Quadrupole Time-of-flight Mass Spectrometer (quadrupole + time-of-flight_mass_spectrometer)

Distribution by Scientific Domains


Selected Abstracts


Elucidation of fragmentation mechanisms involving transfer of three hydrogen atoms using a quadrupole time-of-flight mass spectrometer

JOURNAL OF MASS SPECTROMETRY (INCORP BIOLOGICAL MASS SPECTROMETRY), Issue 5 2001
Cornelis E. C. A. Hop
[source]


Top-down proteomics with a quadrupole time-of-flight mass spectrometer and collision-induced dissociation

RAPID COMMUNICATIONS IN MASS SPECTROMETRY, Issue 5 2009
Andrea Armirotti
With slight modifications of the instrumental parameters, we demonstrate that satisfactory top-down data can be obtained with collision-induced dissociation (CID) tandem mass spectrometry on a quadrupole time-of-flight (qTOF) instrument not originally designed for this purpose. Protein identification is achieved with both N- and C-terminal sequence tags and BLAST database searches. The accurate mass measurement of multiply charged fragment ions (mostly y and b-type) supplements the limited set of cleavage sites and provides a high degree of sequence coverage (90,100%). Post-translational modification issues can be addressed too. This approach might help those mass spectrometry (MS) core facilities that are not able to afford very high-resolution instruments, thus expanding the benefits of top-down protein analysis over the worldwide MS community. Copyright © 2009 John Wiley & Sons, Ltd. [source]


Liquid chromatography/mass spectrometry for metabonomics investigation of the biochemical effects induced by aristolochic acid in rats: the use of information-dependent acquisition for biomarker identification

RAPID COMMUNICATIONS IN MASS SPECTROMETRY, Issue 6 2008
Wan Chan
The toxic effects of oral administrations of nephrotoxic and carcinogenic aristolochic acid (AA) to male Sprague-Dawley rats were investigated by using high-performance liquid chromatography coupled with a quadrupole time-of-flight mass spectrometer. Analysis of the urine and plasma samples revealed distinct changes in the biochemical patterns in the AA-dosed rats. After peak finding and alignment, principal component analysis (PCA) and partial least-squares discriminant analysis (PLS-DA) were used for multivariate data analysis. Potential biomarkers were studied by high-resolution mass spectrometry (MS) and tandem mass spectrometry (MS/MS) analyses. The MS/MS spectra of all endogenous metabolites satisfying the pre-defined criteria were acquired in a single information-dependent acquisition (IDA) analysis, demonstrating that IDA was an efficient approach for structural elucidation in metabonomic studies. Citric acid and a glucuronide-containing metabolite were observed as potential biomarkers in rat urine. A significant increase in plasma creatinine concentration was also observed in the AA-dosed rats, which indicated that AA induced an adverse effect on the renal clearance function. Copyright © 2008 John Wiley & Sons, Ltd. [source]


Feasibility of different mass spectrometric techniques and programs for automated metabolite profiling of tramadol in human urine

RAPID COMMUNICATIONS IN MASS SPECTROMETRY, Issue 14 2006
Kati S. Hakala
The purpose of the study was to determine the advantages of different mass spectrometric instruments and commercially available metabolite identification programs for metabolite profiling. Metabolism of tramadol hydrochloride and the excretion of it and its metabolites into human urine were used as a test case because the metabolism of tramadol is extensive and well known. Accurate mass measurements were carried out with a quadrupole time-of-flight mass spectrometer (Q-TOF) equipped with a LockSpray dual-electrospray ionization source. A triple quadrupole mass spectrometer (QqQ) was applied for full scan, product ion scan, precursor ion scan and neutral loss scan measurements and an ion trap instrument for full scan and product ion measurements. The performance of two metabolite identification programs was tested. The results showed that metabolite programs are time-saving tools but not yet capable of fully automated metabolite profiling. Detection of non-expected metabolites, especially at low concentrations in a complex matrix, is still almost impossible. With low-resolution instruments urine samples proved to be challenging even in a search for expected metabolites. Many false-positive hits were obtained with the automated searching and manual evaluation of the resulting data was required. False positives were avoided by using the higher mass accuracy Q-TOF. Automated programs were useful for constructing product ion methods, but the time-consuming interpretation of mass spectra was done manually. High-quality MS/MS spectra acquired on the QqQ instrument were used for confirmation of the tramadol metabolites. Although the ion trap instrument is of undisputable benefit in MSn, the low mass cutoff of the ion trap made the identification of tramadol metabolites difficult. Some previously unreported metabolites of tramadol were found in the tramadol urine sample, and their identification was based solely on LC/MS and LC/MS/MS measurements. Copyright © 2006 John Wiley & Sons, Ltd. [source]


Increasing throughput and information content for in vitro drug metabolism experiments using ultra-performance liquid chromatography coupled to a quadrupole time-of-flight mass spectrometer

RAPID COMMUNICATIONS IN MASS SPECTROMETRY, Issue 6 2005
Jose Castro-Perez
The field of drug metabolism has been revolutionized by liquid chromatography/mass spectrometry (LC/MS) applications with new technologies such as triple quadrupoles, ion traps and time-of-flight (ToF) instrumentation. Over the years, these developments have often relied on the improvements to the mass spectrometer hardware and software, which has allowed users to benefit from lower levels of detection and ease-of-use. One area in which the development pace has been slower is in high-performance liquid chromatography (HPLC). In the case of metabolite identification, where there are many challenges due to the complex nature of the biological matrices and the diversity of the metabolites produced, there is a need to obtain the most accurate data possible. Reactive or toxic metabolites need to be detected and identified as early as possible in the drug discovery process, in order to reduce the very costly attrition of compounds in late-phase development. High-resolution, exact mass measurement plays a very important role in metabolite identification because it allows the elimination of false positives and the determination of non-trivial metabolites in a much faster throughput environment than any other standard current methodology available to this field. By improving the chromatographic resolution, increased peak capacity can be achieved with a reduction in the number of co-eluting species leading to superior separations. The overall enhancement in the chromatographic resolution and peak capacity is transferred into a net reduction in ion suppression leading to an improvement in the MS sensitivity. To investigate this, a number of in vitro samples were analyzed using an ultra-performance liquid chromatography (UPLC) system, with columns packed with porous 1.7,,m particles, coupled to a hybrid quadrupole time-of-flight (ToF) mass spectrometer. This technique showed very clear examples for fundamental gains in sensitivity, chromatographic resolution and speed of analysis, which are all important factors for the demands of today's HTS in discovery. Copyright © 2005 John Wiley & Sons, Ltd. [source]


The nature of collision-induced dissociation processes of doubly protonated peptides: comparative study for the future use of matrix-assisted laser desorption/ionization on a hybrid quadrupole time-of-flight mass spectrometer in proteomics

RAPID COMMUNICATIONS IN MASS SPECTROMETRY, Issue 22 2001
R. Cramer
Comparative MS/MS studies of singly and doubly charged electrospray ionization (ESI) and matrix-assisted laser desorption/ionization (MALDI) precursor peptide ions are described. The spectra from these experiments have been evaluated with particular emphasis on the data quality for subsequent data processing and protein/amino acid sequence identification. It is shown that, once peptide ions are formed by ESI or MALDI, their charge state, as well as the collision energy, is the main parameter determining the quality of collision-induced dissociation (CID) MS/MS fragmentation spectra of a given peptide. CID-MS/MS spectra of singly charged peptides obtained on a hybrid quadrupole orthogonal time-of-flight mass spectrometer resemble very closely spectra obtained by matrix-assisted laser desorption/ionization post-source decay time-of-flight mass spectrometry (MALDI-PSD-TOFMS). On the other hand, comparison of CID-MS/MS spectra of either singly or doubly charged ion species shows no dependence on whether ions have been formed by ESI or MALDI. This observation confirms that, at the time of precursor ion selection, further mass analysis is effectively decoupled from the desorption/ionization event. Since MALDI ions are predominantly formed as singly charged species and ESI ions as doubly charged, the associated difference in the spectral quality of MS/MS spectra as described here imposes direct consequences on data processing, database searching using ion fragmentation data, and de novo sequencing when ionization techniques are changed. Copyright © 2001 John Wiley & Sons, Ltd. [source]


Liquid chromatography,mass spectrometry for analysis of a novel ,2 -adrenoceptor agonist trantinterol and its metabolites in beagle dog urine

BIOMEDICAL CHROMATOGRAPHY, Issue 3 2010
Yanjuan Wang
Abstract A liquid chromatography,tandem mass spectrometry method was developed for the identification of metabolites of trantinterol, a novel ,2 -adrenoceptor agonist, in beagle dog urine. The separation of metabolites was performed on a reversed-phase C8 column using 0.1% formic acid in water and methanol (70 : 30, v/v) as the mobile phase. The structural information and elemental information of metabolites were acquired by an electrospray ionization tandem mass spectrometer and a quadrupole time-of-flight mass spectrometer, respectively. A total of 13 metabolites were detected and characterized on the basis of their tandem MS/MS fragmentation patterns. The accurate masses of nine metabolites were determined and two metabolites were further confirmed by comparing with reference standards. The metabolic pathways of trantinterol in beagle dog are proposed. Copyright © 2009 John Wiley & Sons, Ltd. [source]