Home About us Contact | |||
Projection Reconstruction (projection + reconstruction)
Selected AbstractsImplications of bulk motion for diffusion-weighted imaging experiments: Effects, mechanisms, and solutionsJOURNAL OF MAGNETIC RESONANCE IMAGING, Issue 4 2001David G. Norris PhD Abstract This review article describes the effect of bulk motion on diffusion-weighted imaging experiments, and examines methods for correcting the resulting artifacts. The emphasis throughout the article is on two-dimensional imaging of the brain. The effects of translational and rotational motion on the MR signal are described, and the literature concerning pulsatile brain motion is examined. Methods for ameliorating motion effects are divided into three generic categories. The first is methods that should be intrinsically insensitive to macroscopic motion. These include motion-compensated diffusion-weighting schemes, single-shot EPI, projection reconstruction, and line scanning. Of these, only single-shot EPI and projection reconstruction methods can obtain high-quality images without compromising on sensitivity. The second category of methods is those that can be made insensitive to bulk motion. The methods examined here are FLASH and RARE. It is shown that for both sequences motion insensitivity is in general attained only at the cost of a 50% reduction in sensitivity. The final set of methods examined are those that correct for motion, primarily navigator echoes. The properties and limitations of the navigator echo approach are presented, as are those of methods which attempt to correct the acquired data by minimizing image artifacts. The review concludes with a short summary in which the current status of diffusion imaging in the presence of bulk motion is examined. J. Magn. Reson. Imaging 2001;13:486,495. © 2001 Wiley-Liss, Inc. [source] Sodium MRI using a density-adapted 3D radial acquisition techniqueMAGNETIC RESONANCE IN MEDICINE, Issue 6 2009Armin M. Nagel Abstract A density-adapted three-dimensional radial projection reconstruction pulse sequence is presented which provides a more efficient k -space sampling than conventional three-dimensional projection reconstruction sequences. The gradients of the density-adapted three-dimensional radial projection reconstruction pulse sequence are designed such that the averaged sampling density in each spherical shell of k -space is constant. Due to hardware restrictions, an inner sphere of k -space is sampled without density adaption. This approach benefits from both the straightforward handling of conventional three-dimensional projection reconstruction sequence trajectories and an enhanced signal-to-noise ratio (SNR) efficiency akin to the commonly used three-dimensional twisted projection imaging trajectories. Benefits for low SNR applications, when compared to conventional three-dimensional projection reconstruction sequences, are demonstrated with the example of sodium imaging. In simulations of the point-spread function, the SNR of small objects is increased by a factor 1.66 for the density-adapted three-dimensional radial projection reconstruction pulse sequence sequence. Using analytical and experimental phantoms, it is shown that the density-adapted three-dimensional radial projection reconstruction pulse sequence allows higher resolutions and is more robust in the presence of field inhomogeneities. High-quality in vivo images of the healthy human leg muscle and the healthy human brain are acquired. For equivalent scan times, the SNR is up to a factor of 1.8 higher and anatomic details are better resolved using density-adapted three-dimensional radial projection reconstruction pulse sequence. Magn Reson Med, 2009. © 2009 Wiley-Liss, Inc. [source] Generalized k -space decomposition with chemical shift correction for non-cartesian water-fat imagingMAGNETIC RESONANCE IN MEDICINE, Issue 5 2008Ethan K. Brodsky Abstract Chemical-shift artifacts associated with non-Cartesian imaging are more complex to model and less clinically acceptable than the bulk fat shift that occurs with conventional spin-warp Cartesian imaging. A novel k -space based iterative decomposition of water and fat with echo asymmetry and least-squares estimation (IDEAL) approach is introduced that decomposes multiple species while simultaneously correcting distortion of off-resonant species. The new signal model accounts for the additional phase accumulated by off-resonant spins at each point in the k -space acquisition trajectory. This phase can then be corrected by adjusting the decomposition matrix for each k -space point during the final IDEAL processing step with little increase in reconstruction time. The technique is demonstrated with water-fat decomposition using projection reconstruction (PR)/radial, spiral, and Cartesian spin-warp imaging of phantoms and human subjects, in each case achieving substantial correction of chemical-shift artifacts. Simulations of the point-spread-function (PSF) for off-resonant spins are examined to show the nature of the chemical-shift distortion for each acquisition. Also introduced is an approach to improve the signal model for species which have multiple resonant peaks. Many chemical species, including fat, have multiple resonant peaks, although such species are often approximated as a single peak. The improved multipeak decomposition is demonstrated with water-fat imaging, showing a substantial improvement in water-fat separation. Magn Reson Med 59:1151,1164, 2008. © 2008 Wiley-Liss, Inc. [source] Removing undersampling artifacts in DCE-MRI studies using independent components analysisMAGNETIC RESONANCE IN MEDICINE, Issue 4 2008A.L. Martel Abstract In breast MRI mammography both high temporal resolution and high spatial resolution have been shown to be important in improving specificity. Adaptive methods such as projection reconstruction time-resolved imaging of contrast kinetics (PR-TRICKS) allow images to be reconstructed at various temporal and spatial resolutions from the same data set. The main disadvantage is that the undersampling, which is necessary to produce high temporal resolution images, leads to the presence of streak artifacts in the images. We present a novel method of removing these artifacts using independent components analysis (ICA) and demonstrate that this results in a significant improvement in image quality for both simulation studies and for patient dynamic contrast-enhanced (DCE)-MRI images. We also investigate the effect of artifacts on two quantitative measures of contrast enhancement. Using simulation studies we demonstrate that streak artifacts lead to pronounced periodic oscillations in pixel concentration curves which, in turn, lead to increased errors and introduce bias into heuristic measurements. ICA filtering significantly reduces this bias and improves accuracy. Pharmacokinetic modeling was more robust and there was no evidence of bias due to the presence of streak artifacts. ICA filtering did not significantly reduce the errors in the estimated pharmacokinetic parameters; however, the chi-squared error was greatly reduced after ICA filtering. Magn Reson Med, 2008. © 2008 Wiley-Liss, Inc. [source] Self-navigated motion correction using moments of spatial projections in radial MRIMAGNETIC RESONANCE IN MEDICINE, Issue 2 2004Edward Brian Welch Abstract Interest in radial MRI (also known as projection reconstruction (PR) MRI) has increased recently for uses such as fast scanning and undersampled acquisitions. Additionally, PR acquisitions offer intrinsic advantages over standard two-dimensional Fourier transform (2DFT) imaging with respect to motion of the imaged object. It is well known that aligning each spatial domain projection's center of mass (calculated using the 0th and 1st moments) to the center of the field of view (FOV) corrects shifts caused by in-plane translation. In this work, a previously unrealized ability to determine the in-plane rotational motion of an imaged object using the 2nd moments of the spatial domain projections in conjunction with a specific projection angle acquisition time order is reported. We performed the correction using only the PR data itself acquired with the newly proposed projection angle acquisition time order. With the proposed view angle acquisition order, the acquisition is "self-navigating" with respect to both in-plane translation and rotation. We reconstructed the images using the aligned projections and detected acquisition angles to significantly reduce image artifacts due to such motion. The theory of the correction technique is described, and its effectiveness is demonstrated in phantom and in vivo experiments. Magn Reson Med 52:337,345, 2004. © 2004 Wiley-Liss, Inc. [source] |