MRI Applications (mri + application)

Distribution by Scientific Domains


Selected Abstracts


Cover Picture: Synthesis of Gadolinium-Labeled Shell-Crosslinked Nanoparticles for Magnetic Resonance Imaging Applications (Adv. Funct.

ADVANCED FUNCTIONAL MATERIALS, Issue 8 2005
Mater.
Abstract Robust, amphiphilic core,shell nanoparticles that are selectively labeled with gadolinium in the hydrophilic and water-swollen shell layer are depicted in the cover picture. These well-defined nanostructured materials exhibit high relaxivity, a large loading capacity, and are based upon a biocompatible platform for ultimate function in magnetic resonance imaging (MRI) applications, as reported by Wooley and co-workers on p.,1248. Shell-crosslinked knedel-like nanoparticles (SCKs; "knedel" is a Polish term for dumplings) were derivatized with gadolinium chelates and studied as robust magnetic-resonance-imaging-active structures with hydrodynamic diameters of 40,±,3,nm. SCKs possessing an amphiphilic core,shell morphology were produced from the aqueous assembly of diblock copolymers of poly-(acrylic acid) (PAA) and poly(methyl acrylate) (PMA), PAA52,b,PMA128, and subsequent covalent crosslinking by amidation upon reaction with 2,2,-(ethylenedioxy)bis(ethylamine) throughout the shell layer. The properties of these materials, including non-toxicity towards mammalian cells, non-immunogenicity within mice, and capability for polyvalent targeting, make them ideal candidates for utilization within biological systems. The synthesis of SCKs derivatized with GdIII and designed for potential use as a unique nanometer-scale contrast agent for MRI applications is described herein. Utilization of an amino-functionalized diethylenetriaminepentaacetic acid,Gd analogue allowed for direct covalent conjugation throughout the hydrophilic shell layer of the SCKs and served to increase the rotational correlation lifetime of the Gd. In addition, the highly hydrated nature of the shell layer in which the Gd was located allowed for rapid water exchange; thus, the resulting material demonstrated large ionic relaxivities (39,s,1,mM,1) in an applied magnetic field of 0.47,T at 40,°C and, as a result of the large loading capacity of the material, also demonstrated high molecular relaxivities (20,000,s,1,mM,1). [source]


Ground truth hardware phantoms for validation of diffusion-weighted MRI applications

JOURNAL OF MAGNETIC RESONANCE IMAGING, Issue 2 2010
Pim Pullens MSc
Abstract Purpose: To quantitatively validate diffusion-weighted MRI (DW-MRI) applications, a hardware phantom containing crossing fibers at a sub-voxel level is presented. It is suitable for validation of a large spectrum of DW-MRI applications from acquisition to fiber tracking, which is an important recurrent issue in the field. Materials and Methods: Phantom properties were optimized to resemble properties of human white matter in terms of anisotropy, fractional anisotropy, and T2. Sub-voxel crossings were constructed at angles of 30, 50, and 65 degrees, by wrapping polyester fibers, with a diameter close to axon diameter, into heat shrink tubes. We show our phantoms are suitable for the acquisition of DW-MRI data using a clinical protocol. Results: The phantoms can be used to succesfully estimate both the diffusion tensor and non-Gaussian diffusion models, and perform streamline fiber tracking. DOT (Diffusion Orientation Transform) and q-ball reconstruction of the diffusion profiles acquired at b = 3000 s/mm2 and 132 diffusion directions reveal multimodal diffusion profiles in voxels containing crossing yarn strands. Conclusion: The highly purpose adaptable phantoms provide a DW-MRI validation platform: applications include optimisation of acquisition schemes, validation of non-Gaussian diffusion models, comparison and validation of fiber tracking algorithms, and quality control in multi-center DWI studies. J. Magn. Reson. Imaging 2010;32:482,488. © 2010 Wiley-Liss, Inc. [source]


Application of k -space energy spectrum analysis for inherent and dynamic B0 mapping and deblurring in spiral imaging

MAGNETIC RESONANCE IN MEDICINE, Issue 4 2010
Trong-Kha Truong
Abstract Spiral imaging is vulnerable to spatial and temporal variations of the amplitude of the static magnetic field (B0) caused by susceptibility effects, eddy currents, chemical shifts, subject motion, physiological noise, and system instabilities, resulting in image blurring. Here, a novel off-resonance correction method is proposed to address these issues. A k -space energy spectrum analysis algorithm is first applied to inherently and dynamically generate a B0 map from the k -space data at each time point, without requiring any additional data acquisition, pulse sequence modification, or phase unwrapping. A simulated phase evolution rewinding algorithm and an automatic residual deblurring algorithm are then used to correct for the blurring caused by both spatial and temporal B0 variations, resulting in a high spatial and temporal fidelity. This method is validated against conventional B0 mapping and deblurring methods, and its advantages for dynamic MRI applications are demonstrated in functional MRI studies. Magn Reson Med, 2010. © 2010 Wiley-Liss, Inc. [source]


Sensitivity-encoded coronary MRA at 3T

MAGNETIC RESONANCE IN MEDICINE, Issue 2 2004
Michael E. Huber
Abstract Long scan times are still a main limitation in free-breathing navigator-gated 3D coronary MR angiography (MRA). Unlike other MRI applications, high-resolution coronary MRA has not been amenable to acceleration by parallel imaging techniques due to signal-to-noise ratio (SNR) concerns. In the present work, mitigating SNR limitations by the transition to higher static magnetic field strength is proposed, thus enabling scan time reduction by the parallel sensitivity encoding (SENSE) technique. The study reports the implementation and evaluation of free-breathing navigator-gated 3D coronary MRA with SENSE at 3T. Results from 11 healthy subjects indicate that the approach permits significant scan time reduction in MRA of the left and right coronary systems. Quantitative image analysis and visual grading suggest that two-fold scan acceleration can be accomplished at nearly preserved image quality. The additional experiments appear to demonstrate that parallel MRA equally permits enhancing volume coverage and spatial resolution while maintaining scan time. Magn Reson Med 52:221,227, 2004. © 2004 Wiley-Liss, Inc. [source]