ITI Dental Implants (iti + dental_implant)

Distribution by Scientific Domains

Terms modified by ITI Dental Implants

  • iti dental implant system

  • Selected Abstracts


    A Three-Year Follow-Up Report of a Comparative Study of ITI Dental Implants® and Brånemark System® Implants in the Treatment of the Partially Edentulous Maxilla

    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, Issue 3 2004
    Per Åstrand DDS
    ABSTRACT Background: Many longitudinal studies of different implant systems have been published but few controlled randomized investigations have been reported. A 1-year report of a comparative study of ITI Dental Implant System® implants (Straumann AG, Waldenburg, Switzerland) and Brånemark System® implants (Nobel Biocare AB, Gothenburg, Sweden) has been published by the present authors. This paper is a 3-year follow-up of that randomized study. Purpose: The aim of the study was to compare the outcome of fixed partial prostheses supported by ITI or Branemark implants. The outcome was evaluated primarily in terms of survival rates and changes in marginal bone level. Material and Methods: The study group comprised 28 patients with anterior residual dentition in the maxilla. The patients were provided with two to four implants on each side of the dentition and were randomly allocated to Brånemark implants or ITI implants; 77 ITI implants and 73 Brånemark implants were inserted. After 6 months abutment connections were made to both ITI and Brånemark implants. All patients were provided with fked partial prostheses of gold-ceramic. The patients were followed up annually with clinical and radiographic examinations for 3 years. Results: Two Brånemark implants and two ITI implants were lost. The Brånemark implants were lost before loading whereas the ITI implants were lost because of periimplantitis. The survival rate for both groups was 97.3%. The mean marginal bone level of the Brånemark implants was situated 1.8 mm from the reference point at both the baseline and the 3-year examinations. The corresponding values for the ITI implants were 1.4 mm at baseline and 1.3 mm after 3 years. There was no significant difference between the implant systems with regard to bone level or bone level change. A steady state of the marginal bone level was calculated to have been reached after 3 years for 95.5% of the Brånemark implants and 87.1% of the ITI implants. Periimplantitis (infection including pus and bone loss) was observed with seven ITI implants but with none of the Brånemark implants. This difference was statistically significant. Conclusions: No statistically significant differences were found between the implants studied, except for the frequency of periimplantitis, which was higher for the ITI implants. The survival rates were high, and the marginal bone loss was small for both systems. [source]


    Effect of Implant Angulation upon Retention of Overdenture Attachments

    JOURNAL OF PROSTHODONTICS, Issue 1 2005
    MSEd, MSciDent, Michael P. Gulizio DMD
    Introduction: Overdentures supported and retained by endosteal implants depend upon mechanical components to provide retention. Ball attachments are frequently described because of simplicity and low cost, but retentive capacity of these components may be altered by a lack of implant parallelism. Purpose: The aim of this in vitro study was to investigate the retention of gold and titanium overdenture attachments when placed on ball abutments positioned off-axis. Methods and Materials: Four ball abutments were hand-tightened onto ITI dental implants and placed in an aluminum fixture that allowed positioning of the implants at 0°, 10°, 20°, and 30° from a vertical reference axis. Gold and titanium matrices were then coupled to the ball abutments at various angles and then subjected to pull tests at a rate of 2 mm/second; the peak loads of release (maximum dislodging forces) were recorded and subjected to statistical analyses. A balanced and randomized factorial experimental design testing procedure was implemented. Results: Statistically significant differences in retention of gold matrices were noted when ball abutments were positioned at 20° and 30°, but not at 0° and 10°. Statistically significant differences were noted among the titanium matrices employed for the testing procedure, as well as for the 4 ball abutments tested. Angle was not a factor affecting retention for titanium matrices. Conclusions: (1) The gold matrices employed for the testing procedures exhibited consistent values in retention compared to titanium matrices, which exhibited large variability in retention. (2) Angle had an effect upon the retention of gold matrices, but not for titanium matrices. [source]


    Dental implants placement in conjunction with osteotome sinus floor elevation: a 12-year life-table analysis from a prospective study on 588 ITI®implants

    CLINICAL ORAL IMPLANTS RESEARCH, Issue 2 2006
    Nicola Ferrigno
    Abstract Objectives: The purpose of this prospective study was to evaluate the clinical success of placing ITI dental implants in the posterior maxilla using the osteotome technique. Material and methods: All implants were placed following a one-stage protocol (elevating the sinus floor and placing the implant at the same time). Five hundred and eighty-eight implants were placed in 323 consecutive patients with a residual vertical height of bone under the sinus ranging from 6 to 9 mm. The mean observation follow-up period was 59.7 months (with a range of 12,144 months). This prospective study not only calculated the 12-year cumulative survival and success rates for 588 implants by life-table analysis but also the cumulative success rates for implant subgroups divided per implant length and the percentage of sinus membrane perforation were evaluated. Results: The 12-year cumulative survival and success rates were 94.8% and 90.8%, respectively. The analysis of implant subgroups showed slightly more favourable cumulative success rates for 12 mm long implants (93.4%) compared with 10 and 8 mm long implants (90.5% and 88.9%, respectively). During the study period, only 13 perforations of the Schneiderian membrane were detected with a perforation rate of 2.2% (13 perforations/601 treated sites). Ten perforations out of 13 were caused during the first half of the study period and of these, seven were detected during the first 3 years of this prospective study. Conclusion: Based on the results and within the limits of the present study, it can be concluded that ITI implant placement in conjunction with osteotome sinus floor elevation represents a safe modality of treating the posterior maxilla in areas with reduced bone height subjacent to the sinus as survival and success rates were maintained above 90% for a mean observation period of ,60 months. Shorter implants (8 mm implants) did not significantly fail more than longer ones (10 and 12 mm implants): the differences were small compared with the number of events; hence, no statistical conclusion could be drawn. But, from the clinical point of view, the predictable use of short implants in conjunction with osteotome sinus floor elevation may reduce the indication for complex invasive procedures like sinus lift and bone grafting procedures. [source]


    Human ex vivo bone tissue strains around immediately loaded implants supporting maxillary overdentures

    CLINICAL ORAL IMPLANTS RESEARCH, Issue 6 2005
    vanç Akça
    Abstract Purpose: To evaluate ex vivo bone tissue strains around maxillary implants supporting immediately loaded bar-retained overdentures. Material and methods: Ninety degree two-element rosette strain gauges were bonded on the labial bone of four ITI® dental implants placed in the maxillary anterior region of four completely edentulous maxilla of fresh human cadavers. The installation torque value (ITV) of each implant was measured by a custom-made torque wrench and resonance frequency analyses (RFAs) were undertaken. A bar-retained overdenture was fabricated for each cadaver, and two miniature load cells were integrated in the first molar region of the overdentures for controlled loading experiments. Strain measurements were performed at a sample rate of 10 kHz and under a maximum load of 100 N, simultaneously monitored from a computer connected to a data acquisition system. Finally, removal torque values (RTVs) of the implants were measured. Results: RFA values did not mirror ITVs, while RTVs of implants were slightly lower than the ITVs. Any correlation could not be obtained between RFA values and ITVs or RTVs. Maximum strains around loaded implants ranged between ,100 and ,550 ,, under 25,100 N. The axial and lateral strain values of posterior implants of both sides were higher than those of anterior implants under all loads (P<0.05). Conclusion: Because occlusal forces in humans tend to decrease because of age-related factors, maximum strains around immediately loaded implants supporting maxillary overdentures fall within physiologic levels. Résumé Le but de cette étude a été d'évaluer les tensions du tissu osseux ex vivo autour d'implants maxillaires portant des prothèses amovibles retenues sur une barre placée immédiatement après l'insertion des implants. Deux jauges de force en rosette à 90° ont été attachées au côté lingual de l'os de quatre implants dentaires ITI® placés dans la région antérieure du maxillaire de quatre cadavres humains frais aux maxillaires édentées. La valeur du couple de torsion lors de l'installation (ITV) de chaque implant a été mesurée par un couple fabriqué et des analyses de fréquence de résonnance (RFA) ont été faites. Une prothèse retenue par une barre a été fabriquée pour chaque cadavre et deux cellules de charge miniatures ont été intégrées dans la région de la première molaire de ces prothèses pour les expériences de charge contrôlées. Les mesures de force ont été effectuées à un taux d'échantillonnage de 10 kHz et sous une charge maximale de 100 N, suivies simultanément par un ordinateur connectéà un système d'acquisition de données. Finalement les valeurs des couples de torsion à l'enlèvement (RTV) des implants ont été mesurées. Les valeurs RFA n'étaient pas en ligne avec les ITV tandis que les RTV des implants étaient légèrement inférieurs aux ITV. Aucune corrélation n'a pûêtre établie entre les valeurs RFA et ITV ou RTV. Les forces maximales autour des implants chargés s'étalaient de ,100 ,e à,550 ,e sous 25 N à 100 N. Les valeurs des forces axiales et latérales des implants postérieurs des deux côtés étaient supérieures à celles des implants antérieurs sous toutes les charges (P<0.05). Zusammenfassung Ziel: Es war das Ziel dieser Arbeit, an bis vor kurzem vitalen Knochengewebe Spannungen um Oberkieferimplantate zu untersuchen, welche sofortbelastete und stegverankerte Hybridprothesen tragen. Material und Methoden: Auf den labialen Knochen von vier ITI-Implantaten in der vorderen Region des zahnlosen Oberkiefers von vier frisch verstorbenen Menschen klebte man Dehnmessinstrumente an. Man mass den Wert der Eindrehkraft (ITV) jedes einzelnen Implantates mit einem handelsblichen Drehmomentschlssel und fhrte eine Resonanzfrequenzanalyse (RFA) durch. Man stellte fr jede Leiche eine stegverankerte Hybridprothese her und man baute in der Region der ersten Molaren zwei kleine Messgerte ein, die kontrollierte Belastungsexperimente erlaubten. Dehnmessungen fhrte man mit einer Frequenz von 10 kHz und einer maximalen Belastung von 100 N durch, simultan aufgezeichnet von einem mit dem Messsystem verbundenen Komputer. Schliesslich mass man auch die Krfte, die es brauchte um die Implantate wieder auszudrehen (RTV). Resultate: Die RFA wiederspiegelte die ITV-Werte nicht, whrenddem die RTV-Werte der Implantate geringfgig tiefer waren als die ITV-Werte. Man konnte weder zwischen der RFA, den ITV-Werten oder den RTV-Werten eine Korrelation herstellen. Die maximalen Dehnungen um die Implantate erreichte Werte zwischen ,100 E und ,550 E bei einer Belastung zwischen 25 N und 100 N. Die axialen und lateralen Dehnkrfte bei posterioren Implantaten waren unter smtlichen getesteten Belastungen beidseits grsser als diejenigen der anterioren Implantate (P<0.05). Resumen Propósito: Evaluar las tensiones del tejido óseo ex vivo alrededor de implantes maxilares soportando sobredentaduras retenidas por barras con carga inmediata. Material y Métodos: Se pegaron dos indicadores de tensión de roseta de dos elementos de 90° en el hueso labial de cuatro implantes dentales ITI® colocados en la región maxilar anterior de cuatro maxilares completamente edéntulos de cadáveres humanos frescos. Se midió el valor del torque de instalación (ITV) de cada implante por medio de una chicharra de torque hecha a medida y se llevó a cabo análisis de frecuencia de resonancia (RFA). Se fabricó una sobredentadura retenida por barras para cada cadáver y se integraron dos células miniatura de carga en la región del primer molar de las sobredentaduras para los experimentos de carga controlada. Se llevaron a cabo mediciones de la tensión a un índice de muestra de 10 kHz y bajo una carga máxima de 100 N, simultáneamente monitorizada desde un ordenador conectado a sistema de adquisición de datos. Finalmente, se midieron los valores del torque de remoción (RTV) de los implantes. Resultados: Los valores de RFA no se reflejaron en los ITVs, mientras que los RTVs de los implantes fueron ligeramente más bajos que los ITVs. No se pudieron obtener correlaciones entre los valores de RFA y los ITVs o RTVE. Las tensiones máximas alrededor de los implantes cargados variaron entre ,100 ,, y ,550 ,, bajo 25 N a 100 N. Los valores de las tensiones axiales y laterales de los implantes posteriores de ambos lados fueron mayores que aquellos implantes anteriores bajo todas las cargas (P<0.05). [source]


    Impact of IL-1 genotype and smoking status on the prognosis of osseointegrated implants

    CLINICAL ORAL IMPLANTS RESEARCH, Issue 4 2004
    Boris Gruica
    Abstract Aim: This study evaluated the impact of the IL-1 genotype and smoking status on the prognosis and development of complications of osseointegrated implants. Material and methods: The clinical charts of 180 consecutively admitted patients were analyzed with respect to the occurrence of biological complications in conjunction with oral implants. Biologic complications were defined as clinical conditions with suppuration from the peri-implant sulcus, development of a fistula or peri-implantitis with radiologic bone loss. All patients had received one or more ITI® dental implants, which had been in function for at least 8 (range: 8,15) years. This patient population had received 292 implants. From these, 51 implants in 34 patients showed late (infectious) biologic complications, and 241 implants had survived without any biologic complications at all. Results: Of the 180 patients, 53 were smokers, who were subdivided in a series of classes according to their intensity of smoking and 127 were never smokers. Sixty-four of 180 (36%) patients tested positive for the IL-1 genotype polymorphism. This prevalence corresponds to previous reports for the prevalence of European descent populations. The results for the non-smoking group indicated no significant correlation between implant complications and a positive IL-1 genotype. However, there was a clear association for heavy smokers between a positive IL-1 genotype and implant complications. 6 of 12 or half of the heavy smokers and IL-1 genotype-positive patients had either an implant failure, i.e. loss of implant, or a biologic complication during the follow-up period. Conclusions: These findings have led to the conclusion that there is a synergistic effect between a positive IL-1 genotype and smoking that puts dental implants at a significantly higher risk of developing biologic complications during function. Résumé Le but de cette étude a été d'évaluer l'impact du génotype IL-1 du tabagisme sur le pronostic et le développement de complication des implants buccaux ostéoïntégrés. Les dossiers cliniques de 180 patients ont été analysés en ce qui concerne l'arrivée de complications biologiques en association avec les implants buccaux. Des complications biologiques étaient définies en tant que conditions cliniques avec suppuration depuis le sillon paroïmplantaire, le développement d'une fistule ou d'une paroïmplantite avec perte osseuse radiologique. Tous les patients avait reçu un ou plusieurs implants buccaux ITI qui avaient été en fonction pour au moins huit années (de 8 à 15 ans). Les patients avaient reçu 292 implants. Parmi ceux-ci 51 chez 34 patients ont montré des complications biologiques tardives (infectieuses) et 241 avaient survécu sans aucune complication biologique. Des 180 patients, 53 étaient fumeurs qui ont été divisés en une série de classes suivant l'intensité du tabagisme tandis que 127 étaient non-fumeurs. Soixante-quatre des 180 patients (36%) ont été testés positifs pour le polymorphisme du génotype IL-1. Cette fréquence globale correspond au rapport précédent pour la fréquence globale des populations européennes. Les résultats pour le groupe non-fumeur indiquait qu'il n'y avait aucune relation significative entre les complications implantaires et un génotype IL-1 positif. Cependant, il y avait une association évidente pour les gros fumeurs entre le génotype IL-1 positif et des complications implantaires. Six des douze soit la moitié des gros fumeurs et des patients au génotype IL-1 positif avaient soit un échec implantaire (c.-à-d. la perte de l'implant) soit une complication biologique durant le suivi. Ces résultats ont conduit à la conclusion qu'il y a un effet synergétique entre le génotype IL-1 positif et le tabagisme mettant les implants buccaux à un risque beaucoup plus important à développer des complications biologiques durant leur mise en fonction. Zusammenfassung Ziel: Diese Studie untersuchte den Einfluss des IL-1 Genotyps und der Rauchgewohnheiten auf die Prognose und auf die Entwicklung von Komplikationen bei osseointegrierten Implantaten. Material und Methoden: Die Krankengeschichten von 180 aufgenommenen Patienten wurden auf biologische Komplikationen in Zusammenhang mit Zahni Implantaten untersucht. Biologische Komplikationen wurden definiert als klinische Zustände mit Suppuration aus dem periimplantären Sulcus, Entwicklung einer Fistel oder Periimplantitis mit radiologischem Knochenverlust. Alle Patienten waren mit einem oder mehreren ITI® Implantaten versorgt worden, welche für mindestens 8 Jahre (Bandbreite: 8,15 Jahre) in Funktion standen. Diese Patientenpopulation war mit 292 Implantaten versorgt worden. Von diesen 292 Implantaten zeigten 51 Implantate bei 34 Patienten biologische (infektiöse) komplikationen und 241 Implantate hatten ohne biologische Komplikationen überlebt. Resultate: Von den 180 Patienten waren 53 Raucher, welche in Untergruppen gemäss Schweregrad des Rauchens aufgeteilt wurden und 127 waren Nicht-Raucher. 64 der 180 Patienten (36%) zeigten ein positives Testergebnis bezüglich IL-1 Genotyp Polymorphismus. Diese Prävalenz entspricht früheren Berichten über die Prävalenz bei einer Population europäischer Abstammung. Die Resultate der Nicht-Raucher Gruppe zeigten keine signifikanten Korrelationen zwischen Implantatkomplikationen und einem positiven IL-1 Genotyp. Jedoch bestand bei den starken Rauchern eine klare Assoziation zwischen dem positiven IL-1 Genotyp und Implantatkomplikationen. 6 von 12 oder die Hälfte der starken Raucher und IL-1 Genotyp positiven Patienten zeigten entweder einen Implantat Misserfolg, z.B. Verlust des Implantats, oder eine biologische Komplikation während der Beobachtungsperiode. Schlussfolgerung: Die Ergebnisse haben zur Schlussfolgerung geführt, dass ein synergistischer Effekt zwischen einem IL-1 positiven Genotyp und Rauchen besteht, welcher Zahni Implantate einem signifikant höheren Risiko für die Entwicklung von biologischen Misserfolgen während der Funktion aussetzt. Resumen Intención: Este estudio evaluó el impacto del genotipo IL-1 y el estatus de fumador en el pronóstico y desarrollo de complicaciones de implantes orales osteointegrados. Material y métodos: Se analizaron las historias clínicas de 180 pacientes admitidos consecutivamente en lo referente a la ocurrencia de complicaciones biológicas en conjunción implantes orales. Se definieron las complicaciones orales como condiciones clínicas con supuración del surco periimplantario, desarrollo de una fístula o de periimplantitis con pérdida radiológica de hueso. Todos los pacientes recibieron uno o mas implantes orales ITI®, que levaban al menos 8 (rango 8,15) años en función. Esta población de pacientes recibió 292 implantes orales. De estos, 51 implantes de 34 pacientes mostraron (infecciones) complicaciones biológicas tardías, y 241 implantes sobrevivieron sin ninguna complicación biológica. Resultados: De los 180 pacientes, 53 eran fumadores que se subdividieron en una serie de categorías de acuerdo con su intensidad de consumo de tabaco y 127 nunca fueron fumadores. 64 de 180 (36%) dieron positivo al test del polimorfismo genético de la IL-1. Esta prevalencia corresponde con informes previos de prevalencia en poblaciones de origen europeo. Los resultados para el grupo de los no fumadores no indicó relación significativa entre complicaciones de los implantes y genotipo IL-1 positivo. Sin embargo, hubo una asociación clara para los fumadores intensos entre complicaciones de los implantes y un genotipo IL-1 positivo. 6 de 12 o la mitad de los fumadores intensos y los pacientes genotipo IL-1 positivo tuvieron o fracaso del implante i.e. pérdida del implante o una complicación biológica durante el periodo de seguimiento. Conclusiones: Estos hallazgos nos han conducido a la conclusión de que hay un efecto sinérgico entre genotipo IL-1 positivo y tabaquismo que colocan a los implantes orales en un riesgo significativamente mas alto para desarrollar complicaciones biológicas durante la función. [source]


    Implant-supported fixed prostheses in the edentulous maxilla

    CLINICAL ORAL IMPLANTS RESEARCH, Issue 3 2004
    A 2-year clinical, radiological follow-up of treatment with non-submerged ITI implants
    Abstract Objectives: To evaluate the survival rate of non-submerged solid-screw ITI dental implants with a rough (titanium plasma sprayed, TPS) surface in the edentulous maxilla after 1 and 2 years of loading. Material and method:, Twenty-five patients (mean age 64 years) with edentulous upper jaws received five,seven implants and, after a mean healing time of 6.9 months, screw-retained implant-supported fixed prostheses. A total of 146 ITI solid screw TPS implants were inserted. The diameter of 56% of the implants was smaller (3.3 mm) than the standard (4.1 mm) and the diameter of the rest (44%) was standard. The bone quantity of the majority of the patients was low and the bone quality poor. Clinical parameters were registered at baseline and at two annual follow-ups. Radiological examinations and assessments were also made at these times. Results: Mean marginal bone level at baseline was measured at a point 4.52 mm (range 1.45,7.70, SD 1.2) apical of the reference point. Mean bone loss from baseline to 1 year of loading was 0.24 mm (SD 0.9, P=0.002) and from 1 year to 2 years of loading 0.15 mm (SD 0.4, P<0.001). Five implants failed, four of which were early failures prior to loading. One implant failed shortly after bridge installation. The cumulative survival rate was 96.6% after 1 and 2 years. Conclusion: ITI TPS solid-screw implants in combination with fixed prostheses had successful survival rates and were found to be a viable treatment alternative in the edentulous maxilla. Résumé Le but de cette étude a été d'évaluer le taux de survie d'implants dentaires ITI vis solides non-enfouis avec une surface TPS (titane plasma-spray) au niveau du maxillaire édenté après une ou deux années de mise en charge. Vingt-cinq patients d'un âge moyen de 64 ans avec des mâchoires supérieures édentées ont reçu de cinq à sept implants et, après un temps de guérison moyen de 6,9 mois, des prothèses fixées vissées à ces implants (ISFP). Un total de 146 implants TPS ITI vis pleines ont été insérés. Le diamètre de 56% des implants étaient plus petits (3,3 mm) que le reste des implants qui avaient un diamètre standard (4,1 mm). La longueur des implants variait de 6 à 16 mm. La quantité osseuse de la majorité des patients était faible et la qualité osseuse pauvre. Des paramètres cliniques ont été enregistrés lors de l'examen initial et après deux années. Des examens radiographiques ont également été effectués à ces moments. Le niveau osseux marginal moyen lors de l'examen initial a été mesuréà un point 4,52 mm (de 1,45 à 7,70 mm : SD 1,2 mm) en apical du point de référence. La perte osseuse moyenne entre l'examen de départ et un an après la mise en charge était de 0,24 mm (SD 0,9; p=0,0002) et entre la première et la deuxième année de 0,15 mm (SD 0,4; p<0,001). Cinq implants ont échoué, dont quatre avant la mise en charge. Un implant a échoué peu de temps après le placement du bridge. Le taux de survie cumulatif après une ou deux années était de 96,6%. Les implants ITI TPS vis pleines avec des prothèses fixées avaient des taux de survie excellents et représentaient un traitement alternatif de qualité pour les patients édentés du maxillaire supérieur. Zusammenfassung Ziele: Die Ueberlebensrate von transmukosalen dentalen ITI-Vollschraubenimplantaten mit einer rauen Oberfläche (titanplasmabeschichtet, TPS) im zahnlosen Oberkiefer nach 1 und 2 Jahren Belastung auszuwerten. Material und Methoden: Fünfundzwanzig Patienten (mittleres Alter 64 Jahre) mit zahnlosen Oberkiefern erhielten 5,7 Implantate und nach einer mittleren Einheilzeit von 6.9 Monaten wurden verschraubte festsitzende implantatgetragene Rekonstruktionen (ISFPs) eingesetzt. Insgesamt wurden 146 ITI-Vollschraubenimplantate eingesetzt. Der Durchmesser von 56% dieser Implantate war kleiner (3.3 mm) als der Standard (4.1 mm) und der Durchmesser der restlichen 44% war Standard. Bei der Mehrzahl der Patienten war die Knochenmenge gering und die Knochenqualität schlecht. Die klinischen Parameter wurden bei der Ausgangsuntersuchung und bei den zwei Nachuntersuchungen in jährlichen Abständen aufgenommen. Bei diesen Untersuchungen wurden auch radiologische Auswertungen durchgeführt. Resultate: Das marginale Knochenniveau zum Zeitpunkt der Ausgangsuntersuchung wurde an einem Punkt 4.52 mm (Bandbreite 1.45,7.70, SD 1.2) apikal des Referenzpunktes gemessen. Der mittlere Knochenverlust von der Ausgangsuntersuchung bis 1 Jahr nach Belastung betrug 0.24 mm (SD 0.9, P=0.002) und zwischen 1 und 2 Jahren nach Belastung betrug er 0.15 mm (SD 0.4, P>0.001). Fünf Implantate zeigten Misserfolge, vier davon waren Frühmisserfolge vor Belastung. Ein Implantat versagte kurz nach der Eingliederung der Brücke. Die kummulative Ueberlebensrate nach 1 und 2 Jahren betrug 96.6%. Schlussfolgerung: ITI TPS Vollschraubenimplantate in Kombination mit festsitzenden Rekonstruktion zeigten erfolgreiche Ueberlebensraten und scheinen eine überlebensfähige Behandlungsalternative im zahnlosen Oberkiefer darzustellen. Resumen Objetivos: Evaluar el índice de supervivencia de implantes ITI roscados macizos no sumergidos con una superficie rugosa (pulverizada con plasma de titanio, TPS) en el maxilar edéntulo tras 1 o 2 años de carga. Material y Métodos: Veinticinco pacientes (edad media 64 años) con maxilares superiores edéntulos recibieron 5,7 implantes y, tras un periodo de cicatrización medio de 6.9 meses, una prótesis fija atornillada implantosoportada (ISFPs). Se insertaron un total de 146 implantes ITI roscados macizos. El diámetro del 56% de los implantes fue menor (3.3 mm) que el estándar (4.1 mm) y el diámetro del resto (44%) fue estándar. La cantidad de hueso de la mayoría de los pacientes fue baja y la calidad de hueso baja. Los parámetros clínicos se registraron al inicio y en los exámenes anuales de seguimiento. También se realizaron exámenes radiológicos y valoraciones en estos momentos. Resultados: El nivel medio de hueso marginal al inicio se midió en un punto 4.52 (rango 1.45,7.70, SD 1.2) apical al punto de referencia. La pérdida de hueso desde el inicio hasta 1 año de carga fue de 0.24 mm (SD 0.9, P=0.002) y de 1 año a 2 años de carga fue de 0.15 mm (SD 0.4, P<0.001). Cinco implantes fracasaron al poco de instalar los puentes. El índice acumulativo de supervivencia fue del 95%. Conclusión: Los implantes roscados macizos ITI TPS en combinación con prótesis fijas tuvieron unos índices de supervivencia exitosos y se encontró que eran una alternativa de tratamiento viable en el maxilar edéntulo. [source]