Home About us Contact | |||
Outer Aspect (outer + aspect)
Selected AbstractsCanal shapes produced sequentially during instrumentation with Quantec SC rotary nickel,titanium instruments: a study in simulated canalsINTERNATIONAL ENDODONTIC JOURNAL, Issue 2 2001I. T. Griffiths Abstract Aim The aim of this study was to determine the shaping ability of Quantec SC nickel,titanium rotary instruments in simulated root canals. Methodology Forty simulated canals consisting of four different shapes in terms of angle and position of curvature were prepared with Quantec SC instruments. Sequential still images were taken of the canals using a video camera attached to a computer with image analysis software. Images were taken preoperatively, and then after instrument 7 (Size 25, 0.05 taper), instrument 8 (size 25, 0.06 taper), and instrument 10 (size 45, 0.02 taper) were taken to length. Each sequential postoperative image was superimposed individually over the preoperative image in order to highlight the amount and position of material removed during preparation. Results Overall, the mean preparation time to size 10 was 3.6 min with 12 mm canals taking on average less time than 8 mm canals. There was a highly significant difference between the canal types (P < 0.0001). No instruments fractured within the canal or deformed, although one instrument separated from the latch grip. All canals remained patent. Following preparation to size 10, 19 canals (48%) retained their length, eight (20%) lost length, and 13 (32%) gained length; the magnitude of the change in length was always 0.5 mm or below. Following preparation to size 7 instruments all canals showed aberrant shapes. Excess removal of material along the outer aspect of the curve between the beginning of the curve and the end-point (outer widening) was found in 26 canals (65%) after instrument 7. At the same stage of preparation six canals (15%) had zips, three (8%) had ledges and five (13%) had perforations. Following preparation to size 10, 27 (68%) canals were perforated. Conclusions Under the conditions of the study, Quantec SC instruments consistently produced aberrations when canals were enlarged to size 7 (size 25, 0.05 taper) or above. Care should be exercised when using these instruments in real teeth. [source] Shaping ability of Hero 642 rotary nickel,titanium instruments in simulated root canals: Part 2INTERNATIONAL ENDODONTIC JOURNAL, Issue 3 2000S. A. Thompson Abstract Aim To determine the shaping ability of Hero 642 nickel,titanium rotary instruments during the preparation of simulated canals. Methodology A total of 40 simulated root canals made up of four different shapes, in terms of angle and position of curvature, were prepared by Hero 642 instruments using a crown-down preparation sequence. Pre- and postoperative images of the canals were taken using a video camera attached to a computer with image analysis software. The pre- and postoperative views were superimposed to highlight the amount and position of material removed during preparation. This report describes the efficacy of the instruments in terms of prevalence of canal aberrations, the amount and direction of canal transportation and overall postoperative shape. Results Four zips and four elbows were created during preparation, all in canals with 40°, 12 mm curves. No perforations or danger zones were created. Highly significant differences (P < 0.001) were apparent between the canal shapes in total canal width at the apex and beginning of the curve, and in the amount of resin removed from the inner and outer aspects of the curve at the orifice. Canal transportation was most frequently directed toward the outer aspect of the curve at specific points along the canal, except at the orifice, where it was apparent that canals with 20° curves transported toward the inner. Overall, mean absolute transportation was always less than 0.15 mm; however, significant differences occurred between canal shapes at the end-point (P < 0.01), apex of the curve (P < 0.01) and at the orifice (P < 0.01). Conclusions Under the conditions of this study, Hero 642 rotary nickel,titanium instruments created canals with few aberrations and no perforations. The relatively high proportion of aberrations in canals with short, acute curves may indicate that instruments with increased taper should be used with caution at or near the full working distance. Further research in real teeth is necessary to elucidate the full potential of these new rotary instruments for use in root canal preparation. [source] Stem cell markers (cytokeratin 15, CD34 and nestin) in primary scarring and nonscarring alopeciaBRITISH JOURNAL OF DERMATOLOGY, Issue 3 2009M.P. Hoang Summary Background, Although the pathogenesis of most primary scarring alopecias is poorly understood, recent studies implicate the bulge region as a possible target. Objectives, To corroborate these results, we ascertained involvement of follicular bulge stem cells using a panel of antibodies that putatively targeted the same. Methods, Antibodies used included anticytokeratin (CK) 15, CD34 and nestin on vertical and horizontal tissue sections of 50 cases of scarring and 34 cases of nonscarring alopecia. Results, Comparing expression of these markers in scarring vs. nonscarring alopecia, CK15 was noted in the follicular bulge region in 23 of 43 (53%) vs. 27 of 27 (100%) cases and in the peripheral layer of the outer root sheath (ORS) (upper two-thirds of the follicle) in 50 of 50 (100%) vs. 34 of 34 (100%) cases; CD34 was noted in the peripheral layer of the ORS (below pilar muscle attachment) in 24 of 35 (69%) vs. 18 of 18 (100%) cases; and nestin was noted in the infundibular region in 18 of 46 (39%) vs. seven of 32 (22%) cases and in the inner aspect of the ORS (below pilar muscle attachment) in eight of 31 (26%) vs. 23 of 23 (100%) cases. Conclusions, Our findings of differential follicular localization of stem cells underscore follicular progenitor cell heterogeneity and suggest the target in scarring alopecia is not merely follicular bulge stem cells but involves stem cells in the inner and outer aspect of the ORS. Enhanced expression of nestin in the infundibular region in scarring alopecia indicates availability of an accessible, in vivo niche of potential utility as an autologous source of stem cells for therapeutic application. [source] Shaping ability of Hero 642 rotary nickel,titanium instruments in simulated root canals: Part 2INTERNATIONAL ENDODONTIC JOURNAL, Issue 3 2000S. A. Thompson Abstract Aim To determine the shaping ability of Hero 642 nickel,titanium rotary instruments during the preparation of simulated canals. Methodology A total of 40 simulated root canals made up of four different shapes, in terms of angle and position of curvature, were prepared by Hero 642 instruments using a crown-down preparation sequence. Pre- and postoperative images of the canals were taken using a video camera attached to a computer with image analysis software. The pre- and postoperative views were superimposed to highlight the amount and position of material removed during preparation. This report describes the efficacy of the instruments in terms of prevalence of canal aberrations, the amount and direction of canal transportation and overall postoperative shape. Results Four zips and four elbows were created during preparation, all in canals with 40°, 12 mm curves. No perforations or danger zones were created. Highly significant differences (P < 0.001) were apparent between the canal shapes in total canal width at the apex and beginning of the curve, and in the amount of resin removed from the inner and outer aspects of the curve at the orifice. Canal transportation was most frequently directed toward the outer aspect of the curve at specific points along the canal, except at the orifice, where it was apparent that canals with 20° curves transported toward the inner. Overall, mean absolute transportation was always less than 0.15 mm; however, significant differences occurred between canal shapes at the end-point (P < 0.01), apex of the curve (P < 0.01) and at the orifice (P < 0.01). Conclusions Under the conditions of this study, Hero 642 rotary nickel,titanium instruments created canals with few aberrations and no perforations. The relatively high proportion of aberrations in canals with short, acute curves may indicate that instruments with increased taper should be used with caution at or near the full working distance. Further research in real teeth is necessary to elucidate the full potential of these new rotary instruments for use in root canal preparation. [source] |