Lesion Location (lesion + location)

Distribution by Scientific Domains


Selected Abstracts


Biopsy site selection for endobronchial ultrasound guide-sheath transbronchial biopsy of peripheral lung lesions

INTERNAL MEDICINE JOURNAL, Issue 2 2008
D. I. K. Fielding
Abstract Background: Choice of biopsy method for peripheral lung lesions is usually between CT-guided fine-needle aspiration biopsy (CT FNA) and bronchoscopy. Endobronchial ultrasound guide-sheath biopsy (EBUS GS) is a new method to improve the yield of bronchoscopy. Guidance on which lesions would be appropriate for either method is needed. The aim of the study was to compare the diagnostic yields and pneumothorax rate of EBUS GS and CT FNA in terms of the location of the lesion needing biopsy, in particular, whether the lesion is touching the pleura. Methods: Prospective series of EBUS GS were compared to retrospective review of CT FNA carried out simultaneously in a large teaching hospital. Results: For EBUS GS 140 cases were carried out with mean lesion size 29 mm. Overall diagnostic sensitivity was 66%. For lesions not touching visceral pleura it was 74% compared with 35% where it was on the pleura (P < 0.01). For CT FNA 121 cases were carried out with mean lesion size 37 mm. The overall diagnostic sensitivity was 64%. Rate of pneumothorax and ICC placement in EBUS GS was 1 and 0% and in CTFNA was 28 and 6%, with P < 0.001 for both. Conclusion: Lesion location, in particular, connection to the visceral pleura, can improve decision-making in referral for either CT FNA or EBUS GS to maximize diagnostic yield and minimize pneumothorax rate. [source]


Dermoscopy provides useful information for the management of melanonychia striata

DERMATOLOGIC THERAPY, Issue 1 2007
Luc Thomas
ABSTRACT:, The diagnosis of melanonychia striata is often difficult, and a biopsy of the nail matrix is required in doubtful cases. However, dermoscopic examination of the nail plate offers interesting information in order to better select the cases in which pathologic examination is indicated. In the case of brown longitudinal pigmentation with parallel regular lines, the diagnosis of nail apparatus melanocytic nevus could be made. On the other hand, the presence of a brown pigmentation overlaid by longitudinal lines irregular in their thickness, spacing, color, or parallelism is highly in favor of a melanoma. Gray homogeneous lines are observed in case of lentigo, lentiginoses, ethnic or drug-induced pigmentations, and in post-traumatic pigmentations. Blood spots are characterized by their round-shaped proximal edge and their filamentous distal edge and are highly suggestive of subungual hemorrhages. Dermoscopic examination of the free edge of the nail plate gives information on the lesion location; pigmentation of the dorsum of the nail plate is in favor of a proximal nail matrix lesion, whereas pigmentation the lower part of the nail edge is in favor of a lesion of the distal matrix. [source]


Accuracy and reproducibility of manual and semiautomated quantification of MS lesions by MRI

JOURNAL OF MAGNETIC RESONANCE IMAGING, Issue 3 2003
Edward A. Ashton PhD
Abstract Purpose To evaluate the accuracy, reproducibility, and speed of two semiautomated methods for quantifying total white matter lesion burden in multiple sclerosis (MS) patients with respect to manual tracing and to other methods presented in recent literature. Materials and Methods Two methods involving the use of MRI for semiautomated quantification of total lesion burden in MS patients were examined. The first method, geometrically constrained region growth (GEORG), requires user specification of lesion location. The second technique, directed multispectral segmentation (DMSS), requires only the location of a single exemplar lesion. Test data sets included both clinical MS data and MS brain phantoms. Results The mean processing times were 60 minutes for manual tracing, 10 minutes for region growth, and 3 minutes for directed segmentation. Intra- and interoperator coefficients of variation (CVs) were 5.1% and 16.5% for manual tracing, 1.4% and 2.3% for region growth, and 1.5% and 5.2% for directed segmentation. The average deviations from manual tracing were 9% for region growth and 5.7% for directed segmentation. Conclusion Both semiautomated methods were shown to have a significant advantage over manual tracing in terms of speed and precision. The accuracy of both methods was acceptable, given the high variability of the manual results. J. Magn. Reson. Imaging 2003;17:300,308. © 2003 Wiley-Liss, Inc. [source]


A Broad Diagnostic Battery for Bedside Transcranial Doppler to Detect Flow Changes With Internal Carotid Artery Stenosis or Occlusion

JOURNAL OF NEUROIMAGING, Issue 3 2001
Ioannis Christou MD
ABSTRACT Background and Purpose. The authors establish accuracy parameters of a broad diagnostic battery for bedside transcranial Doppler (TCD) to detect flow changes due to internal carotid artery (ICA) stenosis or occlusion. Methods. The authors prospectively studied consecutive patients with stroke or transient ischemic attack referred for TCD. TCD was performed and interpreted at bedside using a standard insonation protocol. A broad diagnostic battery included major criteria: collateral flow signals, abnormal siphon or terminal carotid signals, and delayed systolic flow acceleration in the middle cerebral artery. Minor criteria included a unilateral decrease in pulsatility index (, 0.6 or , 70% of contralateral side), flow diversion signs, and compensatory velocity increase. Angiography or carotid duplex ultrasound (CDU) was used to grade the degree of carotid stenosis using North American criteria. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of TCD findings were determined. Results. Seven hundred and twenty patients underwent TCD, of whom 517 (256 men and 261 women) had angiography and/or CDU within 8.8 ± 0.9 days. Age was 63.1 ± 15.7 years. For a 70% to 99% carotid stenosis or occlusion, TCD had sensitivity of 79.4%, specificity of 86.2%, PPV of 57.0%, NPV of 94.8%, and accuracy of 84.7%. For a 50% to 99% carotid stenosis or occlusion, TCD had sensitivity of 67.5%, specificity of 83.9%, PPV of 54.5%, NPV of 90.0%, and accuracy of 81.6%. TCD detected intracranial carotid lesions with 84.9% accuracy and extracranial carotid lesions with 84.4% accuracy (sensitivity of 88% and 79%, specificity of 85% and 86%, PPV of 24% and 54%, and NPV of 99% and 95%, respectively). The prevalence of the ophthalmic artery flow reversal was 36.4% in patients with , 70% stenosis or occlusion. If present, this finding indicated a proximal ICA lesion location in 97% of these patients. Conclusions. In symptomatic patients, bedside TCD can accurately detect flow changes consistent with hemodynamically significant ICA obstruction; however, TCD should not be a substitute for direct carotid evaluation. Because TCD is sensitive and specific for , 70% carotid stenosis or occlusion in both extracranial and intracranial carotid segments, it can be used as a complementary test to refine other imaging findings and detect tandem lesions. [source]


Electrodiagnostic studies of the facial nerve in peripheral facial palsy and hemifacial spasm,

MUSCLE AND NERVE, Issue 1 2007
Josep Valls-Solé MD
Abstract Electrodiagnostic (EDX) assessment is one of the most important aspects in the evaluation of the two most common disorders of the facial nerve: facial palsy and hemifacial spasm. Facial palsy is usually an acute disorder that resolves in a few weeks but, in a number of cases, leads to a postparalytic facial syndrome featuring muscle synkinesis, myokymia, and involuntary mass contractions of muscles on the affected side. Hemifacial spasm is usually a chronic disorder characterized by paroxysms of involuntary, clonic, and synchronous twitching of all facial muscles on the affected side. EDX studies provide information on lesion location and severity, pathophysiology underlying the two disorders, and differential diagnosis between syndromes presenting with abnormal facial muscle activity. This monograph is intended to describe the most relevant EDX findings in the two disorders and the most appropriate timing for the examinations in order to provide useful information for prognosis and therapeutic decision-making. Muscle Nerve, 2007 [source]


Percutaneous saphenous vein graft intervention with sequential embolic protection devices: Complementing lesion anatomy with embolic protection device

CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, Issue 5 2008
Parker Grow MD
Abstract Saphenous vein graft (SVG) percutaneous coronary intervention (PCI) carries unique technical challenges requiring the utilization of embolic protection devices (EPDs) to reduce the adverse events associated with distal embolization. Distal embolization is a common and almost ubiquitous consequence of SVG PCI due to the soft and friable nature of the SVG lesions. We describe a case of revascularizing a SVG with tandem stenoses employing the use of two different EPDs that complemented their respective lesion's location within the SVG. © 2008 Wiley-Liss, Inc. [source]