Method Validation (method + validation)

Distribution by Scientific Domains

Kinds of Method Validation

  • bioanalytical method validation


  • Selected Abstracts


    Determination of clavulanic acid in calf plasma by liquid chromatography tandem mass spectrometry

    JOURNAL OF MASS SPECTROMETRY (INCORP BIOLOGICAL MASS SPECTROMETRY), Issue 11 2006
    Tim Reyns
    Abstract A method for the quantification of clavulanic acid in calf plasma using high-performance liquid chromatography combined with electrospray ionization (ESI) mass spectrometry, operating in the negative ionization mode (LC-MS/MS), is presented. Sample preparation includes a simple and fast deproteinization with acetonitrile and a back-extraction of the acetonitrile with dichloromethane. Chromatography is performed on a reversed-phase PLRP-S polymeric column using 0.05% formic acid in water and acetonitrile. The limit of quantification is 25 ng/ml, which is lower than other published methods using ultraviolet (UV), fluorimetric or mass spectrometric detection. The limit of detection is calculated to be 3.5 ng/ml. The stability of clavulanic acid was demonstrated according to The Guidelines of Bioanalytical Method Validation of The Food and Drug Administration (FDA): freeze and thaw stability, short-term stability, long-term stability, stock solution stability and postpreparative stability. The method is used in a pharmacokinetic and bioequivalence study of amoxycillin/clavulanic acid formulations in calves. Copyright © 2006 John Wiley & Sons, Ltd. [source]


    LC-MS/MS determination of 2-(4-((2-(2S,5R)-2-Cyano-5-ethynyl-1-pyrrolidinyl)-2-oxoethylamino)-4-methyl-1-piperidinyl)-4-pyridinecarboxylic acid (ABT-279) in dog plasma with high-throughput protein precipitation sample preparation

    BIOMEDICAL CHROMATOGRAPHY, Issue 11 2007
    Joseph Kim
    Abstract As an effective DPP-IV inhibitor, 2-(4-((2-(2S,5R)-2-Cyano-5-ethynyl-1-pyrrolidinyl)-2-oxoethylamino)-4-methyl-1-piperidinyl)-4-pyridinecarboxylic acid (ABT-279), is an investigational drug candidate under development at Abbott Laboratories for potential treatment of type 2 diabetes. In order to support the development of ABT-279, multiple analytical methods for an accurate, precise and selective concentration determination of ABT-279 in different matrices were developed and validated in accordance with the US Food and Drug Administration Guidance on Bioanalytical Method Validation. The analytical method for ABT-279 in dog plasma was validated in parallel to other validations for ABT-279 determination in different matrices. In order to shorten the sample preparation time and increase method precision, an automated multi-channel liquid handler was used to perform high-throughput protein precipitation and all other liquid transfers. The separation was performed through a Waters YMC ODS-AQ column (2.0 × 150 mm, 5 µm, 120 Å) with a mobile phase of 20 mm ammonium acetate in 20% acetonitrile at a flow rate of 0.3 mL/min. Data collection started at 2.2 min and continued for 2.0 min. The validated linear dynamic range in dog plasma was between 3.05 and 2033.64 ng/mL using a 50 µL sample volume. The achieved r2 coefficient of determination from three consecutive runs was between 0.998625 and 0.999085. The mean bias was between ,4.1 and 4.3% for all calibration standards including lower limit of quantitation. The mean bias was between ,8.0 and 0.4% for the quality control samples. The precision, expressed as a coefficient of variation (CV), was ,4.1% for all levels of quality control samples. The validation results demonstrated that the high-throughput method was accurate, precise and selective for the determination of ABT-279 in dog plasma. The validated method was also employed to support two toxicology studies. The passing rate was 100% for all 49 runs from one validation study and two toxicology studies. Copyright © 2007 John Wiley & Sons, Ltd. [source]


    Determination of thiol compounds by automated headspace solid-phase microextraction with in-fiber derivatization

    FLAVOUR AND FRAGRANCE JOURNAL, Issue 3 2006
    Qing Wang
    Abstract In this article, headspace solid-phase microextraction (HS-SPME) analysis of thiol compounds with both solid and aqueous samples was investigated using N -phenylmaleimide as an in-fiber derivatization reagent. The derivatives were analyzed using GC-MS. The HS-SPME method was executed on an automatic sampler and optimized by studying a variety of factors such as the selection of the fiber, extraction time, temperature, agitation speed, etc. Method validation was carried out by spiking known amounts of thiol compounds into the sample and calculating the concentration by standard addition. The relative standard deviations (RSD) for the majority of the thiols were less than 10%. The developed method resulted in a limit of detection (LOD) in the low microgram per liter for most of the thiols analyzed, which was about one order of magnitude lower than the HS-SPME without derivatization. Finally, the overall method was successfully applied for the determination of thiols in yellow onion, green onion and garlic. Copyright © 2006 John Wiley & Sons, Ltd. [source]


    Quantification of montelukast, a selective cysteinyl leukotriene receptor (CysLT1) antagonist in human plasma by liquid chromatography,mass spectrometry: validation and its application to a human pharmacokinetic study

    BIOMEDICAL CHROMATOGRAPHY, Issue 8 2009
    D. Vijaya Bharathi
    Abstract A highly sensitive, rapid assay method has been developed and validated for the estimation of montelukast (MTK) in human plasma with liquid chromatography coupled to tandem mass spectrometry with electro spray ionization in the positive-ion mode. Liquid,liquid extraction was used to extract MTK and amlodipine (internal standard, IS) from human plasma. Chromatographic separation was achieved with 10 mm ammonium acetate (pH 6.4): acetonitrile (15:85, v/v) at a flow rate of 0.50 mL/min on a Discovery HS C18 column with a total run time of 3.5 min. The MS/MS ion transitions monitored were 586.10 , 422.10 for MTK and 409.20 , 238.30 for IS. Method validation and clinical sample analysis were performed as per FDA guidelines and the results met the acceptance criteria. The lower limit of quantitation achieved was 0.25 ng/mL and linearity was observed from 0.25 to 800 ng/mL. The intra-day and inter-day precisions were 5.97,8.33 and 7.09,10.13%, respectively. This novel method has been applied to a pharmacokinetic study of MTK in humans. Copyright © 2009 John Wiley & Sons, Ltd. [source]


    Highly sensitive method for the determination of ropinirole with a lower limit of quantitation of 3.45 pg/mL in human plasma by LC-ESI-MS/MS: application to a clinical pharmacokinetic study

    BIOMEDICAL CHROMATOGRAPHY, Issue 5 2009
    D. Vijaya Bharathi
    Abstract A highly sensitive, rapid assay method has been developed and validated for the estimation of ropinirole (RPR) in human plasma with liquid chromatography coupled to tandem mass spectrometry with electrospray ionization in the positive-ion mode. A solid-phase process was used to extract RPR and citalopram (internal standard, IS) from human plasma. Chromatographic separation was operated with 0.2% ammonia solution:acetonitrile (20:80, v/v) at a flow rate of 0.50 mL/min on a Hypurity C18 column with a total run time of 3.2 min. The MS/MS ion transitions monitored were 261.2 , 114.2 for RPR and 325.1 , 209.0 for IS. Method validation and clinical sample analysis were performed as per FDA guidelines and the results met the acceptance criteria. The lower limit of quantitation achieved was 3.45 pg/mL and the linearity was observed from 3.45 to 1200 pg/mL. The intra-day and inter-day precisions were in the range of 4.71,7.98 and 6.56,8.31%, respectively. This novel method has been applied to a pharmacokinetic study of RPR in humans. Copyright © 2008 John Wiley & Sons, Ltd. [source]


    Highly sensitive method for the determination of omeprazole in human plasma by liquid chromatography,electrospray ionization tandem mass spectrometry: application to a clinical pharmacokinetic study

    BIOMEDICAL CHROMATOGRAPHY, Issue 4 2009
    Shivva Vittal
    Abstract A highly sensitive, rapid assay method has been developed and validated for the estimation of omeprazole (OPZ) in human plasma with liquid chromatography coupled to tandem mass spectrometry with electrospray ionization in the positive-ion mode. The assay procedure involves alkalinization of plasma followed by simple liquid,liquid extraction of OPZ and lansoprazole (internal standard, IS) from human plasma with acetonitrile. Chromatographic separation was achieved with 0.01 m ammonium acetate:acetonitrile (40:60, v/v) at a flow rate of 0.25 mL/min on an Inertsil ODS 3 column with a total run time 2.5 min. The MS/MS ion transitions monitored were 346.1 , 198.1 for OPZ and 370.1 , 252.1 for IS. Method validation and clinical sample analysis were performed as per FDA guidelines and the results met the acceptance criteria. The lower limit of quantitation achieved was 0.05 ng/mL and the linearity was observed from 0.05 to 10.0 ng/mL. The intra-day and inter-day precisions were in the ranges 2.09,8.56 and 5.29,8.19%, respectively. This novel method has been applied to a pharmacokinetic study of OPZ in humans. Copyright © 2008 John Wiley & Sons, Ltd. [source]


    Method validation for measurement of hair nicotine level in nonsmokers

    BIOMEDICAL CHROMATOGRAPHY, Issue 3 2009
    Sung Roul Kim
    Abstract The development of strategies to address the growing worldwide burden of exposure to secondhand smoke (SHS) would be facilitated by sensitive and accurate methods for assessing SHS exposure. Hair provides a readily available matrix for assessing biomarkers of typical SHS exposure. We developed and applied an optimized analytical method using an isotope dilution gas chromatography,mass spectrometry (GC/MS) for hair nicotine measurement. The utility of this optimized method is illustrated by presenting data on SHS exposure of women and children from 31 countries. Using this isotope dilution method with spiked samples (3.3 ng/mg), we found that the greatest hair nicotine extraction efficiency was obtained with a 60 min shaking time. In the field study (n = 2400), a positive association was evident between hair nicotine concentrations from nonsmokers and higher numbers of cigarettes smoked per day in a household. Copyright © 2008 John Wiley & Sons, Ltd. [source]


    Development and validation of a simple thin layer chromatographic method for the analysis of artemisinin in Artemisia annua L. plant extracts

    BIOMEDICAL CHROMATOGRAPHY, Issue 5 2008
    Els Marchand
    Abstract Owing to the development of parasite resistance to standard antimalarial treatments like chloroquine and sulfadoxine,pyrimethamine, the demand for Artemisia annua, a key ingredient for new and highly effective antimalarial drugs, is huge. Therefore selective and precise methods to determine the content of artemisinin in dry plant material and in raw impure extracts are needed. In this work a method is described for the clear separation and extraction of artemisinin from other plant components in the Artemisia annua L. plant by thin-layer chromatography (TLC). To obtain optimal extraction and recovery efficiency, several parameters were evaluted, including choice of extraction solvent, TLC plate type and sensitivity between UV and visible light. Method validation was performed on both the dry plant material and non-purified plant extracts. Toluene presented the highest extraction efficiency compared with petroleum ether, hexane and methanol. Reversed-phase plates showed more concentrated spots than normal-phase plates, while the sensitivity of the analysis in UV was comparable to that in visible light but less precise. The impure plant extracts were analyzed by both TLC and HPLC-UV at 215 nm and both methods met the requirements for linearity, selectivity, precision and accuracy. Hence, the proposed TLC method can easily be used for both qualitative and quantitative control of the raw plant extract in areas where advanced methods are scarce. Copyright © 2007 John Wiley & Sons, Ltd. [source]


    Determination of ethyl sulfate , a marker for recent ethanol consumption , in human urine by CE with indirect UV detection

    ELECTROPHORESIS, Issue 23 2006
    Francesc A. Esteve-Turrillas
    Abstract A CE method for the determination of the ethanol consumption marker ethyl sulfate,(EtS) in human urine was developed. Analysis was performed in negative polarity mode with a background electrolyte composed of 15,mM maleic acid, 1,mM phthalic acid, and 0.05,mM cetyltrimethylammonium bromide (CTAB) at pH,2.5 and indirect UV detection at 220,nm (300,nm reference wavelength). This buffer system provided selective separation conditions for EtS and vinylsulfonic acid, employed as internal standard, from urine matrix components. Sample pretreatment of urine was minimized to a 1:5 dilution with water. The optimized CE method was validated in the range of 5,700,mg/L using seven lots of urine. Intra- and inter-day precision and accuracy values, determined at 5, 60, and 700,mg/L with each lot of urine, fulfilled the requirements according to common guidelines for bioanalytical method validation. The application to forensic urine samples collected at autopsies as well as a successful cross-validation with a LC-MS/MS-based method confirmed the overall validity and real-world suitability of the developed expeditious CE assay (sample throughput 130 per day). [source]


    Methodology for the evaluation of cumulative episodic exposure to chemical stressors in aquatic risk assessment,

    ENVIRONMENTAL TOXICOLOGY & CHEMISTRY, Issue 4 2000
    Michael G. Morton
    Abstract An ecological risk assessment method was developed to evaluate the magnitude, duration, and episodic nature of chemical stressors on aquatic communities. The percent of an ecosystem's species at risk from a designated chemical exposure scenario is generated. In effects assessment, probabilistic extrapolation methods are used to generate estimated safe concentrations (ESCs) for an ecosystem using laboratory toxicity test results. Fate and transport modeling is employed to generate temporal stressor concentration profiles. In risk characterization, area under the curve integration is performed on predicted exposure concentration profiles to calculate a cumulative exposure concentration (CEC) for the exposure event. A correction is made to account for the allowable exposure duration to the stressor ESC. Finally, the CEC is applied to the extrapolation model (curve) of the stressor to predict percent species at risk to the episodic exposure. The method may be used for either prospective or retrospective risk assessments. The results of a retrospective risk assessment performed on the Leadenwah Creek, South Carolina, USA, estuarine community are presented as a case study. The creek experienced periodic episodes of pesticide-contaminated agricultural runoff from 1986 through 1989. Although limited biological data were available for method validation, the risk estimates compared well with the Leadenwah Creek in situ bioassay results. [source]


    The Use of Reference Materials: A Tutorial

    GEOSTANDARDS & GEOANALYTICAL RESEARCH, Issue 1 2001
    Jean S. Kane
    reference materials; certified reference materials; method validation; traceability of measurement; geochemical analysis Any review of the analytical literature shows that, while reference materials are routinely used in laboratories world-wide, not all uses follow ISO Guide 33 (1989), which outlines best practices. Analytical data quality can suffer as a result. This paper reviews the various uses that the geoanalytical community has made of reference materials from a historical perspective, and suggests improvements in practice that would more closely follow ISO Guide 33 recommendations. Un examen de la littérature dans le domaine analytique montre que, si les matériaux de référence sont utilisés en routine dans les laboratoires du monde entier, ces derniers ne suivent pas toujours les recommandations du guide ISO 33 (1989a), qui souligne les bonnes pratiques de laboratoire. La qualité des données analytiques peut alors en souffrir. Cet article passe en revue les différentes utilisations des matériaux de référence par la communauté de géoanalyse, ceci d'un point de vue historique, et suggère des améliorations de pratiques pour suivre au mieux les recommandations du guide ISO 33. [source]


    Evaluation and use of a synthetic quality control material, included in the European external quality assessment scheme for cystic fibrosis,

    HUMAN MUTATION, Issue 8 2008
    Sarah Berwouts
    Abstract Assuring high quality within the field of genetic testing is fundamental, as the results can have considerable impact on the patient and his or her family. The use of appropriate quality control (QC) samples is therefore essential. Diagnostic laboratories mainly use patient samples as QC material, which of course include a maximum of two mutations per sample. Bearing in mind that some assays (such as for cystic fibrosis [CF] testing) can test for more than 100 mutations, multiplex QC materials including more than two mutations could save valuable time and reagents. Based on this need, synthetic multiplex controls have been developed by Maine Molecular Quality Controls, Inc. (MMQCI) for CF. A synthetic control, containing six homozygous mutations and one polymorphism for CF transmembrane conductance regulator (CFTR), was evaluated by distributing it through the CF external quality assessment (EQA) scheme, along with the EQA samples in 2005. A total of 197 participants returned results of the yearly EQA scheme and 133 laboratories participated in the evaluation of the synthetic sample. Respectively, 76% and 73% of the participants were assigned as successful. This evaluation study revealed that the multiplex QC material performed well in the majority of assays and could be useful in method validation, as a tool to challenge interpretation skills, and as potential proficiency testing (PT) material. Hum Mutat 0, 1,8, 2008. © 2008 Wiley-Liss, Inc. [source]


    Optimization of the ESI and APCI experimental variables for the LC/MS determination of s-triazines, methylcarbamates, organophosphorous, benzimidazoles, carboxamide and phenylurea compounds in orange samples

    JOURNAL OF MASS SPECTROMETRY (INCORP BIOLOGICAL MASS SPECTROMETRY), Issue 10 2007
    Guilherme M. Titato
    Abstract In this work, ten selected pesticides of different chemical groups, indicated to orange culture, were extracted and determined by liquid chromatography,mass spectrometry using both electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) operating in the positive ion detection mode. Applying a variables selection technique verified that cone voltage, source temperature and drying-gas flow-rate are the critical variables when the ESI was used, while cone voltage was found to be the only critical variable for the MS system, operating with the APCI ionization mode. After optimization of the most important parameters through the variables selection technique, the selected ion-recording (SIR) mode, monitoring the [M + H]+ species for all the compounds, was applied for the method validation of the pesticides, in both ionization modes. In orange samples, matrix effects did not interfere with the determination of the pesticides. Pesticides quantification limits ranged from 10 to 50 µg kg,1 for ESI and from 8.2 to 45 µg kg,1 for APCI. Linearity was studied from LOQ upto 200 times LOQ values (r > 0.98). Recoveries obtained were in the range of 70.2,100.5% (RSDs less than 10%). In order to guarantee that the identification and confirmation of the studied pesticides in real samples were unequivocal, characteristic fragment ions of the pesticides were obtained by varying the cone voltage (in-source CID). Copyright © 2007 John Wiley & Sons, Ltd. [source]


    Quantification of fudosteine in human plasma by high-performance liquid chromatography-electrospray ionization mass spectrometry employing precolumn derivatization with 9-fluorenylmethyl chloroformate

    JOURNAL OF MASS SPECTROMETRY (INCORP BIOLOGICAL MASS SPECTROMETRY), Issue 5 2006
    Fengguo Xu
    Abstract This paper describes a novel method for the sensitive and selective determination of fudosteine in human plasma. The method involves a derivatization step with 9-fluorenylmethyl chloroformate (FMOC-Cl) in borate buffer and detection based on high-performance liquid chromatography-electrospray ionization mass spectrometry (LC/ESI/MS). After acetonitrile-induced protein precipitation of plasma samples, fudosteine was derivatized with FMOC-Cl, then extracted by ethyl acetate, evaporated, reconstituted and injected using an LC/ESI/MS instrument. Separation was achieved using an ODS column and isocratic elution. Excellent linearity was obtained for the entire calibration range from 0.05 to 20 µg/ml. Validation assays of the lower limit of quantification (LLOQ) as well as for the intra- and inter-batch precision and accuracy met the international acceptance criteria for bioanalytical method validation. Using the developed analytical method, fudosteine could be detected for the first time in human plasma with a low limit of detection (LLOD) of 0.03 µg/ml. The proposed method has been successfully applied to study the pharmacokinetics of fudosteine in healthy Chinese volunteers after single and multiple oral administration. Copyright © 2006 John Wiley & Sons, Ltd. [source]


    A bioassay for mosquito repellency against Aedes aegypti: method validation and bioactivities of DEET analogues

    JOURNAL OF PHARMACY AND PHARMACOLOGY: AN INTERNATI ONAL JOURNAL OF PHARMACEUTICAL SCIENCE, Issue 1 2010
    Alexander Jahn
    Abstract Objectives Vector-borne diseases are still a major mortality factor in Africa and South-east Asia and effective mosquito repellents are therefore needed. An efficient and safe in-vitro assay system using artificial blood and skin substitute could facilitate the development of novel repellents, as most assays currently rely on human subjects or vertebrate whole blood. Moreover, examining the skin permeation profiles could provide safer mosquito repellents. The new assay system could serve as an initial system for testing new repellent candidates upon validation with DEET and its analogues. MethodsN,N -Diethyl- meta -toluamide (DEET) and five analogues were synthesised and used to validate a novel in-vitro bioassay using artificial blood and collagen membrane. Repellency against Aedes aegypti was correlated with lipophilicity and skin permeation. Key findings The new in-vitro assay showed good reproducibility (interday relative standard deviation <10% at high concentrations). Four of the five DEET analogues showed repellency similar or superior to that of DEET. Repellency correlated linearly with lipophilicity but stronger repellents tended to permeate skin better. Conclusions The new in-vitro assay using blood substitute and collagen membrane significantly simplifies screening of possible mosquito repellents. Lipophilicity as well as skin permeation profiles should be considered before testing of compounds that are candidates for mosquito repellents. [source]


    Enantioselective analysis of mirtazapine, demethylmirtazapine and 8-hydroxy mirtazapine in human urine after solid-phase microextraction

    JOURNAL OF SEPARATION SCIENCE, JSS, Issue 2 2010
    Fernando José Malagueño de Santana
    Abstract A selective and reproducible off-line solid-phase microextraction procedure was developed for the simultaneous enantioselective determination of mirtazapine (MRT), demethylmirtazapine and 8-hydroxymirtazapine in human urine. CE was used for optimization of the extraction procedure whereas LC-MS was used for method validation and application. The influence of important factors in the solid-phase microextraction efficiency is discussed, such as the fiber coatings, extraction time, pH, ionic strength, temperature and desorption time. Before extraction, human urine samples were submitted to enzymatic hydrolysis at 37°C for 16,h. Then, the enzyme was precipitated with trichloroacetic acid and the pH was adjusted to 8 with 1,mol/L pH 11 phosphate buffer solution. In the extraction, the analytes were transferred from the aqueous solution to the polydimethylsiloxane-divinylbenzene fiber coating and then desorbed in methanol. The mean recoveries were 5.4, 1.7 and 1.0% for MRT, demethylmirtazapine and 8-hydroxymirtazapine enantiomers, respectively. The method was linear over the concentration range of 62,1250,ng/mL. The within-day and between-day assay precision and accuracy were lower than 15%. The method was successfully employed in a preliminary cumulative urinary excretion study after administration of racemic MRT to a healthy volunteer. [source]


    Determination of 13C/12C ratios of endogenous urinary steroids: method validation, reference population and application to doping control purposes

    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, Issue 14 2008
    Thomas Piper
    The application of a comprehensive gas chromatography/combustion/isotope ratio mass spectrometry (GC/C/IRMS)-based method for stable carbon isotopes of endogenous urinary steroids is presented. The key element in sample preparation is the consecutive cleanup with high-performance liquid chromatography (HPLC) of underivatized and acetylated steroids, which allows the isolation of ten analytes (11, -hydroxyandrosterone, 5, -androst-16-en-3, -ol, pregnanediol, androsterone, etiocholanolone, testosterone, epitestosterone, 5, -androstane-3,,17, -diol, 5, -androstane-3,,17, -diol and dehydroepiandrosterone) from a single urine specimen. These steroids are of particular importance to doping controls as they enable the sensitive and retrospective detection of steroid abuse by athletes. Depending on the biological background, the determination limit for all steroids ranges from 5 to 10,ng/mL for a 10,mL specimen. The method is validated by means of linear mixing models for each steroid, which covers repeatability and reproducibility. Specificity was further demonstrated by gas chromatography/mass spectrometry (GC/MS) for each analyte, and no influence of the sample preparation or the quantity of analyte on carbon isotope ratios was observed. In order to determine naturally occurring 13C/12C ratios of all implemented steroids, a reference population of n,=,61 subjects was measured to enable the calculation of reference limits for all relevant steroidal , values. Copyright © 2008 John Wiley & Sons, Ltd. [source]


    Comparison of gas chromatography and liquid chromatography mass spectrometric measurements for high accuracy analysis of cholesterol in human serum by isotope dilution mass spectrometry

    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, Issue 9 2002
    Céline S. J. Wolff Briche
    Cholesterol measurements are of vital clinical importance and reliable reference materials are essential for method validation. Gas chromatography with mass spectrometry (GC/MS) is usually used for the high accuracy analysis of cholesterol by isotope dilution. A certified reference material for cholesterol content in human serum was analysed by isotope dilution utilising GC/MS and liquid chromatography mass spectrometry (LC/MS). The use of LC/MS avoided the need for a derivatisation step. Both LC/MS and GC/MS produced results on the measurement of cholesterol that agreed within 0.5% of the certified value. Moreover, the precision obtained for ratio measurement using both techniques are comparable and lead to relative expanded standard uncertainties (with a coverage factor of 2) varying between 0.2 and 0.5%. Copyright © 2002 John Wiley & Sons, Ltd. [source]


    Liquid chromatography tandem mass spectrometry method for determination of bisoprolol in human plasma using d5-bisoprolol as the internal standard

    BIOMEDICAL CHROMATOGRAPHY, Issue 6 2010
    Gang-yi Liu
    Abstract A simple, reliable and sensitive liquid chromatography tandem mass spectrometry (LC-MS/MS) protocol was developed and validated for quantification of bisoprolol in human plasma. The sample was pretreated with a simple procedure of protein precipitation and an isotope-labeled d5-bisoprolol was used as internal standard. The chromatographic separation was performed on a Capcell Pak C18 MG III column (100,mm × 2.0,mm, 5,µm). The protonated ion of the analyte was detected in positive ionization by multiple reaction monitoring mode. The mass transition pairs of m/z 326.3 , 116.3 and m/z 331.3 , 121.3 were used to detect bisoprolol and the internal standard, respectively. Linearity, accuracy, precision, recovery, matrix effect, dilution test and stability were evaluated during method validation over the range of 0.5,100,ng/mL. The validated method was successfully applied to analyze human plasma samples in a bisoprolol bioavailability study. Copyright © 2009 John Wiley & Sons, Ltd. [source]


    Bioanalytical LC-MS/MS method validation for plasma determination of topiramate in healthy Indian volunteers

    BIOMEDICAL CHROMATOGRAPHY, Issue 11 2009
    Dipanjan Goswami
    Abstract A LC-MS/MS method for plasma topiramate analysis is delineated involving least number of healthy volunteers. Topiramate and amlodipine internal standard (IS) were extracted by simple centrifuge-coupled solid-phase extraction and reverse-phase chromatographic separation was performed on an Ascentis C18 column. Turbo-spray negative-ion mode multiple-reaction monitoring was selected for mass pair detection at m/z 338.3 , 78.0 and m/z 407.3 , 295.5 for analyte and IS respectively. The method showed a dynamic linearity range from 10.4 to 2045.0 ng/mL, lower limit of quantitation achieved at 10.4 ng/mL and finally a mass spectrometric total run time of within 2.5 min for human sample analysis. Bioequivalence was assessed successfully using this fully validated method on 16 fasted Indian male subjects with 25 mg topiramate tablet administration. An appropriate study design describes plasma samples collection up to 216 h post dose in two periods, separated by a 28 day washout period. The challenge of half-life matching for test and reference drug was achieved with 73.43 ± 9.68 and 73.06 ± 14.03 h, respectively, and intra-subject coefficient of variation achieved within 11% for AUCs and Cmax evaluated by non-compartmental pharmacokinetic analysis. The results of LCMS topiramate complete method validation supported by pharmacokinetic study have not been published before, and are presented and discussed for the first time in this article. Copyright © 2009 John Wiley & Sons, Ltd. [source]


    Determination of S -phenylmercapturic acid in human urine using an automated sample extraction and fast liquid chromatography-tandem mass spectrometric method

    BIOMEDICAL CHROMATOGRAPHY, Issue 6-7 2006
    Yinghe Li
    Abstract S -phenylmercapturic acid is widely accepted as a specific biomarker for the evaluation of benzene exposure. Here, we describe a fast, specific and sensitive high-performance liquid achromatography coupled with tandem mass spectrometry (LC-MS/MS) method that has been developed and validated for the determination of S- phenylmercapturic acid in human urine. Isotope-labeled S- phenylmercapturic acid- d5 was used as internal standard to improve the method ruggedness. The fully automated solid-phase extraction method on a 96-well Oasis MAX (mix-mode anion exchange) plate was employed to clean up the urine samples before analysis. The rapid LC-MS/MS analysis of extracted samples was achieved on a Genesis C18 column with a run time of only 3 min. Negative electrospray ionization with multiple reaction monitoring (ESI-MRM) mode was used to detect S- phenylmercapturic acid (m/z 238 , 109) and S- phenylmercapturic acid - d5 (m/z 243 , 114). The method fulfils all the standard requirements of method validation. The calibration curve was linear within the concentration range 0.400,200 ng/mL. The method performed accurately and precisely in validation with <7.5% relative error and <6.5% relative standard deviation of quality control samples. The method efficacy was also verified by the analysis of urine samples from 12 smokers and 12 non-smokers. With the fully automated sample cleanup procedure and the fast LC-MS/MS analysis, a sample analysis throughput of 384 samples per day could be achieved. Copyright © 2006 John Wiley & Sons, Ltd. [source]


    Quantitative analysis of docetaxel in human plasma using liquid chromatography coupled with tandem mass spectrometry

    BIOMEDICAL CHROMATOGRAPHY, Issue 5 2005
    I. E. L. M. Kuppens
    Abstract An assay for the quantitative determination of docetaxel in human plasma is described. Docetaxel was extracted from the matrix using liquid,liquid extraction with ter -butylmethylether, followed by high-performance liquid chromatographic analysis using an alkaline eluent. Paclitaxel was used as internal standard. Positive ionization electrospray tandem mass spectrometry was performed for selective and sensitive detection. The method was validated according to the FDA guidelines on bioanalytical method validation. The validated range for docetaxel was from 0.25,1000 ng/mL using 200 µL plasma aliquots. The method requires only a limited volume (200 µL) of human plasma and the method can be applied in studies requiring a low lower limit of quantitation of 0.25 ng/mL. The assay was applied successfully in several clinical and pharmacological studies with docetaxel. Copyright © 2004 John Wiley & Sons, Ltd. [source]


    Sensitivity improvement of circular dichroism detection in HPLC by using a low-pass electronic noise filter: Application to the enantiomeric determination purity of a basic drug

    CHIRALITY, Issue 2 2007
    Marie Lorin
    Abstract The quality control of chiral drugs requires the determination of their enantiomeric purity. Nowadays, circular dichroism (CD) spectroscopy is gaining increasing importance in pharmaceutical analysis because of the commercially available CD detector in liquid chromatography. The separation of the two enantiomers of a basic drug (efaroxan) was achieved by high performance liquid chromatography using an amylose-derivated column with both UV and CD detections. A baseline-resolved separation (resolution: 5) was obtained after optimization of the mobile phase composition with hexane-ethanol-diethylamine (90:10:0.05; v/v/v). The use of a commercial low-pass electronic noise filter of the CD signal has improved the signal-to-noise ratio by a factor twelve and allowed the quantitation of each enantiomer in the 1.25,300 ,g ml,1 concentration range. The CD linear calibration curve, expressed in terms of stereoisomer height ratio versus concentration ratio, was plotted over the 0.4,6% range. A correlation coefficient greater than 0.999 was obtained by least-squares regression and the limit of detection for the distomer/eutomer ratio was estimated at 0.14%. Although the method validation showed good repeatability on the retention times (RSD < 0.9%), on the peak height ratios (RSD < 8.7%) of each enantiomer only up to 99.2% enantiomeric purity was achieved. Chirality, 2006. © 2006 Wiley-Liss, Inc. [source]


    Enantioselective LC/MS method for the determination of an antimalarial agent Fenozan B07 in dog plasma

    CHIRALITY, Issue 5 2006
    Ciriaco Maraschiello
    Abstract A chiral liquid chromatography/mass spectrometry (LC/MS) bioanalytical procedure has been developed for the analysis of the antimalaric agent Fenozan B07 in dog plasma. Normal-phase chromatography involving a phenylcarbamate derivative of cellulose coated on silica gel as the chiral stationary phase was used to resolve (,)-(S,S)-B07 from (+)-(R,R)-B07. The enantiomers were detected by a mass spectrometer equipped with an atmospheric pressure chemical ionization (APCI) interface operated in the negative ion mode. A mass spectrum, characterized by a base peak of m/z 285, was obtained for each enantiomer. The m/z 285 ion was very specific for the analysis of both enantiomers in the plasma. The selected ion monitoring analysis of the plasma samples was therefore performed at m/z 285 for quantitative purposes. The enantiomers were extracted from the plasma in a basic medium and purified by solid-phase extraction using a hydrophilic,lipophilic balanced sorbent. A lower limit of quantification of 2 ng/mL in plasma was achieved for both enantiomers. The quantitative procedure reported in this study was highly specific and sensitive, and was validated according to the FDA guidance on bioanalytical method validation. Chirality, 2006. © 2006 Wiley-Liss, Inc. [source]