Mitral Valve (mitral + valve)

Distribution by Scientific Domains

Terms modified by Mitral Valve

  • mitral valve area
  • mitral valve disease
  • mitral valve leaflet
  • mitral valve prolapse
  • mitral valve regurgitation
  • mitral valve repair
  • mitral valve replacement
  • mitral valve surgery

  • Selected Abstracts


    EFFECT OF PARAPROSTHETIC MODERETE TO SEVERE MITRAL REGURGITATION ON EMBOLIC EVENTS IN PATIENTS WITH PROSTHETIC MITRAL VALVES

    ECHOCARDIOGRAPHY, Issue 5 2004
    C. Cevik
    Thromboembolism is the major chronic risk for patients with mechanical prosthetic heart valves. Although optimal oral anticoagulantion is the key determinant for embolic events (EE) in these patients; other factors also contribute to this complication. We studied the prevalence and determinants of embolic events in patients with mitral prosthetic heart valves undergoing transesophageal echocardiography (TEE). 210 patients (86 male and 124 female, mean age 45.1 +/, 9.6 years) underwent a TEE study for evaluation of prosthetic valve functions. Clinical and TEE findings of the patients were as follows: Atrial fibrillation in 132 (%62) patients, prosthetic valve thrombus in 55 (%26) suboptimal INR (INR < 1.8) in 61 (%29) pts, left atrial spontenous echocardiographic contrast (SEC) in 31 (%14) patients, paraprosthetic moderete-severe mitral regurgitation (MR) in 28 (%13), left atrial (LA) and/or left atrial appendix (LAA) thrombus in 41 (%19), LA and/or LAA outflow velocities <0.25 m/sn in 21 patiens (%10), left atrial diameter >6 cm in 47 (%22). 72 patients had a history of EE in the previous 6 months (%34). In no patients were there any EE in the presence of paraprosthetic moderate to severe MR. Both with univariate and multivariate analysis presence of prosthetic valve and LA and/or LAA thrombus, absence of paraprosthetic moderete-severe MR, suboptimal INR, atrial fibrillation were found to be independent predictors for embolic events. Conclusions: Although the presence of prosthetic valve and LA and/or LAA thrombus, suboptimal INR, and AF predict EE, clinical and echocardiographic data support the protective effect of paraprosthetic moderate to severe MR against EE in pts with mitral prosthetic valves. [source]


    Depicting of a Cleft Mitral Valve by Real Time Three-Dimensional Transesophageal Echocardiography

    ECHOCARDIOGRAPHY, Issue 3 2010
    F.E.S.C., Mehmet Özkan M.D.
    We report the usefulness of real time three-dimensional transesophageal echocardiography in comprehensive delineation of cleft mitral valve. This new technique may be a useful supplement to two-dimensional and three-dimensional transthoracic echocardiography in the assessment of this pathology. (Echocardiography 2010;27:356-358) [source]


    Lesions of the Mitral Valve as a Cause of Central Retinal Artery Occlusion: Presentation and Discussion of Two Cases

    ECHOCARDIOGRAPHY, Issue 1 2010
    Maryam Ayati M.D.
    We present two cases of mitral valve lesions that manifested with unilateral blindness caused by central retinal artery occlusion (CRAO): Case 1. A 68-year-old woman was admitted to our clinic for sudden blindness. Retinal artery angiogram showed CRAO. Transthoracic and transesophageal echocardiography (TEE) documented a mass attached to the ventricular side of the posterior mitral leaflet, which at pathology was identified as a blood cyst. Case 2. A 67-year-old man was admitted for a sudden unilateral painless loss of vision. Retinal angiogram documented CRAO, and TEE showed a highly mobile, spherical, lesion on the atrial side of anterior mitral leaflet. In this case, the pathological finding was a degenerated calcified thrombosis. We report on two cases of very rare abnormalities of the mitral valve presenting with a very rare embolic complication, i.e., CRAO. Like for cryptogenic stroke, transesophageal echocardiography plays a central role in the diagnosis of cardiogenic embolic sources. (Echocardiography 2010;27:E1-E3) [source]


    Paraprosthetic Leak Unmasked by Combined Enoxaparin/Warfarin Therapy for Thrombosed Mitral Valve

    ECHOCARDIOGRAPHY, Issue 9 2009
    John Barbetseas M.D.
    No abstract is available for this article. [source]


    Reference Values Describing the Normal Mitral Valve and the Position of the Papillary Muscles

    ECHOCARDIOGRAPHY, Issue 7 2007
    Petrus Nordblom M.Sc.
    In patients with functional mitral regurgitation (MR), the principal mechanisms are insufficient coaptation due to dilatation of the mitral annulus (MA), global ventricular dysfunction with tethering of leaflets, or restricted leaflet motion with incorrect apposition due to regional ventricular dysfunction and displacement of the papillary muscles (PMs). These different entities often coexist and for this reason, knowledge of the normal reference values describing the shape and size of the MA and the position of the PMs is essential. In the present study, we describe the MA dimensions and the position of the PMs in a group of normal individuals (n = 38, 60% women, age [mean ± SD] 51 ± 9 years and BSA 1.83 ± 0.16 m2) investigated with transthoracic echocardiography. The anteroposterior dimension (AP) of the ellipse-shaped MA was measured in a parasternal long axis, while the distance from the posteromedial (PoM) to the anterolateral (AL) commissure was measured in a parasternal short axis (CC). The annular area was calculated assuming elliptic geometry. The MA shape was described by the ratios AP/CC and AP/length of the anterior leaflet. The PMs' position was described by the following distances: (a) from the MA to the tip of the PoM and AL, PMs measured in a modified two-chamber view where both PMs could be identified, (b) the interpapillary distance, and (c) the tethering distance from the tip of the PM to the contralateral MA. These data on the normal mitral valve morphology should provide useful information when assessing the underlying mechanism of functional MR. [source]


    Assessment of the Tilting Properties of the Human Mitral Valve during Three Main Phases of the Heart Cycle: An Echocardiographic Study

    ECHOCARDIOGRAPHY, Issue 4 2006
    Daniel Vanhercke B.N., N.F.E.S.C., R.D.C.S.
    Rationale and Objectives: In experimental models of the left heart, the mitral valve (MV) is commonly implanted perpendicular to a central axis of the apex/MV. To adapt this to a more correct anatomical model, as well as for further studies of the left ventricle, we created a database of implantation angles of the MV and annulus during three main phases of the heart cycle, based on standard cardiac ultrasound measurements. Materials and Methods: Twenty-eight patients were studied with the standard cardiac ultrasound equipment. From the apical echo window, an anteroposterior (AP) plane and a perpendicular commisure-commisure (CC) plane were generated during three critical moments in the heart cycle: systole (S); diastole early filling (E); and diastole late filling (A). In both planes, the angles between the annular plane and each mitral leaflet, as well as the angle between a theoretical longitudinal axis through the apex and center of the MV orifice and the mitral annulus plane, were measured with a custom-made application of Matlab R14. Results: We observed an inclination of the angle mitral annulus/central left ventricle axis, with its lowest point in the direction of the aortic valve (AP plane) of 85°± 7° in systole (S), 88°± 8° in early diastole (E), and 88°± 7° in late diastole (A). In the CC plane, we observed an almost horizontal implantation of 91°± 5° in systole (S), 91°± 8° in early diastole (E), and 91°± 7° in late diastole (A). [source]


    Laser Doppler Velocimetry and Flow Visualization Studies in the Regurgitant Leakage Flow Region of Three Mechanical Mitral Valves

    ARTIFICIAL ORGANS, Issue 4 2001
    Richard S. Meyer
    Abstract: Streak line flow visualization and laser Doppler velocimetry (LDV) were conducted in the regurgitant leakage flow region of 3 mechanical heart valve types: CarboMedics, Medtronic Hall, and St. Jude Medical. Streak line flow visualization identified regions of high regurgitant flow, and LDV measurements were focused on those locations. Maximum regurgitant flow velocities after valve closure ranged from 0.7 to 2.6 m/s, and maximum Reynolds shear stress after valve closure ranged from 450 to 3,600 dyne/cm2. These data indicate that leakage flows can generate turbulent jets with elevated Reynolds stresses even in bileaflet valves. [source]


    Percutaneous Mitral Valve Repair for Mitral Regurgitation

    JOURNAL OF INTERVENTIONAL CARDIOLOGY, Issue 1 2003
    PETER C. BLOCK M.D.
    Mitral regurgitation (MR) associated with, ischemic, and degenerative (prolapse) disease, contributes to left ventricular (LV) dysfunction due to remodeling, and LV dilation, resulting in worsening of MR. Mitral valve (MV) surgical repair has provided improvement in survival, LV function and symptoms, especially when performed early. Surgical repair is complex, due to diverse etiologies and has significant complications. The Society for Thoracic Surgery database shows that operative mortality for a 1st repair is 2% and for re-do repair is 4 times that. Cardiopulmonary bypass and cardiac arrest are required. The attendant morbidity prolongs hospitalization and recovery. Alfieri simplified mitral repair using an edge-to-edge technique which subsequently has been shown to be effective for multiple etiologies of MR. The MV leaflers are typically brought together by a central suture producing a double orifice MV without stenosis. Umana reported that MR decreased from grade 3.6 +/,0.5 to0.8 +/,0.4 (P < 0.0001)and LV ejection fraction increased from 33 +/,13% to 45 +/,11%(P = 0.0156). In 121 patients, Maisano reported freedom from re-operation of 95 +/,4.8% with up to 6 year follow-up. Oz developed a MV "grasper" that is directly placed via a left ventriculotomy and coapts both leaflets which are then fastened by a graduated spiral screw. An in-vitro model using explanted human valves showed significant reduction in MR and in canine studies, animals followed by serial echo had persistent MV coaptation. At 12 weeks the device was endothelialized. These promising results have paved the way for a percutaneous or minimally invasive off pump mitral repair. Evalve has developed catheter-based technology, which, by apposing the edges of a regurgitant MV, results in edge-to-edge repair. Release of the device is done after echo and fluoroscopic evaluation under normal loading conditions. If the desired effect is not produced the device can be repositioned or retrieved. Animal studies show excellent healing, with incorporation of the device into the leaflets at 6,10 weeks with persistent coaptation. Another percutaneous approach has been to utilize the proximity of the coronary sinus (CS) to the mitral annulus (MA). Placement of a self-compressing device in the CS along the region of the posterior MA has, in canine models, reduced MR and addresses the issues of MA dilation and its contribution to MR. Ongoing studies are underway for both techniques. (J Interven Cardiol 2003;16:93,96) [source]


    Persistence of Left Supracardinal Vein in an Adult Patient with Heart,Hand Syndrome and Cardiac Pacemaker

    CONGENITAL HEART DISEASE, Issue 3 2008
    Jan Nemec MD
    ABSTRACT A patient with a sporadic heart,hand syndrome, which includes thumb hypoplasia, septum primum atrial septal defect, and cleft mitral valve is described. During attempted placement of a pacemaker lead, persistence of left superior and inferior vena cava was found in addition to the right-sided caval veins. This corresponds to persistence of left-sided supracardinal vein present during fetal development. [source]


    Cor Triatriatum Sinister with and without Left Ventricular Inflow Obstruction: Visualization of the Entire Supravalvular Membrane by Real-time Three-dimensional Echocardiography.

    CONGENITAL HEART DISEASE, Issue 6 2006
    Impact on Clinical Management of Individual Patient
    ABSTRACT We present 4 cases of cor triatriatum in whom the diagnosis was correctly made by 2-dimensional transthoracic echocardiography, which showed the supravalvular left atrial membrane that divides the left atrium into 2 chambers. The pulmonary veins were connected normally to the proximal left atrial chamber and the left atrial appendage was connected to the distal left atrial chamber. In 1 patient there was evidence of severe pulmonary venous obstruction to the mitral valve by Doppler examination, while in the other three, there was no venous obstruction. Patients were then examined by real-time 3-dimensional echocardiography (RT3DE, using ×4 matrix array transducer connected to Sonos 7500 echocardiographic system Phillips, Andover, Mass, USA). This showed the exact morphology of the membrane and led to cancellation of planed surgical intervention in 1 case in which the membrane was only a broad band crossing the left atrial cavity. In addition to delineating the exact morphology of the intracavitary anomaly, this novel echocardiographic imaging modality should be an additive tool to better understand the natural history of these nonobstructive left atrial membranes via longitudinal follow-up of these patients. [source]


    ORIGINAL INVESTIGATIONS: Potential Faces of Patent Foramen Ovale (PFO PFO)

    ECHOCARDIOGRAPHY, Issue 8 2010
    F.R.C.P., Tasneem Z Naqvi M.D.
    Background: Patent foramen ovale (PFO) is diagnosed on echocardiography by saline contrast study with or without color Doppler evidence of shunting. PFO is benign except when it causes embolic events. Methods and Results: In this report, we describe unique additional manifestations related to the diagnosis and presentation of PFO. These include demonstration of PFO during the release phase of "sigh" on the ventilator in the operating room, use of a separate venipuncture to allow preparation of blood-saline-air mixture after multiple failed saline bubble injections, resting and stress hypoxemia related to left to right shunting across a PFO in the absence of pulmonary hypertension, presentation of quadriperesis secondary to an embolic event from a PFO and development of a thrombus on the left atrial aspect of PFO in a patient with atrial fibrillation, and on the right atrial aspect of PFO in a patient who had undergone repair of a flail mitral valve. Finally, in one patient with end-stage renal disease, aortic valve endocarditis and periaortic abscess, PFO acted as a vent valve relieving right atrial pressure following development of aortoatrial fistula. Conclusion: PFO diagnosis can be elusive if appropriate techniques are not used during saline contrast administration. PFO can present as hypoxemia in the absence of pulmonary hypertension, can be a rare cause of quadriperesis, and can be associated with thrombus formation on either side of interatrial septum. Finally, PFO presence can be lifesaving in those with sudden increase in right atrial pressure such as with aortoatrial fistula. (Echocardiography 2010;27:897-907) [source]


    Staphylococcus aureus Infective Endocarditis Mimicking a Hydatid Cyst

    ECHOCARDIOGRAPHY, Issue 8 2010
    Jeroen Walpot M.D.
    We report an atypical echocardiographic presentation of Staphylococcus aureus infective endocarditis (IE) of the mitral valve in an octogenarian female. Echocardiography revealed perforation of the anterior mitral valve leaflet (AMVL), with a large cystic mass seemingly attached to the AMVL and surrounded by a thin membranous structure. These images were strongly reminiscent of a hydatid cyst. The significant comorbidity of the patient did not justify an urgent surgical approach, and the patient subsequently expired of cardiogenic and septic shock. Autopsy revealed a large vegetation attached to the interatrial septum in the immediate proximity of the AMVL, without signs of the membranous structure and without pathological evidence for septic embolism. This atypical presentation of IE prompted us to discuss a brief review of intracardiac cystic masses. (Echocardiography 2010;27:E80-E82) [source]


    Depicting of a Cleft Mitral Valve by Real Time Three-Dimensional Transesophageal Echocardiography

    ECHOCARDIOGRAPHY, Issue 3 2010
    F.E.S.C., Mehmet Özkan M.D.
    We report the usefulness of real time three-dimensional transesophageal echocardiography in comprehensive delineation of cleft mitral valve. This new technique may be a useful supplement to two-dimensional and three-dimensional transthoracic echocardiography in the assessment of this pathology. (Echocardiography 2010;27:356-358) [source]


    Lesions of the Mitral Valve as a Cause of Central Retinal Artery Occlusion: Presentation and Discussion of Two Cases

    ECHOCARDIOGRAPHY, Issue 1 2010
    Maryam Ayati M.D.
    We present two cases of mitral valve lesions that manifested with unilateral blindness caused by central retinal artery occlusion (CRAO): Case 1. A 68-year-old woman was admitted to our clinic for sudden blindness. Retinal artery angiogram showed CRAO. Transthoracic and transesophageal echocardiography (TEE) documented a mass attached to the ventricular side of the posterior mitral leaflet, which at pathology was identified as a blood cyst. Case 2. A 67-year-old man was admitted for a sudden unilateral painless loss of vision. Retinal angiogram documented CRAO, and TEE showed a highly mobile, spherical, lesion on the atrial side of anterior mitral leaflet. In this case, the pathological finding was a degenerated calcified thrombosis. We report on two cases of very rare abnormalities of the mitral valve presenting with a very rare embolic complication, i.e., CRAO. Like for cryptogenic stroke, transesophageal echocardiography plays a central role in the diagnosis of cardiogenic embolic sources. (Echocardiography 2010;27:E1-E3) [source]


    Is the Presence of Mitral Annular Calcification Associated with Poor Left Atrial Function?

    ECHOCARDIOGRAPHY, Issue 8 2009
    Vignendra Ariyarajah M.D.
    Introduction: Mitral annular calcification (MAC) is characterized by calcium and lipid deposition in the annular fibrosa of the mitral valve. MAC is associated with cardiovascular events but little is known of its association with left atrial (LA) function. Methods: We prospectively obtained 12-lead electrocardiograms (ECGs) and transthoracic echocardiograms (TTE) on patients scheduled for nonemergent echocardiographic assessment at a tertiary care hospital. MAC was graded as 0 = none, 1 = mild, 2 = moderate, 3 = severe. LA linear and volume measurements (stroke volume, LA passive emptying fraction, LA active emptying fraction and LA kinetic energy) were done specifically in addition to commonly measured TTE parameters. Results: From the 124 considered for the study, 72 patients remained (aged 68±18 years; 44% male) after excluding those with poor ECG tracings and/or poor TTE images. Eighteen patients had MAC; mild MAC = 14, moderate MAC = 3, severe MAC = 1. When patients with MAC were compared to those without MAC, no significant difference was noted, except for LA linear dimension index (2.1±0.4 vs. 1.9±0.3 cm/m2; P = 0.03). For those with mild and moderate MAC, a trend was noted toward lower LA function with increasing MAC severity. In addition, significant differences were noted between those with and without interatrial conduction delay, where those with such delay had significantly impaired LA stroke volume (9.8±3 vs. 19.93±4 ml; P < 0.0001), LA active emptying fraction (18.83±8 vs. 65.71±9%; P < 0.0001) and LA total/reservoir fraction (39.54±6 vs. 75.1±6%; P < 0.0001). Conclusions: MAC is associated with increase in LA linear dimension on TTE and may be equally represented with lower overall LA function. Further study in a much larger cohort is warranted to delineate these and other potential associations of MAC. [source]


    Value of Transesophageal 3D Echocardiography as an Adjunct to Conventional 2D Imaging in Preoperative Evaluation of Cardiac Masses

    ECHOCARDIOGRAPHY, Issue 6 2008
    Silvana Müller M.D.
    Background: This study sought to compare three-dimensional (3D) and two-dimensional (2D) transesophageal echocardiography (TEE) to assess intracardiac masses. It was hypothesized that 3D TEE would reveal incremental information for surgical and nonsurgical management. Methods: In 41 patients presenting with intracardiac masses (17 thrombi, 15 myxomas, 2 lymphomas, 2 caseous calcifications of the mitral valve and one each of hypernephroma, hepatocellular carcinoma, rhabdomyosarcoma, lipoma, and fibroelastoma), 2D and 3D TEE were performed, aiming to assess the surface characteristics of the lesions, their relationship to surrounding structures, and attachments. Diagnoses were made by histopathology (n = 28), by computed tomography (n = 8), or by magnetic resonance imaging (n = 5). Benefit was categorized as follows: (A) New information obtained through 3D TEE; (B) helpful unique views but no additional findings compared to 2D TEE; (C) results equivalent to 2D TEE; (D) 3D TEE missed 2D findings. Results: In 15 subjects (37%), 3D TEE revealed one or more items of additional information (category A) regarding type and site of attachment (n = 9, 22%), surface features (n = 6, 15%), and spatial relationship to surrounding structures (n = 8, 20%). In at least 18% of all intracardiac masses, 3D TEE can be expected to deliver supplementary information. In six patients, additional findings led to decisions deviating from those made on the basis of 2D TEE. In 11 subjects (27%), 3D echocardiographic findings were categorized as "B." Conclusions: Information revealed by 3D imaging facilitates therapeutic decision making and especially the choice of an optimal surgical access prior to removal of intracardiac masses. [source]


    ORIGINAL INVESTIGATIONS: Tissue Harmonic Imaging in Echocardiography: Better Valve Imaging, But at What Cost?

    ECHOCARDIOGRAPHY, Issue 2 2008
    Karin Hawkins M.D.
    Background: Tissue harmonic imaging (THI) improves echocardiographic image quality and is widely utilized. Unfortunately it also makes structures appear artificially thickened. We sought to examine its impact on the imaging of left-sided heart valves. Methods: A large echocardiographic database was searched for full, standard transthoracic echocardiographic exams performed 12-month periods before (n = 3,786) and after (n = 3,914) transition to THI at a single institution. Patients with prosthetic valves were excluded. Results: The mean age of patients was 63 ± 17 years and 65% were men. No appreciable difference in demographics was observed between time periods. While inadequate visualization of the mitral valve was reduced by 30% using THI (P = 0.014), reports of leaflet thickening increased by 28% (P = 0.005). Similarly, inadequate aortic valve visualization was reduced by 53% with THI (P < 0.001), at the expense of more aortic sclerosis (+6%, P = 0.034). Among the 480 patients with echocardiograms using each modality (time interval between studies: 370 ± 143 days), THI did not appreciably improve visualization of the either valve. Although no significant increase in mitral thickness was seen with THI, aortic sclerosis was increased by at least one grade in 24.5% (P < 0.006). Conclusion: This study suggests that while THI enhances imaging of difficult to visualize valves, it may overestimate mitral and aortic valve thickness. This could lead to overdiagnosis and unnecessary follow-up studies. Cardiologists interpreting THI echocardiograms should become familiar with the modality's shortcomings. [source]


    A New Echocardiographic Index for Assessing Left Ventricular Function and Mechanism of Mitral Regurgitation and Its Relation to Other Echocardiographic Indices

    ECHOCARDIOGRAPHY, Issue 6 2007
    Cemal Sag M.D.
    Objective: Mitral regurgitation (MR) is a progressive disease of the mitral valve, which can be primary or functional. The assessment of left ventricular function in MR is still troublesome. In this study, we evaluated the validity of a new parameter, total dt, in patients with MR. Methods: Forty patients with severe MR constituted the study group. According to the transesophageal echocardiographic evaluation, the patients were dichotomized into two groups: (1) Primary MR; n = 21, (2) Functional MR; n = 19. The total dt was defined as the sum of time intervals from 1 msto 3 ms (positive dt) and from 3 ms to 1 ms (negative dt) on the CW Doppler recording of MR jet. It was compared to other indices of left ventricular function and left ventricular geometry, including ejection fraction, fractional shortening, myocardial performance index, coaptation distance, left ventricular volume and diameter, sphericity index, and parameters of diastolic function. Result: The total dt correlated with myocardial performance index, coaptation distance, and sphericity index. It could differentiate between primary and functional MR with an area under curve of 0.878, followed by myocardial performance index with 0.860. The total dt > 104 ms was 79% sensitive and 81% specific for discrimination. Conclusion: The total dt is useful for assessing left ventricular function and also for differentiating primary MR from functional MR. [source]


    Prosthetic Valve Thrombosis Presenting as an Acute Embolic Myocardial Infarction in a Pregnant Patient: Issues on Anticoagulation Regimens and Thrombolytic Therapy

    ECHOCARDIOGRAPHY, Issue 9 2006
    Padmini Varadarajan M.D.
    Mechanical valves are inherently thrombogenic and require meticulous anticoagulation. Pregnancy produces a hypercoagulable state and achieving adequate anticoagulation is difficult. We present a pregnant patient who had a nonobstructive thrombus of mechanical mitral valve causing embolic acute myocardial infarction. Issues surrounding management of anticoagulation and use of thrombolytic therapy during pregnancy are discussed. Education regarding the critical nature of adequate anticoagulation in these patients is important. [source]


    Assessment of the Tilting Properties of the Human Mitral Valve during Three Main Phases of the Heart Cycle: An Echocardiographic Study

    ECHOCARDIOGRAPHY, Issue 4 2006
    Daniel Vanhercke B.N., N.F.E.S.C., R.D.C.S.
    Rationale and Objectives: In experimental models of the left heart, the mitral valve (MV) is commonly implanted perpendicular to a central axis of the apex/MV. To adapt this to a more correct anatomical model, as well as for further studies of the left ventricle, we created a database of implantation angles of the MV and annulus during three main phases of the heart cycle, based on standard cardiac ultrasound measurements. Materials and Methods: Twenty-eight patients were studied with the standard cardiac ultrasound equipment. From the apical echo window, an anteroposterior (AP) plane and a perpendicular commisure-commisure (CC) plane were generated during three critical moments in the heart cycle: systole (S); diastole early filling (E); and diastole late filling (A). In both planes, the angles between the annular plane and each mitral leaflet, as well as the angle between a theoretical longitudinal axis through the apex and center of the MV orifice and the mitral annulus plane, were measured with a custom-made application of Matlab R14. Results: We observed an inclination of the angle mitral annulus/central left ventricle axis, with its lowest point in the direction of the aortic valve (AP plane) of 85°± 7° in systole (S), 88°± 8° in early diastole (E), and 88°± 7° in late diastole (A). In the CC plane, we observed an almost horizontal implantation of 91°± 5° in systole (S), 91°± 8° in early diastole (E), and 91°± 7° in late diastole (A). [source]


    The Double Jeopardy of Blunt Chest Trauma: A Case Report and Review

    ECHOCARDIOGRAPHY, Issue 3 2006
    Subha L. Varahan M.D.
    Cardiac injury, specifically valvular rupture, must be considered after blunt chest trauma even in previously healthy patients. Isolated mitral regurgitation (MR) and tricuspid regurgitation (TR) due to blunt chest trauma are rare phenomena. More unique is simultaneous complete papillary muscle rupture of the mitral valve (MV) and tricuspid valve (TV) with only four patients being previously reported in the literature. This case describes a patient with complete transection of the posteromedial papillary muscle of the MV with severe MR and a concomitant flail TV with severe TR following a motor vehicular accident. The importance of transthoracic and transesophageal echocardiography in the early evaluation of patients following blunt chest trauma is also highlighted by this case. [source]


    3 ISCHEMIC MITRAL VALVE REPAIR: THE IMPACT OF THE MECHANISM OF MITRAL REGURGITATION ON LATE POSTOPERATIVE RESULTS

    ECHOCARDIOGRAPHY, Issue 1 2004
    E. Ereminien
    Aim: The aim of our study was to establish the anatomical-functional mechanisms of ischemic mitral regurgitation (MR) and to analyse its impact on late results after mitral valve (MV) reconstructive surgery. Methods: The study included 53 patients with ischemic MR, who underwent CABG and MV repair. MV surgery consisted of subvalvular apparatus repair and/or annuloplasty. 2D Doppler investigations performed pre-, 10,14 days, and 12 months after surgery included evaluation of MV and left ventricular (LV) geometry and function. Results: Analysis of the mechanisms of ischemic MR permitted dividing patients into two groups: group 1,29 patients with inferobasal scar and posterior papillary muscle (PM) displacement, including 22 patients with PM infarction and 7 patients without it, and group 2,24 patients with isolated mitral annulus (MA) dilation. In the case of PM infarction two different mechanisms of MR were stated: (a) P3 restriction and A3 prolapse due to chordal tethering, (b) A3 P3 (commissural) prolapse due to chordal papillary elongation. Preoperatively LV geometry and function were better preserved in group 1 and late MV repair results were better versus (vs.) group 2: LV end-systolic diameter index decreased from 22.9 ± 3.1 mm/m2 to 20.9 ± 3.6 mm/m2 at 1 year, p < 0.05, LV ejection fraction increased from 34.9 ± 8.4 to 41.8 ± 8.1%, respectively, p < 0.05. No significant changes in LV geometry and function were noted in group 2. Conclusions: The underlying mechanism of ischemic MR has an impact on MV repair results. In patients with MR due to posterobasal infarction MV repair resulted in more favorable postoperative effect-marked improvement in LV geometry and function late after surgery versus MR due to isolated MA dilation. [source]


    Critical Left Ventricular Outflow Tract Obstruction Due to Accessory Mitral Valve Tissue

    ECHOCARDIOGRAPHY, Issue 2 2000
    RAFFAELE CALABRO M.D.
    Left ventricular outflow tract (LVOT) obstruction due to anomalous tissue tag arising from the mitral valve is a rare congenital cardiac anomaly. It generally becomes symptomatic during the first decade of life as exercise intolerance, chest pain, or syncope at effort. To date, only a few cases of critical systemic obstruction due to isolated mitral valve anomaly in neonates have been reported. We report the case of a neonate who was a few hours old and was referred in severe clinical condition due to critical left ventricular outflow obstruction resulting from an anomalous tissue tag of mitral valve origin. [source]


    Infective endocarditis in a hemodialysis patient: A dreaded complication

    HEMODIALYSIS INTERNATIONAL, Issue 4 2007
    Claudia SCHUBERT
    Abstract Infection is the most common cause of death in hemodialysis patients, after cardiovascular disease. Dialysis access infections, with secondary septicemia, contribute significantly to patient mortality. The most common source is temporary catheterization. Bacteremia occurs commonly in patients receiving hemodialysis, with infective endocarditis being a relatively uncommon, but potentially lethal complication. Valvular calcification is the most significant risk factor. The diagnosis of infective endocarditis is made clinically and confirmed with the echocardiographic modified Duke's criteria. The most common pathogen is Staphylococcus aureus and the mitral valve is the most common site. Staphylococcus aureus infective endocarditis is commonly associated with embolic phenomenon. A high index of suspicion is critical in the early recognition and management of infective endocarditis. However, prevention of bacteremia is undoubtedly the best strategy with the early placement of arteriovenous fistulae. In the case of temporary catheterization, the use of topical mupirocin or polysporin and gentamicin and/or citrate locking is beneficial. Although catheter salvage has not been studied in randomized trials, catheter removal remains standard therapy during bacteremia. [source]


    2-D transmitral flows simulation by means of the immersed boundary method on unstructured grids

    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN FLUIDS, Issue 12 2002
    F. M. Denaro
    Abstract Interaction between computational fluid dynamics and clinical researches recently allowed a deeper understanding of the physiology of complex phenomena involving cardio-vascular mechanisms. The aim of this paper is to develop a simplified numerical model based on the Immersed Boundary Method and to perform numerical simulations in order to study the cardiac diastolic phase during which the left ventricle is filled with blood flowing from the atrium throughout the mitral valve. As one of the diagnostic problems to be faced by clinicians is the lack of a univocal definition of the diastolic performance from the velocity measurements obtained by Eco,Doppler techniques, numerical simulations are supposed to provide an insight both into the physics of the diastole and into the interpretation of experimental data. An innovative application of the Immersed Boundary Method on unstructured grids is presented, fulfilling accuracy requirements related to the development of a thin boundary layer along the moving immersed boundary. It appears that this coupling between unstructured meshes and the Immersed Boundary Method is a promising technique when a wide range of spatial scales is involved together with a moving boundary. Numerical simulations are performed in a range of physiological parameters and a qualitative comparison with experimental data is presented, in order to demonstrate that, despite the simplified model, the main physiological characteristics of the diastole are well represented. Copyright © 2002 John Wiley & Sons, Ltd. [source]


    Mycotic aneurysm of the superior mesenteric artery in a young woman

    INTERNATIONAL JOURNAL OF CLINICAL PRACTICE, Issue 5 2005
    P-H Chu
    Summary Aneurysm of the superior mesenteric artery (SMA) is rare. We, in this study, present the case of a 21-year-old woman with a history of heroin abuse who was admitted to our hospital for infective endocarditis complicated by floating vegetation at the posterior mitral valve. After receiving 2-week antibiotic treatment, the patient had acute abdominal pain. Computed tomography demonstrated an aneurysm at the SMA. The mycotic aneurysm was resected and the mitral valve was repaired successfully. This report reviews the pathophysiology of mycotic aneurysms of the SMA and role of computed tomography in the differential diagnosis of this condition from acute mesenteric ischaemia. [source]


    Evaluation of Left Ventricular Diastolic Function after Edge-to-Edge Mitral Valve Plasty

    JOURNAL OF CARDIAC SURGERY, Issue 1 2010
    Yong-Qiang Lai M.D.
    This procedure anchors the correspondence leaflets to create a double-orifice mitral valve. The original mitral valve anatomy is changed, and the opening of mitral valve is restricted. Little is known whether this procedure affects the left ventricular diastolic function. Methods: Thirty patients with mitral regurgitation were included in this study. Fifteen with posterior leaflet prolapse received quadrangular resection (group 1), 15 with anterior or bileaflet prolapse underwent edge-to-edge procedure (group 2). Acute hemodynamics was monitored with a Swan-Ganz catheter (Edwards Lifesciences LLC, Irvine, CA, USA). Left ventricular diastolic function was also evaluated with echocardiography in 28 patients with sinus rhythm. The ratio of peak E velocity and A velocity (E/A), the ratio of early diastolic peak flow velocity to early diastolic mitral annular movement velocity (E/Em), and the ratio of early diastolic mitral annular velocity to late diastolic mitral annular velocity (Em/Am) were measured before operation and one week after operation. Results: Mitral valve area and mitral regurgitate grade decreased significantly after operation. There was no significant change in pulmonary artery wedge pressure between two groups and in each group before and after operation. Echocardiography evaluation showed there was no significant difference in E/A, E/Em, and Em/Am before and after operation between two groups and in each group. Conclusion: Edge-to-edge mitral valve plasty procedure has no significant impairment on left ventricular diastolic function. A double-orifice mitral valve has similar hemodynamic behavior with a physiological valve.(J Card Surg 2010;25:5-8) [source]


    Usefulness of Intraoperative Real-Time 3D Transesophageal Echocardiography in Cardiac Surgery

    JOURNAL OF CARDIAC SURGERY, Issue 6 2008
    Thierry V. Scohy M.D.
    Methods: Preoperative transthoral echocardiography (TTE) revealed: hypertrophic ventricular septum (TTE:19.3 mm), systolic anterior motion (SAM) not causing obstruction and malcoaptation of the anterior mitral valve leaflet (AMVL), and posterior mitral valve leaflet (PMVL) with severe mitral regurgitation. Results: Intraoperative TEE with a x7-2t MATRIX-array transducer (Philips, Andover, MA, USA) with a transducer frequency of x7,2 t mHz, connected to a iE33 (Philips), shows us that the main mechanism and site of regurgitation was an AMVL cleft. We also measured a 24.3-mm thickness of the ventricular septum and analyzing the 3D full volume acquisition revealed that there was no SAM. Conclusion: Intraoperative RT3DTEE permitted comprehensive 3D viewing of the mitral valve revealing the mechanism of mitral valve regurgitation, SAM, and the exact width of the hypertrophic ventricular septum. [source]


    Chordal Cutting VIA Aortotomy in Ischemic Mitral Regurgitation: Surgical and Echocardiographic Study

    JOURNAL OF CARDIAC SURGERY, Issue 1 2008
    Georges Fayad M.D.
    In addition, MR may exacerbate during exercise not only trough exercise-induced ischemia but also through an increase in tenting area. Accordingly, we aimed to perform chordal cutting through aortotomy in patients with exercise-induced ischemic worsening of MR. Methods: Five patients with ischemic MR, due to anterior leaflet tenting, whichworsened during exercise echocardiography were enrolled. All patients underwent cutting of the 2 basal chordae attached to the anterior mitral leaflet associated with myocardial revascularization. Three patients had additional mitral valve annuloplasty. Postoperative MR was evaluated using exercise echocardiography. Results: Age ranged from 63 to 78 years and 4 patients were male. Preoperative LV ejection fraction averaged 39 ± 3%. Chordal cutting was performed through aortotomy allowing comfortable access to the anterior mitral valve. Mitral effective regurgitant orifice at rest and at peak exercise was reduced by surgery (10 ± 3 to 0.6 ± 0.5 mm2 at rest and from 20 ± 3 to 6 ± 2 mm2 at peak exercise; p = 0.03). Mitral tenting area at rest and at peak exercise was concomitantly reduced by surgery (1.83 ± 0.21 cm2 to 0.50 ± 0.4 cm2 at rest and from 3.11 ± 0.58 to 1.7 ± 0.5 cm2 at peak exercise; p = 0.03). Left ventricular size and function remained unchanged after surgery. Conclusions: Chordal cutting through aortotomy may be an effective option to treat ischemic MR due to anterior leaflet tenting. Associated with myocardial revascularization, it resulted in a decrease of MR at rest and during exercise through a decrease in tenting area without impairment of LV function. [source]


    Delayed Presentation of Low Molecular Weight Heparin Treatment Failure in a Patient With Mitral Valve Prosthesis

    JOURNAL OF CARDIAC SURGERY, Issue 1 2007
    Sotiris C. Stamou M.D.
    The patient did not develop the embolic complication from the thrombosis until almost 4 months after the bridging sequence with low molecular weight heparin. The patient underwent thrombectomy of the mitral valve. At least 16 similar cases with mechanical valve prostheses and treatment failure of low molecular weight heparin have been reported. [source]