Observers Used (observer + used)

Distribution by Scientific Domains


Selected Abstracts


Experimental validation of a high-gain observer for composition estimation in an ethanol,water distillation column

ASIA-PACIFIC JOURNAL OF CHEMICAL ENGINEERING, Issue 6 2009
A. C. Téllez-Anguiano
Abstract In this paper a high-gain observer used to estimate the product compositions in a distillation column for a non-ideal mixture (ethanol,water) through the tray temperature measurements is presented. The design of this observer is based on a simplified mathematical model. One of the main advantages of this observer is its constant gain, therefore its tuning depends only on choosing a few constant parameters satisfying some simple algebraic inequalities. The effectiveness of the proposed method is demonstrated through on-line experiments in a distillation pilot plant. Copyright © 2009 Curtin University of Technology and John Wiley & Sons, Ltd. [source]


Detection of artificially induced vertical radicular fractures using Tuned Aperture Computed Tomography

EUROPEAN JOURNAL OF ORAL SCIENCES, Issue 6 2001
Madhu K. Nair
This study compared the accuracy of three imaging modalities for the detection of artificially induced vertical root fractures (VRF) on teeth in cadaver mandibles. Fifty-four single-rooted, endodontically treated mandibular teeth being prepared to carry posts were evaluated using direct digital radiography (DDI) with a Schick sensor, unprocessed Tuned Aperture Computed Tomography® (TACT-U) images and iteratively restored TACT (TACT-IR) images. Twenty-eight of these teeth had been subjected to fracture induction using an apically driven force. Nine basis images were used for each TACT image generation. Eight observers used a five-point confidence rating scale to record the confidence with which they considered a fracture to be present or not. Sensitivity and specificity values were computed and receiver operating characteristic (ROC) curves were generated. The areas under the curves (Az) used as an indication of the diagnostic accuracy of the imaging system were as follows: DDI: 0.37; TACT-U: 0.77 and TACT-IR: 0.81. DDI was significantly inferior to the TACT modalities. Differences in detection efficacy based on observers and observation sessions were noted on ANOVA and post-hoc Tukey's tests. This study indicates that TACT is the imaging modality of choice for VRF in endodontically treated teeth. [source]


Corticosteroid Treatment for Idiopathic Facial Nerve Paralysis: A Meta-analysis,

THE LARYNGOSCOPE, Issue 3 2000
Mitchell Jay Ramsey CPT
Abstract Objective A meta-analysis was designed to evaluate facial recovery in patients with complete idiopathic facial nerve paralysis (IFNP) by comparing outcomes of those treated with corticosteroid therapy with outcomes of those treated with placebo or no treatment. Study Design Meta-analysis of prospective trials evaluating corticosteroid therapy for idiopathic facial nerve paralysis. Methods A protocol was followed outlining methods for trial selection, data extraction, and statistical analysis. A MEDLINE search of the English language literature was performed to identify clinical trials evaluating steroid treatment of IFNP. Three independent observers used an eight-point analysis to determine inclusion criteria. Data analysis was limited to individuals with clinically complete IFNP. The endpoints measured were clinically complete or incomplete facial motor recovery. Effect magnitude and significance were evaluated by calculating the rate difference and Fisher's Exact Test P value. Pooled analysis was performed with a random effects model. Results Forty-seven trials were identified. Of those, 27 were prospective and 20 retrospective. Three prospective trials met the inclusion criteria. Tests of heterogeneity indicate the trial with the smallest sample size (RD = ,0.19; 95% CI, ,0.58,0.20), to be an outlier. It was excluded from the final analysis. Analyses of data from the remaining two studies indicate corticosteroid treatment improves complete facial motor recovery for individuals with complete IFNP. Rate difference demonstrates a 17% (99% CI, 0.01,0.32) improvement in clinically complete recovery for the treatment group based on the random effects model. Conclusions Corticosteroid treatment provides a clinically and statistically significant improvement in recovery of function in complete IFNP. [source]


Effect of anthropogenic low-frequency noise on the foraging ecology of Balaenoptera whales

ANIMAL CONSERVATION, Issue 1 2001
Donald A. Croll
The human contribution to ambient noise in the ocean has increased over the past 50 years, and is dominated by low-frequency (LF) sound (frequencies <1000 Hz) from shipping, oil and gas development, defence-related and research activities. Mysticete whales, including six endangered species, may be at risk from this noise pollution because all species produce and probably perceive low-frequency sound. We conducted a manipulative field experiment to test the effects of loud, LF noise on foraging fin blue (B. musculus) and (Balaenoptera physalus) whales off San Nicolas Island, California. Naive observers used a combination of attached tracking devices, ship-based surveys, aerial surveys, photo-identification and passive monitoring of vocal behaviour to examine the behaviour and distribution of whales when a loud LF source (US Navy SURTASS LFA) was and was not transmitting. During transmission, 12-30% of the estimated received levels of LFA of whales in the study area exceeded 140 dB re 1 ,Pa. However, whales continued to be seen foraging in the region. Overall, whale encounter rates and diving behaviour appeared to be more strongly linked to changes in prey abundance associated with ceanographic parameters than to LF sound transmissions. In some cases, whale vocal behaviour was significantly different between experimental and non-experimental periods. However, these differences were not consistent and did not appear to be related to LF sound transmissions. At the spatial and temporal scales examined, we found no obvious responses of whales to a loud, anthropogenic, LF sound. We suggest that the cumulative effects of anthropogenic LF noise over larger temporal and spatial scales than examined here may be a more important consideration for management agencies. [source]