Holter Recordings (holter + recording)

Distribution by Scientific Domains

Kinds of Holter Recordings

  • hour holter recording


  • Selected Abstracts


    Circadian Variation in QT Dispersion Determined from a 12-Lead Holter Recording: A Methodological Study of an Age- and Sex-Stratified Group of Healthy Subjects

    ANNALS OF NONINVASIVE ELECTROCARDIOLOGY, Issue 3 2007
    Stig Hansen M.D.
    Background: QT dispersion is considered to reflect inhomogeneity of myocardial repolarization. Method: The circadian variation of QT interval dispersion was examined in 95 healthy subjects using 24-hour Holter monitoring. Three different methods of lead selection were applied: all 12 leads (QTdisp 12), only precordial leads (QTdisp 6), and the pair of leads selected at 3 a.m. in which the longest and shortest QT intervals were found in each individual subject (QTdisp 2). Results: A preliminary methodological study including measurements from every minute in 10 subjects revealed no significant circadian variation using mean values of QTdisp 12, QTdisp 6, or QTdisp 2 obtained every hour, every 2, or every 4 hours, except in QTdisp 6, which demonstrated a significant circadian variation (P < 0.01) in 1-hour measurements. Analysis of all 95 subjects using measurements obtained every 4 hours revealed a significant circadian variation in QTdisp 12 and QTdisp 6 (P < 0.0001), whereas no circadian variation was seen in QTdisp 2. A subdivision into 10-year age groups revealed that subjects at age >50 years had a significant circadian variation in QTdisp 12 and QTdisp 6, but not in QTdisp 2. Only in males a significant circadian variation was seen in QTdisp 12 (P < 0.0001), whereas QTdisp 6 demonstrated a circadian variation both in females (P < 0.001) and in males (P < 0.0001). Conclusions: Selection of leads is of crucial importance for repetitive measurements of QT dispersion. Circadian variation was detected in subjects over 50 years of age, when all 12 or only the 6 precordial leads were taken into account. [source]


    Autonomic Function during Closed Loop Stimulation and Fixed Rate Pacing: Heart Rate Variability Analysis from 24-Hour Holter Recordings

    PACING AND CLINICAL ELECTROPHYSIOLOGY, Issue 3 2010
    RAFFAELE QUAGLIONE M.D.
    Aim: Aim of this retrospective study was to analyze the effect of closed-loop stimulation (CLS) and DDD pacing mode on autonomic balance, and to evaluate heart rate variability (HRV) during CLS stimulation. Methods and Materials: Autonomic balance was estimated by a 24-hour HRV analysis of paced and spontaneous beats in patients implanted with a dual-chamber pacemaker (Inos2+ CLS,Biotronik GmbH, Berlin, Germany) and randomly assigned to CLS or DDD pacing mode. Patients underwent two 24-hour electrocardiogram Holter recordings at the end of each 3-month pacing mode period. Each Holter recording was automatically scanned to extract sequences of consecutive beats of the same type [atrial paced (Ap)-sequence and atrial spontaneous (As)-sequence], lasting at least 130 beats. Results: Eight hundred and ten sequences were extracted from 15 patients, and the following spectral parameters were evaluated during both CLS and DDD mode: the total power (variance), the absolute and percentage (relative to the total power) powers of the low frequency (LF, 0.04,0.15 Hz) and high frequency (HF, 0.15,0.4 Hz) components, as well as the LF/HF power ratio. Discussion: The two main findings of this study were: in all the patients, CLS seems to mimic short-term physiological HRV, although the variability (total power) was lower than that relative to the spontaneous beats; the HRV of the spontaneous beats had an higher LF/HF when the pacemaker was programmed as DDD respect to CLS, consistent with a shift toward sympathetic predominance. PACE 2010; 33:337,342) [source]


    Steady-State versus Non-Steady-State QT-RR Relationships in 24-hour Holter Recordings

    PACING AND CLINICAL ELECTROPHYSIOLOGY, Issue 3 2000
    GILLES LANDE
    The aim of the present study was to investigate the QT-RR interval relationship in ambulatory ECG recordings with special emphasis on the physiological circumstances under which the QT-RR intervals follow a linear relation. Continuous ECG recordings make it possible to automatically measure QT duration in individual subjects under various physiological circumstances. However, identification of QT prolongation in Holter recordings is hampered by the rate dependence of QT duration. Comparison of QT duration and QT interval rate dependence between different individuals implies that the nature of the QT-RR relationship is defined in ambulatory ECG. Holter recordings were performed in healthy volunteers at baseline and after administration of dofetilide, a Class III antiarrhythmic drug. After dofetilide, beat-to-beat automated QT measurements on Holter tapes were compared with manually measured QT intervals on standard ECGs matched by time. The QT-RR relationship was analyzed at baseline in individual and group data during three different periods: 24-hour, daytime, and nighttime. Data were collected under steady-state or non-steady-state conditions of cycle length and fitted with various correction formulae. Our study demonstrated an excellent agreement between manually and automated measurements. The classic Bazett correction formula did not fit the QT-RR data points in individual or group data. When heart beats were selected for a steady rhythm during the preceding minute, QT-RR intervals fit a linear relationship during the day and night periods, but not during the 24-hour period in both individual and group data. In contrast, in the absence of beat selection, data fit a more complex curvilinear relationship irrespective of the period. Our study provides the basis for comparison of QT interval durations and QT-RR relationships between individuals and between groups of subjects. [source]


    Automatic Extraction of ECG Strips from Continuous 12-lead Holter Recordings for QT Analysis at Prescheduled versus Optimized Time Points

    ANNALS OF NONINVASIVE ELECTROCARDIOLOGY, Issue 2009
    Fabio Badilini Ph.D.
    Background: Continuous 12-lead ECG monitoring (Holter) in early-phase pharmaceutical studies is today widely used as an ideal platform to extract discrete ECGs for analysis. The extraction process is typically performed manually by trained readers using commercial Holter processing systems. Methods: Antares, a novel method for automatic 12-lead extraction from continuous Holter recordings applying minimal noise criteria and heart-rate stability conditions is presented. A set of 12-lead Holter recordings from healthy subjects administered with sotalol is used to compare ECG extractions at fixed time points with ECG extractions generated by Antares optimizing noise and heart rate inside 5 minute windows centered around each expected time point of interest. Results: Global, low- and high-frequency noise content of extracted ECGs was significantly reduced via optimized approach by Antares. Heart rate was also slightly reduced (from 69 ± 13 to 64 ± 13 bpm, P < 0.05). Similarly, the corrected QT interval from optimized extractions was significantly reduced (QTcB from 414 ± 32 to 402 ± 30 ms, P < 0.05). Using only baseline data, and after adjusting for intersubject variability, the standard deviation (SD) of QT intervals was highly reduced with optimized extraction (SD of QTcF from 11 ± 8 to 7 ± 2 ms, P < 0.05). Conclusions: Extraction of discrete 12-lead ECG strips from continuous Holter generates less noisy and more stable ECGs leading to more robust QTc data, thereby potentially facilitating the assessment of ECG effects on clinical trials. [source]


    Ablation of Focally Induced Atrial Fibrillation:

    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, Issue 2 2004
    Selective or Extensive?
    Introduction: Focally induced atrial fibrillation (AF) often is due to ectopic activity in the pulmonary veins (PV). Although initial approaches were aimed at ablating only the ectopic foci, more extensive ablation approaches have evolved that isolate all PVs empirically and/or create circumferential ablation lines in the left atrium (LA). These techniques last longer and may be associated with more risks. We retrospectively evaluated the outcome and risks of ablation for focally induced AF in a single-center patient population. Methods and Results: We report on 47 patients (32 men and 15 women; age 47 ± 10 years) in whom 52 ablations were performed. In 19 patients (22 sessions), ablation was directed at the site(s) of overt ectopic activity ("selective" group), whereas in 28 patients (30 sessions) without sufficient ectopy to determine the culprit PV a mean of 3.5 PVs were empirically targeted for bidirectional disconnection from the LA ("extensive" group). On a preprocedural Holter recording, the "selective" group had significantly more isolated atrial ectopy (3,276 ± 2,933 vs 620 ± 937 beats/24 hours) and runs of atrial tachycardia (330 ± 202 vs 53 ± 87 runs/24 hours) than the "extensive" group (P < 0.01 for both). Only 11% had persistent AF before ablation. Acute procedural success was 81% (elimination of all ectopy) and 83%, respectively (bidirectional and fully circumferential isolation of all targeted PVs). Procedure and fluoroscopy times were significantly shorter in the "selective" group. There were no major complications, but 7 minor complications and 2 acute PV stenoses > 50% in the 30 "extensive" procedures were observed. Mean follow-up was 8.4 ± 8.5 months (median 6.9). Kaplan-Meier analysis, excluding recurrences during only the first month ("delayed cure"), showed AF recurrence in 45% after 6 months and in 55% after 1 year. Outcome was not dependent on ablation approach ("selective" or "extensive") nor was time to first AF (22 ± 64 days and 30 ± 69 days). AF recurrence tended to be higher in patients with larger LA (P = 0.08), underlying heart disease or hypertension (P = 0.08), and those "extensive" patients in whom not all 4 PVs were targeted (P = 0.07). Conclusion: Trigger-directed ablation for focally induced AF is associated with a relatively high recurrence rate during follow-up. Apart from recurrence of the ectopic trigger, this may point to underlying structural changes in the atrial substrate not addressed by the ablation. Prospective evaluation of the risk-to-benefit profile of any technique (selective, extensive, including linear lines) is required. (J Cardiovasc Electrophysiol, Vol. 15, pp. 200-205, February 2004) [source]


    Combination Therapy with Digoxin and Diltiazem Controls Ventricular Rate in Chronic Atrial Fibrillation in Dogs Better than Digoxin or Diltiazem Monotherapy: A Randomized Crossover Study in 18 Dogs

    JOURNAL OF VETERINARY INTERNAL MEDICINE, Issue 3 2009
    A.R.M. Gelzer
    Background: Atrial fibrillation (AF) with excessively high ventricular rates (VR) occurs in dogs with advanced heart disease. Rate control improves clinical signs in these patients. Optimal drug therapy and target VR remain poorly defined. Hypothesis: Digoxin-diltiazem combination therapy reduces VR more than either drug alone in dogs with high VR AF. Animals: Eighteen client-owned dogs (>15 kg) with advanced heart disease, AF, and average VR on 24-hour Holter > 140 beats per minute (bpm). Methods: After baseline Holter recording, dogs were randomized to digoxin or diltiazem monotherapy, or combination therapy. Repeat Holter evaluation was obtained after 2 weeks; dogs were then crossed over to the other arm (monotherapy or combination therapy) for 2 weeks and a third Holter was acquired. Twenty-four hour average VR, absolute and relative VR changes from baseline, and percent time spent within prespecified VR ranges (>140, 100,140, and <100 bpm) were compared. Correlations between serum drug concentrations and VR were examined. Results: Digoxin (median, 164 bpm) and diltiazem (median, 158 bpm) decreased VR from baseline (median, 194 bpm) less than the digoxin-diltiazem combination (median, 126 bpm) (P < .008 for each comparison). With digoxin-diltiazem, VR remained <140 bpm for 85% of the recording period, but remained >140 bpm for 88% of the recording period with either monotherapy. Serum drug concentrations did not correlate with VR. Conclusions and Clinical Importance: At the dosages used in this study, digoxin-diltiazem combination therapy provided a greater rate control than either drug alone in dogs with AF. [source]


    Autonomic Function during Closed Loop Stimulation and Fixed Rate Pacing: Heart Rate Variability Analysis from 24-Hour Holter Recordings

    PACING AND CLINICAL ELECTROPHYSIOLOGY, Issue 3 2010
    RAFFAELE QUAGLIONE M.D.
    Aim: Aim of this retrospective study was to analyze the effect of closed-loop stimulation (CLS) and DDD pacing mode on autonomic balance, and to evaluate heart rate variability (HRV) during CLS stimulation. Methods and Materials: Autonomic balance was estimated by a 24-hour HRV analysis of paced and spontaneous beats in patients implanted with a dual-chamber pacemaker (Inos2+ CLS,Biotronik GmbH, Berlin, Germany) and randomly assigned to CLS or DDD pacing mode. Patients underwent two 24-hour electrocardiogram Holter recordings at the end of each 3-month pacing mode period. Each Holter recording was automatically scanned to extract sequences of consecutive beats of the same type [atrial paced (Ap)-sequence and atrial spontaneous (As)-sequence], lasting at least 130 beats. Results: Eight hundred and ten sequences were extracted from 15 patients, and the following spectral parameters were evaluated during both CLS and DDD mode: the total power (variance), the absolute and percentage (relative to the total power) powers of the low frequency (LF, 0.04,0.15 Hz) and high frequency (HF, 0.15,0.4 Hz) components, as well as the LF/HF power ratio. Discussion: The two main findings of this study were: in all the patients, CLS seems to mimic short-term physiological HRV, although the variability (total power) was lower than that relative to the spontaneous beats; the HRV of the spontaneous beats had an higher LF/HF when the pacemaker was programmed as DDD respect to CLS, consistent with a shift toward sympathetic predominance. PACE 2010; 33:337,342) [source]


    Impact and Prevention of Far-Field Sensing in Fallback Mode Switches

    PACING AND CLINICAL ELECTROPHYSIOLOGY, Issue 1p2 2003
    PIERRE BORDACHER
    BORDACHAR, P., et al.: Impact and Prevention of Far-Field Sensing in Fallback Mode Switches.Far-field oversensing (FFOS) promoted by high atrial sensitivity and short atrial refractory periods induces false positive mode switches. We evaluated the incidence of ventricular FFOS in a population of DDD paced patients. Methods: One hundred thirty-seven patients (71 ± 10years, 76 men) implanted with a Talent DR pacemaker were studied. Before discharge, an analysis of internal data stored in the memories of the PM was performed by the specific software incorporated in the programmer in parallel with a 24-hour Holter recording. Data were validated by a panel of experts. One and 4 months follow-up was based only on the data stored in the PM memories. Results: Pacing indications were atrioventricular block(n = 75), sinus node dysfunction(n = 57), and other(n = 5). Sustained far-field oversensing was observed in 12/137 patients (9%). Out of a total of 3,511 triggered mode switch episodes, FFOS accounted for 20% and 7% of a 311 days cumulative time in mode switch. Inappropriate mode switch episodes induced by far-field were more numerous but shorter than episodes prompted by atrial arrhythmias. Atrial sensitivity was increased in eight patients, successfully in four. Reprogramming of the atrial refractory period(156 ± 11 ms)was successful in five of six patients. Conclusions: A 9% rate of ventricular FFOS was observed in an unselected population, easily and automatically diagnosed using the internal memory function and the automatic analysis provided by the programmer. Prolongation of the atrial refractory period was more effective than resetting of the atrial sensitivity in eliminating FFOS. (PACE 2003; 26[Pt. II]:206,209) [source]


    Predictors of Long-Term Risk for Heart Failure Hospitalization after Acute Myocardial Infarction

    ANNALS OF NONINVASIVE ELECTROCARDIOLOGY, Issue 3 2010
    Juha S. Perkiömäki M.D.
    Background: Data on the value of baseline brain natriuretic peptide (BNP) and autonomic markers in predicting heart failure (HF) hospitalization after an acute myocardial infarction (AMI) are limited. Methods: A consecutive series of patients with AMI without a previous history of HF (n = 569) were followed up for 8 years. At baseline, the patients had a blood sample for determination of BNP, a 24-hour Holter recording for evaluating heart rate variability (HRV) and heart rate turbulence (HRT), and an assessment of baroreflex sensitivity (BRS) using phenylephrine test. Results: During the follow-up, 79 (14%) patients were hospitalized due to HF. Increased baseline BNP, decreased HRV, HRT, and BRS had a significant association with HF hospitalization in univariate comparisons (P < 0.001 for all). After adjusting with all the relevant clinical parameters, BNP, HRV, and HRT still significantly predicted HF hospitalization (P < 0.001 for BNP and for the short-term scaling exponent ,1, P < 0.01 for turbulence slope). In the receiver operator characteristics curve analysis, the area under the curve for BNP was 0.77, for the short-term scaling exponent ,1 0.69, for turbulence slope 0.71, and for BNP/standard deviation of all N-N intervals ratio 0.80. Conclusion: Baseline increased BNP and impaired autonomic function after AMI yield significant information on the long-term risk for HF hospitalization. Ann Noninvasive Electrocardiol 2010;15(3):250,258 [source]


    Impact of Preceding Ventricular Premature Beats on Heart Rate Turbulence

    ANNALS OF NONINVASIVE ELECTROCARDIOLOGY, Issue 4 2009
    Hung Yi Chen M.D.
    Background: Heart rate turbulence (HRT) has recently been introduced as a noninvasive tool for studying autonomic dysfunction. It presented short time fluctuation of sinus cycle length following single ventricular premature contraction (VPC). However, HRT parameters may be influenced by different factors. This study aimed to evaluate the possible influence of VPC frequency on HRT. Methods: 24-h Holter recording was performed in patients with VPCs initially detected by 12-lead electrocardiography (ECG) in the outpatient department. The numbers of VPCs in 2- and 5-minute durations preceding each VPC tachogram were calculated. The HRT parameters and the numbers of the VPCs preceding VPC tachograms were analyzed. Results: There were 23,122 available VPC tachograms from 107 healthy subjects included in the study. The turbulence onset (TO) value increased and the turbulence slope (TS) value decreased as VPC's frequency increased. The TO values rapidly increased when the number of VPCs was >15 beats in the 2-minute and >35 beats in the 5-minute durations. There was also a prominent decrease in TS values when the VPCs reached 14 and 30 beats in the 2- and 5-minute durations, respectively. Conclusion: Physiologic baroreflex may be attenuated under intensive stimulation, which is evidenced by blunted HRT parameters by frequent VPCs. Physiologic response to VPC's frequency may be related to baroreflex fatigue and is demonstrated as a sigmoid curve. [source]


    Diagnostic Performance of Various QTc Interval Formulas in a Large Family with Long QT Syndrome Type 3: Bazett's Formula Not So Bad After All ,

    ANNALS OF NONINVASIVE ELECTROCARDIOLOGY, Issue 4 2003
    Jan Brouwer M.D., M.Sc., Ph.D.
    Background: Recently, we identified a novel mutation of SCN5A (1795insD) in a large family with LQTS3. The aim of this study was to assess whether the various proposed corrections of the QT interval to heart rate help to improve the identification of carriers of the mutant gene. Methods: The study group consisted of 101 adult family members: 57 carriers and 44 noncarriers (mean age 44.6 ± 14.6 and 40.3 ± 12.8 years, respectively). In all individuals a 12-lead ECG, exercise ECG, and 24-hour Holter ECG were obtained. Results: Correction for heart rate significantly improved the diagnostic performance of the QT interval. Diagnostic performance of the Bazett formula was similar to that of the newer formulas (Fridericia, Hodges, Framingham, and a logarithmic formula). At a cut-off value of 440 ms, the Bazett corrected QT interval was associated with a sensitivity and specificity of 90% and 91%, respectively. Using the 24-hour Holter ECG, a prolonged QTc at heart rates less than 60 beats/min was almost pathognomonic for genetic mutation (sensitivity and specificity both 99%), whereas the QTc calculated at the lowest heart rate using Bazett's formula provided full discrimination. Conclusion: In the present family, the resting ECG gave a good indication about the presence or absence of genetic mutation but a 24-hour Holter recording was mandatory to ascertain the diagnosis. In the diagnosis of this form of LQTS3, Bazett's formula was at least as good as other proposed corrections of the QT interval to heart rate. [source]


    Impact of body fat mass extent on cardiac autonomic alterations in women

    EUROPEAN JOURNAL OF CLINICAL INVESTIGATION, Issue 8 2009
    J. Sztajzel
    Abstract Background, Obesity has been associated with significant abnormalities of the cardiac autonomic regulation. However, the precise impact of increasing body weight on cardiac autonomic function and the metabolic and hormonal contributors to these changes are presently unclear. The aim of our study was to explore in subjects with increasing values of body mass index (BMI) the alterations of cardiac autonomic function and to establish the potential role of various metabolic and hormonal contributors to these alterations. Materials and methods, We investigated time and frequency domain heart rate variability (HRV) parameters taken from 24-h Holter recordings, and several anthropometric, metabolic and hormonal parameters (plasma glucose, insulin, triglycerides, free fatty acids, leptin and adiponectin) in 68 normoglycaemic and normotensive women (mean age of 40 ± 3 years), subdivided according to their BMI into 15 normal body weight (controls), 15 overweight, 18 obese and 20 morbidly obese. Results, Heart rate was increased and HRV was decreased in the morbidly obese group as compared with controls. In overall population, a negative association linked body fat mass (FM) to HRV indices. None of the metabolic and hormonal parameters were significantly related to the HRV indices, after they were adjusted for the body FM. Conclusions, Morbidly obese, normoglycaemic and normotensive young women have increased HR and low HRV, indicating an abnormal cardiac autonomic function and representing a risk factor for adverse cardiovascular events. A decrease of HRV parameters is associated with a progressive increase of body FM. Other metabolic and hormonal factors, characterising obesity, do not show an independent influence on these HRV alterations. [source]


    Novel Measures of Heart Rate Variability Predict Cardiovascular Mortality in Older Adults Independent of Traditional Cardiovascular Risk Factors: The Cardiovascular Health Study (CHS)

    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, Issue 11 2008
    PHYLLIS K. STEIN Ph.D.
    Background: It is unknown whether abnormal heart rate turbulence (HRT) and abnormal fractal properties of heart rate variability identify older adults at increased risk of cardiovascular death (CVdth). Methods: Data from 1,172 community-dwelling adults, ages 72 ± 5 (65,93) years, who participated in the Cardiovascular Health Study (CHS), a study of risk factors for CV disease in people ,65 years. HRT and the short-term fractal scaling exponent (DFA1) derived from 24-hour Holter recordings. HRT categorized as: normal (turbulence slope [TS] and turbulence onset [TO] normal) or abnormal (TS and/or TO abnormal). DFA1 categorized as low (,1) or high (>1). Cox regression analyses stratified by Framingham Risk Score (FRS) strata (low = <10, mid = 10,20, and high >20) and adjusted for prevalent clinical cardiovascular disease (CVD), diabetes, and quartiles of ventricular premature beat counts (VPCs). Results: CVdths (N = 172) occurred over a median follow-up of 12.3 years. Within each FRS stratum, low DFA1 + abnormal HRT predicted risk of CVdth (RR = 7.7 for low FRS; 3.6, mid FRS; 2.8, high FRS). Among high FRS stratum participants, low DFA1 alone also predicted CVdth (RR = 2.0). VPCs in the highest quartile predicted CVdth, but only in the high FRS group. Clinical CV disease predicted CVdth at each FRS stratum (RR = 2.9, low; 2.6, mid; and 1.9, high). Diabetes predicted CVdth in the highest FRS group only (RR = 2.2). Conclusions: The combination of low DFA1 + abnormal HRT is a strong risk factor for CVdth among older adults even after adjustment for conventional CVD risk measures and the presence of CVD. [source]


    Nonlinear Indices of Heart Rate Variability in Chronic Heart Failure Patients: Redundancy and Comparative Clinical Value

    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, Issue 4 2007
    ROBERTO MAESTRI M.S.
    Aims: We aimed to assess the mutual interrelationships and to compare the prognostic value of a comprehensive set of nonlinear indices of heart rate variability (HRV) in a population of chronic heart failure (CHF) patients. Methods and Results: Twenty nonlinear HRV indices, representative of symbolic dynamics, entropy, fractality-multifractality, predictability, empirical mode decomposition, and Poincaré plot families, were computed from 24-hour Holter recordings in 200 stable CHF patients in sinus rhythm (median age [interquartile range]: 54 [47,58] years, LVEF: 23 [19,28]%, NYHA class II,III: 88%). End point for survival analysis (Cox model) was cardiac death or urgent transplantation. Homogeneous variables were grouped by cluster analysis, and in each cluster redundant variables were discarded. A prognostic model including only known clinical and functional risk factors was built and the ability of each selected HRV variable to add prognostic information to this model assessed. Bootstrap resampling was used to test the models stability. Four nonlinear variables showed a correlation >0.90 with classical linear ones and were discarded. Correlations >0.80 were found between several nonlinear variables. Twelve clusters were obtained and from each cluster a candidate predictor was selected. Only two variables (from empirical mode decomposition and symbolic dynamics families) added prognostic information to the clinical model. Conclusion: This exploratory study provides evidence that, despite some redundancies in the informative content of nonlinear indices and strong differences in their prognostic power, quantification of nonlinear properties of HRV provides independent information in risk stratification of CHF patients. [source]


    Clustering of RR Intervals Predicts Effective Electrical Cardioversion for Atrial Fibrillation

    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, Issue 9 2004
    MAARTEN P. VAN DEN BERG M.D.
    Introduction: Atrial fibrillation (AF) is characterized by an irregularly irregular ("random") heart beat. However, controversy exists whether the ventricular rhythm in AF is truly random. We investigated randomness by constructing three-dimensional RR interval plots (3D plots), allowing identification of "clustering" of RR intervals. It was hypothesized that electrical cardioversion (ECV) would be more effective in AF patients with clustering, because clustering might reflect a higher degree of organization of atrial fibrillatory activity. Methods and Results: The study group consisted of 66 patients (44 men and 22 women; mean age 68 ± 11 years,) who were referred for ECV because of persistent AF. Twenty-four-hour Holter recordings were used to construct 3D plots by plotting each RR interval (x axis) against the previous RR interval (y axis) and the number of occurrences of each of these x,y combinations (z axis). A clustering index was calculated as the percentage of beats within the peaks in the 3D plot. Based on the 3D plots, clustering of RR intervals was present in 31 (47%) of the 66 patients. ECV was effective in restoring sinus rhythm in 29 (94%) of these 31 patients, whereas sinus rhythm was restored in only 25 (71%) of the remaining 35 patients without clustering (P = 0.020). The clustering index ranged from <2% in the 12 patients with failed ECV to >8% in the 32 patients with sinus rhythm at the end of the study (4 weeks after the ECV); the clustering index in the 22 patients with a relapse of AF after effective ECV was intermediate (P = 0.034 and P = 0.042, respectively). Conclusion: This study indicates that ECV is more effective in restoring sinus rhythm in AF patients with clustering compared to patients in whom no clustering is apparent on 3D plots. In addition, the degree of clustering appears to be predictive of the overall outcome of ECV; the higher the degree of clustering, the higher the likelihood of sinus rhythm at follow-up. [source]


    Interleukin-6 Levels are Inversely Correlated with Heart Rate Variability in Patients with Decompensated Heart Failure

    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, Issue 3 2001
    DORON ARONSON M.D.
    Interleukin-6 and Heart Rate Variability.Introduction: Increased local and systemic elaboration of cytokines have an important role in the pathogenesis of congestive heart failure (CHF) through diverse mechanisms. Because cytokines are known to act at the neuronal level in both the peripheral and central nervous system, we sought to determine whether increased cytokine levels are associated with the autonomic dysfunction that characterizes CHF. Methods and Results: We studied 64 patients admitted for decompensated CHF (mean age 59 ± 12 years). Autonomic function was assessed using time, and frequency-domain heart rate variability (HRV) measures, obtained from 24-hour Holter recordings. In addition, norepinephrine, tumor necrosis factor-, (TNF-,), and interleukin-6 (IL-6) were measured in all patients. TNF-, levels did not correlate with any of the HRV measures. IL-6 inversely correlated with the time-domain parameters of standard deviation of RR intervals (SDNN) (r =,0.36, P = 0.004) and standard deviation of all 5,minute mean RR intervals (SDANN) (r =,0.39, P = 0.001), and with the frequency-domain parameters of total power (TP) (r =,0.37, P = 0.003) and ultralow-frequency (ULF) power (r =,0.43, P = 0.001). No correlation was found between IL-6 and indices of parasympathetic modulation. Using multiple linear regression models, adjusting for clinical variables and drug therapies, the strong inverse relationship between IL-6 and SDNN (P = 0.006), SDANN (P = 0.001), TP (P = 0.04), and ULF power (P = 0.0007) persisted. Conclusion: Reduction of long-term HRV indices is associated with increased levels of IL-6 in patients with decompensated heart failure. The ability of long-term HRV parameters to better reflect activation of diverse hormonal systems may explain their greater prognostic power for risk stratification in patients with CHF. [source]


    Gender-Related Differences in Modulation of Heart Rate in Patients with Congestive Heart Failure

    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, Issue 10 2000
    DORON ARONSON M.D.
    Gender and HRV in Heart Failure Introduction. The prognosis of women with congestive heart failure (CHF) is better than that for men, but the mechanisms underlying the female survival advantage are not well understood. CHF is characterized by profound abnormalities in cardiac autonomic control that contribute to progressive circulatory failure and influence survival. Methods and Results. Time- and frequency-domain heart rate variability (HRV) indexes were obtained from 24-hour Holter recordings and compared to assess the role of gender in 131 men and 68 women with CHF (mean age 60 ± 13.6 years, range 21 to 87; New York Heart Association Functional Class III [66%] and IV [34%]). Gender-related differences in HRV were observed only in the subset of patients with nonischemic heart failure (55 men and 39 women). Among the time-domain indexes, the SD of the RR intervals (76 ± 5.3 msec vs 55.3 ± 3.2 msec, P < 0.0001) and indexes denoting parasympathetic modulation, the percentage of RR intervals with >50 msec variation (4.0%± 1.0% vs 6.5%± 1.3%, P = 0.02), and the square root of mean squared differences of successive RR intervals (19.1 ± 3.3 vs 28.4 ± 3.8, P = 0.004) were higher in women. Among the frequency-domain indexes, the total power (7.5 ± 0.13 In-msec2 vs 8.3 ± 0.14 In-msec2, P = 0.0002), the ultralow-frequency power (7.2 ± 0.11 In-msec2 vs 8.0 ± 0.14 In-msec2, P < 0.0001), the low-frequency power (3.8 ± 0.25 In-msec2 vs 4.8 ± 0.28 In-msec2, P = 0.006), and the high-frequency power (3.8 ± 0.24 In-msec2, vs 4.6 ± 0.26 In-msec2, P = 0.003) were greater in women than in men. Conclusion. Women with nonischemic CHF have an attenuated sympathetic activation and parasympathetic withdrawal compared with men. Gender-based differences in autonomic responses in the setting of CHF may be related to the female survival advantage. (J Cardiovasc Electrophysiol, Vol. 11, pp. 1071-1077, October 2000) [source]


    Incidence of post-anaesthetic arrhythmias in dogs

    JOURNAL OF SMALL ANIMAL PRACTICE, Issue 3 2005
    K. Buhl
    Objectives: To assess the use of Holter monitoring for evaluating the incidence of post-anaesthetic cardiac arrhythmias and associated anaesthetic risk for two different anaesthetic protocols. Methods: Patients undergoing orthopaedic surgery were randomly divided into two groups with different anaesthetic regimens (group A, isoflurane n=30; group B, propofol n=30). Two 24-hour Holter recordings were performed for each patient: the first directly following anaesthesia and the second, as a comparison, on the fifth postoperative day. Results: Although all dogs were healthy on pre-anaesthetic cardiac evaluation, 56 dogs showed arrhythmias in the two 24-hour (Holter) electrocardiograms performed. However, the number of arrhythmias recorded was low in most cases (less than 10 supraventricular extrasystoles and less than 100 ventricular extrasystoles). One patient in group A showed 94 supraventricular extrasystoles during the second monitoring period. Three patients in each group developed more than 100 ventricular extrasystoles during both Holter recordings. There were no statistically significant differences between the two anaesthetic regimens or between the two recordings in both groups. Clinical Significance: The two anaesthetic protocols investigated in this study did not induce an increased incidence of severe arrhythmias in healthy dogs in the post-anaesthetic phase. [source]


    Autonomic Function during Closed Loop Stimulation and Fixed Rate Pacing: Heart Rate Variability Analysis from 24-Hour Holter Recordings

    PACING AND CLINICAL ELECTROPHYSIOLOGY, Issue 3 2010
    RAFFAELE QUAGLIONE M.D.
    Aim: Aim of this retrospective study was to analyze the effect of closed-loop stimulation (CLS) and DDD pacing mode on autonomic balance, and to evaluate heart rate variability (HRV) during CLS stimulation. Methods and Materials: Autonomic balance was estimated by a 24-hour HRV analysis of paced and spontaneous beats in patients implanted with a dual-chamber pacemaker (Inos2+ CLS,Biotronik GmbH, Berlin, Germany) and randomly assigned to CLS or DDD pacing mode. Patients underwent two 24-hour electrocardiogram Holter recordings at the end of each 3-month pacing mode period. Each Holter recording was automatically scanned to extract sequences of consecutive beats of the same type [atrial paced (Ap)-sequence and atrial spontaneous (As)-sequence], lasting at least 130 beats. Results: Eight hundred and ten sequences were extracted from 15 patients, and the following spectral parameters were evaluated during both CLS and DDD mode: the total power (variance), the absolute and percentage (relative to the total power) powers of the low frequency (LF, 0.04,0.15 Hz) and high frequency (HF, 0.15,0.4 Hz) components, as well as the LF/HF power ratio. Discussion: The two main findings of this study were: in all the patients, CLS seems to mimic short-term physiological HRV, although the variability (total power) was lower than that relative to the spontaneous beats; the HRV of the spontaneous beats had an higher LF/HF when the pacemaker was programmed as DDD respect to CLS, consistent with a shift toward sympathetic predominance. PACE 2010; 33:337,342) [source]


    Impact of Fusion Avoidance on Performance of the Automatic Threshold Tracking Feature in Dual Chamber Pacemakers: A Multicenter Prospective Randomized Study

    PACING AND CLINICAL ELECTROPHYSIOLOGY, Issue 11 2002
    RETO CANDINAS
    CANDINAS, R., et al.: Impact of Fusion Avoidance on Performance of the Automatic Threshold Tracking Feature in Dual Chamber Pacemakers: A Multicenter Prospective Randomized Study. The Autocapture algorithm enables automatic capture verification on a beat-by-beat basis by recognizing the evoked response signal following each pacemaker stimulus. The algorithm intends to increase patient safety while decreasing energy consumption. However, the occurrence of fusion beats, particularly during dual chamber pacing, may limit the energy saving effect of Autocapture. The aim of this multicenter, prospective, randomized study was to evaluate the impact of the Fusion Avoidance (FA) algorithm on the incidence of fusion beats. Thirty-eight patients (mean age 69 ± 13 years) with intrinsic AV conduction who were implanted with an Affinity DR were studied. After programming a PV/AV delay of 120/190 ms, patients were randomized to FA On or Off. Each group was further randomized with respect to activation of the AutoIntrinsic Conduction Search (AICS) algorithm. The total number of beats, ventricular paced beats, fusion beats, backup pulses, and threshold searches were analyzed from 24-hour Holter recordings. The number of total beats was comparable in both FA groups. The number of total ventricular paced beats, fusion beats, backup pulses, and threshold searches were significantly reduced in the FA On group (% reduction: 68% P < 0.001, 75% P < 0.01, 95% P < 0.01, and 94% P < 0.05, respectively). The number of ventricular paced beats with full capture was significantly reduced when AICS was activated (P < 0.05). In conclusion, the FA algorithm substantially reduces the amount of ventricular paced beats, fusion beats, unnecessary backup pulses and threshold searches, and therefore, provides added benefits in energy saving obtained by Autocapture. [source]


    24-Hour Heart Rate Variability in Patients with Vasovagal Syncope

    PACING AND CLINICAL ELECTROPHYSIOLOGY, Issue 4 2000
    CHIARA LAZZERI
    Since alterations in the autonomic nervous system are thought to play a major role in the pathogenesis of vasovagal syncope, we characterized the chronic autonomic profile of 44 patients with syncope and 20 healthy subjects by means of heart rate variability using 24-hour Holter recordings (time- and frequency-domain indexes), and evaluated whether the different types of responses to tilting (vasodepressive versus cardioinhibitory) could be associated with different cardiac autonomic patterns. Twenty-three patients exhibited a positive response to tilting, which was vasodepressive in 11 patients and cardioinhibitory in 12 patients. All vasodepressive patients had a standard deviation of the averages of NN (SDANN) intervals in all 5-minute segments lower than 100 ms. Patients with vasodepressive syncope also had significantly lower values of RMSSD (the 24-hour square root of the mean of the sum of the squares of differences between adjacent normal RR intervals) than those with cardioinhibitory response, and lacked the day-night rhythm of the low frequency/high frequency ratio. However, only SDANN values correctly identified patients with vasodepressive response to tilting. We conclude that (1) the population of patients with vasovagal syncope is heterogeneous, (2) patients with vasodepressive syncope have a peculiar chronic autonomic profile as assessed by 24-hour heart rate variability analysis, and (3) the evaluation of the autonomic profile in 24-hour Holter recordings could be of value in the diagnosis of patients with syncope. [source]


    Steady-State versus Non-Steady-State QT-RR Relationships in 24-hour Holter Recordings

    PACING AND CLINICAL ELECTROPHYSIOLOGY, Issue 3 2000
    GILLES LANDE
    The aim of the present study was to investigate the QT-RR interval relationship in ambulatory ECG recordings with special emphasis on the physiological circumstances under which the QT-RR intervals follow a linear relation. Continuous ECG recordings make it possible to automatically measure QT duration in individual subjects under various physiological circumstances. However, identification of QT prolongation in Holter recordings is hampered by the rate dependence of QT duration. Comparison of QT duration and QT interval rate dependence between different individuals implies that the nature of the QT-RR relationship is defined in ambulatory ECG. Holter recordings were performed in healthy volunteers at baseline and after administration of dofetilide, a Class III antiarrhythmic drug. After dofetilide, beat-to-beat automated QT measurements on Holter tapes were compared with manually measured QT intervals on standard ECGs matched by time. The QT-RR relationship was analyzed at baseline in individual and group data during three different periods: 24-hour, daytime, and nighttime. Data were collected under steady-state or non-steady-state conditions of cycle length and fitted with various correction formulae. Our study demonstrated an excellent agreement between manually and automated measurements. The classic Bazett correction formula did not fit the QT-RR data points in individual or group data. When heart beats were selected for a steady rhythm during the preceding minute, QT-RR intervals fit a linear relationship during the day and night periods, but not during the 24-hour period in both individual and group data. In contrast, in the absence of beat selection, data fit a more complex curvilinear relationship irrespective of the period. Our study provides the basis for comparison of QT interval durations and QT-RR relationships between individuals and between groups of subjects. [source]


    Heart Rate Turbulence for Prediction of Heart Transplantation and Mortality in Chronic Heart Failure

    ANNALS OF NONINVASIVE ELECTROCARDIOLOGY, Issue 3 2010
    Beata Sredniawa M.D.
    Background: Previous studies have shown conflicting results about the value of heart rate turbulence (HRT) for risk stratification of patients (pts) with chronic heart failure (CHF). We prospectively evaluated the relation between HRT and progression toward end-stage heart failure or all-cause mortality in patients with CHF. Methods: HRT was assessed from 24-hour Holter recordings in 110 pts with CHF (54 in NYHA class II, 56 in class III,IV; left ventricular ejection fraction (LVEF) 30%± 10%) on optimal pharmacotherapy and quantified as turbulence onset (TO,%), turbulence slope (TS, ms/RR interval), and turbulence timing (beginning of RR sequence for calculation of TS, TT). TO , 0%, TS , 2.5 ms/RR, and TT >10 were considered abnormal. End point was development of end-stage CHF requiring heart transplantation (OHT) or all-cause mortality. Results: During a follow-up of 5.8 ± 1.3 years, 24 pts died and 10 required OHT. TO, TS, TT, and both (TO and TS) were abnormal in 35%, 50%, 30%, and 25% of all patients, respectively. Patients with at least one relatively preserved HRT parameter (TO, TS, or TT) (n = 98) had 5-year event-free rate of 83% compared to 33% of those in whom all three parameters were abnormal (n = 12). In multivariate Cox regression analysis, the most powerful predictor of end point events was heart rate variability (SDNN < 70 ms, hazard ratio (HR) 9.41, P < 0.001), followed by LVEF , 35% (HR 6.23), TT , 10 (HR 3.14), and TO , 0 (HR 2.54, P < 0.05). Conclusion: In patients with CHF on optimal pharmacotherapy, HRT can help to predict those at risk for progression toward OHT or death of all causes. Ann Noninvasive Electrocardiol 2010;15(3):230,237 [source]


    Influence of Heavy Cigarette Smoking on Heart Rate Variability and Heart Rate Turbulence Parameters

    ANNALS OF NONINVASIVE ELECTROCARDIOLOGY, Issue 4 2009
    Goksel Cagirci M.D.
    Background: Cigarette smoking increases the risk of cardiovascular events related with several mechanisms. The most suggested mechanism is increased activity of sympathetic nervous system. Heart rate variability (HRV) and heart rate turbulence (HRT) has been shown to be independent and powerful predictors of mortality in a specific group of cardiac patients. The goal of this study was to assess the effect of heavy cigarette smoking on cardiac autonomic function using HRV and HRT analyses. Methods: Heavy cigarette smoking was defined as more than 20 cigarettes smoked per day. Heavy cigarette smokers, 69 subjects and nonsmokers 74 subjects (control group) were enrolled in this study. HRV and HRT analyses [turbulence onset (TO) and turbulence slope (TS)] were assessed from 24-hour Holter recordings. Results: The values of TO were significantly higher in heavy cigarette smokers than control group (,1.150 ± 4.007 vs ,2.454 ± 2.796, P = 0.025, respectively), but values of TS were not statistically different between two groups (10.352 ± 7.670 vs 9.613 ± 7.245, P = 0.555, respectively). Also, the number of patients who had abnormal TO was significantly higher in heavy cigarette smokers than control group (23 vs 10, P = 0.006). TO was correlated with the number of cigarettes smoked per day (r = 0.235, P = 0.004). While LF and LF/HF ratio were significantly higher, standard deviation of all NN intervals (SDNN), standard deviation of the 5-minute mean RR intervals (SDANN), root mean square of successive differences (RMSSD), and high-frequency (HF) values were significantly lower in heavy smokers. While, there was significant correlation between TO and SDNN, SDANN, RMSSD, LF, and high frequency (HF), only HF was correlated with TS. Conclusion: Heavy cigarette smoking has negative effect on autonomic function. HRT is an appropriate noninvasive method to evaluate the effect of cigarette on autonomic function. Simultaneous abnormal HRT and HRV values may explain increased cardiovascular event risk in heavy cigarette smokers. [source]


    Automated QT Analysis That Learns from Cardiologist Annotations

    ANNALS OF NONINVASIVE ELECTROCARDIOLOGY, Issue 2009
    Iain Guy David Strachan Ph.D.
    Background: Reliable, automated QT analysis would allow the use of all the ECG data recorded during continuous Holter monitoring, rather than just intermittent 10-second ECGs. Methods: BioQT is an automated ECG analysis system based on a Hidden Markov Model, which is trained to segment ECG signals using a database of thousands of annotated waveforms. Each sample of the ECG signal is encoded by its wavelet transform coefficients. BioQT also produces a confidence measure which can be used to identify unreliable segmentations. The automatic generation of templates based on shape descriptors allows an entire 24 hours of QT data to be rapidly reviewed by a human expert, after which the template annotations can automatically be applied to all beats in the recording. Results: The BioQT software has been used to show that drug-related perturbation of the T wave is greater in subjects receiving sotalol than in those receiving moxifloxacin. Chronological dissociation of T-wave morphology changes from the QT prolonging effect of the drug was observed with sotalol. In a definitive QT study, the percentage increase of standard deviation of QTc for the standard manual method with respect to that obtained with BioQT analysis was shown to be 44% and 30% for the placebo and moxifloxacin treatments, respectively. Conclusions: BioQT provides fully automated analysis, with confidence values for self-checking, on very large data sets such as Holter recordings. Automatic templating and expert reannotation of a small number of templates lead to a reduction in the sample size requirements for definitive QT studies. [source]


    Automatic Extraction of ECG Strips from Continuous 12-lead Holter Recordings for QT Analysis at Prescheduled versus Optimized Time Points

    ANNALS OF NONINVASIVE ELECTROCARDIOLOGY, Issue 2009
    Fabio Badilini Ph.D.
    Background: Continuous 12-lead ECG monitoring (Holter) in early-phase pharmaceutical studies is today widely used as an ideal platform to extract discrete ECGs for analysis. The extraction process is typically performed manually by trained readers using commercial Holter processing systems. Methods: Antares, a novel method for automatic 12-lead extraction from continuous Holter recordings applying minimal noise criteria and heart-rate stability conditions is presented. A set of 12-lead Holter recordings from healthy subjects administered with sotalol is used to compare ECG extractions at fixed time points with ECG extractions generated by Antares optimizing noise and heart rate inside 5 minute windows centered around each expected time point of interest. Results: Global, low- and high-frequency noise content of extracted ECGs was significantly reduced via optimized approach by Antares. Heart rate was also slightly reduced (from 69 ± 13 to 64 ± 13 bpm, P < 0.05). Similarly, the corrected QT interval from optimized extractions was significantly reduced (QTcB from 414 ± 32 to 402 ± 30 ms, P < 0.05). Using only baseline data, and after adjusting for intersubject variability, the standard deviation (SD) of QT intervals was highly reduced with optimized extraction (SD of QTcF from 11 ± 8 to 7 ± 2 ms, P < 0.05). Conclusions: Extraction of discrete 12-lead ECG strips from continuous Holter generates less noisy and more stable ECGs leading to more robust QTc data, thereby potentially facilitating the assessment of ECG effects on clinical trials. [source]


    Automated QT Measurement and Application to Detection of Moxifloxacin-Induced Changes

    ANNALS OF NONINVASIVE ELECTROCARDIOLOGY, Issue 2009
    David W. Mortara Ph.D.
    Background: Concern for drug-induced QT prolongation has caused significant investment in QT measurement to safety-test new compounds. Manual methods are expensive and time-consuming. Reliable automatic methods would be highly desirable. Methods: Twelve-lead Holter recordings were annotated beat-to-beat by an automatic algorithm for global QRS onset and T offset. T offset was established from the time of peak T downslope plus a rate-dependent offset, analogous to the "tangent method," wherein T offset is determined by extrapolating the T downslope to an intersection with the baseline. Results and Conclusions: Variances of the beat-to-beat QT measurements were in the range 2.5,3.4 ms over three distinct databases, including a large heart failure database. Application to a moxifloxacin/placebo control database of 29 subjects showed excellent results. [source]


    Dynamics of Ventricular Repolarization in Patients with Dilated Cardiomyopathy Versus Healthy Subjects

    ANNALS OF NONINVASIVE ELECTROCARDIOLOGY, Issue 2 2005
    Jose Luis Alonso M.D.
    Background: Patients with impaired left ventricular function have a high risk of developing ventricular arrhythmias and sudden death. Among different markers of risk, the prolongation and regional heterogeneity of repolarization are of increasing interest. However, there are limited data regarding feasibility of analyzing repolarization parameters and their dynamics in 24-hour Holter ECG recordings. Methods: Dynamic behavior of repolarization parameters was studied with a new automatic algorithm in digital 24-hour Holter recordings of 60 healthy subjects and 55 patients with idiopathic dilated cardiomyopathy (IDC). Repolarization parameters included the mean value of QT and QTc durations, QT dispersion, and peaks of QT duration and QT dispersion above prespecified thresholds. Results: In comparison to healthy subjects, patients with IDC had lower heart rate variability, longer mean QT and QTc durations, higher content of QTc peaks >500 ms, longer QT dispersion and its standard deviation, and a higher content of peaks >100 ms of QT dispersion (P < 0.01 for all comparisons). These repolarization parameters were significantly higher in IDC patients after adjustment for age, sex, and heart rate variability. The parameters of repolarization dynamics correlated with SDNN in healthy subjects but not in dilated cardiomyopathy patients. Conclusions: The automatic assessment of repolarization parameters in 24-hour digital ECG recordings is feasible and differentiates dilated cardiomyopathy patients from healthy subjects. Patients with dilated cardiomyopathy have increased QT duration, QT dispersion, and increased variability of QT dispersion reflecting variations in T-wave morphology, the factors which might predispose them to the development of arrhythmic events. [source]


    Heart Rate Variability Fraction,A New Reportable Measure of 24-Hour R-R Interval Variation

    ANNALS OF NONINVASIVE ELECTROCARDIOLOGY, Issue 1 2005
    Maciej Sosnowski M.D.
    Background: The scatterplot of R-R intervals has several unique features. Its numerical evaluation may produce a new useful index of global heart rate variability (HRV) from Holter recordings. Methods: Two-hundred and ten middle-aged healthy subjects were enrolled in this study. The study was repeated the next day in 165 subjects. Each subject had a 24-hour ECG recording taken. Preprocessed data were transferred into a personal computer and the standard HRV time-domain indices: standard deviation of total normal R-R intervals (SDNN), standard deviation of averaged means of normal R-R intervals over 5-minute periods (SDANN), triangular index (TI), and pNN50 were determined. The scatterplot area (0.2,1.8 second) was divided into 256 boxes, each of 0.1-second interval, and the number of paired R-R intervals was counted. The heart rate variability fraction (HRVF) was calculated as the two highest counts divided by the number of total beats differing from the consecutive beat by <50 ms. The HRVF was obtained by subtracting this fraction from 1, and converting the result to a percentage. Results: The normal value of the HRVF was 52.7 ± 8.6%. The 2,98% range calculated from the normal probability plot was 35.1,70.3%. The HRVF varied significantly with gender (female 48.7 ± 8.4% vs male 53.6 ± 8.6%, P = 0.002). The HRVF correlated with RRI (r = 0.525) and showed a similar or better relationship with SDNN (0.851), SDANN (0.653), and TI (0.845) than did the standard HRV measures with each other. Bland-Altman plot showed a good day-by-day reproducibility of the HRVF, with the intraclass correlation coefficient of 0.839 and a low relative standard error difference (1.8%). Conclusion: We introduced a new index of HRV, which is easy for computation, robust, reproducible, easy to understand, and may overcome the limitations that belong to the standard HRV measures. This index, named HRV fraction, by combining magnitude, distribution, and heart-rate influences, might become a clinically useful index of global HRV. [source]


    Beat-to-Beat QT Dynamics in Healthy Subjects

    ANNALS OF NONINVASIVE ELECTROCARDIOLOGY, Issue 1 2004
    Berit T. Jensen M.D.
    Background: Measures of QT dynamics express repolarization abnormalities that carry prognostic information, but the reproducibility of beat-to-beat QT dynamics has never been established. The QT interval is prolonged at night, but how the circadian rhythm and heart rate influence the dynamic QT measurements is still unsettled. The aims of the present study were: (1) to describe the reproducibility of beat-to-beat QT dynamics with respect to intrasubject, between-subject, and between-observer variability and (2) to describe the normal range, circadian variation, and heart rate dependence of QT dynamics. Methods: Ambulatory Holter recordings were performed three times on 20 healthy volunteers and were analyzed by two experienced cardiologists. Slope and intercept of the QT/RR regression, the variability of QT and R-R intervals expressed as the standard deviation, and the relation between QT and RR variability expressed as a variability ratio were measured among other QT dynamics. Results: The reproducibility of all QT dynamics was good. All QT dynamics showed circadian variation when calculated on an hourly basis. The day/night variation in slope could be explained by the differences in heart rate, whereas the day/night variation in intercept was heart rate independent. Conclusion: The present study shows that reliable automatic QT measurements could be performed, encouraging further evaluation of the clinical value of QT dynamics in risk stratification of cardiac patients. [source]