Home About us Contact | |||
Ambulatory Electrocardiograms (ambulatory + electrocardiogram)
Selected AbstractsEFFECT OF BENAZEPRIL ON HEART RATE TURBULENCE IN PATIENTS WITH DILATED CARDIOMYOPATHYCLINICAL AND EXPERIMENTAL PHARMACOLOGY AND PHYSIOLOGY, Issue 7 2007Jiang-Hua Zhong SUMMARY 1Heart rate (HR) turbulence describes short-term sinus rhythmic fluctuation after a single premature ventricular beat. Turbulence onset (TO) and turbulence slope (TS) are two essential parameters in HR turbulence. Turbulence onset and TS have been used to evaluate cardiac autonomic nerve function. 2In the present study, we measured the HR turbulence in dilated cardiomyopathy (DCM) and determined the possible role of benazepril, an angiotensin-converting enzyme inhibitor (ACEI), on these parameters. There were three groups: control, DCM and DCM treated with benazepril. The control group consisted of normal subjects with PVB, but no structural heart disease. Ambulatory electrocardiogram, blood pressure and echocardiography were analysed. 3There was an increase in TO and a decrease in TS in DCM patients. Benazepril treatment (10 mg/day, p.o.) reduced those changes. There were no significant differences in blood pressure and left ventricular ejection fraction (LVEF) between DCM patients and DCM patients treated with benazepril. 4Linear regression analysis showed that TO was negatively correlated with LVEF, whereas TS was positively correlated with LVEF, in the DCM group. After benazepril treatment, the correlations between TO and TS and LVEF disappeared. 5It is concluded that the TO and TS of HR turbulence are altered in patients with DCM. These alterations indicate a dysfunction of the autonomic control of cardiac electrophysiology in DCM patients. Although TO and TS are correlated with LVEF in DCM patients, the effect of benazepril in improving HR turbulence parameters is not a result of its action on heart function, which suggests a new beneficial effect of ACEI in the treatment of DCM patients. [source] Effect of Right Ventricular Apex Pacing on the Tei Index and Brain Natriuretic Peptide in Patients with a Dual-Chamber PacemakerPACING AND CLINICAL ELECTROPHYSIOLOGY, Issue 9 2006HITOSHI ICHIKI Background: Asynchronous electrical activation induced by right ventricular apex (RVA) pacing can cause various abnormalities in left ventricular (LV) function, particularly in the context of severe LV dysfunction or structural heart disease. However, the effect of RVA pacing in patients with normal LV and right ventricular (RV) function has not been fully elucidated. The aim of this study was to characterize the effects of RVA pacing on LV and RV function by assessing isovolumic contraction time and isovolumic relaxation time divided by ejection time (Tei index) and by assessing changes in plasma brain natriuretic peptide (BNP). Methods: Doppler echocardiographic study and BNP measurements were performed at follow-up (mean intervals from pacemaker implantation, 44 ± 75 months) in 76 patients with dual chamber pacemakers (sick sinus syndrome, n = 30; atrioventricular block, n = 46) without structural heart disease. Patients were classified based on frequency of RVA pacing, as determined by 24-hour ambulatory electrocardiogram (ECG) that was recorded just before echocardiographic study: pacing group, n = 46 patients with RVA pacing ,50% of the time, percentage of ventricular paced 100 ± 2%; sensing group, n = 30, patients with RVA pacing <50% of the time, percentage of ventricular paced 3 ± 6%. Results: There was no significant difference in mean heart rate derived from 24-hour ambulatory ECG recordings when comparing the two groups (66 ± 11 bpm vs 69 ± 8 bpm). LV Tei index was significantly higher in pacing group than in sensing group (0.67 ± 0.17 vs 0.45 ± 0.09, P < 0.0001), and the RV Tei index was significantly higher in pacing group than in sensing group (0.34 ± 0.19 vs 0.25 ± 0.09, P = 0.011). Furthermore, BNP levels were significantly higher in pacing group than in sensing group (40 ± 47 pg/mL vs 18 ± 11 pg/mL, P = 0.017). With the exception of LV diastolic dimension (49 ± 5 mm vs 45 ± 5 mm, P = 0.012), there were no significant differences in other echocardiographic parameters, including left atrium (LA) diameter (35 ± 8 mm vs 34 ±5 mm), LA volume (51 ± 27 cm3 vs 40 ± 21 cm3), LV systolic dimension (30 ± 6 mm vs 29 ± 7 mm), or ejection fraction (66 ± 9% vs 63 ± 11%), when comparing the two groups. Conclusions: These findings suggest that the increase of LV and RV Tei index, LVDd, and BNP are highly correlated with the frequency of the RVA pacing in patients with dual chamber pacemakers. [source] Temporal Variability of Ventricular Arrhythmias in Boxer Dogs with Arrhythmogenic Right Ventricular CardiomyopathyJOURNAL OF VETERINARY INTERNAL MEDICINE, Issue 5 2009B.A. Scansen Background: Arrhythmogenic right ventricular cardiomyopathy (ARVC) is prevalent in the Boxer. There is little information on the temporal variability of ventricular arrhythmias within affected dogs. Objective: To evaluate ambulatory electrocardiograms (AECG) from Boxers with ARVC for hourly variation in premature ventricular complexes (PVC) and heart rate (HR). Animals: One hundred and sixty-two Boxer dogs with ARVC. Methods: Retrospective, observational study of 1,181 AECGs collected from Boxer dogs at The Ohio State University from 1997 to 2004 was evaluated. The proportion of depolarizations that were PVCs was compared across each hour of the day, during six 4-hour periods of day, to the time after AECG application, and to the maximum and minimum HR. Results: A lower proportion of PVCs was noted during early morning (midnight to 0400 hours) as compared with the morning (0800,1200 hours) and late (1600,2000 hours) afternoon (P= .012). There was no increase in PVC proportion in the 1st hour after AECG application as compared with all other hours of the day (P= .06). There was poor correlation between maximum (,= 0.19) and minimum (,= 0.12) HR and PVC proportion. Conclusions and Clinical Importance: The likelihood of PVC occurrence in Boxer dogs with ARVC was relatively constant throughout the day, although slightly greater during the hours of 0800,1200 and 1600,2000. A biologically important correlation with HR was not apparent. The role of autonomic activity in the modulation of electrical instability in the Boxer with ARVC requires further study. [source] Effect of Noise on T-Wave Alternans Measurement in Ambulatory ECGs Using Modified Moving Average versus Spectral MethodPACING AND CLINICAL ELECTROPHYSIOLOGY, Issue 5 2009RAJA J. SELVARAJ M.D. Background: The modified moving average (MMA) and spectral method (SM) are commonly used to measure T-wave alternans (TWA), but their accuracy has not been compared in ambulatory electrocardiograms (ECGs) where TWA signal-to-noise ratio is low. Our objective was to compare the effect of noise and signal nonstationarity on the accuracy of TWA measurement using MMA versus SM when applied to synthetic and ambulatory ECGs. Methods: Periodic and nonperiodic noise were added to noiseless synthetic ECGs. Simulated TWA (0,20 ,V) was added to synthetic ECGs and ambulatory ECG recordings. TWA was measured using SM and MMA, and the measurement error relative to added TWA was compared. An MMA ratio was used to discriminate TWA signal from noise. Signal nonstationarity was simulated by changing heart rate, TWA magnitude, and TWA phase. Results: With no added TWA, MMA falsely measured TWA in synthetic and ambulatory ECGs, while false measurement was not seen with SM. An MMA ratio > 1.2 eliminated false TWA detection. In the presence of low TWA magnitude (<10 ,V), TWA was overestimated by MMA and underestimated by SM in proportion to the noise level. In synthetic ECGs with periodic noise and 10-,V added TWA, MMA was less accurate than SM. The effects of simulated signal nonstationarity on the TWA magnitude measured with MMA versus SM were similar using a 64-beat analysis window. Conclusions: In the presence of noise, MMA falsely detects or overestimates simulated TWA in ambulatory ECG recordings. In this setting, the proposed MMA ratio improves the specificity of MMA. [source] Analysis of the Corrected QT Before the Onset of Nonsustained Ventricular Tachycardia in Patients with Hypertrophic CardiomyopathyPACING AND CLINICAL ELECTROPHYSIOLOGY, Issue 1p2 2003BARANOWSKI BARANOWSKI, R., et al.: Analysis of the Corrected QT Before the Onset of Nonsustained Ventricular Tachycardia in Patients with Hypertrophic Cardiomyopathy. This study examined ventricular repolarization before the onset of 37 episodes of nonsustained ventricular tachycardia (NSVT) in 26 untreated patients with hypertrophic cardiomyopathy (HCM). Fourteen episodes were recorded in patients with a history of cardiac arrest or patients who died suddenly during follow-up. The QT interval was measured beat-by-beat on 24-hour ambulatory electrocardiograms. Mean 24-hour, hourly QTc and QTc of the last 10 beats prior to NSVT, consisted of 4,50 cycles (mean9 ± 10), at the fastest rates of 100,175 beats/min (mean 122 ± 22) were analyzed. NSVT was more prevalent during nighttime (23 episodes), than during daytime (14 episodes,P < 0.05). No significant differences were observed between mean 24-hour, mean hourly QTc during the hour with NSVT, and QTc of the last 10 cycles prior to onset of NSVT. QTc was significantly longer in patients with a history of sudden cardiac death (SCD) or who died suddenly during follow-up than in survivors. The 24-hour QT variability was higher in nonsurvivors than in survivors ( -39 ± 6vs33 ± 6 ms, P = 0.03). Episodes of NSVT in untreated patients with hypertrophic cardiomyopathy were more frequent during the nighttime. The 24-hour QT variability was higher in nonsurvivors than in survivors. (PACE 2003; 26[Pt. II]:387,389) [source] |