Home About us Contact | |||
Infusion Device (infusion + device)
Selected AbstractsAbsence of explicit and implicit memory in unconscious patients using a TCI of propofolACTA ANAESTHESIOLOGICA SCANDINAVICA, Issue 7 2003P. Y. Lequeux Background:, ,Episodes of implicit memory have been described during propofol anaesthesia. It remains unclear whether implicit memory is caused by short periods of awareness or occurs in an unconscious subject. Methods:, Sixty patients were randomized in an experimental group (EG), a control group (CG) and a reference group (RG). Loss of consciousness (LOC) was obtained by progressive stepwise increases of propofol using a target-controlled infusion device (Diprifusor, Alaris Medical Systems, San Diego, CA). A tape containing 20 words was played to the patients in the CG before the start of anaesthesia and to the patients in the EG at a constant calculated concentration of propofol associated with LOC. The tape was not played to the patients in the RG. Three memory tests were performed postoperatively. Results:, Explicit and implicit memories were evidenced in the CG but not in the EG. Conclusion:, In our group of young ASA I/II patients, in the absence of any noxious stimulus, no implicit or explicit memory was found when the calculated concentration of propofol using a Diprifusor was maintained at the level associated with LOC. [source] Diploic venous anatomy studied in-vivo by MRICLINICAL ANATOMY, Issue 3 2009Khalil Jivraj Abstract Calvarial diploic venous anatomy has been studied post-mortem, but few studies have addressed these venous structures in-vivo. Previous work in our laboratory has shown that intraosseous infusion through the skull diploic space near the diploic veins in animals and humans does access the superior sagittal sinus and the systemic venous system. We developed a volumetric method of imaging the diploic veins in-vivo using MRI, intravenous gadolinium, and digital subtraction to provide for three-dimensional depiction and exact localization of these veins. We hypothesized that this technique would allow for an assessment of the probability of existence, distribution, and concentration of diploic veins in the skull. We scanned 31 neurosurgical patients, and were able to create 3D diploic venous maps in 74% of them. These maps were processed using Adobe Photoshop CS2. Mathworks MatLab 6.5, once customized, counted the number of pixels occupied by the diploic veins in the processed image. The probability of veins was highest in the occipital regions (100%). The inferior occipital (4.1%) and posterior parietal (4.1%) regions had the highest concentrations of diploic veins. Digital subtraction venography using a volumetric MRI sequence can demonstrate the diploic veins in-vivo. The inferior occipital region may be the best area for an intraosseous infusion device because it has the greatest likelihood of containing a vein and also has the highest concentration of veins. Clin. Anat. 22:296,301, 2009. © 2009 Wiley-Liss, Inc. [source] Continuous subcutaneous insulin infusion with short-acting insulin analogues or human regular insulin: efficacy, safety, quality of life, and cost-effectivenessDIABETES/METABOLISM: RESEARCH AND REVIEWS, Issue 3 2004Régis Pierre Radermecker Abstract Portable insulin infusion devices are effective and safe insulin delivery systems for managing diabetes mellitus, especially type 1 diabetes. Rapidly absorbed insulin analogues, such as insulin lispro or insulin aspart, may offer an advantage over regular human insulin for insulin pumps. Several open-label randomised crossover trials demonstrated that continuous subcutaneous insulin infusion (CSII) with insulin lispro provided a better control of postprandial hyperglycaemia and a slightly but significantly lower glycated haemoglobin level, with lower daily insulin requirement and similar or even less hypoglycaemic episodes. A CSII study comparing insulin lispro and insulin aspart demonstrated similar results with the two analogues, and better results than those with regular insulin. Because these analogues have a quicker onset and a shorter duration of action than regular insulin, one might expect an earlier and greater metabolic deterioration in case of CSII interruption, but a more rapid correction of metabolic abnormalities after insulin boluses when reactivating the pump. These expectations were confirmed in randomised protocols comparing the metabolic changes occurring during and after CSII interruption of various durations when the pump infused either insulin lispro or regular insulin. The extra cost resulting from the use of CSII and insulin analogues in diabetes management should be compensated for by better metabolic control and quality of life. In conclusion, CSII delivering fast-acting insulin analogues may be considered as one of the best methods to replace insulin in a physiological manner by mimicking meal and basal insulin requirements, without higher risk of hypoglycaemia or ketoacidosis in well-educated diabetic patients. Copyright © 2004 John Wiley & Sons, Ltd. [source] Bacterial contamination of PCA and epidural infusion devicesANAESTHESIA, Issue 7 2009M. Rothwell Summary We prospectively audited the bacterial contamination of re-useable analgesia infusion pumps. In a one-month period, 112 samples from the handset and keypads of our analgesia infusion pumps were cultured for bacterial contamination. Forty-five percent of handset swabs and 46% of keypad swabs grew bacteria; the commonest organism being coagulase-negative staphylococcus. An additional cleaning step using 70% isopropyl alcohol wipes was introduced and the contamination rate was re-audited in 100 samples. The contamination rate was reduced to 6% of handset swabs and 4% of keypad swabs. A high initial rate of bacterial contamination of re-useable analgesia infusion pumps was significantly reduced by the implementation of a simple, additional cleaning procedure. [source] |