and validated to determine quantitatively flocoumafen and brodifacoum in whole blood using warfarin as an internal standard (IS). Liquid,liquid extraction, using ethyl acetate, was used to isolate flocoumafen, brodifacoum and the IS from the biological matrix. Detection was performed on a mass spectrometer by negative electrospray ionization (ESI) in multiple reaction monitoring (MRM) mode. The calibration curves were linear (r2 > 0.998) in the concentration range of 0.1,100.0 ng ml,1 with a lower limit of quantification of 0.05 ng ml,1 for flocoumafen, and 0.1 ng ml,1 for brodifacoum in whole blood. Intra-day and inter-day relative standard deviations (RSDs) were less than 8.0% and 10.8%, respectively. Recoveries of flocoumafen and brodifacoum ranged from 78.0% to 83.7%. This assay can be used to determine trace flocoumafen and brodifacoum in whole blood to investigate suspected poisoning of human and animals. Copyright © 2006 John Wiley & Sons, Ltd. [source] Interactive curve resolution by using latent projections in polar coordinatesJOURNAL OF CHEMOMETRICS, Issue 1-2 2007J. von Frese Abstract The problem of resolving bilinear two-way data into the contributions from the underlying mixture components is of great interest for all hyphenated analytical techniques. The fact that the optimal solution to this problem at least to some extent depends on the nature of the data under study has lead to a numerous different approaches. One of the seminal publications in this area was contributed by Olav M. Kvalheim and Yi-Zeng Liang in 1992. They not only provided valuable Heuristic Evolving Latent Projections (HELP) but also enlightened many important aspects of curve resolution in this and numerous subsequent publications. Here we extend their key concept of HELP, that is the use of latent projective graphs for identifying one-component regions, by using polar coordinates for these analyses and thereby creating a simple, intuitive exploratory tool for directly solving the curve resolution problem for two and three components graphically. Our approach is demonstrated with simulated data, an example from reaction monitoring with broadband ultrafast spectroscopy and one chemometric standard data set. Copyright © 2007 John Wiley & Sons, Ltd. [source] High-sensitivity analysis of specific peptides in complex samples by selected MS/MS ion monitoring and linear ion trap mass spectrometry: Application to biological studiesJOURNAL OF MASS SPECTROMETRY (INCORP BIOLOGICAL MASS SPECTROMETRY), Issue 11 2007Inmaculada Jorge Abstract Mass spectrometry (MS) is a technique of paramount importance in Proteomics, and developments in this field have been possible owing to novel MS instrumentation, experimental strategies, and bioinformatics tools. Today it is possible to identify and determine relative expression levels of thousands of proteins in a biological system by MS analysis of peptides produced by proteolytic digestion. In some situations, however, the precise characterization of a particular peptide species in a very complex peptide mixture is needed. While single-fragment ion-based scanning modes such as selected ion reaction monitoring (SIRM) or consecutive reaction monitoring (CRM) may be highly sensitive, they do not produce MS/MS information and their actual specificity must be determined in advance, a prerequisite that is not usually met in a basic research context. In such cases, the MS detector may be programmed to perform continuous MS/MS spectra on the peptide ion of interest in order to obtain structural information. This selected MS/MS ion monitoring (SMIM) mode has a number of advantages that are fully exploited by MS detectors that, like the linear ion trap, are characterized by high scanning speeds. In this work, we show some applications of this technique in the context of biological studies. These results were obtained by selecting an appropriate combination of scans according to the purpose of each one of these research scenarios. They include highly specific identification of proteins present in low amounts, characterization and relative quantification of post-translational modifications such as phosphorylation and S -nitrosylation and species-specific peptide identification. Copyright © 2007 John Wiley & Sons, Ltd. [source] A rapid and sensitive liquid chromatography/positive ion tandem mass spectrometry method for the determination of cimetropium in human plasma by liquid,liquid extractionJOURNAL OF MASS SPECTROMETRY (INCORP BIOLOGICAL MASS SPECTROMETRY), Issue 7 2006Heon-Woo Lee Abstract We have developed and validated a simple detection system with high-performance liquid chromatography (HPLC) with positive ion electrospray ionization tandem mass spectrometry (ESI-MS/MS) for determining cimetropium levels in human plasma using scopolamine butyl bromide as an internal standard (I.S.). The acquisition was performed in the multiple reaction monitoring (MRM) mode, by monitoring the transitions: m/z 357.9 > 103.1 for cimetropium and m/z 359.9 > 103.1 for butyl-scopolamine. The method involves a simple single-step liquid,liquid extraction with dichloromethane. The analyte was chromatographed on an YMC C18 reversed-phase chromatographic column by isocratic elution with 10 mM ammonium formate buffer,methanol (19 : 81, v/v; adjusted to pH 4.0 with formic acid). The results were linear over the studied range (0.2,100 ng ml,1), with r2 = 1.0000, and the total analysis time for each run was 2 min. Intra- and interassay precisions were 0.70,8.54% and 1.08,4.85%, respectively, and intra- and interassay accuracies were 97.56,108.23% and 97.48,103.91%, respectively. The lower limit of quantification (LLOQ) was 0.2 ng ml,1. At this concentration, mean intra- and interassay precisions were 8.54% and 4.85%, respectively, and mean intra- and interassay accuracies were 97.56% and 98.91%, respectively. The mean recovery ranged from 62.71 ± 4.06 to 64.23 ± 2.32%. Cimetropium was found to be stable in plasma samples under typical storage and processing conditions. The devised assay was successfully applied to a pharmacokinetic study of cimetropium bromide administered as a single oral dose (150 mg) to healthy volunteers. Copyright © 2006 John Wiley & Sons, Ltd. [source] Structure elucidation and reaction monitoring of synthetic intermediates using an automated accurate mass GC-TOF mass spectrometer in drug discoveryJOURNAL OF MASS SPECTROMETRY (INCORP BIOLOGICAL MASS SPECTROMETRY), Issue 10 2005Chris Petucci [source] Thin-layer chromatography/electrospray ionization triple-quadrupole linear ion trap mass spectrometry system: analysis of rhodamine dyes separated on reversed-phase C8 plates ,JOURNAL OF MASS SPECTROMETRY (INCORP BIOLOGICAL MASS SPECTROMETRY), Issue 7 2005Michael J. Ford Abstract The direct analysis of separated rhodamine dyes on reversed-phase C8 thin-layer chromatography plates using a surface sampling/electrospray emitter probe coupled with a triple-quadrupole linear ion trap mass spectrometer is presented. This report represents continuing work to advance the performance metrics and utility of this basic surface sampling electrospray mass spectrometry system for the analysis of thin-layer chromatography plates. Experimental results examining the role of sampling probe spray end configuration on liquid aspiration rate and gas-phase ion signal generated are discussed. The detection figures-of-merit afforded by full-scan, automated product ion and selected reaction monitoring modes of operation were examined. The effect of different eluting solvents on mass spectrum signal levels with the reversed-phase C8 plate was investigated. The combined effect of eluting solvent flow-rate and development lane surface scan rate on preservation of chromatographic resolution was also studied. Analysis of chromatographically separated red pen ink extracts from eight different pens using selected reaction monitoring demonstrated the potential of this surface sampling electrospray mass spectrometry system for targeted compound analysis with real samples. Copyright © 2005 John Wiley & Sons, Ltd. [source] Simultaneous quantification of cyclophosphamide, 4-hydroxycyclophosphamide, N,N,,N, -triethylenethiophosphoramide (thiotepa) and N,N,,N, -triethylenephosphoramide (tepa) in human plasma by high-performance liquid chromatography coupled with electrospray ionization tandem mass spectrometryJOURNAL OF MASS SPECTROMETRY (INCORP BIOLOGICAL MASS SPECTROMETRY), Issue 3 2004Milly E. de Jonge Abstract The alkylating agents cyclophosphamide (CP) and N, N,, N, -triethylenethiophosphoramide (thiotepa) are often co-administered in high-dose chemotherapy regimens. Since these regimens can be complicated by the occurrence of severe and sometimes life-threatening toxicities, pharmacokinetically guided administration of these compounds, to reduce variability in exposure, may lead to improved tolerability. For rapid dose adaptations during a chemotherapy course, we have developed and validated an assay, using liquid chromatography coupled with electrospray tandem mass spectrometry (LC/MS/MS), for the routine quantification of CP, thiotepa and their respective active metabolites 4-hydroxycyclophosphamide (4OHCP) and N, N,, N, -triethylenephosphoramide (tepa) in plasma. Because of the instability of 4OHCP in plasma, the compound is derivatized with semicarbazide (SCZ) immediately after sample collection and quantified as 4OHCP-SCZ. Sample pretreatment consisted of protein precipitation with a mixture of methanol and acetronitrile using 100 µl of plasma. Chromatographic separation was performed on an Zorbax Extend C18 column (150 × 2.1 mm i.d., particle size 5 µm), with a quick gradient using 1 mM ammonia solution and acetonitrile, at a flow-rate of 0.4 ml min,1. The analytical run time was 10 min. The triple quadrupole mass spectrometer was operating in the positive ion mode and multiple reaction monitoring was used for drug quantification. The method was validated over the concentration ranges 200,40 000 ng ml,1 for CP, 50,5000 ng ml,1 for 4OHCP-SCZ and 5,2500 ng ml,1 for thiotepa and tepa, using 100 µl of human plasma. These dynamic concentration ranges proved to be relevant in daily practice. Hexamethylphosphoramide was used as an internal standard. The coefficients of variation were <12% for both intra-day and inter-day precisions for each compound. Mean accuracies were also between the designated limits (±15%). This robust and rapid LC/MS/MS assay is now successfully applied for routine therapeutic drug monitoring of CP, thiotepa and their metabolites in our hospital. Copyright © 2004 John Wiley & Sons, Ltd. [source] Qualitative study of in vivo melphalan adduct formation in the rat by miniaturized column-switching liquid chromatography coupled with electrospray mass spectrometryJOURNAL OF MASS SPECTROMETRY (INCORP BIOLOGICAL MASS SPECTROMETRY), Issue 1 2004Bart Van den Driessche Abstract In a general study of DNA adduct formation with melphalan, rats were intravenously injected with a single high dose (10 mg kg,1). Adduct formation was studied at the nucleoside level in the target organs liver, bone marrow, kidney and blood with the use of 2D liquid chromatography/tandem mass spectrometry (LC/MS/MS). Adducts of dGuo and dAdo were detected under selected reaction monitoring in liver and bone marrow 10 h after administration of melphalan. In the DNA hydrolysates from kidney and blood a Gua,melphalan adduct was found, although in very low abundance. These first results of the search for in vivo -formed melphalan adducts in the rat showed that our miniaturized LC/MS technique is useful for investigating this type of compound. More experiments will be performed in this area to gather more information about the pharmacokinetics and the quantity of adducts formed. Copyright © 2003 John Wiley & Sons, Ltd. [source] Determination of aminoglycoside and macrolide antibiotics in meat by pressurized liquid extraction and LC-ESI-MSJOURNAL OF SEPARATION SCIENCE, JSS, Issue 4-5 2010Houda Berrada Abstract A simple method for the simultaneous determination of dihydrostreptomycin, spectinomycin, spiramycin, streptomycin, tilmicosin, and tylosin in meat has been developed using pressurized liquid extraction and LC-triple quadrupole MS (LC-ESI-MS/MS). The pressurized liquid extraction operational parameters were optimized and no protein precipitating and fat removing steps were required. A gradient HPLC separation was developed with ion-pair mobile phases consisting of aqueous 1,mM heptafluorobutyric acid water and methanol. Protonated molecules were used as precursor ions for CID. Data acquisition under MS/MS was achieved by applying multiple reaction monitoring of three fragment ion transitions to provide a high degree of sensitivity and specificity. Dirithromycin and sisomycin were selected as internal standards. A validation study was conducted for these antibiotics in poultry meat samples. All selected compounds could be detected (monitoring ions by multiple reaction monitoring) in meat samples at amounts below the regulatory level of concern. Using the internal standards, pressurized liquid extraction recovery rates were from 70 to 96% (RSD 12,25%). LC-ESI-MS/MS method detection limits of the selected antibiotics were 1,6,,g/kg. Good method reproducibility was found by intra- and inter-day precisions at maximum residue level, yielding the RSDs less than 15 and 16%, respectively. [source] Determination of avoparcin in animal tissues and milk using LC-ESI-MS/MS and tandem-SPEJOURNAL OF SEPARATION SCIENCE, JSS, Issue 22 2008Koichi Inoue Abstract A highly sensitive and selective method using LC-ESI-MS/MS and tandem-SPE was developed to detect trace amounts of avoparcin (AV) antibiotics in animal tissues and milk. Data acquisition using MS/MS was achieved by applying multiple reaction monitoring of the product ions of [M + 3H]3+ and the major product ions of AV-, and -, at m/z 637 , 86/113/130 and m/z 649 , 86/113/130 in ESI(+) mode. The calculated instrumental LODs were 3 ng/mL. The sample preparation was described that the extraction using 5% TFA and the tandem-SPE with an ion-exchange (SAX) and InertSep C18-A cartridge clean-up enable us to determine AV in samples. Ion suppression was decreased by concentration rates of each sample solution. These SPE concentration levels could be used to detect quantities of 5 ppb (milk), 10 ppb (beef), and 25 ppb (chicken muscle and liver). The matrix matching calibration graphs obtained for both AV-, (r >0.996) and -, (r >0.998) from animal tissues and milk were linear over the calibration ranges. AV recovery from samples was higher than 73.3% and the RSD was less than 12.0% (n = 5). [source] HPLC-MS of anthraquinoids, flavonoids, and their degradation products in analysis of natural dyes in archeological objectsJOURNAL OF SEPARATION SCIENCE, JSS, Issue 13 2007Izabella Surowiec Abstract LC with MS detection was optimized for sensitive and selective analysis of main classes of natural dyes used in ancient times for dyeing textiles , red anthraquinoids, yellow flavonoids, and known degradation products of flavonols , hydroxybenzoic acids. Fragmentation patterns of both negative and positive molecular ions for the above mentioned compounds were investigated. Three acquisition modes of MS analysis: scanning, SIM, and multiple reaction monitoring (MRM) in both positive and negative ion modes were optimized and compared with each other and with the UV-Vis diode-array detection. Even though in the applied chromatographic system formic acid was used in the mobile phase, SIM in the negative ion mode was the most selective and sensitive detection for all the investigated compounds when both mixtures of standards and analysis of extracts from archeological samples were concerned, with one exception , alizarin, for which MS detection in positive ion mode was more sensitive. Detection limits obtained with MS detection for all investigated compounds except quinizarin were lower than the ones obtained with the diode-array UV-Vis detection, making MS detection the most suitable tool for the analysis of natural dyes and their degradation products in extracts from archeological samples. [source] The secreted and surface proteomes of the adult stage of the carcinogenic human liver fluke Opisthorchis viverriniPROTEINS: STRUCTURE, FUNCTION AND BIOINFORMATICS, Issue 5 2010Jason Mulvenna Abstract Infection with the human liver fluke, Opisthorchis viverrini, is a serious public health problem in Thailand, Laos and nearby locations in Southeast Asia. Both experimental and epidemiological evidence strongly implicate liver fluke infection in the etiology of one of the liver cancer subtypes, cholangiocarcinoma (CCA). To identify parasite proteins critical for liver fluke survival and the etiology of CCA, OFFGEL electrophoresis and multiple reaction monitoring were employed to characterize 300 parasite proteins from the O. viverrini excretory/secretory products and, utilizing selective labeling and sequential solubilization, from the host-exposed tegument. The excretory/secretory included a complex mixture of proteins that have been associated with cancers, including proteases of different mechanistic classes and orthologues of mammalian growth factors and anti-apoptotic proteins. Also identified was a cysteine protease inhibitor which, in other helminth pathogens, induces nitric oxide production by macrophages, and, hence may contribute to malignant transformation of inflamed cells. More than 160 tegumental proteins were identified using sequential solubilization of isolated teguments, and a subset of these was localized to the surface membrane of the tegument by labeling living flukes with biotin and confirming surface localization with fluorescence microscopy. These included annexins, which are potential immuno-modulators, and orthologues of the schistosomiasis vaccine antigens Sm29 and tetraspanin-2. Novel roles in pathogenesis were suggested for the tegument,host interface since more than ten surface proteins had no homologues in the public databases. The O. viverrini proteins identified here provide an extensive catalogue of novel leads for research on the pathogenesis of opisthorchiasis and the development of novel interventions for this disease and CCA, as well as providing a scaffold for sequencing the genome of this fluke. [source] Glutathione- S -transferase pi as a model protein for the characterisation of chemically reactive metabolitesPROTEINS: STRUCTURE, FUNCTION AND BIOINFORMATICS, Issue 2 2008Rosalind E. Jenkins Dr. Abstract Chemically reactive metabolites (CRMs) are thought to be responsible for a number of adverse drug reactions through modification of critical proteins. Methods that defined the chemistry of protein modification at an early stage would provide invaluable tools for drug safety assessment. Here, human GST pi (GSTP) was exploited as a model target protein to determine the chemical, biochemical and functional consequences of exposure to the hepatotoxic CRM of paracetamol (APAP), N -acetyl- p -benzoquinoneimine (NAPQI). Site-specific, dose-dependent modification of Cys47 in native and His-tagged GSTP was revealed by MS, and correlated with inhibition of glutathione (GSH) conjugating activity. In addition, the adaptation of iTRAQ labelling technology to define precisely the quantitative relationship between covalent modification and protein function is described. Multiple reaction monitoring (MRM)-MS of GSTP allowed high sensitivity detection of modified peptides at physiological levels of exposure. Finally, a bioengineered mutant cytochrome P450 with a broad spectrum of substrate specificities was used in an in vitro reaction system to bioactivate APAP: in this model, GSTP trapped the CRM and exhibited both reduced enzyme activity and site-specific modification of the protein. These studies provide the foundation for the development of novel test systems to predict the toxicological potential of CRMs produced by new therapeutic agents. [source] Proteomics cataloging analysis of human expressed prostatic secretions reveals rich source of biomarker candidatesPROTEOMICS - CLINICAL APPLICATIONS, Issue 4 2008Runsheng Li Abstract Expressed prostatic secretions (EPS) contain proteins of prostate origin that may reflect the health status of the prostate and be used as diagnostic markers for prostate diseases including prostatitis, benign prostatic hyperplasia, and prostate cancer. Despite their importance and potential applications, a complete catalog of EPS proteins is not yet available. We, therefore, undertook a comprehensive analysis of the EPS proteome using 2-D micro-LC combined with MS/MS. Using stringent filtering criteria, we identified a list of 114 proteins with at least two unique-peptide hits and an additional 75 proteins with only a single unique-peptide hit. The proteins identified include kallikrein 2 (KLK2), KLK3 (prostate-specific antigen), KLK11, and nine cluster of differentiation (CD) molecules including CD10, CD13, CD14, CD26, CD66a, CD66c, CD 143, CD177, and CD224. To our knowledge, this list represents the first comprehensive characterization of the EPS proteome, and it provides a candidate biomarker list for targeted quantitative proteomics analysis using a multiple reaction monitoring (MRM) approach. To help prioritize candidate biomarkers, we constructed a protein,protein interaction network of the EPS proteins using Cytoscape (www.cytoscape.org), and overlaid the expression level changes from the Oncomine database onto the network. [source] Identification of circulating endorepellin LG3 fragment: Potential use as a serological biomarker for breast cancerPROTEOMICS - CLINICAL APPLICATIONS, Issue 1 2008Jong Wook Chang Abstract Comparative proteome analysis was performed on the cultured media of human nontumor and malignant breast cell lines, Hs578Bst and Hs578T, respectively, in search of a serological biomarker(s) for breast cancer. Proteins in the conditioned media were separated by 2-D PAGE and then visualized by silver-staining. Eight proteins changed differentially by more than two-fold were identified by MALDI-TOF/TOF MS. Among the proteins identified, the terminal laminin-like globular (LG3) domain of endorepellin, which was recently reported as an antiangiogenesis factor, was decreased in the cancer cell line. We confirmed the bone morphogenic protein-1 (BMP-1) mediated cleavage site on the N-terminus of endorepellin LG3 fragment. This finding suggests that the LG3 fragment is specifically released by a BMP-1 driven limited proteolytic process. The protein was also detected in plasma by Western blot analysis and selected reaction monitoring (SRM). The plasma level of the endorepellin LG3 fragment was significantly lower in breast cancer patients compared to healthy donors (p,=,0.017; n,=,12). The LG3 protein concentration in the control plasma was measured at approximately 3.7,pmol/mL compared to 1.8,pmol/mL in plasma from the cancer patients. We suggest that these results support the potential use of the endorepellin LG3 fragment as a new serological biomarker for breast cancer. [source] Development of a targeted adductomic method for the determination of polycyclic aromatic hydrocarbon DNA adducts using online column-switching liquid chromatography/tandem mass spectrometryRAPID COMMUNICATIONS IN MASS SPECTROMETRY, Issue 16 2010Rajinder Singh Human exposure to polycyclic aromatic hydrocarbons (PAHs) from sources such as industrial or urban air pollution, tobacco smoke and cooked food is not confined to a single compound, but instead to mixtures of different PAHs. The interaction of different PAHs may lead to additive, synergistic or antagonistic effects in terms of DNA adduct formation and carcinogenic activity resulting from changes in metabolic activation to reactive intermediates and DNA repair. The development of a targeted DNA adductomic approach using liquid chromatography/tandem mass spectrometry (LC/MS/MS) incorporating software-based peak picking and integration for the assessment of exposure to mixtures of PAHs is described. For method development PAH-modified DNA samples were obtained by reaction of the anti- dihydrodiol epoxide metabolites of benzo[a]pyrene, benzo[b]fluoranthene, dibenzo[a,l]pyrene (DB[a,l]P) and dibenz[a,h]anthracene with calf thymus DNA in vitro and enzymatically hydrolysed to 2,-deoxynucleosides. Positive LC/electrospray ionisation (ESI)-MS/MS collision-induced dissociation product ion spectra data showed that the majority of adducts displayed a common fragmentation for the neutral loss of 116 u (2,-deoxyribose) resulting in a major product ion derived from the adducted base. The exception was the DB[a,l]P dihydrodiol epoxide adduct of 2,-deoxyadenosine which resulted in major product ions derived from the PAH moiety being detected. Specific detection of mixtures of PAH-adducted 2,-deoxynucleosides was achieved using online column-switching LC/MS/MS in conjunction with selected reaction monitoring (SRM) of the [M+H]+ to [M+H,116]+ transition plus product ions derived from the PAH moiety for improved sensitivity of detection and a comparison was made to detection by constant neutral loss scanning. In conclusion, different PAH DNA adducts were detected by employing SRM [M+H,116]+ transitions or constant neutral loss scanning. However, for improved sensitivity of detection optimised SRM transitions relating to the PAH moiety product ions are required for certain PAH DNA adducts for the development of targeted DNA adductomic methods. Copyright © 2010 John Wiley & Sons, Ltd. [source] High-throughput metabolic stability studies in drug discovery by orthogonal acceleration time-of-flight (OATOF) with analogue-to-digital signal capture (ADC)RAPID COMMUNICATIONS IN MASS SPECTROMETRY, Issue 12 2010David G. Temesi Screening assays capable of performing quantitative analysis on hundreds of compounds per week are used to measure metabolic stability during early drug discovery. Modern orthogonal acceleration time-of-flight (OATOF) mass spectrometers equipped with analogue-to-digital signal capture (ADC) now offer performance levels suitable for many applications normally supported by triple quadruple instruments operated in multiple reaction monitoring (MRM) mode. Herein the merits of MRM and OATOF with ADC detection are compared for more than 1000 compounds screened in rat and/or cryopreserved human hepatocytes over a period of 3 months. Statistical comparison of a structurally diverse subset indicated good agreement for the two detection methods. The overall success rate was higher using OATOF detection and data acquisition time was reduced by around 20%. Targeted metabolites of diazepam were detected in samples from a CLint determination performed at 1,µM. Data acquisition by positive and negative ion mode switching can be achieved on high-performance liquid chromatography (HPLC) peak widths as narrow as 0.2,min (at base), thus enabling a more comprehensive first pass analysis with fast HPLC gradients. Unfortunately, most existing OATOF instruments lack the software tools necessary to rapidly convert the huge amounts of raw data into quantified results. Software with functionality similar to open access triple quadrupole systems is needed for OATOF to truly compete in a high-throughput screening environment. Copyright © 2010 John Wiley & Sons, Ltd. [source] Real-time reaction monitoring by probe electrospray ionization mass spectrometryRAPID COMMUNICATIONS IN MASS SPECTROMETRY, Issue 11 2010Zhan Yu Probe electrospray ionization (PESI) is a modified version of the electrospray ionization (ESI), where the capillary for sampling and spraying is replaced by a solid needle. High tolerance to salts and direct ambient sampling are major advantages of PESI compared with conventional ESI. In this study, PESI-MS was used to monitor some biological and chemical reactions in real-time, such as acid-induced protein denaturation, hydrogen/deuterium exchange (HDX) of peptides, and Schiff base formation. By using PESI-MS, time-resolved mass spectra and ion chromatograms can be obtained reproducibly. Real-time PESI-MS monitoring can give direct and detailed information on each chemical species taking part in reactions, and this is valuable for a better understanding of the whole reaction process and for the optimization of reaction parameters. PESI-MS can be considered as a potential tool for real-time reaction monitoring due to its simplicity in instrumental setup, direct sampling with minimum sample preparation and low sample consumption. Copyright © 2010 John Wiley & Sons, Ltd. [source] Feasibility of capillary liquid chromatography/microchip atmospheric pressure photoionization mass spectrometry in analyzing anabolic steroids in urine samplesRAPID COMMUNICATIONS IN MASS SPECTROMETRY, Issue 7 2010Linda L. Ahonen We examined the feasibility of capillary liquid chromatography/microchip atmospheric pressure photoionization tandem mass spectrometry (capLC/µAPPI-MS/MS) for the analysis of anabolic steroids in human urine. The urine samples were pretreated by enzymatic hydrolysis (with , -glucuronidase from Helix pomatia), and the compounds were liquid-liquid extracted with diethyl ether. After separation the compounds were vaporized by microchip APPI, photoionized by a 10,eV krypton discharge lamp, and detected by selected reaction monitoring. The capLC/µAPPI-MS/MS method showed good sensitivity with detection limits at the level of 1.0,ng,mL,1, good linearity with correlation coefficients between 0.9954 and 0.9990, and good repeatability with relative standard deviations below 10%. These results demonstrate that microchip APPI combined with capLC/MS/MS provides a new potential method for analyzing non-polar and neutral compounds in biological samples. Copyright © 2010 John Wiley & Sons, Ltd. [source] Identification of circulatory and excretory metabolites of meisoindigo in rat plasma, urine and feces by high-performance liquid chromatography coupled with positive electrospray ionization tandem mass spectrometryRAPID COMMUNICATIONS IN MASS SPECTROMETRY, Issue 6 2010Meng Huang Meisoindigo has been a routine therapeutic agent in the clinical treatment of chronic myelogenous leukemia in China since the 1980s. However, information relevant to in vivo metabolism of meisoindigo is absent so far. In this study, in vivo circulatory metabolites of meisoindigo in rat plasma, as well as excretory metabolites in rat urine and feces, were identified by liquid chromatography/tandem mass spectrometry (LC/MS/MS). Integration of multiple reaction monitoring with conventional metabolic profiling methodology was adopted to enable a more sensitive detection of in vivo metabolites. By comparing with the MS/MS spectra and retention times of the in vitro reduced metabolites, the major metabolites in rat plasma were proposed to form from 3,3, double bond reduction, whereas the minor metabolites were formed from reduction followed by N-demethylation, and reduction followed by phenyl mono-oxidation. The major metabolites in the rat urine were proposed to form from reduction followed by phenyl mono-oxidation, and its glucuronide conjugation and sulfate conjugation, whereas the minor metabolites were formed from 3,3, double bond reduction, N-demethylation, reduction followed by N-demethylation, phenyl di-oxidation, phenyl mono-oxidation and its glucuronide conjugation and sulfate conjugation. The major metabolites in the rat feces were proposed to form from reduction followed by phenyl mono-oxidation, whereas the minor metabolites were formed from reduction followed by N-demethylation, and reduction followed by phenyl di-oxidation. The phase I metabolic pathways showed a significant in vitro,in vivo correlation in rat. Copyright © 2010 John Wiley & Sons, Ltd. [source] Increasing high-throughput Discovery bioanalysis using automated selected reaction monitoring compound optimization, ultra-high-pressure liquid chromatography, and single-step sample preparation workflowsRAPID COMMUNICATIONS IN MASS SPECTROMETRY, Issue 21 2009James Smalley QuickQuan is an integrated software package for Thermo Scientific triple quadrupole mass spectrometers that allows users to automate routine operations ranging from method development to data processing. QuickQuan automated optimization of compound-selected reaction monitoring (SRM) transitions by evaluating both positive and negative polarities during an infusion. Whichever mode produces the most intense Q1 scan is then carried to product ion spectra. QuickQuan then writes these SRM methods to a shared network database. The total volume of compound needed is 100,µL infused over approximately 1.6,min. The auto-optimization is carried out in 96-well plates and does not require an operator present. The SRM database was shared between two identical TSQ Quantum mass spectrometers. For data acquisition, QuickQuan automatically created a sequence file complete with a data processing method pre-populated with compound IDs and corresponding SRM transitions. To increase throughput we coupled each Finnigan Quantum with ultra-high-pressure liquid chromatography (uHPLC) accomplished using 4× Ultra Flux quaternary pumps that were designed to handle pressures up to 15 000,psi. The total run time for all analyses was 1.2,min using BEH 1.7,µm particle C18 columns. Further time reductions were realized with sample preparation accomplished using Strata Impact protein precipitation plates which provided an in-well protein crash and 0.20 micron filtering in a one-step process. Pharmacokinetic data turnaround time was significantly improved by combining these three techniques of automated method development with the speed efficiency of uHPLC and a single step in well sample preparation. Copyright © 2009 John Wiley & Sons, Ltd. [source] Multi-residue analysis of eight thioamphetamine designer drugs in human urine by liquid chromatography/tandem mass spectrometryRAPID COMMUNICATIONS IN MASS SPECTROMETRY, Issue 19 2009Maria Nieddu An analytical procedure for the simultaneous determination in human urine of several thioamphetamine designer drugs (2C-T and ALEPH series) is reported. The quantitative analysis was performed by liquid chromatography/tandem mass spectrometry and has been fully validated. The mass spectrometer was operated in positive-ion, selected reaction monitoring (SRM) mode. In order to minimize interferences with matrix components and to preconcentrate target analytes, solid-phase extraction was introduced in the method as a clean-up step. The entire method was validated for selectivity, linearity, precision and accuracy. The method turned out to be specific, sensitive, and reliable for the analysis of amphetamine derivatives in urine samples. The calibration curves were linear over the concentration range of 1 to 100,ng,mL,1 for all drugs with correlation coefficients that exceeded 0.996. The lower limits of detection (LODs) and quantification (LOQs) ranged from 1.2 to 4.9,ng,mL,1 and from 3.2 to 9.6,ng,mL,1, respectively. Copyright © 2009 John Wiley & Sons, Ltd. [source] Electrospray ionisation with selected reaction monitoring for the determination of Mn-citrate, Fe-citrate, Cu-citrate and Zn-citrateRAPID COMMUNICATIONS IN MASS SPECTROMETRY, Issue 15 2009Volker Nischwitz Citrate complexes of Mn and Fe, and potentially those of Cu and Zn, are considered as important low molecular mass species in human serum and cerebrospinal fluid (CSF). For example, Mn is supposed to enter the brain under excess exposure as Mn-citrate leading to neurotoxic effects. Mn-citrate has been characterised in human CSF using chromatography and electrophoresis online with inductively coupled plasma mass spectrometry, but not yet with molecular mass spectrometry. Therefore, this study explores the potential of electrospray ionisation (ESI) with selected reaction monitoring (SRM) for the detection of metal-citrate complexes, in particular Mn-citrate. The collision-induced dissociation of precursor ions with various metal:citrate stoichiometries was studied for Mn-citrate, Fe-citrate, Cu-citrate and Zn-citrate. High selectivity was achieved for Mn(II)-citrate even in respect to Fe(III)-citrate which forms isobaric precursor ions. The limit of detection for Mn-citrate was estimated to be around 250,µg,L,1 (referring to the total Mn content in the standard) using flow injection. The sensitivity was sufficient for the determination of Mn-citrate in standard solutions and in an extract of an Mn-citrate-containing supplement. An improved ESI source design is expected to reduce the limits of detection significantly. The developed ESI-SRM method has the potential to provide complementary data for the quality control of current separation methods for metal citrates using element-selective detection, with application to biomedical samples and further matrices. Copyright © 2009 John Wiley & Sons, Ltd. [source] Phospholipids in liquid chromatography/mass spectrometry bioanalysis: comparison of three tandem mass spectrometric techniques for monitoring plasma phospholipids, the effect of mobile phase composition on phospholipids elution and the association of phospholipids with matrix effectsRAPID COMMUNICATIONS IN MASS SPECTROMETRY, Issue 14 2009Yuan-Qing Xia Because plasma phospholipids may cause matrix effects in bioanalytical liquid chromatography/tandem mass spectrometry (LC/MS/MS) methods, it is important to establish optimal mass spectrometric techniques to monitor the fate of phospholipids during method development and application. We evaluated three MS/MS techniques to monitor phospholipids using positive and negative electrospray ionization (ESI). The first technique is based on using positive precursor ion scan of m/z 184, positive neutral loss scan of 141 Da and negative precursor ion scan of m/z 153. The second technique is based on using class-specific positive and negative selected reaction monitoring (SRM) transitions to monitor class-representative phospholipids. The third technique, previously reported, utilizes in-source collision-induced dissociation (CID)-based positive SRM of m/z 184,,,184. We recommend the all-inclusive technique 1 for use in qualitative assessment of all classes of phospholipids and technique 2 for use in quantitative assessment of class-representative phospholipids. Secondly, we evaluated the elution behaviors of the plasma phospholipids under different reversed-phase mobile phase conditions. The phospholipid-eluting strength of a mobile phase was mainly dependent on the type and amount (%) of the organic eluent and the strength increased in the order of methanol, acetonitrile and isopropyl alcohol. Under the commonly used gradient and isocratic elution schemes in LC/MS/MS bioanalysis, not all the phospholipids are eluted off the column. Thirdly, we investigated the association between phospholipids and matrix effects in positive and negative ESI using basic, acidic and neutral analytes. While the phospholipids caused matrix effects in both positive and negative ESI, the extent of ionization suppression was analyte-dependent and was inversely related to the retention factor and broadness of the phospholipids peaks. The lysophospholipids which normally elute earlier in reversed-phase chromatography are more likely to cause matrix effects compared to the later-eluting phospholipids in spite of the larger concentrations of the latter in plasma. Copyright © 2009 John Wiley & Sons, Ltd. [source] |