Probe Orientation (probe + orientation)

Distribution by Scientific Domains


Selected Abstracts


What You See (Sonographically) Is What You Get: Vein and Patient Characteristics Associated With Successful Ultrasound-guided Peripheral Intravenous Placement in Patients With Difficult Access

ACADEMIC EMERGENCY MEDICINE, Issue 12 2009
Nova L. Panebianco MD
Abstract Objectives:, Ultrasound (US) has been shown to facilitate peripheral intravenous (IV) placement in emergency department (ED) patients with difficult IV access (DIVA). This study sought to define patient and vein characteristics that affect successful US-guided peripheral IV placement. Methods:, This was a prospective observational study of US-guided IV placement in a convenience sample of DIVA patients in an urban, tertiary care ED. DIVA patients were defined as having any of the following: at least two failed IV attempts or a history of difficult access plus the inability to visualize or palpate any veins on physical exam. Patient characteristics (demographic information, vital signs, and medical history) were collected on enrolled patients. The relationships between patient characteristics, vein depth and diameter, US probe orientation, and successful IV placement were analyzed. Results:, A total of 169 patients were enrolled, with 236 attempts at access. Increasing vessel diameter was associated with a higher likelihood of success (odds ratio [OR] = 1.79 per 0.1-cm increase in vessel diameter, 95% confidence interval [CI] = 1.37 to 2.34). Increasing vessel depth did not affect success rates (OR = 0.96 per 0.1-cm increase of depth, 95% CI = 0.89 to 1.04) until a threshold depth of 1.6 cm, beyond which no vessels were successfully cannulated. Probe orientation and patient characteristics were unrelated to success. Conclusions:, Success was solely related to vessel characteristics detected with US and not influenced by patient characteristics or probe orientation. Successful DIVA was primarily associated with larger vessel, while vessel depth up to >1.6 cm and patient characteristics were unrelated to success. Clinically, if two vessels are identified at a depth of <1.6 cm, the larger diameter vessel, even if comparatively deeper, should yield the greatest likelihood of success. [source]


Anatomical information is needed in ultrasound imaging of muscle to avoid potentially substantial errors in measurement of muscle geometry

MUSCLE AND NERVE, Issue 5 2009
Menno R. Bénard MSc
Abstract This study validates two-dimensional (2D) ultrasound measurements of muscle geometry of the human medial gastrocnemius (GM) and investigates effects of probe orientation on errors in these measurements. Ultrasound scans of GM muscle belly were made both on human cadavers (n = 4) and on subjects in vivo (n = 5). For half of the cadavers, ultrasound scans obtained according to commonly applied criteria of probe orientation deviated 15° from the true fascicle plane. This resulted in errors of fascicle length and fascicle angle up to 14% and 23%, respectively. Fascicle-like structures were detectable over a wide range of probe tilt and rotation angles, but they did not always represent true fascicles. Errors of measurement were either linear or quadratic functions of tilt angle. Similar results were found in vivo. Therefore, we conclude that similar errors are likely to occur for in vivo measurements. For all cadavers, at the distal end of GM, the true fascicle plane was shown to be perpendicular to the distal aponeurosis. Using transverse images of GM to detect the curvature of the deep aponeurosis at the distal end of the muscle belly is a simple strategy to help identify the fascicle plane. For subsequent longitudinal imaging, probe alignment within this plane will help minimize measurement errors of fascicle length, fascicle angle, and muscle thickness. Muscle Nerve, 2009 [source]


Calibrated quantitative ultrasound imaging of skeletal muscle using backscatter analysis

MUSCLE AND NERVE, Issue 1 2008
Craig M. Zaidman MD
Abstract We evaluated the ability of an ultrasound method, which can characterize cardiac muscle pathology and has reliability across different imaging systems, to obtain calibrated quantitative estimates of backscatter of skeletal muscle. Our procedure utilized a tissue-mimicking phantom to establish a linear relationship between ultrasound grayscale and backscatter levels. We studied skeletal muscles of 82 adults: 45 controls and 37 patients with hereditary myopathies. We found that skeletal muscle ultrasound backscatter levels varied with probe orientation, age, and muscle contraction and pathology. Reliability was greater with the probe in longitudinal compared with transverse planes. Backscatter levels were higher in those >40 years of age, in muscle extension than flexion, and in myopathic patients than controls. Calibrated measurements of muscle backscatter have sensitivity and specificity in identifying and reliably measuring levels of skeletal muscle pathology. Muscle Nerve 38: 893,898, 2008 [source]


What You See (Sonographically) Is What You Get: Vein and Patient Characteristics Associated With Successful Ultrasound-guided Peripheral Intravenous Placement in Patients With Difficult Access

ACADEMIC EMERGENCY MEDICINE, Issue 12 2009
Nova L. Panebianco MD
Abstract Objectives:, Ultrasound (US) has been shown to facilitate peripheral intravenous (IV) placement in emergency department (ED) patients with difficult IV access (DIVA). This study sought to define patient and vein characteristics that affect successful US-guided peripheral IV placement. Methods:, This was a prospective observational study of US-guided IV placement in a convenience sample of DIVA patients in an urban, tertiary care ED. DIVA patients were defined as having any of the following: at least two failed IV attempts or a history of difficult access plus the inability to visualize or palpate any veins on physical exam. Patient characteristics (demographic information, vital signs, and medical history) were collected on enrolled patients. The relationships between patient characteristics, vein depth and diameter, US probe orientation, and successful IV placement were analyzed. Results:, A total of 169 patients were enrolled, with 236 attempts at access. Increasing vessel diameter was associated with a higher likelihood of success (odds ratio [OR] = 1.79 per 0.1-cm increase in vessel diameter, 95% confidence interval [CI] = 1.37 to 2.34). Increasing vessel depth did not affect success rates (OR = 0.96 per 0.1-cm increase of depth, 95% CI = 0.89 to 1.04) until a threshold depth of 1.6 cm, beyond which no vessels were successfully cannulated. Probe orientation and patient characteristics were unrelated to success. Conclusions:, Success was solely related to vessel characteristics detected with US and not influenced by patient characteristics or probe orientation. Successful DIVA was primarily associated with larger vessel, while vessel depth up to >1.6 cm and patient characteristics were unrelated to success. Clinically, if two vessels are identified at a depth of <1.6 cm, the larger diameter vessel, even if comparatively deeper, should yield the greatest likelihood of success. [source]