Home About us Contact | |||
Internal Calibration (internal + calibration)
Selected AbstractsMolecular mass determination of plasma-derived glycoproteins by ultraviolet matrix-assisted laser desorption/ionization time-of-flight mass spectrometry with internal calibrationJOURNAL OF MASS SPECTROMETRY (INCORP BIOLOGICAL MASS SPECTROMETRY), Issue 11 2002Omar Belgacem Abstract Human plasma-derived antithrombin III (AT-III), factor IX (FIX) and vitronectin (VN) were characterized as native glycoproteins and in their de- N -glycosylated form by means of MALDI mass spectrometry. The average molecular masses of the three complex glycoproteins were determined applying internal calibration with high-mass, well-defined protein calibrants. Internal calibration generated for the 47 kDa yeast protein enolase a mass precision in the continuous and delayed extraction mode of ±0.12 and ±0.022%, respectively. The achievable mass accuracy for such a high-mass, unmodified protein was in the range of 0.02% in the continuous mode, which turned out to be better than in the delayed extraction mode. Purification of all (glyco) proteins (even the calibration proteins) by means of ZipTip® technology and direct elution with a solvent system containing the appropriate MALDI matrix turned out to be a prerequisite to measure the exact molecular masses with an internal calibration. The average molecular masses of the two different forms of AT-III, namely AT-III, and AT-III,, were shown to be 57.26 and 55.04 kDa, respectively. The 2.22 kDa mass difference is attributed to the known difference in carbohydrate content at one specific site (Asn-135). After exhaustive de- N -glycosylation (by means of PNGase F) of the ,- and ,-form and subsequent MALDI-MS analysis, average molecular masses of 48.96 and 48.97 kDa, respectively, were obtained. These values are in good agreement (,0.15%) with the calculated molecular mass (49.039 kDa) of the protein part based on SwissProt data. The molecular mass of the heavily post-translational modified glycoprotein FIX was found to be 53.75 kDa with a peak width at 10% peak height of 4.5 kDa, because of the presence of many different posttranslational modifications (N - and O -glycosylation at multiple sites, sulfation, phosphorylation, hydroxylation and numerous ,-carboxyglutamic acids). MALDI-MS molecular mass determination of the native, size-exclusion chromatography-purified, VN sample revealed that the glycoprotein was present as dimer with molecular mass of 117.74 kDa, which could be corroborated by non-reducing SDS-PAGE. After sample treatment with guanidine hydrochloride and mass spectrometric analysis, a single, new main component was detected. The molecular mass turned out to be 59.45 kDa, representing the monomeric form of VN, known as V75. The determined molecular mass value was shown to be on one hand lower than from SDS-PAGE and on the other higher than the calculated amino acid sequence molecular mass (52 277 Da), pointing to the well-known SDS-PAGE bias and to considerable post-translational modifications. Further treatment of the sample with a reducing agent and subsequent MALDI-MS revealed two new components with molecular masses of 49.85 and 9.41 kDa, corresponding to V65 and V10 subunits of VN. PNGase F digest of the V75 and V65 units and MS analysis, exhibiting a molecular mass reduction of 6.37 kDa in both cases, verified the presence of a considerable amount of N -glycans. Copyright © 2002 John Wiley & Sons, Ltd. [source] Closely spaced external standard: a universal method of achieving 5 ppm mass accuracy over the entire MALDI plate in axial matrix-assisted laser desorption/ionization time-of-flight mass spectrometryRAPID COMMUNICATIONS IN MASS SPECTROMETRY, Issue 19 2003Eugene Moskovets Close deposition of the sample and external standard was used in axial matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) to achieve mass accuracy equivalent to that obtained with an internal standard across the entire MALDI plate. In this work, the sample and external standard were deposited by continuous deposition in separate traces, each approximately 200,,m wide. The dependence of the mass accuracy on the distance between the sample and standard traces was determined across a MALDI target plate with dimensions of 57.5,mm,×,57.0,mm by varying the gap between the traces from 100,,m to 4,mm. During acquisition, two adjacent traces were alternately irradiated with a 200-Hz laser, such that the peaks in the resulting mass spectra combined the sample and external standard. Ion suppression was not observed even when the peptide concentrations in the two traces differed by more than two orders of magnitude. The five peaks from the external standard trace were used in a four-term mass calibration of the masses of the sample trace. The average accuracy across the whole plate with this method was 5,ppm when peaks of the sample trace had signal-to-noise ratios of at least 30 and the gap between the traces was approximately 100,,m. This approach was applied to determining peptide masses of a reversed-phase liquid chromatographic (LC) separation of a tryptic digest of , -galactosidase deposited as a long serpentine trace across the MALDI plate, with accuracy comparable to that obtainable using internal calibration. In addition, the eluent from reversed-phase LC separation of a strong cation-exchange fraction containing tryptic peptides from a yeast lysate along with the closely placed external standard was deposited on the MALDI plate. The data obtained in the MS and MS/MS modes on a MALDI-TOF/TOF mass spectrometer were combined and used in database searching with MASCOT. Since the significant score is a function of mass accuracy in the MS mode, database searching with high mass accuracy reduced the number of false positives and also added peptides which otherwise would have been eliminated at lower mass accuracy (false negatives). Copyright © 2003 John Wiley & Sons, Ltd. [source] High accuracy mass measurement of peptides with internal calibration using a dual electrospray ionization sprayer system for protein identificationRAPID COMMUNICATIONS IN MASS SPECTROMETRY, Issue 6 2002Feng Zhou A dual-ESI-sprayer system was constructed and applied to achieve high accuracy of peptide mass measurement for protein identification by means of peptide mapping. Sample was introduced in one sprayer, and reference in the other, thus making internal calibration possible greatly enhancing the mass accuracy. Several samples were utilized to evaluate the reliability of this dual-ESI-sprayer system. The range of mass errors was 0.16,5.37,ppm. The peptide masses of tryptic digests of myoglobin (horse) were measured by the HPLC/dual-ESI-MS system, with mass deviations ranging from 0.01,7.67,ppm, and about 75% mass deviations below 5,ppm with 40% below 1,ppm. These peptide masses were utilized to perform database searching for protein identification, and compared to results obtained by external calibration. This comparison showed that the internal calibration provides a more reliable method of protein identification, with a much smaller number of required peptides for matching, and with less CPU time consumed for database searching. Copyright © 2002 John Wiley & Sons, Ltd. [source] |