Method Detection Limit (method + detection_limit)

Distribution by Scientific Domains


Selected Abstracts


Direct Current Plasma Emission Spectrometric Determination of Major, Minor and Trace Elements in Microwave Oven Acid Leachates of Powdered Whole Coal Samples

GEOSTANDARDS & GEOANALYTICAL RESEARCH, Issue 1 2005
Sandro Fadda
DCP-AES; échantillons de charbon; four à micro-ondes; éléments facilement ionisables; effets de matrice. Major concentrations of Al2O3, Fe2O3, MgO, CaO, Na2O and K2O, minor levels of TiO2, P2O5 and thirty petrologically, geochemically and environmentally significant trace elements have been determined in microwave oven acid leachates of whole powdered coal samples by direct current plasma-atomic emission spectrometry (DCP-AES). A single sample preparation procedure was suitable for all the determinations with no additional dilution step for major elements solution. Dried samples (0.5 g) were treated in low-pressure PFA digestion vessels with HF/HCl/HNO3/HClO4 acids to quantitatively extract the analytes from the bulk material, while leaving the major part of organic matrix as a residue. The major constituents of geological samples, in particular the easily ionised elements (EIEs) such as alkali and alkaline earths, may complicate the instrumental determinations in DCP-AES because of differential enhancements of elemental emission intensities and stray light interferences. Taking account of these factors, the coal matrix is considered to have very low major oxide totals as compared to many other common geo-environmental and related materials (rocks, sediments, soil, ashes etc.). The sample size employed here, while yielding a relatively concentrated solution to cover a wide range of elemental determinations, provided a sample matrix that significantly diminished interferences for DCP measurements. The need for closely matching the unknowns and calibrators was eliminated except for overall acidity and an excess quantity of caesium for EIE buffering. Calibration of the spectrometer was accomplished by simple aqueous single element solutions as high concentration calibrators in addition to a reagent blank as a low concentration calibrator. Two point working curves were established to allow for the maximum concentrations of each element expected in the unknowns. The precision of determinations under routine conditions as well as the reproducibility of the leaching and precision of instrumental measurements have been evaluated. Relative standard deviations (RSD) were of 1,2% for those elements whose concentrations in solid samples were well above the limits of quantification. Method detection limits in the buffered solutions were also evaluated. To evaluate the accuracy of the microwave oven-DCP method a suite of eight certified coal reference materials of differing rank, were analysed with good agreement with the certified and/or available published data. Results are presented for the uncertified major oxides in the AR series reference materials. Les concentrations en éléments majeurs: Al2O3, Fe2O3, MgO, CaO, Na2O et K2O, en éléments mineurs TiO2, P2O5 et en 30 éléments en trace dont le comportement est important en Pétrologie, en Géochimie et en Environnement, ont été analysées par spectrométrie d'émission atomique à plasma à courant direct (DCP-AES), dans des lessivages acides effectués dans un four à micro-ondes sur des échantillons de charbon mis en poudre. Ce mode préparatoire unique est adaptéà toutes les déterminations sans qu'il soit nécessaire d'effectuer une dilution supplémentaire pour l'analyse des éléments majeurs. Les échantillons préalablement desséchés (0.5 g) sont traités dans les pots de PFA de basse pression, avec un mélange d'acides HF/HCl/HNO3/HClO4, afin d'extraire quantitativement les analytes du matériel géologique, tout en laissant la plus grande part de la matrice organique sous forme résiduelle. Les constituants majeurs de ces échantillons géologiques, en particulier les éléments facilement ionisables (EIEs) tels que les alcalins et les alcalino-terreux, peuvent compliquer l'analyse en DCP-AES à cause des rendements variables des intensités d'émission élémentaires et des interférences de raies de lumière. Mais là dessus, la matrice de charbon se révèle être bien plus pauvre en oxydes majeurs que les autres matériaux géologiques, environnementaux ou de type proche (roches, sédiments, sols, cendres). La taille d'échantillon retenue ici, tout en fournissant une solution relativement concentrée qui permet la détermination de beaucoup d'éléments, fournit une matrice qui diminue significativement les interférences lors de la mesure par DCP-AES. Le besoin d'avoir les solutions d'échantillons et les solutions de calibration avec des matrices très proches est donc éliminé, mis à part pour l'acidité totale et la quantité excessive de Césium pour tamponner les EIE. La calibration du spectromètre est faite avec des solutions mono- élémentaires aqueuses, pour déterminer les points de concentrations élevées et avec le blanc de réactifs pour le point de concentration basse. Les courbes de calibrations sont déterminées avec 2 points, pour autoriser l'analyse de concentrations maximales pour chaque élément dans les échantillons inconnus. La précision des déterminations en conditions de routine ainsi que la reproductibilité de l'opération de lessivage et la précision instrumentale des analyses ont étéévaluées. Les déviations standards relatives (RSD) sont de 1,2% pour tout élément dont les concentrations dans le solide sont au dessus des limites de quantification. Les limites de détection de la méthode dans les solutions tamponnées ont aussi étéévaluées. Enfin, pour évaluer la justesse de cette méthode "micro-ondes - DCP" huit charbons certifiés matériaux de référence de différents types ont été analysés, et sont en bon accord avec les données certifiées ou seulement disponibles publiées. Les données sur un certain nombre d'oxydes d'éléments majeurs actuellement non certifiés sont présentées pour les matériaux de référence AR. [source]


Development of a multiresidue method for analysis of major Fusarium mycotoxins in corn meal using liquid chromatography/tandem mass spectrometry

RAPID COMMUNICATIONS IN MASS SPECTROMETRY, Issue 14 2005
Chiara Cavaliere
A sensitive and reliable liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) method has been developed to determine, in a single run, eight trichothecenes, three fumonisins, zearalenone and , -zearalenol, in corn meal samples. LC and MS conditions were varied to find the best compromise in terms of sensitivity and separation. An acceptable compromise was obtained using a C18 column thermostatted at 45°C and a mobile phase gradient of methanol/water with 10,mmol/L formate buffer (pH 3.8). A multiple reaction monitoring program, in which fumonisins and trichothecenes (except nivalenol and deoxynivalenol) are acquired in positive ESI as [M+H]+ or [M+NH4]+, and all other compounds in negative ESI, was developed to match appropriate retention time windows. Sample preparation used a simple homogenization of the corn meal sample with acetonitrile/water (75:25, v/v) followed by extraction on a C18 cartridge and clean-up on a cartridge containing graphitized carbon black. Method detection limits were in the range 2,14,ng/g, with the exception of nivalenol (27,ng/g), deoxynivalenol (40,ng/g) and 15-acetyldeoxynivalenol (30,ng/g). Good accuracy (recoveries 81,104%) and precision (RSD 4,11%) were obtained by performing calibration using a spiked analyte-free extract. Copyright © 2005 John Wiley & Sons, Ltd. [source]


Determination of atrazine, deethylatrazine and simazine in water at parts-per-trillion levels using solid-phase extraction and gas chromatography/ion trap mass spectrometry

RAPID COMMUNICATIONS IN MASS SPECTROMETRY, Issue 24 2003
W. T. Ma
Methods for trace analysis of atrazine and simazine in water have been developed by using stable-isotope dilution with detection by gas chromatography/mass spectrometry. D5 -Atrazine was used as the internal standard for the determination of atrazine and deethylatrazine, while 13C3 -simazine was used for simazine analysis. Water samples were fortified with known amounts of the internal standards and submitted to solid-phase extraction with a C18 bonded-silica cartridge. A gas chromatograph coupled with an ion-trap mass spectrometer was used to analyze the water sample extracts. Method detection limits were 38 parts-per-trillion (ppt) for atrazine and deethylatrazine and 75 ppt for simazine. The accuracy of the method, represented by relative analytical errors, was less than 15%, and the method precision was less than 5% (relative standard deviation, n,=,9). The method was successfully applied to analyze surface water samples collected from a reservoir and a river at ppt levels. Copyright © 2003 John Wiley & Sons, Ltd. [source]


Organic carbon biostimulates rapid rhizodegradation of perchlorate

ENVIRONMENTAL TOXICOLOGY & CHEMISTRY, Issue 12 2008
Dawit D. Yifru
Abstract Previous hydroponics and field studies identified phytodegradation and rhizodegradation as the two main mechanisms by which plants metabolize perchlorate. Plant uptake and phytodegradation of perchlorate is a slower and undesired process that poses ecological risks resulting from phytoaccumulation of some fraction of the perchlorate. Meanwhile, rhizodegradation is a more rapid and favored process involving perchlorate-degrading bacteria utilizing dissolved organic carbon (DOC) as a carbon and energy (electron) source to rapidly degrade perchlorate to innocuous chloride. In the present study, rhizodegradation of perchlorate by willow trees (Salix nigra) was biostimulated using electron sources obtained from natural and artificial carbon sources. In bioreactors provided with carbon sources as 500 mg/L DOC, 25 to 40 mg/L of initial perchlorate concentrations were removed to below the ion chromatography method detection limit of 2 ,g/L in approximately 9 d. For planted controls provided with no electron donors, the time required for the complete removal of the same doses of perchlorate was up to 70 d. Enhancement of rhizodegradation by organic carbon reduced the phytoaccumulated fraction of perchlorate by an order of magnitude from approximately 430 to 20 mg/ kg. The implication of the present study is that the high fraction uptake and phytoaccumulation of perchlorate in agricultural products and the recycling of perchlorate into the ecosystem can be significantly curtailed by supplying electron donors derived from organic carbon sources to the root zone of plants. [source]


Combined Treatment of Perchlorate and RDX in Ground Water Using a Fluidized Bed Reactor

GROUND WATER MONITORING & REMEDIATION, Issue 3 2007
Mark E. Fuller
A bench-scale study was conducted to assess the effectiveness of biological treatment of comingled perchlorate and hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) in ground water using fluidized bed reactors (FBRs). In addition, the ability of FBRs to treat low concentrations of perchlorate was examined. Pilot-scale FBRs were fed either acetic acid or molasses as an electron donor to facilitate simultaneous perchlorate and RDX reduction. The acetic acid-fed FBR consistently removed perchlorate from an influent level of 100 ,g/L to below 6 ,g/L, and values below the method detection limit of 1 ,g/L occurred approximately 70% of the time. RDX breakthrough from all FBRs was minimal due to sorption of the explosive on the granulated activated carbon media, but mass balance calculations indicated that more than 99.5% of the total RDX entering the acetic acid-fed FBR was biologically degraded. Approximately 80% of the RDX fed to the control FBR (i.e., no substrate addition) was accounted for at the end of the study; the remainder was assumed to have been degraded. Molasses was much less effective than acetic acid as an electron donor for treatment of perchlorate and RDX. This work demonstrates that combined treatment of perchlorate and RDX is feasible using FBR technology, and that very low levels of perchlorate (less than 100 ,g/L) can be effectively treated in an FBR. [source]


Behaviour of carbamate pesticides in gas chromatography and their determination with solid-phase extraction and solid-phase microextraction as preconcentration steps

JOURNAL OF SEPARATION SCIENCE, JSS, Issue 16 2005
Rita Carabias-Martínez
Abstract This work reports a study of the chromatographic behaviour of seven carbamate pesticides (aldicarb, carbetamide, propoxur, carbofuran, carbaryl, methiocarb, and pirimicarb) by gas chromatography-mass spectrometry (GC-MS). Variables such as injector temperature, solvent, injection mode, and the degree of ageing of the chromatographic column were studied. One of the aims of this work was to achieve a controlled decomposition of carbamates by a solid-phase microextraction (SPME) preconcentration step with a polyacrylate fibre in order to obtain reproducible chromatographic signals of the degradation products. Optimisation of the SPME process was accomplished by means of experimental design. Several methods using ultrapure water were developed with different preconcentration configurations: SPME-GC-MS, SPE followed by SPME-GC-MS, and SPE plus GC-MS. For all the pesticides studied, method detection limit (MDL) values below 0.1 ,g L,1 were reached in at least one of the proposed configurations. [source]


Determination of urine melamine by validated isotopic ultra-performance liquid chromatography/tandem mass spectrometry

RAPID COMMUNICATIONS IN MASS SPECTROMETRY, Issue 12 2009
Wei-Chih Cheng
Little is known about melamine (MEL) analysis in children's urine. In this study, an isotopic ultra-performance liquid chromatography/tandem mass spectrometry (UPLC/MS/MS) method was developed and systematically validated for the analysis of MEL in urine. The method is easily performed and comprises acidification, solid-phase extraction (SPE) and UPLC/MS/MS analysis. 13C3N3(15NH2)3 was used as the internal standard (IS) for calibration. Transition ions m/z 127,>,85 of MEL and m/z 133,>,89 of the IS were used for quantification and m/z 127,>,68 of MEL was used for quantitative confirmation. Recovery and precision were assessed to guarantee the applicability of the method. The limit of quantification (LOQ) was 0.01,µg/mL while the calculated method detection limit was 0.006,µg/mL. The mean recoveries ranged from 96,99%. The method was then applied to analyze urine samples from children who had potentially consumed MEL-tainted dairy products during screening in Taiwan. Ten nephrolithiasis cases and 20 age- and gender-matched controls were selected for this study. Three out of the 10 nephrolithiasis cases had elevated levels of MEL. Comparatively, twenty age- and gender-matched non-nephrolithiasis controls consuming Taiwan brand milk powder all showed MEL levels lower than the detection limit except for two children with background levels of 0.02,µg/mL. The background level in these children urine samples was established by UPLC/MS/MS analysis. Positive results of urine MEL tests might be associated with nephrolithiasis in these candidates. Measurement of urine MEL concentration can be helpful in confirming MEL-related nephrolithiasis, but its clinical application needs further clarification. Copyright © 2009 John Wiley & Sons, Ltd. [source]


Assessing exposure of sediment biota to organic contaminants by thin-film solid phase extraction

ENVIRONMENTAL TOXICOLOGY & CHEMISTRY, Issue 2 2009
Lizanne M. Meloche
Abstract Differences in bioavailability among sediments are a source of variability and uncertainty in sediment quality assessment. We present three sets of studies designed to test a thin-film solid phase extraction technique for characterizing the bioavailability of organic chemicals in sediments. Laboratory studies with spiked natural sediments reveal highly reproducible thin-film extractions for chemicals with octanol,water partition coefficients between 104.5 and 108.5, with 95% equilibration times between 1 and 600 h. Studies with field-collected sediments illustrate that method detection limits are sufficiently low for field application at contaminated sites. Bioaccumulation studies with clams (Macoma balthica) show excellent correlations between thin-film and animal tissue concentrations. We conclude that thin-film extraction provides an ecologically relevant, fugacity-based measure of chemical exposure that can be expected to improve sediment quality assessments. [source]


Covalently linked immunomagnetic separation/adenosine triphosphate technique (Cov-IMS/ATP) enables rapid, in-field detection and quantification of Escherichia coli and Enterococcus spp. in freshwater and marine environments

JOURNAL OF APPLIED MICROBIOLOGY, Issue 1 2010
C.M. Lee
Abstract Aims:, Developing a rapid method for detection of faecal pollution is among the critical goals set forth by the Environmental Protection Agency in its revision of water quality criteria. The purpose of this study is to devise and test covalently linked antibody,bead complexes for faecal indicator bacteria (FIB), specifically Escherichia coli or Enterococcus spp., in measuring water quality in freshwater and marine systems. Methods and Results:, Covalently linked complexes were 58,89% more robust than antibody,bead complexes used in previous studies. Freshwater and marine water samples analysed using covalently linked immunomagnetic separation/adenosine triphosphate quantification technique (Cov-IMS/ATP) and culture-based methods yielded good correlations for E. coli (R = 0·87) and Enterococcus spp. (R = 0·94), with method detection limits below EPA recreational water quality health standards for single standard exceedances (E. coli, 38 cells per 100 ml; Enterococcus spp. , 25 cells per 100 ml). Cov-IMS/ATP correctly classified 87% of E. coli and 94% of Enterococcus spp. samples based on these water quality standards. Cov-IMS/ATP was also used as a field method to rapidly distinguish differential loading of E. coli between two stream channels to their confluence. Conclusions:, Cov-IMS/ATP is a robust, in-field detection method for determining water quality of both fresh and marine water systems as well as differential loading of FIB from two converging channels. Significance and Impact of the Study:, To our knowledge, this is the first work to present a viable rapid, in-field assay for measuring FIB concentrations in marine water environments. Cov-IMS/ATP is a potential alternative detection method, particularly in areas with limited laboratory support and resources, because of its increased economy and portability. [source]


A new approach to determine method detection limits for compound-specific isotope analysis of volatile organic compounds

RAPID COMMUNICATIONS IN MASS SPECTROMETRY, Issue 24 2006
Maik A. Jochmann
Compound-specific isotope analysis (CSIA) has been established as a useful tool in the field of environmental science, in particular in the assessment of contaminated sites. What limits the use of gas chromatography/isotope ratio mass spectrometry (GC/IRMS) is the low sensitivity of the method compared with GC/MS analysis; however, the development of suitable extraction and enrichment techniques for important groundwater contaminants will extend the fields of application for GC/IRMS. So far, purge and trap (P&T) is the most effective, known preconcentration technique for on-line CSIA with the lowest reported method detection limits (MDLs in the low,µg/L range). With the goal of improving the sensitivity of a fully automated GC/IRMS analysis method, a commercially available P&T system was modified. The method was evaluated for ten monoaromatic compounds (benzene, toluene, para -xylene, ethylbenzene, propylbenzene, isopropylbenzene, 1,2,3-trimethylbenzene, 1,2,4-trimethylbenzene, 1,3,5-trimethylbenzene, fluorobenzene) and ten halogenated volatile organic compounds (VOCs) (dichloromethane, cis -1,2-dichloroethene, trans -1,2-dichloroethene, carbon tetrachloride, chloroform, 1,2-dichloroethane, trichloroethene, tetrachlorethene, 1,2-dibromoethane, bromoform). The influence of method parameters, including purge gas flow rates and purge times, on ,13C values of target compounds was evaluated. The P&T method showed good reproducibility, high linearity and small isotopic fractionation. MDLs were determined by consecutive calculation of the ,13C mean values. The last concentration for which the ,13C value was within this iterative interval and for which the standard deviation was lower than ±0.5, for triplicate measurements was defined as the MDL. MDLs for monoaromatic compounds between 0.07 and 0.35,µg/L are the lowest values reported so far for continuous-flow isotope ratio measurements using an automated system. MDLs for halogenated hydrocarbons were between 0.76 and 27,µg/L. The environmental applicability of the P&T-GC/IRMS method in the low-µg/L range was demonstrated in a case study on groundwater samples from a former military air field contaminated with VOCs. Copyright © 2006 John Wiley & Sons, Ltd. [source]