Microtensile Bond Strength (microtensile + bond_strength)

Distribution by Scientific Domains

Terms modified by Microtensile Bond Strength

  • microtensile bond strength test

  • Selected Abstracts


    Microtensile Bond Strength of Luting Materials to Coronal and Root Dentin

    JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, Issue 3 2005
    RICARDO WALTER DDS
    ABSTRACT Purpose:: The purpose of this study was to evaluate the microtensile bond strength (,TBS) of two dual-cured resin cements and a glass ionomer cement to coronal dentin versus root dentin. Materials and Methods: RelyX Unicem (3M ESPE, St. Paul, MN, USA) and Panavia F (Kuraray Medical Inc., Tokyo, Japan) were the resin cements used and FujiCEM (GC Corp., Tokyo, Japan) was the glass ionomer cement used. Once separated, the labial coronal and root surfaces of six bovine incisors were ground with 600-grit SiC papers to expose middle dentin. Then, the dentin surfaces were treated following the manufacturers'instructions and a 1 mm thick layer of each material was applied to the flattened coronal and root surfaces. Each material was cured following the manufacturers'recommendations and a composite buildup was made over the cured luting materials for testing purposes. After 24 hours in water at 37°C, the teeth were sectioned into 1 mm × 1 mm × 6 mm beams and tested for ,TBS. The data were analyzed by one- and two-way analysis of variance and Fisher's Protected Least Squares Differences test (p < .05). Results: The ,TBSs to coronal and root dentin were similar within each cement. Comparing the materials, RelyX Unicem presented the highest ,TBS, followed by Panavia F and FujiCEM, respectively (p < .0001). Conclusions: Although there were differences in ,TBS among the materials tested, no significant differences were found between bond strengths to coronal and root substrates. [source]


    Microtensile Bond Strength and Impact Energy of Fracture of CAD-Veneered Zirconia Restorations

    JOURNAL OF PROSTHODONTICS, Issue 3 2009
    Moustafa N. Aboushelib DDS
    Abstract Purpose: With state-of-the-art CAD/CAM technology, the fabrication of large and complex zirconia frameworks is just a click away. On the other hand, veneering of the frameworks is still operator-dependent. The aim of this work was to evaluate CAD veneering of zirconia restorations in terms of zirconia veneer bond strength and impact energy of fracture in a step towards complete automation of the fabrication process. Materials and Methods: A new CAD/CAM system was used to fabricate a resin replica of the esthetic ceramic required to veneer a zirconia framework. The replica was seated on the zirconia framework and further processed using press-on technology. The bond strength between zirconia and the CAD veneer was evaluated using microtensile bond strength test. The impact energy of fracture of the specimens was also investigated. Manually layered zirconia specimens served as a control (,= 0.05). Results: There was no significant difference in the microtensile bond strength between zirconia and either of the used veneers (39 MPa). Even though the impact energy of fracture of the CAD-veneered and manually layered specimens was almost identical (0.13 J), the former demonstrated a cohesive fracture of the veneer, while the latter failed by delamination of the veneer ceramic. Conclusion: CAD veneering is a reliable method for veneering zirconia restorations. [source]


    Fatigue resistance of dentin/composite interfaces with an additional intermediate elastic layer

    EUROPEAN JOURNAL OF ORAL SCIENCES, Issue 1 2005
    Jan De Munck
    According to the ,elastic bonding' concept, a thick intermediate layer of flexible resin has been suggested to absorb part of the polymerization shrinkage stress and to absorb shocks during function. In this study, the effect of an additional intermediate layer of a low-viscosity resin on the microrotary fatigue resistance (µRFR) of a hybrid composite bonded to dentin was evaluated. The hypotheses tested were that an intermediate layer of a low-viscosity resin (i) increases the µRFR to dentin, but (ii) has no effect on the static bond strength. Microtensile bond strength (µTBS) samples were loaded until failure or inserted in a microrotary fatigue testing device. Specimens were tested at 4 Hz until failure or until 105 cycles were reached. An additional intermediate elastic layer had no effect on the static µTBS, but significantly lowered the median µRFR from 28.4 MPa to 21.6 MPa. However, the application of an intermediate flexible layer had, no effect on the static µTBS. In conclusion, an additional elastic intermediate layer did decrease significantly the µRFR (rejection of hypothesis i), but did not alter the µTBS (acceptance of hypothesis ii). The decrease in µRFR most likely may be explained by the lower mechanical properties of the intermediary layer. [source]


    Microtensile bond strength of different adhesive systems in dentin irradiated with Er:YAG laser

    LASER PHYSICS LETTERS, Issue 7 2008
    L.M.G. Sierpinsky
    Abstract The objective this study was to evaluate in vitro the bond strength of two etch-and-rise and one self-etching adhesive system after dentin irradiation with Er:YAG (erbium: yttrium aluminum garnet) laser using microtensile test. The results revealed that the groups treated with laser Er:YAG presented less tensile bond strength, independently to the adhesive system used. The prompt L-pop adhesive presented less microtensile bond strength compared to the other adhesives evaluated. There was no difference between single bond and excite groups. The adhesive failures were predominant in all the experimental groups. The Er:YAG laser influenced negatively bond strength values of adhesive systems tested in dental substrate. (© 2008 by Astro Ltd., Published exclusively by WILEY-VCH Verlag GmbH & Co. KGaA) [source]


    Effect of bleaching agents on bonding to pulp chamber dentine

    INTERNATIONAL ENDODONTIC JOURNAL, Issue 4 2005
    S. Timpawat
    Abstract Aim, To determine the effect of intracoronal bleaching agents on adhesion of bonding agents to pulp chamber dentine. Methodology, Forty extracted human maxillary anterior teeth were randomly divided into four groups of 10 teeth each. Bleaching agents were sealed in pulp chambers for 7 days, as in clinical use. Group 1 (control): distilled water, group 2: 35% hydrogen peroxide, group 3: sodium perborate mixed with water, and group 4: sodium perborate mixed with 35% hydrogen peroxide. Teeth were stored in saline at 37 °C for 7 days. After the bleaching agent was removed, teeth were leached in water for a further 7 days prior to bonding. The crown was cut vertically from mesial to distal and the labial pulp chamber dentine was prepared for bonding with Clearfil SE-Bond and filled with resin composite (Clearfil AP-X). The bonded specimens were kept moist at 37 °C for 24 h. Microtensile bond strengths were determined using a universal testing machine. Additional teeth were prepared using the same bleaching procedures to investigate the scanning electron microscopic appearance of the dentine surface. Results, Mean values (±SD) of microtensile bond strength for the experimental groups were: group 1: 5.29 ± 2.21 MPa, group 2: 5.99 ± 1.51 MPa, group 3: 9.17 ± 1.65 MPa and group 4: 3.99 ± 1.31 MPa. Dentine treated with sodium perborate in water (group 3) had significantly higher mean bond strength when compared with the other three groups (P < 0.05, Tukey's test). Mean bond strength was lowest when dentine was treated with sodium perborate plus hydrogen peroxide (group 4). Conclusions, In terms of subsequent bond strength during restoration, sodium perborate mixed with distilled water appears to be the best intracoronal bleaching agent. [source]


    Effect of oxygen inhibition on composite repair strength over time

    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, Issue 2 2007
    Susanna Dall'Oca
    Abstract The study was aimed at examining whether an oxygen inhibition layer is required for bonding a repairing to a pre-existing composite, and to determine the time required for free radicals within a composite substrate to decay to the extent that the composite repair strength drops significantly. Ten slabs of Gradia Direct Anterior (GC Corp.) were divided into (1) control group: an interfacial oxygen inhibition layer was created by applying and light-curing two layers of bonding resin (D/E Resin, Bisco) to the slabs surface in atmospheric air; (2) experimental group: the absence of an interfacial oxygen inhibition layer was obtained by light-curing the second bonding resin layer in a nitrogen atmosphere. After 1 and 2 h, 1, 14, and 30 days of air storage, a composite repair was layered over the bonding resin. Microtensile bond strengths were measured and statistically analyzed. The curing atmosphere was not a significant factor for bond strength (p = 0.82), and time and curing atmosphere-time interaction were significant (p < 0.001). The 30 day-strengths were the lowest (p < 0.05). An oxygen-inhibited layer is not initially required for bonding to resin composite, and it takes more than 14 days before the bond strength between a pre-existing and a fresh composite drops. © 2006 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2006 [source]


    Role of preliminary etching for one-step self-etch adhesives

    EUROPEAN JOURNAL OF ORAL SCIENCES, Issue 5 2010
    Michael Taschner
    Taschner M, Nato F, Mazzoni A, Frankenberger R, Krämer N, Di Lenarda R, Petschelt A, Breschi L. Role of preliminary etching for one-step self-etch adhesives. Eur J Oral Sci 2010; 118: 517,524. © 2010 Eur J Oral Sci The aim of this study was to analyse the effect of preliminary phosphoric acid etching of enamel and dentine before the application of two, one-step self-etch adhesive systems. The systems were applied onto acid-etched or smear-layer-covered enamel and dentine. The treatment groups were as follows: group 1, Adper Easy Bond (3M ESPE) on etched substrate; group 2, Adper Easy Bond (control); group 3, iBond Self-Etch (Heraeus Kulzer) on etched substrate; and group 4, iBond Self-Etch (control). Enamel and dentine bond strengths were calculated using microshear and microtensile bond-strength tests. Additional specimens were prepared to evaluate nanoleakage at the dentine,adhesive interface and were investigated using light microscopy or transmission electron microscopy. Both adhesives demonstrated higher microshear bond strengths when enamel was pre-acid-etched with phosphoric acid (Adper Easy Bond 28.7 ± 4.8 MPa; iBond Self-Etch 19.7 ± 3.6 MPa) compared with controls (Adper Easy Bond 19.2 ± 3.3 MPa; iBond Self-Etch 17.5 ± 2.7 MPa) and increased microtensile bond strength when applied on acid-etched (Adper Easy Bond 35.8 ± 5.7 MPa; iBond Self-Etch 24.3 ± 7.9 MPa) vs. smear-layer-covered dentine (Adper Easy Bond 26.9 ± 6.2 MPa; iBond Self-Etch 17.6 ± 4.3 MPa). Adper Easy Bond showed lower nanoleakage than iBond Self-Etch, irrespective of preliminary etching. The results of this study support the use of phosphoric acid etching before the application of one-step self-etch adhesive systems. [source]


    Effects of additional and extended acid etching on bonding to caries-affected dentine

    EUROPEAN JOURNAL OF ORAL SCIENCES, Issue 5 2004
    César Augusto Galvćo Arrais
    This study evaluated the effects of additional and extended acid etching on microtensile bond strength (µTBS) of two adhesive systems to sound (SD) and caries-affected dentine (CAD). Flat surfaces of CAD surrounded by SD of 36 extracted carious third molars were assigned to four treatments (i): self-etching adhesive system (Clearfil SE Bond) applied to dentine surfaces following manufacturer's instructions (MI); (ii) after additional etching for 15 s (35% phosphoric acid, PA); (iii) total-etch one-bottle adhesive (Single Bond) applied to dentine surfaces following MI; or (iv), after etching for 45 s with PA. Composite ,blocks' were built on bonded surfaces and restored teeth were vertically sectioned to obtain bonded slices of 0.7 mm thick. Slices were trimmed to create hourglass-shaped specimens (cross-sectional area of 1 mm2), which were tested under tension in a universal testing machine. Additional CAD and SD samples were prepared for scanning electron microscopy observations. Additional and extended etching significantly increased µTBS to CAD; however, µTBS of both adhesives to CAD were significantly lower than to SD. Additional and extended etching can improve bonding to CAD; however, adhesives applied on SD showed the best results for bonding. [source]


    Comparison of bonding efficacy of an all-in-one adhesive with a self-etching primer system

    EUROPEAN JOURNAL OF ORAL SCIENCES, Issue 3 2004
    Tomoko Abo
    The aim of this study was to compare the bonding efficacy of an all-in-one adhesive with that of a self-etching primer system by measuring microleakage after thermocycling and the microtensile bond strength (,TBS) to enamel and dentin. Circular class V cavities along cement,enamel junctions were prepared in 20 extracted human premolars. Each 10 teeth were bonded with either AD Bond (AD) or Clearfil SE Bond (SE), and filled with a resin composite (Charisma). After thermocycling and staining with 0.5% basic fuchsin, the microleakage at the coronal and apical walls was evaluated using longitudinal sections. In addition 20 premolars were used to measure ,TBS at 24 h after bonding for these adhesives to enamel and dentin that corresponded to the coronal and apical walls of the class V cavities. AD showed more microleakage than SE in the coronal walls, but there was less microleakage in the apical walls and no difference in apical leakage between the two adhesives. ,TBS (SD) in MPa to enamel and dentin were 25.2 (7.3) and 68.3 (9.4) for AD, and 35.8 (7.4) and 76.4 (7.8) for SE, respectively. AD gave a lower ,TBS to enamel than did SE. The results suggested that the poor adaptation at the coronal wall in AD might be caused by the lower bond strength to enamel. [source]


    Effect of bleaching agents on bonding to pulp chamber dentine

    INTERNATIONAL ENDODONTIC JOURNAL, Issue 4 2005
    S. Timpawat
    Abstract Aim, To determine the effect of intracoronal bleaching agents on adhesion of bonding agents to pulp chamber dentine. Methodology, Forty extracted human maxillary anterior teeth were randomly divided into four groups of 10 teeth each. Bleaching agents were sealed in pulp chambers for 7 days, as in clinical use. Group 1 (control): distilled water, group 2: 35% hydrogen peroxide, group 3: sodium perborate mixed with water, and group 4: sodium perborate mixed with 35% hydrogen peroxide. Teeth were stored in saline at 37 °C for 7 days. After the bleaching agent was removed, teeth were leached in water for a further 7 days prior to bonding. The crown was cut vertically from mesial to distal and the labial pulp chamber dentine was prepared for bonding with Clearfil SE-Bond and filled with resin composite (Clearfil AP-X). The bonded specimens were kept moist at 37 °C for 24 h. Microtensile bond strengths were determined using a universal testing machine. Additional teeth were prepared using the same bleaching procedures to investigate the scanning electron microscopic appearance of the dentine surface. Results, Mean values (±SD) of microtensile bond strength for the experimental groups were: group 1: 5.29 ± 2.21 MPa, group 2: 5.99 ± 1.51 MPa, group 3: 9.17 ± 1.65 MPa and group 4: 3.99 ± 1.31 MPa. Dentine treated with sodium perborate in water (group 3) had significantly higher mean bond strength when compared with the other three groups (P < 0.05, Tukey's test). Mean bond strength was lowest when dentine was treated with sodium perborate plus hydrogen peroxide (group 4). Conclusions, In terms of subsequent bond strength during restoration, sodium perborate mixed with distilled water appears to be the best intracoronal bleaching agent. [source]


    Adhesion of a self-etching system to dental substrate prepared by Er:YAG laser or air abrasion

    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, Issue 2 2008
    Wanessa C. Souza-Zaroni
    Abstract The purpose of this study was to assess the microtensile bond strength of a self-etching adhesive system to enamel and dentin prepared by Er:YAG laser irradiation or air abrasion, as well as to evaluate the adhesive interfaces by scanning electron microscopy (SEM). For microtensile bond strength test, 80 third molars were randomly assigned to five groups: Group I, carbide bur, control (CB); II, air abrasion with standard tip (ST); III, air abrasion with supersonic tip (SP); IV, Er:YAG laser 250 mJ/4 Hz (L250); V, Er:YAG laser 300 mJ/4 Hz (L300). Each group was divided into two subgroups (n = 8) (enamel, E and dentin, D). E and D surfaces were treated with the self-etching system Adper Prompt L-Pop and composite buildups were done with Filtek Z-250. Sticks with a cross-sectional area of 0.8 mm2 (±0.2 mm2) were obtained and the bond strength tests were performed. Data were submitted to ANOVA and Tukey's test. For morphological analysis, disks of 30 third molars were restored, sectioned and prepared for SEM. Dentin presented the highest values of adhesion, differing from enamel. Laser and air-abrasion preparations were similar to enamel. Dentin air-abrasion with standard tip group showed higher bond strength results than Er:YAG-laser groups, however, air-abrasion and Er:YAG laser groups were similar to control group. SEM micrographs revealed that, for both enamel and dentin, the air-abrasion and laser preparations presented irregular adhesive interfaces, different from the ones prepared by rotary instrument. It was concluded that cavity preparations accomplished by both Er:YAG laser energies and air abrasion tips did not positively influence the adhesion to enamel and dentin. © 2007 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2008 [source]


    Effects of a peripheral enamel bond on the long-term effectiveness of dentin bonding agents exposed to water in vitro

    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, Issue 1 2008
    Andre F. Reis
    Abstract This study evaluated the effects of water exposure on the in vitro microtensile bond strength (,TBS) of etch-and-rinse and self-etching adhesives to human dentin over a 1-year storage period. Five adhesive systems used were as follows: a one-step self-etching adhesive (One-up Bond F-OB), two two-step self-etching primers (Clearfil SE Bond-SE and Clearfil Protect Bond-CP), and two etch-and-rinse adhesives (Single Bond-SB and Prime&Bond NT-PB). Dentin surfaces were bonded, restored, and assigned to four subgroups, according to the degree of water exposure: 24 h of peripheral water exposure (24 h-PE) (having circumferential enamel); and 1 year of peripheral exposure (1 yr-PE), direct exposure (1 yr-DE) (dentin directly water-exposed), or directly exposed to oil only (no water exposure) (1 yr-DOE). A composite-enamel bond adjacent to the restoration is determined if the water exposure was peripheral or direct. After storage periods, specimens were serially sectioned, trimmed to an hourglass shape with a cross-sectional area of 1 mm2 at the interface, and tested in tension. Results were analyzed by two-way ANOVA and Tukey test (, = 0.05). No difference was found between 24 h-PE and 1 yr-PE for OB, CP, SB, and PB. However, ,TBS values significantly dropped after 1 yr-DE for SE, CP, SB, and PB. A decreased ,TBS was seen in SE after 1 yr-PE, but no differences existed between 1 yr-PE and 1 yr-DE. Similar or increased ,TBS values were noted in 1 yr-DOE for all adhesives. Water-storage for 1 year significantly decreased ,TBS for all adhesives. However, except for SE, the presence of a peripheral composite-enamel bond seemed to reduce the degradation rate in resin-dentin interfaces for all materials. © 2007 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2008 [source]


    Bonding characteristics of newly developed all-in-one adhesives

    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, Issue 2 2007
    S. K. Sidhu
    Abstract This study evaluated the microtensile bond strength and the interfacial morphology of newer adhesives. The occlusal surfaces of extracted teeth were ground flat for random allocation to four equal groups. Resin composite was bonded to each surface using either Clearfil SE Bond [SEB], Clearfil Protect Bond [PB], G-Bond [GB], or an experimental adhesive, SSB-200 [SSB]. After storage for 24 h in water at 37°C, they were sectioned into beams (cross-sectional area 1 mm2) for microtensile bond strength testing (,TBS) at a crosshead speed of 1 mm/min. The load at failure of each was recorded; the data were analyzed by one-way ANOVA and Games Howell tests. The surfaces of the fractured specimens were observed using SEM. For the ultra-morphology of the interface, the occlusal surfaces of four more teeth were prepared as before and a thin layer of flowable resin composite was bonded to each surface using one of the four adhesives. The mean ,TBS ranged from 39.68 MPa (GB) to 64.97 MPa (SEB). There were no statistical differences between SEB and SSB, or between PB and GB (p > 0.05). The ,TBS of SEB and SSB were significantly greater than that of PB and GB (p < 0.05). SEMs of the fractured surfaces revealed a mixed (cohesive/interfacial) failure. TEM examination highlighted differences in the hybrid layer; SEB had a thicker layer than the others. In conclusion, the newer all-in-one adhesives produced a thin hybrid layer but varied in their bond strengths. The 2-step self-etching adhesives do not necessarily produce higher bond strengths than that of the all-in-one systems. © 2006 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2007 [source]


    Effects of adhesive systems and luting agents on bonding of fiber posts to root canal dentin

    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, Issue 1 2006
    Francesca Monticelli
    Abstract The study evaluated the influence of different luting materials on the microtensile bond strength of glass fiber posts to root canal dentin. Thirty extracted maxillary premolars were endodontically treated, and the roots were prepared for post cementation using the FRC Postec system (Vivadent). Two luting materials (Multilink, Vivadent and Clearfil Photo Core, Kuraray) were used in combination with three adhesive: Multilink Primer (Vivadent), Clearfil Photo Bond, and Clearfil New Bond (Kuraray). A composite build-up was performed around the root to provide adequate gripping during testing. Specimens were cut to obtain beams with the post in the center and with the radicular dentin overlaid by the composite build-up on each side. Microtensile testing was performed with a universal testing machine at a cross-head speed of 0.5 mm/min. The failure mode was classified under a stereomicroscope and four representative beams of each group were selected for SEM analysis. Bond strength data that were analyzed with two-way ANOVA and Student-Newman-Keuls multiple comparisons tests revealed that adhesive systems, luting materials, and the interaction between these two factors significantly influenced the bond strength results (p < 0.01). Multilink applied with its own adhesive system obtained the best results, while the lowest bond strength was achieved with clearfil photo core in combination with multilink primer. © 2005 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2006 [source]


    Bond Strength of Two Resin Cements on Dentin Using Different Cementation Strategies

    JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, Issue 4 2010
    RENATA MARQUES MELO MS
    ABSTRACT Purpose:, This study evaluated the microtensile bond strength of two resin cements to dentin either with their corresponding self-etching adhesives or employing the three-step "etch-and-rinse" technique. The null hypothesis was that the "etch-and-rinse" adhesive system would generate higher bond strengths than the self-etching adhesives. Materials and Methods:, Thirty-two human molars were randomly divided into four groups (N = 32, n = 8/per group): G1) ED Primer self-etching adhesive + Panavia F; G2) All-Bond 2 "etch-and-rinse" adhesive + Panavia F; G3) Multilink primer A/B self-etching adhesive + Multilink resin cement; G4) All-Bond 2 + Multilink. After cementation of composite resin blocks (5 × 5 × 4 mm), the specimens were stored in water (37°C, 24 hours), and sectioned to obtain beams (±1 mm2 of adhesive area) to be submitted to microtensile test. The data were analyzed using 2-way analysis of variance and Tukey's test (, = 0.05). Results:, Although the cement type did not significantly affect the results (p = 0.35), a significant effect of the adhesive system (p = 0.0001) was found on the bond strength results. Interaction terms were not significant (p = 0.88751). The "etch-and-rinse" adhesive provided significantly higher bond strength values (MPa) with both resin cements (G2: 34.4 ± 10.6; G4: 33.0 ± 8.9) compared to the self-etching adhesive systems (G1: 19.8 ± 6.6; G3: 17.8 ± 7.2) (p < 0.0001). Pretest failures were more frequent in the groups where self-etching systems were used. Conclusion:, Although the cement type did not affect the results, there was a significant effect of changing the bonding strategy. The use of the three-step "etch-and-rinse" adhesive resulted in significantly higher bond strength for both resin cements on dentin. CLINICAL SIGNIFICANCE Dual polymerized resin cements tested could deliver higher bond strength to dentin in combination with "etch-and-rinse" adhesive systems as opposed to their use in combination with self-etching adhesives. (J Esthet Restor Dent 22:262,269, 2010) [source]


    Direct Dentin Bonding Technique Sensitivity When Using Air/Suction Drying Steps

    JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, Issue 2 2008
    PASCAL MAGNE DMD
    ABSTRACT Statement of Problem:, Moisture control before and after application of the primer/adhesive components of etch-and-rinse dentin bonding agents is usually achieved using a stream of air delivered by an air syringe. Suction drying with a suction tip is a common alternative for moisture control, but data about the use of suction drying instead of the air syringe is scarce or nonexistent. Purpose:, The purpose of this study was to compare the dentin microtensile bond strength (MTBS) using either the air syringe or the suction tip to control the amount of moisture. Materials and Methods:, Fifteen freshly extracted human molars were divided randomly into three groups of five. A three-step etch-and-rinse dentin bonding agent (OptiBond FL) was used. Group 1 was the control group and utilized air drying alone (with an air syringe) during the placement of the dentin adhesive on the ground-flat occlusal dentin surface. Group 2 also used air drying alone, but teeth were prepared with a standardized MOD cavity. Group 3 utilized suction drying alone in the standardized MOD cavity. All teeth were restored with 1.5-mm-thick horizontal increments of composite resin (Filtek Z100). Specimens were stored in water for 24 hours, then prepared for a nontrimming MTBS test. Bond strength data were analyzed with a Kruskal,Wallis test at p < 0.05. Specimens were also evaluated for mode of fracture and interface characterization using scanning electron microscope (SEM) analysis. Results:, The mean MTBSs were not statistically different from one another (p = 0.54) at 54.0 MPa (air-drying, flat dentin), 53.4 MPa (air-drying, MOD), and 49.2 MPa (suction drying, MOD). Microscopic evaluation of failure modes indicated that most failures were interfacial. Failed interfaces, when analyzed under SEM, appeared typically mixed with areas of failed adhesive resin and areas of cohesively failed dentin. Conclusions:, There are no differences in MTBS to human dentin using either the air syringe or the suction tip to control the amount of moisture. The conventional three-step dentin bonding agent used in the present study not only proved insensitive to the moisture-control method but also to the effect of increased polymerization shrinkage stress (ground-flat versus MOD preparation). CLINICAL SIGNIFICANCE Although the effect of common errors on the performance of total-etch adhesives has been investigated, data about the use of suction drying instead of an air syringe is scarce or nonexistent. The present study demonstrated that both the air syringe and the suction tip can be used to control moisture when using etch-and-rinse dentin bonding agents. The conventional three-step dentin bonding agent tested, OptiBond FL, demonstrated low technique sensitivity. [source]


    Microtensile Bond Strength of Luting Materials to Coronal and Root Dentin

    JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, Issue 3 2005
    RICARDO WALTER DDS
    ABSTRACT Purpose:: The purpose of this study was to evaluate the microtensile bond strength (,TBS) of two dual-cured resin cements and a glass ionomer cement to coronal dentin versus root dentin. Materials and Methods: RelyX Unicem (3M ESPE, St. Paul, MN, USA) and Panavia F (Kuraray Medical Inc., Tokyo, Japan) were the resin cements used and FujiCEM (GC Corp., Tokyo, Japan) was the glass ionomer cement used. Once separated, the labial coronal and root surfaces of six bovine incisors were ground with 600-grit SiC papers to expose middle dentin. Then, the dentin surfaces were treated following the manufacturers'instructions and a 1 mm thick layer of each material was applied to the flattened coronal and root surfaces. Each material was cured following the manufacturers'recommendations and a composite buildup was made over the cured luting materials for testing purposes. After 24 hours in water at 37°C, the teeth were sectioned into 1 mm × 1 mm × 6 mm beams and tested for ,TBS. The data were analyzed by one- and two-way analysis of variance and Fisher's Protected Least Squares Differences test (p < .05). Results: The ,TBSs to coronal and root dentin were similar within each cement. Comparing the materials, RelyX Unicem presented the highest ,TBS, followed by Panavia F and FujiCEM, respectively (p < .0001). Conclusions: Although there were differences in ,TBS among the materials tested, no significant differences were found between bond strengths to coronal and root substrates. [source]


    OXYGEN-INHIBITED LAYER IN ADHESION DENTISTRY

    JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, Issue 5 2004
    Byoung I. Suh MS
    ABSTRACT Purpose:: Characteristics of the oxygen-inhibited layer, including bond strength, photoinitiator decomposition, and post-curing degree of conversion, were investigated. Materials and Methods: To investigate shear bond strength, BisCover (Bisco, Inc., Schaumburg, IL, USA) and D/E Resin (Bisco, Inc.) were placed on disks of Renew composite (Bisco, Inc.) and cured both with and without an oxygen-inhibited layer. Light-Bond composite (Reliance Orthodontic, Itasca, IL, USA) was placed in a gelatin capsule and light cured over the cured resin. After soaking in water for 2 hours at 37°C, specimens were sheared to failure using a universal testing machine (Model 4466, Instron Inc., Canton, MA, USA). To investigate microtensile bond strength, composite substrates prepared using Renew A2 composite were light cured either in air or under nitrogen. Light-Core (Bisco, Inc.) was placed on each substrate and light cured. The resulting specimens were sectioned into composite beams and stressed to failure using a microtensile tester (built by Bisco, Inc.). To determine camphorquinone (CQ) decomposition, an experimental CQ resin was placed between two glass plates and irradiated for different time intervals. The absorption spectrum was obtained using a Cary 50 Bio UV-Visible Spectrometer (Varian, Mulgrave, Australia). To explore the degree of conversion, polyester film strips (Mylar, DuPont, Wilmington, DE, USA) coated with the CQ resin were pre-cured in air for different time periods, and then post-cured at low intensity for 5 minutes under nitrogen. A Spectrum 1000FTIR Spectrometer (Perkin Elmer, Norwalk, CT, USA) was used to measure the degree of conversion. Results: Bond strength tests resulted in no significant difference between samples with or without an oxygen-inhibited layer. The oxygen-inhibited layer contained reduced amounts of photoinitiator. The degree of conversion of post-cured oxygen-inhibited layers was lower than that for the control. Conclusion: An oxygen-inhibited layer is not necessary for bonding with composite resin. [source]


    Microtensile Bond Strength and Impact Energy of Fracture of CAD-Veneered Zirconia Restorations

    JOURNAL OF PROSTHODONTICS, Issue 3 2009
    Moustafa N. Aboushelib DDS
    Abstract Purpose: With state-of-the-art CAD/CAM technology, the fabrication of large and complex zirconia frameworks is just a click away. On the other hand, veneering of the frameworks is still operator-dependent. The aim of this work was to evaluate CAD veneering of zirconia restorations in terms of zirconia veneer bond strength and impact energy of fracture in a step towards complete automation of the fabrication process. Materials and Methods: A new CAD/CAM system was used to fabricate a resin replica of the esthetic ceramic required to veneer a zirconia framework. The replica was seated on the zirconia framework and further processed using press-on technology. The bond strength between zirconia and the CAD veneer was evaluated using microtensile bond strength test. The impact energy of fracture of the specimens was also investigated. Manually layered zirconia specimens served as a control (,= 0.05). Results: There was no significant difference in the microtensile bond strength between zirconia and either of the used veneers (39 MPa). Even though the impact energy of fracture of the CAD-veneered and manually layered specimens was almost identical (0.13 J), the former demonstrated a cohesive fracture of the veneer, while the latter failed by delamination of the veneer ceramic. Conclusion: CAD veneering is a reliable method for veneering zirconia restorations. [source]


    Microtensile bond strength of different adhesive systems in dentin irradiated with Er:YAG laser

    LASER PHYSICS LETTERS, Issue 7 2008
    L.M.G. Sierpinsky
    Abstract The objective this study was to evaluate in vitro the bond strength of two etch-and-rise and one self-etching adhesive system after dentin irradiation with Er:YAG (erbium: yttrium aluminum garnet) laser using microtensile test. The results revealed that the groups treated with laser Er:YAG presented less tensile bond strength, independently to the adhesive system used. The prompt L-pop adhesive presented less microtensile bond strength compared to the other adhesives evaluated. There was no difference between single bond and excite groups. The adhesive failures were predominant in all the experimental groups. The Er:YAG laser influenced negatively bond strength values of adhesive systems tested in dental substrate. (© 2008 by Astro Ltd., Published exclusively by WILEY-VCH Verlag GmbH & Co. KGaA) [source]