Leads I (lead + i)

Distribution by Scientific Domains


Selected Abstracts


Electrophysiologic and electrocardiographic characteristics of focal atrial tachycardia arising from superior tricuspid annulus

INTERNATIONAL JOURNAL OF CLINICAL PRACTICE, Issue 7 2008
J. X. Yin
Summary Objectives:, This study describes the electrophysiologic and electrocardiographic characteristics of focal atrial tachycardia (AT) arising from superior tricuspid annulus in six (1.9%) patients of a consecutive series of 320 patients. Methods:, Six patients (mean age 42 ± 22 years) with a mean cycle length of 326 ms of a consecutive series of 320 patients undergoing radiofrequency ablation for focal AT were mapped. Results:, During electrophysiologic study, tachycardia could be induced in five patients with programmed atrial extrastimuli while a spontaneous onset and offset with ,warm-up and cool-down' phenomenon was seen in the other patient. During tachycardia, P-wave morphology in Lead I, II, III and aVF was upright in all the six patients. The precordial leads were dominantly negative or isoelectric in V1,V2 and positive in V5,V6 with a transition at V3 or V4. Moreover, the tachycardia was sensitive to intravenous administration of adenosine triphosphate in five of six patients. Conclusions:, Radiofrequency ablation was performed successfully in all patients (mean 4.5 ± 1.2 applications). No recurrence of AT was observed after a mean follow-up of 8 ± 6 months. Thus, AT arising from superior tricuspid annulus is rare. Radiofrequency ablation of this kind of AT is safe and effective. [source]


Use of an Intracardiac Electrogram Eliminates the Need for a Surface ECG during Implantable Cardioverter-Defibrillator Follow-Up

PACING AND CLINICAL ELECTROPHYSIOLOGY, Issue 12 2007
KEVIN A. MICHAEL M.B.Ch.B.
Background:A surface electrocardiogram (SECG) for pacing threshold measurements during routine implantable cardioverter-defibrillator (ICD) follow-up can be cumbersome. This study evaluated the use of an intrathoracic far-field electrogram (EGM) derived between the Can and superior vena cava (SVC) electrode,the Leadless electrocardiogram (LLECG), in dual chamber ICDs in performing pacing threshold tests. Methods:The LLECG was evaluated prospectively during atrial and ventricular pacing threshold testing as a substudy of the Comparison of Empiric to Physician-Tailored Programming of Implantable Cardioverter-Defibrillators trial (EMPIRIC) in which dual chamber ICDs were implanted in 888 patients. Threshold tests were conducted at 1 volt by decrementing the pulse width. Follow-up at three months compared pacing thresholds measured using LLECG with those using Lead I of the surface ECG (SECG). The timesaving afforded by LLECG was assessed by a questionnaire. Results:The median threshold difference between LLECG and SECG measurements for both atrial (0.00 ms, P = 0.90) and ventricular (0.00 ms, P = 0.34) threshold tests were not significant. Ninety percent of atrial and ventricular threshold differences were bounded by ± 0.10 ms and ,0.10 to +0.04 ms, respectively. We found that 99% of atrial and ventricular thresholds tests at six and 12 months attempted using LLECG were successfully completed. The questionnaire indicated that 65% of healthcare professionals found LLECG to afford at least some timesaving during device follow-ups. Conclusion:Routine follow-up can be performed reliably and expeditiously in dual chamber Medtronic (Minneapolis, MN, USA) ICDs using LLECG alone, resulting in overall timesaving. [source]


ECG Leads I and II to Evaluate Diuresis of Patients with Congestive Heart Failure Admitted to the Hospital via the Emergency Department

PACING AND CLINICAL ELECTROPHYSIOLOGY, Issue 1 2009
SUTHAPORN LUMLERTGUL M.D.
Background: Attenuation of electrocardiogram (ECG) QRS complexes is observed in patients with a variety of illnesses and peripheral edema (PERED), and augmentation with alleviation of PERED. Serial ECGs in stable individuals display variation in the amplitude of QRS complexes in leads V1,V6, stemming from careless placement of recording electrodes on the chestwall. Electrocardiographs record only leads I and II, and mathematically derive the other four limb leads in real time. This study evaluated the sum of the amplitudes of ECG leads I and II, along with other sets of ECG leads in the monitoring of diuresis in patients with congestive heart failure (CHF). Methods: Twenty patients with CHF had ECGs and weights recorded on admission and at discharge. The amplitude of the QRS complexes in all ECG leads were measured and sums of I and II, all limb leads, V1,V6, and all 12 leads were calculated. Results: There was a good correlation between the weight loss and the increase in the sums of the amplitudes of the QRS complexes from leads I and II (r = 0.55, P = 0.012), and the six limb leads (r = 0.68, P = 0.001), but a poor correlation with the V1,V6 leads (r = 0.04, P = 0.85) and all 12 leads (r = 0.1, P = 0.40). Conclusions: Sums of the amplitudes of the ECG QRS complexes from leads I and II constitute a reliable, easily obtainable, ubiquitously available, bedside clinical index, which can be employed in the diagnosis, monitoring of management, and follow-up of patients with CHF. [source]


The Surface Electrocardiogram Predicts Risk of Heart Block During Right Heart Catheterization in Patients With Preexisting Left Bundle Branch Block: Implications for the Definition of Complete Left Bundle Branch Block

JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, Issue 7 2010
BENZY J. PADANILAM M.D.
LBBB and Heart Block.,Background: Patients with left bundle branch block (LBBB) undergoing right heart catheterization can develop complete heart block (CHB) or right bundle branch block (RBBB) in response to right bundle branch (RBB) trauma. We hypothesized that LBBB patients with an initial r wave (,1 mm) in lead V1 have intact left to right ventricular septal (VS) activation suggesting persistent conduction over the left bundle branch. Trauma to the RBB should result in RBBB pattern rather than CHB in such patients. Methods: Between January 2002 and February 2007, we prospectively evaluated 27 consecutive patients with LBBB developing either CHB or RBBB during right heart catheterization. The prevalence of an r wave ,1 mm in lead V1 was determined using 118 serial LBBB electrocardiographs (ECGs) from our hospital database. Results: Catheter trauma to the RBB resulted in CHB in 18 patients and RBBB in 9 patients. All 6 patients with ,1 mm r wave in V1 developed RBBB. Among these 6 patients q wave in lead I, V5, or V6 were present in 3. Four patients (3 in CHB group and 1 in RBBB group) developed spontaneous CHB during a median follow-up of 61 months. V1 q wave ,1 mm was present in 28% of hospitalized complete LBBB patients. Conclusions: An initial r wave of ,1 mm in lead V1 suggests intact left to right VS activation and identifies LBBB patients at low risk of CHB during right heart catheterization. These preliminary findings indicate that an initial r wave of ,1 mm in lead V1, present in approximately 28% of ECGs with classically defined LBBB, may constitute a new exclusion criterion when defining complete LBBB. (J Cardiovasc Electrophysiol, Vol. pp. 781-785, July 2010) [source]


Idiopathic Left Ventricular Arrhythmias Originating Adjacent to the Left Aortic Sinus of Valsalva: Electrophysiological Rationale for the Surface Electrocardiogram

JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, Issue 2 2010
TAKUMI YAMADA M.D.
IVT Arising Adjacent to the Left Sinus of Valsalva.Background: Idiopathic ventricular arrhythmias (VAs) may be amenable to catheter ablation within or adjacent to the left sinus of Valsalva (LSOV). However, features that discriminate these sites have not been defined. The purpose of this study was to determine the electrocardiographic and electrophysiological features of VAs originating within or adjacent to the LSOV. Methods and Results: We studied 48 consecutive patients undergoing successful catheter ablation of idiopathic VAs originating from the left coronary cusp (LCC, n = 29), aortomitral continuity (AMC, n = 10) and great cardiac vein or anterior interventricular cardiac vein (Epi, n = 9). A small r wave, or rarely an R wave, was typically observed in lead I during the VAs and pacing in these regions. An S wave in lead V5 or V6 occurred significantly more often during both the VAs and pacing from the AMC than during that from the LCC and Epi (p < 0.05 to 0.0001). For discriminating whether VA origins can be ablated endocardially or epicardially, the maximum deflection index (MDI = the shortest time to the maximum deflection in any precordial lead/QRS duration) was reliable for VAs arising from the AMC (100%), but was less reliable for LCC (73%) and Epi (67%) VAs. In 3 (33%) of the Epi VAs, the site of an excellent pace map was located transmurally opposite to the successful ablation site (LCC = 1 and AMC = 2). Conclusions: The MDI has limited value for discriminating endocardial from epicardial VA origins in sites adjacent to the LSOV probably due to preferential conduction, intramural VA origins or myocardium in contact with the LCC. (J Cardiovasc Electrophysiol, Vol. 21, pp. 170-176, February 2010) [source]


Clinical Implications of QRS Duration and QT Peak Prolongation in Patients with Suspected Coronary Disease Referred for Elective Cardiac Catheterization

ANNALS OF NONINVASIVE ELECTROCARDIOLOGY, Issue 2 2008
M. Nadeem Attar M.D., M.R.C.P.
Background: The electrocardiogram (ECG) remains a simple, universally available, and prognostically powerful investigation in heart failure, and acute coronary syndromes. We sought to assess the prognostic utility of clinical, angiographic, and simple ECG parameters in a large cohort of patients undergoing elective cardiac catheterization (CC) for known or suspected coronary artery disease. Methods: Consecutive consenting patients undergoing CC for coronary disease were enrolled at a single tertiary center. Patient data, drug therapy, catheter reports, and ECG recordings were prospectively recorded in a validated electronic archive. The primary outcome measure was death or nonfatal myocardial infarction (MI) over 1 year or until percutaneous or cardiac surgical intervention. Independent prognostic markers were identified using the Cox proportional hazard model. Results: A total of 682 individuals were recruited of whom 17(2.5%) died or suffered a nonfatal MI in 1 year. In multivariate analysis QRS duration (ms) (HR 1.03 95% CI 1.01,1.05, P = 0.003), extent of coronary disease (HR 2.01 95% CI 1.24,3.58, P = 0.006), and prolonged corrected QT peak interval in lead I (HR 1.02 95% CI 1.00,1.03, P = 0.044) were independently associated with death or nonfatal MI. Receiver-operator characteristic (ROC) analysis for the multivariate model against the primary end point yielded an area under the curve of 0.759 (95% CI 0.660,0.858), P < 0.001. Conclusions: QRS duration and QT peak are independently associated with increased risk of death or nonfatal MI in stable patients attending for coronary angiography. [source]


The Morphology Changes in Limb Leads after Ablation of Verapamil-Sensitive Idiopathic Left Ventricular Tachycardia and Their Correlation with Recurrence

JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, Issue 3 2008
SHU-YUAN YAO Ph.D
Objectives: This study was designed to explore the morphology changes in limb leads of ECGs after successful ablation of verapamil sensitive idiopathic left ventricular tachycardia (ILVT) and their correlation with tachycardia recurrence. Methods: Between January 2001 and December 2006, 116 patients who underwent successful ablation of ILVT were included in the study. Twelve-lead surface ECG recordings during sinus rhythm were obtained in all patients before and after ablation to compare morphology changes in limb leads. Results: The ECG morphology changes after ablation were divided into two categories: one with new or deepening Q wave in inferior leads and/or disappearance of Q wave in leads I and aVL, and the other without change. The changes in any Lead II, III, or aVF after ablation occurred significantly more in patients without recurrence of ventricular tachycardia (VT) (P < 0.0001, 0.002, and 0.0001, respectively). The patients with recurrence of VT tended to have no ECG changes, compared with those without recurrence of VT (P = 0.009). The sensitivity of leads II, III, and aVF changes in predicting nonrecurrence VT were 66.7%, 78.7%, and 79.6%, specificity were 100%, 75%, and 87.5%, and nonrecurrence predictive value of 100%, 97.7%, and 98.9%, respectively. When inferior leads changes were combined, they could predict all nonrecurrence patients with 100% specificity. Conclusions: Successful radiofrequency ablation of ILVT could result in morphology changes in limb leads of ECG, especially in inferior leads. The combined changes in inferior leads can be used as an effective endpoint in ablation of this ILVT. [source]


Electrocardiographic and Electrophysiologic Characteristics of Midseptal Accessory Pathways

JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, Issue 3 2005
SHIH-LING CHANG M.D.
Background: The purpose of the present study was to investigate the electrocardiographic and electrophysiologic characteristics of right midseptal (RMS) and left midseptal (LMS) accessory pathways (APs), and to develop a stepwise algorithm to differentiate RMS from LMS APs. Methods and Results: From May 1989 to February 2004, 1591 patients with AP-mediated tachyarrhythmia underwent RF catheter ablation in this institution, and 38 (2.4%) patients had MS APs. The delta wave and precordial QRS transition during sinus rhythm, retrograde P wave during orthodromic tachycardia, and electrophysiologic characteristic and catheter ablation in 30 patients with RMS APs and 8 patients with LMS APs were analyzed. There was no significant difference in electrophysiologic characteristics and catheter ablation between RMS and LMS APs. The polarity of retrograde P wave during orthodromic tachycardia also showed no statistical difference between patients with RMS and LMS APs. The delta wave polarity was positive in leads I, aVL, and V3 to V6 in patients with RMS and LMS APs. Patients with LMS APs had a higher incidence of biphasic delta wave in lead V1 than patients with RMS APs (80% vs. 15%, P = 0.012). The distributions of precordial QRS transition were different between RMS APs (leads V2; n = 10, V3; n = 7 and V4; n = 3) and LMS APs (leads V1; n = 1 and V2; n = 4) (P = 0.03). The combination of a delta negative wave in lead V1 or precordial QRS transition in lead V3 or V4 had a sensitivity of 90%, specificity of 80%, positive predictive value of 95%, and negative predictive value of 66% in predicting an RMS AP. Conclusions: Delta wave polarity in lead V1 and precordial QRS transition may differentiate RMS and LMS APs. [source]


ECG Leads I and II to Evaluate Diuresis of Patients with Congestive Heart Failure Admitted to the Hospital via the Emergency Department

PACING AND CLINICAL ELECTROPHYSIOLOGY, Issue 1 2009
SUTHAPORN LUMLERTGUL M.D.
Background: Attenuation of electrocardiogram (ECG) QRS complexes is observed in patients with a variety of illnesses and peripheral edema (PERED), and augmentation with alleviation of PERED. Serial ECGs in stable individuals display variation in the amplitude of QRS complexes in leads V1,V6, stemming from careless placement of recording electrodes on the chestwall. Electrocardiographs record only leads I and II, and mathematically derive the other four limb leads in real time. This study evaluated the sum of the amplitudes of ECG leads I and II, along with other sets of ECG leads in the monitoring of diuresis in patients with congestive heart failure (CHF). Methods: Twenty patients with CHF had ECGs and weights recorded on admission and at discharge. The amplitude of the QRS complexes in all ECG leads were measured and sums of I and II, all limb leads, V1,V6, and all 12 leads were calculated. Results: There was a good correlation between the weight loss and the increase in the sums of the amplitudes of the QRS complexes from leads I and II (r = 0.55, P = 0.012), and the six limb leads (r = 0.68, P = 0.001), but a poor correlation with the V1,V6 leads (r = 0.04, P = 0.85) and all 12 leads (r = 0.1, P = 0.40). Conclusions: Sums of the amplitudes of the ECG QRS complexes from leads I and II constitute a reliable, easily obtainable, ubiquitously available, bedside clinical index, which can be employed in the diagnosis, monitoring of management, and follow-up of patients with CHF. [source]


Focal Atrial Fibrillation in Dextrocardia

ANNALS OF NONINVASIVE ELECTROCARDIOLOGY, Issue 3 2009
Takumi Yamada M.D.
A 49-year-old woman with dextrocardia and situs inversus underwent catheter ablation of paroxysmal atrial fibrillation (AF). During the electrophysiologic study, AF triggered by frequent premature atrial contractions (PACs) with a short coupling interval exhibiting a "P on T" pattern occurred. Pulmonary vein mapping revealed that those PACs originated from right-sided (anatomic left) or left-sided (anatomic right) pulmonary veins. In this case with mirror-image dextrocardia, the P-wave morphologies in leads I and aVL and the II/III ratio of the P-wave amplitude were helpful for predicting a right- or left-sided pulmonary vein origin. [source]