Peripheral Venous Cannulation (peripheral + venous_cannulation)

Distribution by Scientific Domains


Selected Abstracts


Vascular catheterization is difficult in infants with Down syndrome

ACTA ANAESTHESIOLOGICA SCANDINAVICA, Issue 1 2009
D. S. SULEMANJI
Background: Our aim was to compare difficulties in vascular access interventions in infants with and without Down Syndrome (DS) undergoing congenital heart surgery. Methods: The anesthesia records of infants with DS undergoing congenital heart surgery (Group DS, n=61) were reviewed and matched with records of infants without DS (Group ND, n=61). Vascular cannulation sites, the experience of the anesthesiologists performing each procedure, the number of clinicians who attempted each procedure until it was successfully performed, and the number of attempts for each catheterization were recorded. Results: The rate of unsuccessful peripheral venous cannulation in any of the four extremities was higher in Group DS (P=0.026). The success rate of radial artery cannulation was lower in Group DS (P=0.048). Although the total number of attempts for arterial cannulation was higher in Group DS, the difference was not statistically significant (P=0.058). However, in Group DS, the clinician who was able to cannulate the artery successfully required a significantly higher number of attempts at cannulation (P=0.011). For central venous catheterization, cannulation site and the number of attempts required before success was achieved were similar in both groups. The specialist-to-resident ratio was higher in Group DS (P=0.037). Conclusion: Our results indicate a trend toward clinicians having more difficulty performing arterial and peripheral venous catheterizations in infants with DS compared with performing the same procedure in infants without DS. Anesthesiologists should be prepared for catheterization difficulties in this patient population. In infants with DS, we recommend that catheterizations be performed by more experienced physicians. [source]


The FLACC behavioral scale for procedural pain assessment in children aged 5,16 years

PEDIATRIC ANESTHESIA, Issue 8 2008
STEFAN NILSSON MSN RN
Summary Objectives:, To evaluate the concurrent and construct validity and the interrater reliability of the Face, Legs, Activity, Cry and Consolability (FLACC) scale during procedural pain in children aged 5,16 years. Background:, Self-reporting of pain is considered to be the primary source of information on pain intensity for older children but a validated observational tool will provide augment information to self-reports during painful procedures. Methods:, Eighty children scheduled for peripheral venous cannulation or percutaneous puncture of a venous port were included. In 40 cases two nurses simultaneously and independently assessed pain by using the FLACC scale and in 40 cases one of these nurses assessed the child. All children scored the intensity of pain by using the Coloured Analogue Scale (CAS) and distress by the Facial Affective Scale (FAS). Results:, Concurrent validity was supported by the correlation between FLACC scores and the children's self-reported CAS scores during the procedure (r = 0.59, P < 0.05). A weaker correlation was found between the FLACC scores and children's self-reported FAS (r = 0.35, P < 0.05). Construct validity was demonstrated by the increase in median FLACC score to 1 during the procedure compared with 0 before and after the procedure (P < 0.001). Interrater reliability during the procedure was supported by adequate kappa statistics for all items and for the total FLACC scores (, = 0.85, P < 0.001). Conclusions:, The findings of this study support the use of FLACC as a valid and reliable tool for assessing procedural pain in children aged 5,16 years. [source]


Litigation related to anaesthesia: an analysis of claims against the NHS in England 1995,2007

ANAESTHESIA, Issue 7 2009
T. M. Cook
Summary The distribution of medico-legal claims in English anaesthetic practice is unreported. We studied National Health Service Litigation Authority claims related to anaesthesia since 1995. All claims were reviewed by three clinicians and variously categorised, including by type of incident, claimed outcome and cost. Anaesthesia-related claims account for 2.5% of all claims and 2.4% of the value of all claims. Of 841 relevant claims 366 (44%) were related to regional anaesthesia, 245 (29%) obstetric anaesthesia, 164 (20%) inadequate anaesthesia, 95 (11%) dental damage, 71 (8%) airway (excluding dental damage), 63 (7%) drug related (excluding allergy), 31 (4%) drug allergy related, 31 (4%) positioning, 29 (3%) respiratory, 26 (3%) consent, 21 (2%) central venous cannulation and 18 (2%) peripheral venous cannulation. Defining which cases are, from a medico-legal viewpoint, ,high risk' is uncertain, but the clinical categories with the largest number of claims were regional anaesthesia, obstetric anaesthesia, inadequate anaesthesia, dental damage and airway, those with the highest overall cost were regional anaesthesia, obstetric anaesthesia, and airway and those with the highest mean cost per closed claim were respiratory, central venous cannulation and drug error excluding allergy. The data currently available have limitations but offer useful information. A closed claims analysis similar to that in the USA would improve the clinical usefulness of analysis. [source]


Transillumination by light-emitting diode facilitates peripheral venous cannulations in infants and small children

ACTA ANAESTHESIOLOGICA SCANDINAVICA, Issue 8 2010
K. HOSOKAWA
Background: Transillumination facilitates the visualization of peripheral veins in infants and children. The clinical usefulness of light-emitting diode (LED)-powered devices has not been thoroughly studied. Methods: We randomly assigned 136 infants and children weighing <15 kg, undergoing general anesthesia, to red LED-powered transillumination (TM group, n=67) vs. the usual method (UM group, n=69) of peripheral venous cannulations. Venous puncture was performed following anesthesia induction with sevoflurane and nitrous oxide. The primary and secondary study endpoints were the rate of successful cannulations at initial attempt, and the duration of insertion attempts, respectively. Results: The median score of the estimated cannulation difficulty before attempted puncture was similar in both groups. The success rates at first attempt were 75% and 61% (NS) and mean±SD times to successful venous access were 47±34 and 68±66 s (NS) in the TM and UM groups, respectively. The cannulation procedures were completed significantly earlier in the TM group than in the UM group (hazard ratio, 1.59; 95% confidence interval, 1.03,2.47; P=0.03). In the subgroup of infants and children <2 years old, venous cannulation was successful at first attempt in 73% and 49% in the TM group (n=44) and in the UM group (n=47), respectively (P=0.03). Conclusions: LED-powered transillumination devices facilitated peripheral venous cannulations in small infants and children. [source]