Home About us Contact | |||
Organ Perfusion (organ + perfusion)
Selected AbstractsNegative impact of systemic catecholamine administration on hepatic blood perfusion after porcine liver transplantationLIVER TRANSPLANTATION, Issue 2 2005Arianeb Mehrabi Catecholamines are often administered during and after liver transplantation (LTx) to support systemic perfusion and to increase organ oxygen supply. Some vasoactive agents can compromise visceral organ perfusion. We followed the hypothesis that the vasculature of transplanted livers presents with a higher sensitivity, which leads to an increased vulnerability for flow derangement after application of epinephrine (Epi) or norepinephrine (NorEpi). Hepatic macroperfusion and microperfusion during systemic Epi or NorEpi infusion were measured by Doppler flow and thermodiffusion probes in porcine native, denervated, and transplanted livers (n = 16 in each group). Epi or NorEpi were infused (n = 8 in each subgroup) in predefined dosages (low dose = 5 ,g/kg/minute and high dose = 10 ,g/kg/minute) over 240 minutes. Systemic cardiocirculatory parameters were monitored continuously. Hepatic perfusion data were compared between all groups at comparable time points and dosages. In all native, denervated, and transplanted liver groups, Epi and NorEpi induced an inconsistent rise of mean arterial pressure and heart rate shortly after onset of infusion in both dosages compared with baseline. No significant differences of cardiovascular parameters at comparable time points were observed. In native livers, Epi and NorEpi induced only temporary alterations of hepatic macrocirculation and microcirculation, which returned to baseline 2 hours after onset of infusion. No significant alterations of hepatic blood flow were detected after isolated surgical denervation of the liver. By contrast, transplanted livers showed a progressive decline of hepatic macrocirculation (33,75% reduction) and microcirculation (39,58% reduction) during catecholamine infusions in a dose-dependent fashion. Characteristics of liver blood flow impairment were comparable for both vasoactive agents. In conclusion, pronounced disturbances of hepatic macrocirculation and microcirculation were observed during systemic Epi and NorEpi infusion after LTx compared with native and denervated livers. Microcirculation disturbances after LTx might be explained by impairment of hepatic blood flow regulation caused by an increased sensitivity of hepatic vasculature after ischemia-reperfusion and by lengthening of vasopressor effects caused by reduced hepatocyte metabolism. Clinicians should be aware of this potentially hazardous effect. Therefore, application of catecholamines after clinical LTx should be indicated carefully. (Liver Transpl 2005;11:174,187.) [source] Fluid resuscitation from severe hemorrhagic shock using diaspirin cross-linked hemoglobin fails to improve pancreatic and renal perfusionACTA ANAESTHESIOLOGICA SCANDINAVICA, Issue 10 2004A. Pape Background:, Fluid resuscitation from hemorrhagic shock is intended to abolish microcirculatory disorders and to restore adequate tissue oxygenation. Diaspirin cross-linked hemoglobin (DCLHb) is a hemoglobin-based oxygen carrier (HBOC) with vasoconstrictive properties. Therefore, fluid resuscitation from severe hemorrhagic shock using DCLHb was expected to improve perfusion pressure and tissue perfusion of kidneys and pancreas. Methods:, In 20 anesthetized domestic pigs with an experimentally induced coronary stenosis, shock (mean arterial pressure 45 mmHg) was induced by controlled withdrawal of blood and maintained for 60 min. Fluid resuscitation (replacement of the plasma volume withdrawn during hemorrhage) was performed with either 10% DCLHb (DCLHb group, n = 10) or 8% human serum albumin (HSA) oncotically matched to DCLHb (HSA group, n = 10). Completion of resuscitation was followed by a 60-min observation period. Regional blood flow to the kidneys and the pancreas was measured by use of the radioactive microspheres method at baseline, after shock and 60 min after fluid resuscitation. Results:, All animals (10/10) resuscitated with DCLHb survived the 60-min observation period, while 5/10 control animals died within 20 min due to persisting subendocardial ischemia. In contrast to HSA survivors, pancreas and kidneys of DCLHb-treated animals revealed lower total and regional organ perfusion and regional oxygen delivery. Renal and pancreatic blood flow heterogeneity was higher in the DCLHb group. Conclusion:, DCLHb-induced vasoconstriction afforded superior myocardial perfusion, but impaired regional perfusion of the kidneys and the pancreas. [source] The Impact of Aortic/Subclavian Outflow Cannulation for Cardiopulmonary Bypass and Cardiac Support: A Computational Fluid Dynamics StudyARTIFICIAL ORGANS, Issue 9 2009Tim A.S. Kaufmann Abstract Approximately 100 000 cases of oxygen deficiency in the brain occur during cardiopulmonary bypass (CPB) procedures each year. In particular, perfusion of the carotid and vertebral arteries is affected. The position of the outflow cannula influences the blood flow to the cardiovascular system and thus end organ perfusion. Traditionally, the cannula returns blood into the ascending aorta. But some surgeons prefer cannulation to the right subclavian artery. A computational fluid dynamics study was initially undertaken for both approaches. The vessel model was created from real computed tomography/magnetic resonance imaging data of young healthy patients. The simulations were run with usual CPB conditions. The flow distribution for different cannula positions in the aorta was studied, as well as the impact of the cannula tip distance to vertebral artery for the subclavian position. The study presents a fast method of analyzing the flow distribution in the cardiovascular system, and can be adapted for other applications such as ventricular assist device support. It revealed that two effects cause the loss of perfusion seen clinically: a vortex under the brachiocephalic trunk and low pressure regions near the cannula jet. The results suggest that cannulation to the subclavian artery is preferred if the cannula tip is sufficiently far away from the branch of the vertebral artery. For the aortic positions, however, the cannula should be injected from the left body side. [source] IDENTIFICATION OF BLOOD PRESSURE CONTROL MECHANISMS BY POWER SPECTRAL ANALYSISCLINICAL AND EXPERIMENTAL PHARMACOLOGY AND PHYSIOLOGY, Issue 4 2007Harald M Stauss SUMMARY 1Blood pressure and organ perfusion are controlled by a variety of cardiovascular control systems, such as the baroreceptor reflex and the renin,angiotensin system (RAS), and by local vascular mechanisms, such as shear stress-induced release of nitric oxide (NO) from the endothelium and the myogenic vascular response. Deviations in arterial blood pressure from its set point activate these mechanisms in an attempt to restore blood pressure and/or secure organ perfusion. However, the response times at which different cardiovascular mechanisms operate differ considerably (e.g. blood pressure control by the RAS is slower than blood pressure control via the baroreceptor reflex). 2Owing to these different response times, some cardiovascular control systems affect blood pressure more rapidly and others more slowly. Thus, identifying the frequency components of blood pressure variability (BPV) by power spectral analysis can potentially provide important information on individual blood pressure control mechanisms. 3Evidence is presented that the RAS, catecholamines, endothelial-derived NO and myogenic vascular function affect BPV at very low frequencies (0.02,0.2 Hz) and that low-frequency (LF) BPV (0.2,0.6 Hz) is affected by sympathetic modulation of vascular tone and endothelial-derived NO in rats. In humans, LF BPV (0.075,0.15 Hz) is affected by sympathetic modulation of vascular tone and myogenic vascular function. The impact of the RAS and endothelial-derived NO on BPV in humans requires further investigation. 4In conclusion, power spectral analysis is a powerful diagnostic tool that allows identification of pathophysiological mechanisms contributing to cardiovascular diseases, such as hypertension, heart failure and stroke, because it can separate slow from fast cardiovascular control mechanisms. The limitation that some cardiovascular control mechanisms affect the same frequency components of BPV requires the combination of blood pressure spectral analysis with other techniques. [source] |