Arterial Cannulation (arterial + cannulation)

Distribution by Scientific Domains


Selected Abstracts


A Prospective Comparison of Ultrasound-guided and Blindly Placed Radial Arterial Catheters

ACADEMIC EMERGENCY MEDICINE, Issue 12 2006
Stephen Shiver MD
Abstract Background Arterial cannulation for continuous blood-pressure measurement and frequent arterial-blood sampling commonly are required in critically ill patients. Objectives To compare ultrasound (US)-guided versus traditional palpation placement of arterial lines for time to placement, number of attempts, sites used, and complications. Methods This was a prospective, randomized interventional study at a Level 1 academic urban emergency department with an annual census of 78,000 patients. Patients were randomized to either palpation or US-guided groups. Inclusion criteria were any adult patient who required an arterial line according to the treating attending. Patients who had previous attempts at an arterial line during the visit, or who could not be randomized because of time constraints, were excluded. Enrollment was on a convenience basis, during hours worked by researchers over a six-month period. Patients in either group who had three failed attempts were rescued with the other technique for patient comfort. Statistical analysis included Fisher's exact, Mann-Whitney, and Student's t-tests. Results Sixty patients were enrolled, with 30 patients randomized to each group. Patients randomized to the US group had a shorter time required for arterial line placement (107 vs. 314 seconds; difference, 207 seconds; p = 0.0004), fewer placement attempts (1.2 vs. 2.2; difference, 1; p = 0.001), and fewer sites required for successful line placement (1.1 vs. 1.6; difference, 0.5; p = 0.001), as compared with the palpation group. Conclusions In this study, US guidance for arterial cannulation was successful more frequently and it took less time to establish the arterial line as compared with the palpation method. [source]


A Descriptive Comparison of Ultrasound-guided Central Venous Cannulation of the Internal Jugular Vein to Landmark-based Subclavian Vein Cannulation

ACADEMIC EMERGENCY MEDICINE, Issue 4 2010
Daniel Theodoro MD
Abstract Objectives:, The safest site for central venous cannulation (CVC) remains debated. Many emergency physicians (EPs) advocate the ultrasound-guided internal jugular (USIJ) approach because of data supporting its efficiency. However, a number of physicians prefer, and are most comfortable with, the subclavian (SC) vein approach. The purpose of this study was to describe adverse event rates among operators using the USIJ approach, and the landmark SC vein approach without US. Methods:, This was a prospective observational trial of patients undergoing CVC of the SC or internal jugular veins in the emergency department (ED). Physicians performing the procedures did not undergo standardized training in either technique. The primary outcome was a composite of adverse events defined as hematoma, arterial cannulation, pneumothorax, and failure to cannulate. Physicians recorded the anatomical site of cannulation, US assistance, indications, and acute complications. Variables of interest were collected from the pharmacy and ED record. Physician experience was based on a self-reported survey. The authors followed outcomes of central line insertion until device removal or patient discharge. Results:, Physicians attempted 236 USIJ and 132 SC cannulations on 333 patients. The overall adverse event rate was 22% with failure to cannulate being the most common. Adverse events occurred in 19% of USIJ attempts, compared to 29% of non,US-guided SC attempts. Among highly experienced operators, CVCs placed at the SC site resulted in more adverse events than those performed using USIJ (relative risk [RR] = 1.89, 95% confidence interval [CI] = 1.05 to 3.39). Conclusions:, While limited by observational design, our results suggest that the USIJ technique may result in fewer adverse events compared to the landmark SC approach. ACADEMIC EMERGENCY MEDICINE 2010; 17:416,422 © 2010 by the Society for Academic Emergency Medicine [source]


Vascular catheterization is difficult in infants with Down syndrome

ACTA ANAESTHESIOLOGICA SCANDINAVICA, Issue 1 2009
D. S. SULEMANJI
Background: Our aim was to compare difficulties in vascular access interventions in infants with and without Down Syndrome (DS) undergoing congenital heart surgery. Methods: The anesthesia records of infants with DS undergoing congenital heart surgery (Group DS, n=61) were reviewed and matched with records of infants without DS (Group ND, n=61). Vascular cannulation sites, the experience of the anesthesiologists performing each procedure, the number of clinicians who attempted each procedure until it was successfully performed, and the number of attempts for each catheterization were recorded. Results: The rate of unsuccessful peripheral venous cannulation in any of the four extremities was higher in Group DS (P=0.026). The success rate of radial artery cannulation was lower in Group DS (P=0.048). Although the total number of attempts for arterial cannulation was higher in Group DS, the difference was not statistically significant (P=0.058). However, in Group DS, the clinician who was able to cannulate the artery successfully required a significantly higher number of attempts at cannulation (P=0.011). For central venous catheterization, cannulation site and the number of attempts required before success was achieved were similar in both groups. The specialist-to-resident ratio was higher in Group DS (P=0.037). Conclusion: Our results indicate a trend toward clinicians having more difficulty performing arterial and peripheral venous catheterizations in infants with DS compared with performing the same procedure in infants without DS. Anesthesiologists should be prepared for catheterization difficulties in this patient population. In infants with DS, we recommend that catheterizations be performed by more experienced physicians. [source]


Hepatic arterial cannulation using the side holed catheter

JOURNAL OF SURGICAL ONCOLOGY, Issue 2 2005
Masashi Watanabe MD
Abstract Background Hepatic arterial infusion chemotherapy (HAIC) has been recognized as one of the effective treatments for patients with hepatic metastatic tumor. However it is difficult to perform HAIC in the long term without complications. This report describes the laparotomic approach using the side holed catheter, which is a novel method of implanting a catheter-port system. Methods and Results We designed a new anti-thrombotic catheter for HAIC. This catheter is tapered from 5F (diameter of shaft) to 3.3F (diameter at tip), and a side hole is opened 7 cm from the tip of catheter. This catheter is inserted from the gastroduodenal artery to the common hepatic artery (CHA), and the tip is put in the aorta or in the splenic artery. The side hole is adjusted distal to the CHA. In our surgical department, our new catheter was inserted in four patients at the time of their abdominal surgery. The cannulation was performed successfully in all patients. In two of them, HAIC was finished without problems at 6 months after starting, and two were still treated by HAIC at 9 and 8 months after starting. Conclusions Initial results from a study of a new method of implanting a catheter-port system in the hepatic artery using the new tapering side hole catheter suggest that this method may enable operators to avoid complicated selective coiling and may lower the incidence of hepatic artery occlusion in patients receiving long-term HAIC. J. Surg. Oncol. 2005;91:145,149. © 2005 Wiley-Liss, Inc. [source]


Validation of a tonometric noninvasive arterial blood pressure monitor in the intensive care setting

ANAESTHESIA, Issue 5 2003
L. A. Steiner
Summary Intra-arterial measurement is considered the gold standard for continuous, beat-to-beat arterial blood pressure monitoring. However, arterial cannulation can be difficult and may cause complications such as thrombosis and ischaemia. Recently, a tonometric system, the Colin CBM-7000 has been developed for noninvasive beat-to-beat measurement of arterial blood pressure from the radial artery. We assessed the level of agreement between the CBM-7000 and invasive radial artery measurements in 15 patients on a neuro-intensive care unit. Agreement of systolic, diastolic and mean arterial pressure values was limited, with ,,34% of mean arterial pressures differing by over 10 mmHg. In many cases, this was due to a downward drift of the noninvasive measurements over time. Furthermore, there was a tendency to underestimate low pressures and overestimate high pressures. In our opinion, the Colin CBM-7000 cannot be recommended for continuous blood pressure monitoring in the intensive care setting. [source]


A Novel Femoral Arterial Cannula to Prevent Limb Ischemia During Cardiopulmonary Support: Preliminary Report of Experimental and Clinical Experiences

ARTIFICIAL ORGANS, Issue 7 2006
Yoshiro Matsui
Abstract:, Distal limb ischemia may occur as a serious complication related to the use of femoral cannulation during veno-arterial cardiopulmonary support (CPS). We developed a simple cannula for femoral arterial cannulation with two holes in the side wall, which could provide the distal limb blood flow without additional cannulation or surgical procedure. This cannula can be inserted into the femoral artery by routine Seldinger technique. The distal blood flow from the side holes can be confirmed by Doppler detector without specialized techniques. In porcine experimental model, the distance between the position where the blood flow was first detected and those where the blood leakage took place was at least more than 10 mm. When this cannula and its side holes were adequately positioned, the mean distal limb flow ranged from 75 to 90 mL/min under CPS at a flow of 1.5 L/min. We employed this cannula for six patients in clinical settings. Three patients showed a good distal limb blood flow at the introduction position without its adjustment. The other three patients showed distal limb ischemia at the introduction position, but the limb ischemia was soon recovered after a slight adjustment of its position. There was no blood leakage from the percutaneous entry into the artery in all cases. We currently use this cannula as the first choice for patients undergoing a prolonged CPS. [source]