Monolithic Capillary Column (monolithic + capillary_column)

Distribution by Scientific Domains


Selected Abstracts


Capillary electrochromatography with zwitterionic stationary phase on the lysine-bonded poly(glycidyl methacrylate- co -ethylene dimethacrylate) monolithic capillary column

ELECTROPHORESIS, Issue 12 2006
Xiaoli Dong
Abstract A polymer-based neutral monolithic capillary column was prepared by radical polymerization of glycidyl methacrylate and ethylene dimethacrylate in a 100,,m id fused-silica capillary, and the prepared monolithic column was subsequently modified based on a ring opening reaction of epoxide groups with 1,M,lysine in solution (pH,8.0) at 75°C for 10,h to produce a lysine chemically bonded stationary phases in capillary column. The ring opening reaction conditions were optimized so that the column could generate substantial EOF. Due to the zwitterionic functional groups of the lysine covalently bonded on the polymer monolithic rod, the prepared column can generate cathodic and anodic EOF by varying the pH values of running buffer during CEC separation. EOF reached the maximum of ,2.0×10,8,m2v,1s,1 and 2.6×10,8,m2v,1s,1 with pH of the running buffer of 2.25 and 10, respectively. As a consequence, neutral compounds, ionic solutes such as phenols, aromatic acids, anilines, and basic pharmaceuticals were all successfully separated on the column by CEC. Hydrophobic interaction is responsible for separation of neutral analytes. In addition, the electrostatic and hydrophobic interaction and the electrophoretic migration play a significant role in separation of the ionic or ionizable analytes. [source]


Poly(methacrylic acid-ethylene glycol dimethacrylate) monolith in-tube solid-phase microextraction applied to simultaneous analysis of some amphetamine derivatives in urine by capillary zone electrophoresis

ELECTROPHORESIS, Issue 16 2005
Fang Wei
Abstract A method based on in-tube solid-phase microextraction and capillary zone electrophoresis (CZE) was proposed for simultaneously determining four amphetamines (amphetamine, methamphetamine, 3,4-methylenedioxyamphetamine, and 3,4-methylenedioxymethamphetamine) in urine. A poly(methacrylic acid-ethylene glycol dimethacrylate) monolithic capillary column, which can provide sufficient extraction efficiency, was introduced for the extraction of amphetamines from urine samples. The hydrophobic main chains and acidic pendant groups of the monolithic column make it a superior material for extraction of basic analytes from aqueous matrix. After extraction, the samples were analyzed by CZE. The best separation was achieved using a buffer composed of 0.1,M disodium hydrogen phosphate (adjusted to pH,4.5 with 1,M hydrochloric acid) and 20% methanol v/v, with a temperature and voltage of 25°C and 20,kV, respectively. By applying electrokinetic injection with field-amplified sample stacking, detection limits of 25,34,µg/L were achieved. Excellent method of reproducibility was found over a linear range of 0.1,5,mg/L. Determination of these analytes from abusers' urine sample was also demonstrated. [source]


High-efficiency peptide analysis on monolithic multimode capillary columns: Pressure-assisted capillary electrochromatography/capillary electrophoresis coupled to UV and electrospray ionization-mass spectrometry

ELECTROPHORESIS, Issue 21 2003
Alexander R. Ivanov
Abstract High-efficiency peptide analysis using multimode pressure-assisted capillary electrochromatography/capillary electrophoresis (pCEC/pCE) monolithic polymeric columns and the separation of model peptide mixtures and protein digests by isocratic and gradient elution under an applied electric field with UV and electrospray ionization-mass spectrometry (ESI-MS) detection is demonstrated. Capillary multipurpose columns were prepared in silanized fused-silica capillaries of 50, 75, and 100 ,m inner diameters by thermally induced in situ copolymerization of methacrylic monomers in the presence of n -propanol and formamide as porogens and azobisisobutyronitrile as initiator. N -Ethylbutylamine was used to modify the chromatographic surface of the monolith from neutral to cationic. Monolithic columns were termed as multipurpose or multimode columns because they showed mixed modes of separation mechanisms under different conditions. Anion-exchange separation ability in the liquid chromatography (LC) mode can be determined by the cationic chromatographic surface of the monolith. At acidic pH and high voltage across the column, the monolithic stationary phase provided conditions for predominantly capillary electrophoretic migration of peptides. At basic pH and electric field across the column, enhanced chromatographic retention of peptides on monolithic capillary column made CEC mechanisms of migration responsible for separation. The role of pressure, ionic strength, pH, and organic content of the mobile phase on chromatographic performance was investigated. High efficiencies (exceeding 300,000 plates/m) of the monolithic columns for peptide separations are shown using volatile and nonvolatile, acidic and basic buffers. Good reproducibility and robustness of isocratic and gradient elution pressure-assisted CEC/CE separations were achieved for both UV and ESI-MS detection. Manipulation of the electric field and gradient conditions allowed high-throughput analysis of complex peptide mixtures. A simple design of sheathless electrospray emitter provided effective and robust low dead volume interfacing of monolithic multimode columns with ESI-MS. Gradient elution pressure-assisted mixed-mode separation CE/CEC-ESI-MS mass fingerprinting and data-dependent pCE/pCEC-ESI-MS/MS analysis of a bovine serum albumin (BSA) tryptic digest in less than 5 min yielding high sequence coverage (73%) demonstrated the potential of the method. [source]


Fe3+ immobilized metal affinity chromatography with silica monolithic capillary column for phosphoproteome analysis

PROTEINS: STRUCTURE, FUNCTION AND BIOINFORMATICS, Issue 3 2007
Shun Feng
Abstract Immobilized metal affinity chromatography (IMAC) is a commonly used technique for phosphoproteome analysis due to its high affinity for adsorption of phosphopeptides. Miniaturization of IMAC column is essential for the analysis of a small amount of sample. Nanoscale IMAC column was prepared by chemical modification of silica monolith with iminodiacetic acid (IDA) followed by the immobilization of Fe3+ ion inside the capillary. It was demonstrated that Fe3+ -IDA silica monolithic IMAC capillary column could specifically capture the phosphopeptides from tryptic digest of ,-casein with analysis by MALDI-TOF MS. The silica monolithic IMAC capillary column was manually coupled with nanoflow RPLC/nanospray ESI mass spectrometer (,RPLC,nanoESI MS) for phosphoproteome analysis. The system was validated by analysis of standard phosphoproteins and then it was applied to the analysis of protein phosphorylation in mouse liver lysate. Besides MS/MS spectra, MS/MS/MS spectra were also collected for neutral loss peak. After database search and manual validation with conservative criteria, 29 singly phosphorylated peptides were identified by analyzing a tryptic digest of only 12,,g mouse liver lysate. The results demonstrated that the silica monolithic IMAC capillary column coupled with ,RPLC-nanoESI MS was very suitable for the phosphoproteome analysis of minute sample. [source]


Semi-online nanoflow liquid chromatography/matrix-assisted laser desorption ionization mass spectrometry of synthetic polymers using an octadecylsilyl-modified monolithic silica capillary column

RAPID COMMUNICATIONS IN MASS SPECTROMETRY, Issue 13 2010
Takehiro Watanabe
We have designed a semi-online liquid chromatography/matrix-assisted laser desorption/ionization mass spectrometry (LC/MALDI-MS) system to introduce eluent from a octadecylsilyl (ODS) group modified monolithic silica capillary chromatographic column directly onto a sample plate for MALDI-MS analysis. Our novel semi-online system is useful for rapidly and sensitively examining the performance of a monolithic capillary column. An additional advantage is the small elution volume of a monolithic capillary column, which allows delicate eluents, such as 1,1,1,3,3,3,-hexafluoroisopropyl alcohol (HFIP), to be used to achieve cost-effective analysis. Using the semi-online LC/MALDI-MS system, chromatographic separation of polymers by the monolithic column with different eluents was studied. Separation of poly(methyl methacrylate) and Nylon 6/6 showed that the column functioned via size-exclusion separation when tetrahydrofuran or HFIP eluent was used. On the other hand, the separation behavior of Nylon 11 indicated a reversed-phase mode owing to the interaction of the polymer with the modified ODS group in the column. Using tetrahydrofuran/methanol (1:1, v/v) as the eluent, the LC/MALDI-MS spectra of poly(lactic acid), which contains both linear and cyclic polymer structures, showed that the column could separate the hydrophobic cyclic polymer and elute it out relatively slowly. The monolithic column functions basically via size-exclusion separation; the reversed-phase separation by interaction with the ODS functions may have less influence on column separation. The semi-online monolithic capillary LC/MALDI-MS method we have developed should provide a means of effectively analyzing synthetic polymers. Copyright © 2010 John Wiley & Sons, Ltd. [source]


Macroporous monolithic chiral stationary phases for capillary electrochromatography: New chiral monomer derived from cinchona alkaloid with enhanced enantioselectivity

ELECTROPHORESIS, Issue 17 2003
Michael Lämmerhofer
Abstract A new chiral monomer derived from cinchona alkaloid, namely O -9-(tert -butylcarbamoyl)-11-[2-(methacryloyloxy)ethylthio]-10,11-dihydroquinine 1, was employed for the preparation of enantioselective monolithic capillary columns by an in situ copolymerization with 2-hydroxyethyl methacrylate 2 (HEMA), ethylene dimethacrylate 3 (EDMA) in the presence of cyclohexanol and 1-dodecanol as porogens (UV or thermal initiation of azobisisobutyronitrile (AIBN) as radical initiator). The porous properties and the electrochromatographic behavior of the new chiral monoliths were comparatively evaluated with previously described analogs obtained from O -9-[2-(methacryloyloxy)ethylcarbamoyl]-10,11-dihydroquinidine 4 as chiral monomer. Despite close structural and physicochemical similarities of the both chiral monomers, the pore distribution profiles of the resulting monoliths were shifted typically towards larger pore diameters with the new monomer 1. Once more, it was confirmed that a low cross-linking (10 wt% related to total monomers) and a pore diameter of about 1 ,m in the dry state provides the best electrochromatographic efficiency as a result of lower resistance to mass transfer (smaller C-term contribution to peak broadening) and more homogeneous flow profile (smaller A-term). Most importantly, as expected the new poly(1 - co -HEMA- co -EDMA) monoliths showed enhanced enantioselectivities and in addition faster separations as compared to poly(4 - co -HEMA- co -EDMA) analogs, which represents a significant improvement. Further, the elution order was reversed owing to the pseudoenantiomeric behavior of quinine- and quinidine-derived monomers. Fluorescence-labeled 9-fluorenylmethoxycarbonyl (FMOC), dansyl (DNS), 7-dimethylaminosulfonyl-1,3,2-benzoxadiazol-4-yl (DBD), carbazole-9-carbonyl (CC) amino acids could be separated with resolution values between 2 and 4 (with efficiencies typically between 100,000 and 200,000 plates/m) and fluorescence detection (variable wavelength fluorescence detector in-line with UV) yielding routinely a gain in detection sensitivities up to two orders of magnitude without specific optimization of the conditions with regards to fluorescence efficiency. [source]


Preparation and characterization of polymethacrylate monolithic capillary columns with dual hydrophilic interaction reversed-phase retention mechanism for polar compounds

JOURNAL OF SEPARATION SCIENCE, JSS, Issue 15-16 2009
ķ Urban
Abstract Monolithic columns for capillary hydrophilic interaction liquid chromatography (HILIC) were prepared in fused-silica capillaries by radical co-polymerization of [2-(methacryloyloxy)ethyl]dimethyl-(3-sulfopropyl)ammonium hydroxide and ethylene dimethacrylate in various binary and ternary porogen solvent mixtures with azobisisobutyronitrile as the initiator of the polymerization reaction. Columns showed mixed separation modes: reversed-phase (RP) in water-rich mobile phases and HILIC at high concentrations of acetonitrile (>60,80%) in aqueous,organic mobile phases. A continuous change in retention was observed at increasing concentration of water in acetonitrile, giving rise to characteristic U-turn plots of retention factors versus the concentration of water in the mobile phase, with minima corresponding to the transition between the mechanisms controlling the retention. The selectivity of organic polymer monolithic columns for HILIC separations can be varied by adjusting the concentration of sulfobetaine monomer and the composition of the porogen solvent in the polymerization mixture. Under HILIC conditions, the monolithic capillary sulfobetaine columns show separation selectivities for polar phenolic acids similar to those of a commercial silica-based sulfobetaine ZIC-HILIC column, which, however, has limited selectivity in the RP mode due to lower retention. [source]


Separation of benzene and deuterated benzenes by reversed-phase and recycle liquid chromatography using monolithic capillary columns

JOURNAL OF SEPARATION SCIENCE, JSS, Issue 15-16 2004
Lee Wah Lim
Abstract An alternate pumping-recycle system utilizing a commercially available low dead-volume switching valve was developed for microcolumn LC. The recycle system had two separation columns, and the dead volume of the recycling lines was kept to a minimum by avoiding passage of the sample through the pump chamber, sample injector, and the normal path length of a conventional UV detector. The drawback of the high total back pressure caused by the second column that is placed after the detector was overcome by on-column detection, and this eliminated the need for a high pressure flow cell. The system was used for the separation of an authentic mixture of benzene, benzene-1,3,5-d3, and benzene-d6. Baseline separation was accomplished after six cycles and the calculated theoretical plate number for benzene was 230,000. It was observed that the theoretical plate number (N) increased linearly with increasing number of cycles, and the N per unit time increased with increasing inlet pressure. The separation conditions were optimized and the separation of benzene and benzene-d6 was accomplished within 75 min at 2.5 MPa inlet pressure. [source]