Array Coil (array + coil)
Selected AbstractsDesign and development of a prototype endocavitary probe for high-intensity focused ultrasound delivery with integrated magnetic resonance imagingJOURNAL OF MAGNETIC RESONANCE IMAGING, Issue 3 2007Iain P. Wharton MRCS Abstract Purpose To integrate a high intensity focused ultrasound (HIFU) transducer with an MR receiver coil for endocavitary MR-guided thermal ablation of localized pelvic lesions. Materials and Methods A hollow semicylindrical probe (diameter 3.2 cm) with a rectangular upper surface (7.2 cm × 3.2 cm) was designed to house a HIFU transducer and enable acoustic contact with an intraluminal wall. The probe was distally rounded to ease endocavitary insertion and was proximally tapered to a 1.5-cm diameter cylindrical handle through which the irrigation tubes (for transducer cooling) and electrical connections were passed. MR compatibility of piezoceramic and piezocomposite transducers was assessed using gradient-echo (GRE) sequences. The radiofrequency (RF) tuning of identical 6.5 cm × 2.5 cm rectangular receiver coils on the upper surface of the probe was adjusted to compensate for the presence of the conductive components of the HIFU transducers. A T1-weighted (T1-W) sliding window dual-echo GRE sequence monitored phase changes in the focal zone of each transducer. High-intensity (2400 W/cm,2), short duration (<1.5 seconds) exposures produced subtherapeutic temperature rises. Results For T1-W images, signal-to-noise ratio (SNR) improved by 40% as a result of quartering the conductive surface of the piezoceramic transducer. A piezocomposite transducer showed a further 28% improvement. SNRs for an endocavitary coil in the focal plane of the HIFU trans-ducer (4 cm from its face) were three times greater than from a phased body array coil. Local shimming improved uniformity of phase images. Phase changes were detected at subtherapeutic exposures. Conclusion We combined a HIFU transducer with an MR receiver coil in an endocavitary probe. SNRs were improved by quartering the conductive surface of the piezoceramic. Further improvement was achieved with a piezocomposite transducer. A phase change was seen on MR images during both subtherapeutic and therapeutic HIFU exposures. J. Magn. Reson. Imaging 2007. © 2007 Wiley-Liss, Inc. [source] Transrectal ultrasound-guided biopsy of prostate voxels identified as suspicious of malignancy on three-dimensional 1H MR spectroscopic imaging in patients with abnormal digital rectal examination or raised prostate specific antigen level of 4,10 ng/mlNMR IN BIOMEDICINE, Issue 1 2007Virendra Kumar Abstract Results of the evaluation of transrectal ultrasound (TRUS) guided needle biopsy of voxels identified as suspicious of malignancy on magnetic resonance spectroscopic imaging (MRSI) in a large cohort of men (n,=,83) with abnormal digital rectal examination (DRE) [prostate specific antigen (PSA) 0,4,ng/ml] or PSA less than 10,ng/ml, are reported. Three-dimensional 1H MRSI was carried out at 1.5 T using a pelvic-phased array coil in combination with an endorectal surface coil. Voxels were classified as suspicious of malignancy based on Cit/(Cho,+,Cr) metabolite ratio. TRUS-guided biopsy of suspicious voxels was performed using the z - and x -coordinates obtained from MR images and two to three cores were taken from the suspected site. A systematic sextant biopsy was also carried out. MRSI showed voxels suspicious of malignancy in 44 patients while biopsy revealed cancer in 11 patients (25%). Patients who were negative for malignancy on MRSI were also negative on biopsy. An overall sensitivity of 100%, specificity of 54%, negative predictive value of 100% and accuracy of 60% were obtained. The site of biopsy was confirmed (n,=,20) as a hypo-intense area on repeat MRI while repeat MRSI revealed high choline and low citrate. The overall success rate of MRI-directed TRUS-guided biopsy of 25% was higher compared with a 9% success rate achieved without MR guidance in another group of 120 patients. Our results indicate that TRUS-guided biopsy of suspicious area identified as malignant from MRSI can be performed using the coordinates of the voxel derived from MR images. This increases the detection rate of prostate cancer in men with PSA level <10,ng/ml or abnormal DRE and also demonstrates the potential of MR in routine clinical practice. Copyright © 2006 John Wiley & Sons, Ltd. [source] Magnetic resonance microscopy of the equine hoof wall: a study of resolution and potentialEQUINE VETERINARY JOURNAL, Issue 5 2006M. D. KELLER Summary Reasons for performing study: Obtaining magnetic resonance images of the inner hoof wall tissue at the microscopic level would enable early accurate diagnosis of laminitis and therefore more effective therapy. Objectives: To optimise magnetic resonance imaging (MRI) parameters in order to obtain the highest possible resolution of the structures beneath the equine hoof wall. Methods: Magnetic resonance microscopy (MRM) was performed in front feet from 6 cadaver horses using T2 -weighted fast spin echo (FSE-T2), and T1 -weighted gradient echo (GRE-T1) sequences. Results: In T2 weighted FSE images most of the stratum medium showed no signal, however the coronary, terminal and sole papillae were visible. The stratum lamellatum was clearly visible and primary epidermal lamellae could be differentiated from dermal lamellae. Conclusion: Most structures beneath the hoof wall were differentiated. Conventional scanners for diagnostic MRI in horses are low or high field. However this study used ultra-high field scanners currently not available for clinical use. Signal-to-noise ratio (S/N) increases as a function of field strength. An increase of spatial resolution of the image results in a decreased S/N. S/N can also be improved with better coils and the resolution of high field MRI scanners will increase as technology develops and surface array coils become more readily available. Potential relevance: Although MR images with microscopic resolution were obtained ex vivo, this study demonstrates the potential for detection of lamellar pathology as it occurs. Early recognition of the development of laminitis to instigate effective therapy at an earlier stage and may improve the outcome for laminitic horses. Clinical MR is now readily available at 3 T, while 4 T, 7 T and 9 T systems are being used for human whole body applications. [source] 96-Channel receive-only head coil for 3 Tesla: Design optimization and evaluationMAGNETIC RESONANCE IN MEDICINE, Issue 3 2009Graham C. Wiggins Abstract The benefits and challenges of highly parallel array coils for head imaging were investigated through the development of a 3T receive-only phased-array head coil with 96 receive elements constructed on a close-fitting helmet-shaped former. We evaluated several designs for the coil elements and matching circuitry, with particular attention to sources of signal-to-noise ratio (SNR) loss, including various sources of coil loading and coupling between the array elements. The SNR and noise amplification (g -factor) in accelerated imaging were quantitatively evaluated in phantom and human imaging and compared to a 32-channel array built on an identical helmet-shaped former and to a larger commercial 12-channel head coil. The 96-channel coil provided substantial SNR gains in the distal cortex compared to the 12- and 32-channel coils. The central SNR for the 96-channel coil was similar to the 32-channel coil for optimum SNR combination and 20% lower for root-sum-of-squares combination. There was a significant reduction in the maximum g -factor for 96 channels compared to 32; for example, the 96-channel maximum g -factor was 65% of the 32-channel value for acceleration rate 4. The performance of the array is demonstrated in highly accelerated brain images. Magn Reson Med, 2009. © 2009 Wiley-Liss, Inc. [source] |