Laser Desorption Ionization (laser + desorption_ionization)

Distribution by Scientific Domains

Terms modified by Laser Desorption Ionization

  • laser desorption ionization time-of-flight mass spectrometry

  • Selected Abstracts


    Effect of celecoxib on cyclooxygenase-2 expression and possible variants in a patient with Barrett's esophagus

    DISEASES OF THE ESOPHAGUS, Issue 3 2007
    G. A. Jacobson
    SUMMARY., Cyclooxygenase-2 (COX-2) expression is increased in metaplastic and dysplastic Barrett's esophageal epithelium and it is thought that selective COX-2 inhibitors could offer hope as chemoprevention therapy. The aim of the study was to investigate the in vivo effect of celecoxib on COX-2 expression in patients with Barrett's esophagus and no recent history of non-steroidal anti-inflammatory drug use. Endoscopic mucosal biopsy specimens were collected at baseline and after 28 days of therapy in a patient treated with celecoxib 200 mg twice daily. Samples were analyzed for COX-2 expression by immunoblot analysis with chemiluminescence detection. COX-2 expression was found to decline 20% and 44% at two different biopsy sites compared to the baseline sample. Longer exposures revealed a number of previously unidentified proteins above and below the 67 kDa COX-2 protein including 38 kDa and 45 kDa proteins which were present only at study completion consistent with up-regulation after celecoxib therapy. Further investigations of the 38 kDa and 45 kDa proteins were undertaken using two-dimensional polyacrylamide gel electrophoresis (2D-PAGE) with immunoblot and MALDI-TOF (matrix assisted laser desorption ionization , time of flight) analysis but no matches were found and results were inconclusive. Unmatched masses from MALDI-TOF peptide mass fingerprinting were compared with human COX-2 (67 kDa) and COX-2b (39 kDa) using unspecific cleavage. Peptide sequence homology with COX-2 and COX-2b was found for a length of 19 amino acids. Based on immunodetection, molecular weight and equivical MALDI-TOF results, one of these up-regulated proteins may be COX-2b. [source]


    Formation and reactions of cluster ions from aromatic carboxylic acids together with amino acids

    ISRAEL JOURNAL OF CHEMISTRY, Issue 2 2001
    Anja Meffert
    The cluster formation of several aromatic carboxylic acids, ferulic acid, vanillic acid, sinapinic acid, and 3,4-dihydroxybenzoic acid was investigated by means of laser desorption into a supersonic beam followed by multiphoton ionization-time-of-flight mass spectrometry. The formation of not only homogeneous clusters, but also of heterogeneous clusters with some small amino acids was studied. The different neutral clusters formed in the supersonic expansion were ionized by a multiphoton process employing either nano- or femtosecond laser pulses. Strong differences in the detection of cluster ions due to the laser pulse length employed for multiphoton ionization were observed. Only femtosecond activation led to mass spectra with intense signals of the cluster ions. In addition, in the case of femtosecond ionization, protonated amino acids were detected in the mass spectra. As direct ionization of the free amino acids is not possible under the chosen ionization conditions because they lack an adequate chromophore, these protonated amino acids are assumed to be formed via an intracluster proton transfer in the heterogeneous dimer and subsequent decay of the ionized cluster (dissociative proton transfer). Such well-known processes for heterogeneous clusters consisting of a substituted aromatic molecule and small polar solvent molecules may be involved in the matrixassisted laser desorption ionization (MALDI) process. [source]


    Evaluation of the Photodegradation of Crystal Violet upon Light Exposure by Mass Spectrometric and Spectroscopic Methods

    JOURNAL OF FORENSIC SCIENCES, Issue 2 2009
    Céline Weyermann Dr. rer. nat.
    Abstract:, Crystal violet is a very common dye in ballpoint ink. Recent research suggests that the degradation of triarylmethane dyes gives an indication of the age of a ballpoint pen entry on a document. The main problem for the quantitative evaluation of the degradation is that it is highly dependent on the exposure to light. Moreover additional factors, such as additives and substrate play an important role in this process. The aim of this work is to compare the degradation pathways of the pure dye in water and ethanol upon exposure to xenon light by UV/VIS spectrophotometry and laser desorption ionization. Significant differences have been observed in the products and the kinetics of the degradation. N-demethylation, an expected decomposition process, was found to take place only in aqueous solution and kinetics calculations showed that the degradation occurred 2.5 times faster in ethanol compared to water. The degradation of crystal violet in inks from four ballpoint pens on paper was also studied for entries made over 2,3 years. It was observed that degradation reactions were quenched by the presence of another dye due to competitive absorption. It was also observed that the thickness of a stroke (concentration of ink) influenced the degradation process. In the absence of light only one ballpoint pen showed slight degradation. A better understanding of the influence of the paper, ink composition, and storage conditions is necessary to interpret correctly the age of an ink based on the degradation of dyes. [source]


    Dissociation mechanisms and implication for the presence of multiple conformations for peptide ions with arginine at the C-terminus: time-resolved photodissociation study

    JOURNAL OF MASS SPECTROMETRY (INCORP BIOLOGICAL MASS SPECTROMETRY), Issue 7 2010
    So Hee Yoon
    Abstract Time-resolved photodissociation (PD) patterns of singly protonated peptides with arginine at the C-terminus (C-arg peptide ions) have been used to classify the dissociation channels into two categories, i.e. high-energy channels generating v, w and x and low-energy ones generating b, y and z. x + 1 formed by C,CO cleavage seems to be the intermediate ion in high-energy channels just as a + 1 is for N-arg peptide ions. Difference in time-resolved pattern indicates that the two sets of channels, high- and low-energy ones, are not in direct competition. Noncompetitive dissociation is also indicated by the observation of anomalous effect of matrix used in matrix-assisted laser desorption ionization, a cooler matrix generating more high-energy product ions both in spontaneous dissociation and in PD. Results from detailed investigation suggest that the two sets of channels start from two (or more) different conformations. Copyright © 2010 John Wiley & Sons, Ltd. [source]


    A perspective on MALDI alternatives,total solvent-free analysis and electron transfer dissociation of highly charged ions by laserspray ionization

    JOURNAL OF MASS SPECTROMETRY (INCORP BIOLOGICAL MASS SPECTROMETRY), Issue 5 2010
    Sarah Trimpin
    Abstract Progress in research is hindered by analytical limitations, especially in biological areas in which sensitivity and dynamic range are critical to success. Inherent difficulties of characterization associated with complexity arising from heterogeneity of various materials including topologies (isomeric composition) and insolubility also limit progress. For this reason, we are developing methods for total solvent-free analysis by mass spectrometry consisting of solvent-free ionization followed by solvent-free gas-phase separation. We also recently constructed a novel matrix-assisted laser desorption ionization (MALDI) source that provides a simple, practical and sensitive way of producing highly charged ions by laserspray ionization (LSI) or singly charged ions commonly observed with MALDI by choice of matrix or matrix preparation. This is the first ionization source with such freedom,an extremely powerful analytical ,switch'. Multiply charged LSI ions allow molecules exceeding the mass-to-charge range of the instrument to be observed and permit for the first time electron transfer dissociation fragment ion analysis. Copyright © 2010 John Wiley & Sons, Ltd. [source]


    Metal ion attachment to the matrix meso-tetrakis(pentafluorophenyl)porphyrin, related matrices and analytes: an experimental and theoretical study,

    JOURNAL OF MASS SPECTROMETRY (INCORP BIOLOGICAL MASS SPECTROMETRY), Issue 11 2009
    Jeroen J. A. van Kampen
    Abstract In a previous study [van Kampen et al.Analytical Chemistry 2006; 78: 5403], we found that meso-tetrakis (pentafluorophenyl)porphyrin (F20TPP), in combination with lithium salts, provides an efficient matrix to cationize small molecules by Li+ attachment and that this combination can be successfully applied to the quantitative analysis of drugs, such as antiretroviral compounds using matrix-assisted laser desorption ionization in conjunction with a time-of-flight analyzer (MALDI,TOF). In the present study, we further explore the mechanism of metal ion attachment to F20TPP and analytes by MALDI,FTMS(/MS). To this end, we have studied the interaction of F20TPP and analytes with various mono-, di- and trivalent metal ions (Li+, Na+, K+, Rb+, Cs+, Co2+, Cu2+, Zn2+, Fe2+, Fe3+ and Ga3+). For the alkali cations, we find that F20TPP forms complexes only with Li+ and Na+; in addition, model analyte molecules such as poly(ethyleneglycol)s, mixed with F20TPP and the alkali cations, also only form Li+ and Na+ adducts. This contrasts sharply with the commonly used matrix 2,5-dihydroxybenzoic acid, where analytes are most efficiently cationized by Na+ or K+. Reasons for this difference are delineated. Ab initio calculations on porphyrin itself reveal that even the smallest alkali cation, Li+, does not fit in the porphyrin cavity, but lies on top of it, pushing the 21H and 23 H hydrogen atoms out of and below the plane with concomitant bending of the porphyrin skeleton in the opposite direction, i.e. toward the cation. Thus, the Li+ ion is not effectively sequestered and is in fact exposed and thus accessible for donation to analyte molecules. Interaction of F20TPP with di- and trivalent metal ions leads to protoporphyrin,metal ions, where the metal ion is captured within the protoporphyrin dianion cavity. The most intense signal is obtained when F20TPP is reacted with CuCl2 and then subjected to laser ablation. This method presents an easy general route to study the metal containing protoporphyrin molecules, which could all act as potential MALDI matrices. Copyright © 2009 John Wiley & Sons, Ltd. [source]


    Evaluation of a new matrix-free laser desorption/ionization method through statistic studies: comparison of the DIAMS (desorption/ionization on self-assembled monolayer surface) method with the MALDI and TGFA-LDI techniques

    JOURNAL OF MASS SPECTROMETRY (INCORP BIOLOGICAL MASS SPECTROMETRY), Issue 12 2008
    Matthieu Bounichou
    Abstract This work demonstrates that the desorption/ionization on self-assembled monolayer surface (DIAMS) mass spectrometry, a recent matrix-free laser desorption/ionization (LDI) method based on an organic target plate, is as statistically repeatable and reproducible as matrix assisted laser desorption ionization (MALDI) and thin gold film-assisted laser desorption/ionization (TGFA-LDI) mass spectrometries. On lipophilic DIAMS of target plates with a mixture of glycerides, repeatability/reproducibility has been estimated at 15 and 30% and the relative detection limit has been evaluated at 0.3 and 3 pmol, with and without NaI respectively. Salicylic acid and its d6 -isomer analysis confirm the applicability of the DIAMS method in the detection of compounds of low molecular weight. Copyright © 2008 John Wiley & Sons, Ltd. [source]


    A comparison of EDI with solvent-free MALDI and LDI for the analysis of organic pigments

    JOURNAL OF MASS SPECTROMETRY (INCORP BIOLOGICAL MASS SPECTROMETRY), Issue 4 2008
    Ichiro Kudaka
    Abstract To evaluate the applicability of EDI to material analysis as a new ionization method, a comparison of EDI with solvent-free matrix-assisted laser desorption ionization (MALDI) and laser desorption ionization (LDI) was made for the analysis of organic pigments, e.g. Pigment Yellow 93, Pigment Yellow 180, and Pigment Green 36, as test samples, which are poorly soluble in standard solvents. In EDI, the samples were prepared in two ways: deposition of suspended samples in appropriate solvents and dried on the substrate, and the direct deposition of the powder samples on the substrate. No matrices were used. Both sample preparation methods gave similar mass spectra. Equally strong signals of [M + H]+ and [M , H], ions were observed with some fragment ions for azo pigments in the respective positive or negative mode of operation. For the powder sample of the phthalocyanine pigment PG36, M+, and [M + H]+ in the positive mode and M,, in the negative mode of operation were observed as major ions. Positive-mode, solvent-free MALDI gave M+, [M + H]+ and [M + Na]+ and negative mode gave [M , H], depending on the sample preparation. As solvent-free MALDI, EDI was also found to be an easy-to-operate, versatile method for the samples as received. Copyright © 2008 John Wiley & Sons, Ltd. [source]


    Do collisions inside the collision cell play a relevant role in CID-LIFT experiments?,

    JOURNAL OF MASS SPECTROMETRY (INCORP BIOLOGICAL MASS SPECTROMETRY), Issue 1 2007
    Gloriano Moneti
    Abstract Collision experiments are a valid approach to characterize the ionic species generated by matrix assisted laser desorption ionization (MALDI). When a time-of-flight analyzer is employed, three different approaches are available for these experiments: the postsource decay (PSD), the LIFT and the MALDI-TOF/TOF. The last two are of particular interest because of the overcoming of the PSD problems related to mass calibration of the product ion spectra. Experiments performed by LIFT on linear or cyclic peptides, in presence or in absence of collision gas in the collision cell, gave evidence of an unexpected behavior: the two spectra were practically superimposable, and in the former case only a few new fragmentation channels were activated with low yield. These results mean that the selected ion exhibits a large amount of internal energy, capable of promoting fragmentation processes in the time window corresponding to the flight time between ion source and the acceleration electrode placed after the collision cell. Experiments performed by varying the plume density show that this internal energy uptake occurs in the expanding plume, through multiple collisions. The LIFT data have been compared with those achieved by collisions of ESI-generated [MH]+ ions of angotensin II performed under ,in-source' conditions and by triple-quadrupole experiments. The obtained results show a strong similarity among the spectra, indicating that the internal energy uptake in a MALDI source is comparable with that of 40-eV ions colliding with Ar in a triple-quadrupole instrument. Copyright © 2006 John Wiley & Sons, Ltd. [source]


    Laser desorption/ionization techniques in the characterization of high molecular weight oil fractions.

    JOURNAL OF MASS SPECTROMETRY (INCORP BIOLOGICAL MASS SPECTROMETRY), Issue 9 2006
    Part 1: asphaltenes
    Abstract The molecular weight distribution of the asphaltene fractions of two types of crude oils from two different Italian fields (samples 1 and 2) was investigated. The analytical tools used to perform these analyses were matrix assisted laser desorption ionization (MALDI) and laser desorption ionization (LDI) mass spectrometry. After observing that the use of the matrix (as well as the addition of Ag+) did not improve the quality of the data compared to that obtained in LDI conditions, all further measurements were performed with the latter technique. Operating under usual conditions of laser power and delay time, a very low resolution was observed, showing only macroscopic differences between the two samples in the molecular weight distribution of the different components. An accurate study on the possible reasons of this undesirable behavior indicates that it can originate from space charge phenomena occurring either in the ion source region or during the flight. A valid parameterization of the delay time and the laser power allowed higher quality spectra to be obtained. Surface-enhanced laser desorption ionization (SELDI) measurements were also performed using normal phase (silica) as the sample holder surface. Under these conditions, better results are obtained, proving that the sample,surface interaction is important to achieve, by means of laser irradiation, a homogeneous set of product ions. Both asphaltene samples were fractionated in five subfractions by gel-permeation chromatography (GPC) to obtain a better separation of the molecular weight distributions; the related spectra confirmed these findings. By using different approaches, relevant and reproducible differences between the asphaltene fractions of the two oil samples were observed. Copyright © 2006 John Wiley & Sons, Ltd. [source]


    On the determination of molecular weight distributions of asphaltenes and their aggregates in laser desorption ionization experiments

    JOURNAL OF MASS SPECTROMETRY (INCORP BIOLOGICAL MASS SPECTROMETRY), Issue 7 2006
    Ana R. Hortal
    Abstract Molecular weight distributions (MWD) of asphaltenes and their aggregates have been investigated in laser desorption ionization (LDI) mass spectrometric experiments. A systematic investigation of the dependence of the measured MWD on the asphaltene sample density and on the laser pulse energy allows the assignment of most probable molecular weights within 300,500 amu and average molecular weights of 800,1000 amu for the monomeric asphaltenes, as well as for the estimation of the contribution from asphaltene clusters in typical LDI measurements. The results serve to reconcile the existing controversy between earlier mass spectrometric characterizations of asphaltenes based on laser desorption techniques by different groups. Furthermore, the MWD measurements performed on particularly dense samples yield an additional differentiated broad band peaking around 9000,10 000 amu and extending over 20 000 amu, not observed previously in LDI experiments, thereby revealing a strong propensity of the asphaltenes to form clusters with specific aggregation numbers, which is in qualitative agreement with previous theoretical predictions and with the interpretation of measurements performed with other techniques. Copyright © 2006 John Wiley & Sons, Ltd. [source]


    Investigation of molecular interaction within biological macromolecular complexes by mass spectrometry

    MEDICINAL RESEARCH REVIEWS, Issue 3 2006
    Satoko Akashi
    Abstract The advent of electrospray ionization (ESI) and matrix-assisted laser desorption ionization (MALDI) has accelerated structural studies of biological macromolecular complexes. At present, mass spectrometry can provide accurate mass values not only of individual biological macromolecules but also of their assemblies. Furthermore, it can also give information on the interface sites of the biological macromolecular complexes. The present article focuses on the role of mass spectrometry in the investigation of biological molecular interactions, such as protein,protein, protein,DNA, and protein,ligand interactions, which play essential roles in various biological events. © 2006 Wiley Periodicals, Inc. [source]


    Mass spectrometry in the characterization of ambers.

    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, Issue 5 2008

    Amber is a fossil resin constituted of organic polymers derived through complex maturation processes of the original plant resin. A classification of eight samples of amber of different geological age (Miocene to Triassic) and geographical origin is here proposed using direct mass spectrometric techniques, i.e. laser desorption ionization (LDI), atmospheric pressure chemical ionization (APCI) and atmospheric pressure photoionization (APPI), in order to obtain a fingerprint related to the amber origin. Differences and similarities were detected among the spectra with the four methods, showing quite complex spectra, full of ionic species in the mass range investigated (up to m/z 2000). The evaluation required statistical analysis involving multivariate techniques. Cluster analysis or principal component analysis (PCA) generally did not show a clear clustering with respect to the age of samples, except for the APPI method, which allowed a satisfying clustering. Using the total ion current (TIC) obtained by the different analytical approaches on equal quantities of the different amber samples and plotted against the age, the only significant correlation appeared to be that involving APPI. To validate the method, four amber samples from Cretaceous of Spain were analyzed. Also in this case a significant correlation with age was found only with APPI data. PCA obtained with TIC values from all the MS methods showed a fair grouping of samples, according to their age. Three main clusters could be detected, belonging to younger, intermediate and older fossil resins, respectively. This MS analysis on crude amber, either solid or extract, followed by appropriate multivariate statistical evaluation, can provide useful information on amber age. The best results are those obtained by APPI, indicating that the quantity of amber soluble components that can be photoionized decreases with increasing age, in agreement with the formation of highly stable, insoluble polymers. Copyright © 2008 John Wiley & Sons, Ltd. [source]


    Mass spectrometry for the detection of differentially expressed proteins: a comparison of surface-enhanced laser desorption/ionization and capillary electrophoresis/mass spectrometry

    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, Issue 2 2004
    Nils v. Neuhoff
    The discovery of biomarkers is currently attracting much interest as it harbors great potential for the diagnosis and monitoring of human diseases. Here we have used two advanced mass spectroscopy based technologies, surface enhanced laser desorption ionization (SELDI-MS) and capillary electrophoresis/mass spectrometry (CE/MS), to obtain proteomic patterns of urine samples from patients suffering from membranous glomerulonephritis (MGN) and healthy volunteers. The results indicate that CE/MS analysis is able to display a rich and complex pattern of polypeptides with high resolution and high mass accuracy. In order to analyze these patterns, the MosaiqueVisu software was developed for peak identification, deconvolution and the display of refined maps in a three-dimensional format. The polypeptide profiles obtained with SELDI-MS from the same samples are much sparser and show lower resolution and mass accuracy. The SELDI-MS profiles are further heavily dependent on analyte concentration. SELDI-MS analysis identified three differentially expressed polypeptides, which are potential biomarkers that can distinguish healthy donors from patients with MGN. In contrast, approximately 200 potential biomarkers could be identified by CE/MS. Thus, while SELDI-MS is easy to use and requires very little sample, CE/MS generates much richer data sets that enable an in-depth analysis. Copyright © 2003 John Wiley & Sons, Ltd. [source]


    Differential Capture of Serum Proteins for Expression Profiling and Biomarker Discovery in Pre- and Posttreatment Head and Neck Cancer Samples,

    THE LARYNGOSCOPE, Issue 1 2008
    Gary L. Freed MD
    Abstract Introduction: A long-term goal of our group is to develop proteomic-based approaches to the detection and use of protein biomarkers for improvement in diagnosis, prognosis, and tailoring of treatment for head and neck squamous cell cancer (HNSCC). We have previously demonstrated that protein expression profiling of serum can identify multiple protein biomarker events that can serve as molecular fingerprints for the assessment of HNSCC disease state and prognosis. Methods: An automated Bruker Daltonics (Billerica, MA) ClinProt matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometer was used. Magnetic chemical affinity beads were used to differentially capture serum proteins prior to MALDI-TOF analysis. The resulting spectra were analyzed using postprocessing software and a pattern recognition genetic algorithm (ClinProt 2.0). An HNSCC cohort of 48 sera samples from 24 patients consisting of matched pretreatment and 6 to 12 month posttreatment samples was used for further analysis. Low-mass differentially expressed peptides were identified using MALDI-TOF/TOF. Results: In the working mass range of 1,000 to 10,000 m/z, approximately 200 peaks were resolved for ionic bead capture approaches. For spectra generated from weak cation bead capture, a k-nearest neighbor genetic algorithm was able to correctly classify 94% normal from pretreatment HNSCC samples, 80% of pretreatment from posttreatment samples, and 87% of normal from posttreatment samples. These peptides were then analyzed by MALDI-TOF/TOF mass spectometry for sequence identification directly from serum processed with the same magnetic bead chemistry or alternatively after gel electrophoresis separation of the captured proteins. We were able to compare this with similar studies using surface-enhanced laser desorption ionization (SELDI)-TOF to show this method as a valid tool for this process with some improvement in the identification of our groups. Conclusions: This initial study using new high-resolution MALDI-TOF mass spectrometry coupled with bead fractionation is suitable for automated protein profiling and has the capability to simultaneously identify potential biomarker proteins for HNSCC. In addition, we were able to show improvement with the MALDI-TOF in identifying groups with HNSCC when compared with our prior data using SELDI-TOF. Using this MALDI-TOF technology as a discovery platform, we anticipate generating biomarker panels for use in more accurate prediction of prognosis and treatment efficacies for HNSCC. [source]


    Synovial fluid proteins differentiate between the subtypes of juvenile idiopathic arthritis

    ARTHRITIS & RHEUMATISM, Issue 6 2010
    Margalit E. Rosenkranz
    Objective Juvenile idiopathic arthritis (JIA) is a heterogeneous group of inflammatory diseases, and no clinically useful prognostic markers to predict disease outcome in children with JIA are currently available. Synovial fluid likely reflects the proteins present in the inflamed synovium. The purpose of this study was to delineate the synovial fluid proteome and determine whether protein expression differs in the different subtypes of JIA. Methods Synovial fluid samples obtained from children with oligoarticular JIA, polyarticular JIA, or systemic JIA were compared. Two-dimensional gel electrophoresis for protein separation and matrix-assisted laser desorption ionization,time-of-flight mass spectrometry and quadripole time-of-flight mass spectrometry for protein identification were used for this study. Synovial fluid cells were analyzed by polymerase chain reaction (PCR) for the presence of haptoglobin messenger RNA (mRNA). Results The synovial fluid proteome of the samples was delineated. The majority of proteins showed overexpression in JIA synovial fluid as compared with noninflammatory control samples. There were 24 statistically significantly differentially expressed spots (>2-fold change; P < 0.05) between the subtypes of JIA. PCR analysis revealed haptoglobin mRNA, suggesting that haptoglobin is locally produced in an inflamed joint in JIA. Conclusion Despite the similar histologic appearance of inflamed joints in patients with different subtypes of JIA, there are differences in protein expression according to the subtype of JIA. Haptoglobin is differentially expressed between the subtypes of JIA and is locally produced in an inflamed joint in JIA. Haptoglobin and other differentially expressed proteins may be potential biomarkers in JIA. [source]


    Proteomic analysis by two-dimensional electrophoresis to identify the normal human chondrocyte proteome stimulated by tumor necrosis factor , and interleukin-1,

    ARTHRITIS & RHEUMATISM, Issue 3 2010
    Berta Cillero-Pastor
    Objective To determine the intracellular proteome of normal human chondrocytes stimulated with interleukin-1, (IL-1,) and tumor necrosis factor , (TNF,) and to ascertain differences in the protein expression patterns of these 2 cytokines. Methods Normal human knee cartilage chondrocytes were incubated for 48 hours without stimulation or stimulated with IL-1, (5 ng/ml) or with TNF, (10 ng/ml). For each culture condition, protein extracts from 4 normal subjects were pooled and resolved using 2-dimensional electrophoresis. Protein spots were visualized with Sypro stain, and qualitative and quantitative analyses were performed using PDQuest software. Protein spots were then identified by mass spectrometry, using matrix-assisted laser desorption ionization,time-of-flight/time-of-flight technology. Results We identified 37 spots by mass spectrometry (MS) or by MS/MS, corresponding to 35 different proteins. In IL-1,,stimulated chondrocytes, IL-1, was found to modulate 22 proteins, as compared with unstimulated chondrocytes. All of these proteins except connective tissue growth factor (CCND2) were up-regulated. Proteins involved in cellular metabolism and energy (23%) that were up-regulated or induced by IL-1, included nicotinamide phosphoribosyltransferase, long-chain fatty acid,coenzyme A ligase 4, ,-aminolevulinic acid dehydratase, triosephosphate isomerase, and an isoform of glyceraldehyde-3-phosphate dehydrogenase. In TNF,-stimulated chondrocytes, TNF, was found to modulate 20 proteins, as compared with unstimulated chondrocytes. All of these except chitinase 3,like 1 (cartilage glycoprotein 39), proteasome activator complex subunit 2, and G3PDH, were up-regulated. Eighteen proteins were differently modulated by IL-1, and TNF,. Of these, 45% were related to metabolism. Conclusion IL-1, and TNF, induce different profiles of intracellular protein expression in healthy human chondrocytes. Most of the proteins that are differently regulated are proteins that are implicated in the generation of cellular energy and in glycolysis. [source]


    Avascular necrosis of the femoral head in a patient with Fabry's disease: Identification of ceramide trihexoside in the bone by delayed-extraction matrix-assisted laser desorption ionization,time-of-flight mass spectrometry

    ARTHRITIS & RHEUMATISM, Issue 7 2002
    Hiroshi Horiuchi
    Fabry's disease is a lipid storage disease caused by an X-linked hereditary deficiency of ,-galactosidase. The enzymatic defect causes progressive deposition of ceramide trihexoside (CTH) in various tissues, leading to renal failure, premature myocardial infarction, and stroke, with a high rate of mortality in younger patients. Among the complications associated with Fabry's disease, a few cases involving avascular necrosis (AVN) of the femoral head have been reported. However, direct evidence of deposition of CTH in bone marrow in the femoral head has not been demonstrated. This report describes a 58-year-old man who underwent total hip arthroplasty for femoral head AVN associated with Fabry's disease. The accumulation of CTH was examined by chemical analysis of the sphingolipid extracted from the femoral head, using delayed-extraction matrix-assisted laser desorption ionization,time-of-flight mass spectrometry. This is the first report confirming the presence of CTH in the sphingolipid fraction from normal and necrotic bone of a patient with Fabry's disease. [source]


    Structural studies of wheat flour glutenin polymers by CD spectroscopy

    BIOPOLYMERS, Issue 4 2004
    S. Fisichella
    Abstract A dissolution procedure of unreduced glutenin polymers of three wheat flour varieties (WRU 6981, Alisei 1, and Alisei 2) by sonication in the presence of SDS (sodium dodecyl sulphate), after the elimination of albumins, globulins, and gliadins, was achieved, and the molecular weight distribution of glutenin polymers obtained by this method was measured by matrix assisted laser desorption ionization,time of flight (MALDI-TOF) mass spectrometry. A structural study by CD spectroscopy at different temperatures of WRU 6981 glutenin polymer and of 1Ax1 high- Mr (relative molecular mass) glutenin subunit, which is the only high- Mr subunit contained in WRU 6981 flour, was undertaken to understand if the information obtained from the single subunit were applicable to the total polymer. CD spectroscopy also has been employed to study the glutenin polymers obtained by Alisei 1 and Alisei 2 wheat flours; Alisei 1 biotype contained 1Bx7 and 1Dx2+1Dy12 high-Mr subunits, whereas the Alisei 2 biotype contained only 1Bx7 and 1Dy12 subunits. A conformational study was undertaken by CD spectroscopy at different temperatures and in the presence of some chemical denaturant agents, such as urea and sodium dodecyl sulphate, in order to obtain information about their intrinsic stability and to verify if the 1Dx2 subunit presence determined a different structural behavior between Alisei 1 and Alisei 2 polymers. MALDI-TOF mass spectrometric experiments showed that the glutenin polymers molecular weights were in the mass range of 500,000,5,000,000. CD spectra indicated that a single conformational state did not predominate in the temperature range studied but equilibrium between two distinct conformational states existed; moreover, all the changes induced by urea and by SDS followed a multistep transition process. © 2004 Wiley Periodicals, Inc. Biopolymers, 2004 [source]


    Determination of metastasis-associated proteins in non-small cell lung cancer by comparative proteomic analysis

    CANCER SCIENCE, Issue 8 2007
    Tian Tian
    The development of metastasis is the leading cause of death and an enormous therapeutic challenge in cases of non-small cell lung cancer. To better understand the molecular mechanisms underlying the metastasis process and to discover novel potential clinical markers for non-small cell lung cancer, comparative proteomic analysis of two non-small cell lung cancer cell lines with different metastatic potentials, the non-metastatic CL1-0 and highly metastatic CL1-5 cell lines, was carried out using two-dimensional electrophoresis followed by matrix-assisted laser desorption ionization,time of flight mass spectrometry and tandem mass spectrometry. Thirty-three differentially expressed proteins were identified unambiguously, among which 16 proteins were significantly upregulated and 17 proteins were downregulated in highly metastatic CL1-5 cells compared with non-metastatic CL1-0 cells. Subsequently, 8 of 33 identified proteins were selected for further validation at the mRNA level using real-time quantitative polymerase chain reaction, and three identified proteins, S100A11, PGP 9.5 and HSP27, were confirmed by western blotting. The protein S100A11 displaying significant differential expression at both the protein and mRNA levels was further analyzed by immunohistochemical staining in 65 primary non-small cell lung cancer tissues and 10 matched local positive lymph node specimens to explore its relationship with metastasis. The results indicated that the upregulation of S100A11 expression in non-small cell lung cancer tissues was significantly associated with higher tumor,node,metastasis stage (P = 0.001) and positive lymph node status (P = 0.011), implying that S100A11 might be an important regulatory molecule in promoting invasion and metastasis of non-small cell lung cancer. (Cancer Sci 2007; 98: 1265,1274) [source]