LC/MS/MS Analysis (lc/ms/m + analysis)

Distribution by Scientific Domains


Selected Abstracts


Improving peptide identification using an empirical peptide retention time database

RAPID COMMUNICATIONS IN MASS SPECTROMETRY, Issue 1 2009
Wei Sun
Peptide retention time (RT) is independent of tandem mass spectrometry (MS/MS) parameters and can be combined with MS/MS information to enhance peptide identification. In this paper, we utilized peptide empirical RT and MS/MS for peptide identification. This new approach resulted in the construction of an Empirical Peptide Retention Time Database (EPRTD) based on peptides showing a false-positive rate (FPR) ,1%, detected in several liquid chromatography (LC)/MS/MS analyses. In subsequent experiments, the RT of peptides with FPR >1% was compared with empirical data derived from the EPRTD. If the experimental RT was within a specified time range of the empirical value, the corresponding MS/MS spectra were accepted as positive. Application of the EPRTD approach to simple samples (known protein mixtures) and complex samples (human urinary proteome) revealed that this method could significantly enhance peptide identification without compromising the associated confidence levels. Further analysis indicated that the EPRTD approach could improve low-abundance peptides and with the expansion of the EPRTD the number of peptide identifications will be increased. This approach is suitable for large-scale clinical proteomics research, in which tens of LC/MS/MS analyses are run for different samples with similar components. Copyright © 2008 John Wiley & Sons, Ltd. [source]


Isobaric metabolite interferences and the requirement for close examination of raw data in addition to stringent chromatographic separations in liquid chromatography/tandem mass spectrometric analysis of drugs in biological matrix

RAPID COMMUNICATIONS IN MASS SPECTROMETRY, Issue 13 2008
Zhengyin Yan
In addition to matrix effects, common interferences observed in liquid chromatography/tandem mass spectrometry (LC/MS/MS) analyses can be caused by the response of drug-related metabolites to the multiple reaction monitoring (MRM) channel of a given drug, as a result of in-source reactions or decomposition of either phase I or II metabolites. However, it has been largely ignored that, for some drugs, metabolism can lead to the formation of isobaric or isomeric metabolites that exhibit the same MRM transitions as parent drugs. The present study describes two examples demonstrating that interference caused by isobaric or isomeric metabolites is a practical issue in analyzing biological samples by LC/MS/MS. In the first case, two sequential metabolic reactions, demethylation followed by oxidation of a primary alcohol moiety to a carboxylic acid, produced an isobaric metabolite that exhibits a MRM transition identical to the parent drug. Because the drug compound was rapidly metabolized in rats and completely disappeared in plasma samples, the isobaric metabolite appeared as a single peak in the total ion current (TIC) trace and could easily be quantified as the drug since it was eluted at a retention time very close to that of the drug in a 12-min LC run. In the second example, metabolism via the ring-opening of a substituted isoxazole moiety led to the formation of an isomeric product that showed an almost identical collision-induced dissociation (CID) MS spectrum as the original drug. Because two components were co-eluted, the isomeric product could be mistakenly quantified and reported by data processing software as the parent drug if the TIC trace was not carefully inspected. Nowadays, all LC/MS data are processed by computer software in a highly automated fashion, and some analysts may spend much less time to visually examine raw TIC traces than they used to do. Two examples described in this article remind us that quality data require both adequate chromatographic separations and close examination of raw data in LC/MS/MS analyses of drugs in biological matrix. Copyright © 2008 John Wiley & Sons, Ltd. [source]


A simplified protein precipitation/mixed-mode cation-exchange solid-phase extraction, followed by high-speed liquid chromatography/mass spectrometry, for the determination of a basic drug in human plasma

RAPID COMMUNICATIONS IN MASS SPECTROMETRY, Issue 18 2006
Y.-J. Xue
A simplified protein precipitation/mixed-mode cation-exchange solid-phase extraction (PPT/SPE) procedure has been investigated. A mixture of acetonitrile and methanol along with formic acid was used to precipitate plasma proteins prior to selectively extracting the basic drug. After vortexing and centrifugation, the supernatants were directly loaded onto an unconditioned Oasis® MCX µElution 96-well extraction plate, where the protonated drug was retained on the negatively charged sorbent while interfering neutral lipids, steroids or other endogenous materials were washed away. Normal wash steps were deemed unnecessary and not used before sample elution. The sample extracts were analyzed under both conventional and high-speed liquid chromatography/tandem mass spectrometry (LC/MS/MS) conditions to examine the feasibility of the PPT/SPE procedure for human plasma sample clean-up. For the conventional LC/MS/MS method, chromatographic separation was achieved on a C18, 2.1,×,50,mm column with gradient elution (k,,=,5.5). The mobile phase contained 0.1% formic acid in water and 0.1% formic acid in acetonitrile. For the high-speed LC/MS/MS method, chromatographic separation was achieved on a C18, 2.1,×,10,mm guard column with gradient elution (k,,=,2.2, Rt,=,0.26,min). The mobile phase contained 0.1% formic acid in water and 0.001% trifluoroacetic acid in acetonitrile. Detection for both conventional and high-speed LC/MS/MS methods was by positive ion electrospray tandem mass spectrometry on a ThermoElectron Finnigan TSQ Quantum Ultra, where enhanced resolution (RP 2000; 0.2,amu) was used for high-speed LC/MS/MS. The standard curve, ranging from 0.5 to 100,ng/mL, was fitted to a 1/x weighted quadratic regression model. This combined PPT/SPE procedure effectively eliminated time-consuming sorbent conditioning and wash steps, which are essential for a conventional mixed-mode SPE procedure, but retained the advantages of both PPT (removal of plasma proteins) and mixed-mode SPE (analyte selectivity). The validation results demonstrated that this PPT/SPE procedure was well suited for both conventional and high-speed LC/MS/MS analyses. In comparison with a conventional mixed-mode SPE procedure, the simplified PPT/SPE process provided comparable sample extract purity. This simple sample clean-up procedure can be applied to other basic compounds with minor modifications of PPT solvents. Copyright © 2006 John Wiley & Sons, Ltd. [source]


Automatic function switching and its usefulness in peptide and protein analysis using direct infusion microspray quadrupole time-of-flight mass spectrometry

RAPID COMMUNICATIONS IN MASS SPECTROMETRY, Issue 19 2001
Emmy Hoyes
Automatic function switching has been investigated for high-throughput protein identification and sequencing of peptides using direct infusion of tryptic digests on a quadrupole time-of-flight instrument. The increase in speed and the high quality of data make it a favourable technique for tandem mass spectrometry when compared to manual selection of each precursor ion; these advantages are not restricted to combined LC/MS/MS analyses for which the automatic function-switching mode was originally developed. This mode was compared to analyses performed using a slow scan of the quadrupole analyzer with repeated recording of product ion spectra. For the specific purpose of generating product ion data for sequence determination (as opposed to surveying all precursors of a selected product ion), the automatic function-switching mode was, as expected, markedly superior with respect to speed of analysis and quality of data. Furthermore, the automatic function-switching mode provides greater versatility with respect to selection of optimal collision energies. Copyright © 2001 John Wiley & Sons, Ltd. [source]


Peptidomic analysis of the larval Drosophila melanogaster central nervous system by two-dimensional capillary liquid chromatography quadrupole time-of-flight mass spectrometry

JOURNAL OF MASS SPECTROMETRY (INCORP BIOLOGICAL MASS SPECTROMETRY), Issue 2 2005
Geert Baggerman
Abstract Peptides are the largest class of signalling molecules found in animals. Nevertheless, in most proteomic studies peptides are overlooked since they literally fall through the mazes of the net. In analogy with proteomics technology, where all proteins expressed in a cell or tissue are analyzed, the peptidomic approach aims at the simultaneous visualization and identification of the whole peptidome of a cell or tissue, i.e. all expressed peptides with their post-translational modifications. In this paper we describe the analysis of the larval fruit fly central nervous system using two-dimensional capillary liquid chromatography/quadrupole time-of-flight tandem mass spectrometry (LC/Q-TOF-MS/MS. Using the central nervous systems of only 50 larval Drosophila as starting material, we identified 38 peptides in a single analysis, 20 of which were not detected in a previous study that reported on the one-dimensional capillary LC/MS/MS analysis of the same tissue. Among the 38 sequenced peptides, some originate from precursors, such as the tachykinin and the IFamide precursor that were entirely missed in the first study. This clearly demonstrates that the two-dimensional capillary LC approach enhances the coverage of the peptidomic analysis. Copyright © 2005 John Wiley & Sons, Ltd. [source]


Screening of antioxidant phenolic compounds in Chinese Rhubarb combining fast counter-current chromatography fractionation and liquid chromatography/mass spectrometry analysis

JOURNAL OF SEPARATION SCIENCE, JSS, Issue 11 2010
Ruilin Hu
Abstract In this paper, an effective method combing fast elution-extrusion counter-current chromatography (CCC) and LC/MS for rapid screening of antioxidative phenolic compounds in Chinese Rhubarb is presented. An integrated three-coil CCC column (40,mL each coil) was used to accomplish the optimization of biphasic liquid system. In a single run (approximately 40,min), the solvent system composed of n -hexane/ethyl acetate/methanol/water (1:1:1:1, v/v) was selected as optimum CCC liquid system for fast fractionation of the crude ethanol extract. With a 140,mL-capacity CCC instrument, 100,mg Chinese Rhubarb extract was separated under the optimized conditions, producing six fractions in only 100,min. The quantities of each fraction were ,15,mg. In addition, each fraction was subjected to antioxidant activity assay and characterized by LC/MS analysis. Fifty compounds, including phenolic acids, phenolic glucosides and hydroxyanthraquinones, were detected by LC/MS/MS analysis. As a result, gallic acid together with Fr I showed excellent antioxidant activity, which was well consistent with previous studies and exhibited great potential for natural drug discovery program of the present method. [source]


Extensive fractionation and identification of proteins within nasal lavage fluids from allergic rhinitis and asthmatic chronic rhinosinusitis patients

JOURNAL OF SEPARATION SCIENCE, JSS, Issue 1 2009
Linda M. Benson
Abstract Allergic rhinitis (AR), chronic rhinosinusitis (CRS), and asthma are prevalent airway diseases that can have a substantial impact on a patient's quality of life. MS analyses of biological fluids can effectively screen for proteins associated with disease processes, however, initial detection of diagnostic proteins is difficult due to protein complexity and dynamic range. To enhance the detection of lower abundance proteins, intact nasal lavage fluid (NLF) proteins from nonpolypoid AR and from asthmatic CRS patients were extensively fractionated prior to LC/MS/MS analysis. Pooled NLF samples were processed to remove low molecular weight molecules and high abundance plasma proteins. Anion exchange (AX) chromatography followed by RP-LC further separated the remaining intact NLF proteins. The resulting fractions were digested with trypsin and the peptides analyzed by LC/MS/MS. Spectra were searched with MASCOT, SEQUEST, and X!Tandem to obtain peptide identifications and subsequently analyzed by Scaffold software to identify parent proteins with at least 99% confidence. The 197 identified proteins are compared to those previously cited in the literature and the workflow evaluated to determine the usefulness for the detection of lower abundance proteins. This is the first extensive list of NLF proteins generated from CRS patients with coexisting asthma. [source]


Semi-quantitative and structural metabolic phenotyping by direct infusion ion trap mass spectrometry and its application in genetical metabolomics

RAPID COMMUNICATIONS IN MASS SPECTROMETRY, Issue 15 2009
Albert Koulman
The identification of quantitative trait loci (QTL) for plant metabolites requires the quantitation of these metabolites across a large range of progeny. We developed a rapid metabolic profiling method using both untargeted and targeted direct infusion tandem mass spectrometry (DIMSMS) with a linear ion trap mass spectrometer yielding sufficient precision and accuracy for the quantification of a large number of metabolites in a high-throughput environment. The untargeted DIMSMS method uses top-down data-dependent fragmentation yielding MS2 and MS3 spectra. We have developed software tools to assess the structural homogeneity of the MS2 and MS3 spectra hence their utility for phenotyping and genetical metabolomics. In addition we used a targeted DIMS(MS) method for rapid quantitation of specific compounds. This method was compared with targeted LC/MS/MS methods for these compounds. The DIMSMS methods showed sufficient precision and accuracy for QTL discovery. We phenotyped 200 individual Loliumperenne genotypes from a mapping population harvested in two consecutive years. Computational and statistical analyses identified 246 nominal m/z bins with sufficient precision and homogeneity for QTL discovery. Comparison of the data for specific metabolites obtained by DIMSMS with the results from targeted LC/MS/MS analysis showed that quantitation by this metabolic profiling method is reasonably accurate. Of the top 100 MS1 bins, 22 ions gave one or more reproducible QTL across the 2 years. Copyright © 2009 John Wiley & Sons, Ltd. [source]


High-throughput determination of carbocysteine in human plasma by liquid chromatography/tandem mass spectrometry: application to a bioequivalence study of two formulations in healthy volunteers

RAPID COMMUNICATIONS IN MASS SPECTROMETRY, Issue 7 2006
Hui-chang Bi
A rapid and sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) method to determine carbocysteine in human plasma was developed and fully validated. After methanol-induced protein precipitation of the plasma samples, carbocysteine was subjected to LC/MS/MS analysis using electrospray ionization (ESI). The MS system was operated in the selected ion monitoring (SRM) mode. Chromatographic separation was performed on a Hypurity C18 column (i.d. 2.1,mm,×,50,mm, particle size 5,µm). The method had a chromatographic running time of 2.0,min and linear calibration curves over the concentration ranges of 0.1,20,µg/mL for carbocysteine. The lower limit of quantification (LLOQ) of the method was 0.1,µg/mL for carbocysteine. The intra- and inter-day precision was less than 7% for all quality control samples at concentrations of 0.5, 2.0, and 10.0,µg/mL. These results indicate that the method was efficient with a simple preparation procedure and a very short running time (2.0,min) for carbocysteine compared with methods reported in the literature and had high selectivity, acceptable accuracy, precision and sensitivity. The validated LC/MS/MS method has been successfully used to a bioequivalence study of two tablet formulations of carbocysteine in healthy volunteers. Copyright © 2006 John Wiley & Sons, Ltd. [source]


Liquid chromatography/tandem mass spectrometry for the identification and determination of trichothecenes in maize

RAPID COMMUNICATIONS IN MASS SPECTROMETRY, Issue 10 2003
Aldo Laganą
A reliable, sensitive and selective liquid chromatography/tandem mass spectrometry (LC/MS/MS) method has been developed to determine four trichothecene mycotoxins (nivalenol, deoxynivalenol, fusarenon X and 3-acetyldeoxynivalenol) in maize. Sample preparation was performed by extracting the analytes with a mixture of acetonitrile and water, followed by a solid-phase extraction with Carbograph-4 cartridges as the purification step. For the LC/MS/MS analysis two interfacing systems, Turbo IonSpray (TISP) and atmospheric pressure chemical ionization (APCI), were compared in both negative and positive ion modes. LC and MS parameters were optimized to achieve better results and sensitivity. The effect of mobile phase modifiers such as ammonium acetate and formic acid on the ionization yield was also evaluated. The best results were obtained using the electrospray ionization (ESI) interface in negative ion mode and the multiple reaction monitoring mode (MRM) for the quantitation. The detection limits ranged between 10,ng/g for fusarenon X and 1.5,ng/g for deoxynivalenol. A linear working range was achieved with a standard deviation between 3 and 10% and recovery rates from the maize samples above 81%. The procedure was applied to the analysis of a set of maize samples collected from farms located in different areas of northern and central Italy. The investigated samples turned out to be contaminated primarily with deoxynivalenol and, to a minor extent, with its derivatives. Copyright © 2003 John Wiley & Sons, Ltd. [source]


Determination of carbocysteine in human plasma by liquid chromatography/tandem mass spectrometry employing precolumn derivatization

RAPID COMMUNICATIONS IN MASS SPECTROMETRY, Issue 3 2003
Xiaoyan Chen
A sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) method was developed to determine carbocysteine in human plasma using 2-pyridylacetic acid as the internal standard (IS). The method employed derivatization with 10 M hydrochloric acid/methanol, which significantly improved the ionization efficiency of carbocysteine. After methanol-induced protein precipitation of plasma samples, carbocysteine and the IS were derivatized and subjected to LC/MS/MS analysis using atmospheric pressure chemical ionization. The method has a lower limit of quantitation of 20 ng/mL for a 0.2-mL plasma aliquot. The intra- and inter-day precision (RSD), calculated from quality control (QC) samples, was less than 7%. The accuracy, determined using QC samples, was within ±,1%. The method offered increased sensitivity, selectivity and speed of analysis over existing methods. The method was utilized to support clinical pharmacokinetic studies of carbocysteine in volunteers following oral administration. Copyright © 2002 John Wiley & Sons, Ltd. [source]


In vitro metabolism of a new H+/K+ ATPase inhibitor DBM-819 in liver microsomes using HPLC and electrospray mass spectrometry

BIOMEDICAL CHROMATOGRAPHY, Issue 8 2001
Sung Jin Choi
The metabolism of 1-(2-methyl-4-methoxyphenyl)-4-[(3-hydroxypropyl)amino]-6-methyl-2,3-dihydropyrrolo[3,2c]quinoline (DBM-819), a new H+/K+ ATPase inhibitor, has been studied by HPLC with spectrometric detection and on-line LC-electrospray mass spectrometry. In vitro incubation of DBM-819 with rat liver microsomes in the presence of NADPH resulted in the production of four metabolites (M1-4), whereas DBM-819 was oxidized to two metabolites, M2 and M4, by human liver microsomes. M2, M3 and M4 were identified as O-demethyl-DBM-819, 8-hydroxy-DBM-819 and N-dehydroxypropyl-DBM-819, respectively, based on LC/MS/MS analysis with authentic standards. M1 was tentatively identified as 1-(hydroxy-2-methyl-4-methoxyphenyl)-4-[(3-hydroxypropyl)amino]-6-methyl-2,3-dihydropyrrolo[3,2c]quinoline. Rat liver CYP1A1/2 catalyzed the oxidation of DBM-819 to 8-hydroxy-DBM-819 and N-dehydroxypropyl-DBM-819. Human CYP3A4 was a major isozyme for the formation of O-demethyl-DBM-819 as well as N-dehydroxypropyl-DBM-819. Copyright © 2001 John Wiley & Sons, Ltd. [source]