Hand Dermatitis (hand + dermatitis)

Distribution by Scientific Domains


Selected Abstracts


Hand dermatitis and lymphoedema

BRITISH JOURNAL OF DERMATOLOGY, Issue 1 2009
V.J. Pearce
Summary Hand dermatitis is common, with lymphoedema of the hand and forearm a rare complication. The mechanism of lymphoedema in such cases is poorly understood, hence management can be challenging. To investigate the underlying mechanism of lymphoedema associated with hand dermatitis and outline recommendations for management, we identified all patients with lymphoedema associated with hand dermatitis referred to our lymphoedema service, a tertiary referral centre. Treatment outcome was assessed by telephone interview and through correspondence with primary physicians and therapists. In total, nine patients, six with bilateral and three with unilateral lymphoedema associated with hand dermatitis, attended our service over a 4-year period. Most had long-standing bilateral pompholyx eczema. Three patients reported no signs of infection prior to the onset of swelling. All patients had recurrent episodes of infection after the onset of swelling. Lymphoscintigraphy, when used, revealed a failure of small initial lymphatics of the hand to absorb and drain lymph to regional nodes. Prophylactic antibiotics together with aggressive management of the dermatitis, often with systemic therapy, were required to reduce swelling. Possible mechanisms for lymphoedema associated with hand dermatitis include obliterative lymphangitis from infection, an inflammatory effect of the dermatitis on local lymphatics or a constitutive weakness of lymph drainage exposed to chronic inflammation, or any combination of the three. Treatment is only successful once both infection and inflammation from the dermatitis are controlled. [source]


Novel treatment of chronic severe hand dermatitis with bexarotene gel

BRITISH JOURNAL OF DERMATOLOGY, Issue 3 2004
J.M. Hanifin
Summary Background Hand dermatitis is an eczematous inflammation of the hands that is related to occupation or to routine activities. It often becomes chronic, and in some patients may become severe and disabling. Topical corticosteroids are effective treatment, particularly for milder forms, but they often lose effectiveness with time and can produce skin atrophy. Objectives To evaluate bexarotene gel topical therapy for safety, tolerability and efficacy in patients with chronic hand dermatitis. Methods A phase I,II open-label randomized clinical study of bexarotene gel, alone and in combination with a low- and a mid-potency steroid, was conducted in 55 patients with chronic severe hand dermatitis at two academic clinics. Results Patients using bexarotene gel monotherapy reached a 79% response rate for ,,50% clinical improvement and a 39% response rate for ,,90% clearance of hands. Adverse events possibly related to treatment in all patients were stinging or burning (15%), flare of dermatitis (16%) and irritation (29%). Thirteen patients (24%) withdrew early, including two for related adverse events and five for inadequate response. Conclusions Bexarotene gel appears to be safe, tolerated by most patients, with useful therapeutic activity in chronic severe hand dermatitis. [source]


A spot test for detection of cobalt release , early experience and findings

CONTACT DERMATITIS, Issue 2 2010
Jacob P. Thyssen
Background: It is often difficult to establish clinical relevance of metal exposure in cobalt-allergic patients. Dermatologists and patients may incorrectly assume that many metallic items release cobalt at levels that may cause cobalt dermatitis. Cobalt-allergic patients may be unaware that they are exposed to cobalt from handling work items, causing hand dermatitis. Objectives: To present early findings with a newly developed cobalt spot test. Methods and Results: A cobalt spot test based on disodium-1-nitroso-2-naphthol-3,6-disulfonate was able to identify cobalt release at 8.3 ppm. The test may also be used as a gel test if combined with an agar preparation. We found no false-positive reactions when testing metals and alloys known not to contain cobalt. However, one cobalt-containing alloy, which elicited cobalt dermatitis in cobalt-allergic patients, was negative upon cobalt gel testing. Conclusions: The cobalt test detects amounts of cobalt release that approximate the elicitation concentration seen in cobalt-allergic patients. It may serve as a useful tool in dermatology offices and workplaces. [source]


Non-invasive bioengineering methods in an intervention study in 1020 male metal workers: results and implications for occupational dermatology

CONTACT DERMATITIS, Issue 5 2010
Birgitta Kütting
Background: Measurements of transepidermal water loss (TEWL) as an indicator of skin barrier function and colorimetry for quantifying erythema have been recommended for monitoring persons at risk of occupational hand dermatitis. Objective: This study examines the practicability and usefulness of biophysical measurements at the workplace. Patients/Material/Methods: A sample of 1020 male metal workers was enrolled; 800 participants were followed up for 1 year. TEWL results and colorimetry (a* value), respectively, were used as effectiveness outcomes, comparing the findings in the four study arms (skin care, skin protection, both combined, and control group). Results: At 1 year follow-up, the TEWL was slightly but significantly lower in the group of participants randomized for application of barrier cream alone, indicating a protective effect. However, addressing both the individual absolute change of a* value and the differences of TEWL (delta-TEWL) of the dominant hand over the study period, no significant difference was found between the four groups. Conclusions: Dermatological examinations at the workplace cannot be replaced by bioengineering techniques. The supplementary benefit is apparently low, possibly because of difficulties in achieving standardized measurement conditions and other technical reasons. [source]


Evaluation of 2 self-administered questionnaires to ascertain dermatitis among metal workers and its relation with exposure to metalworking fluids

CONTACT DERMATITIS, Issue 6 2007
Berna Van Wendel de Joode
We performed an exploratory study to evaluate 2 self-administered questionnaires assessing hand dermatitis and investigate a possible exposure,response relationship between dermal exposure to semi-synthetic metalworking fluids (SMWF) and dermatitis. In a cross-sectional survey on dermatitis, a symptom-based questionnaire and a picture-based skin screening list were applied in 80 SMWF-exposed workers and 67 referents. To evaluate the accuracy of the questionnaires, 47 subjects were examined by a dermatologist. Dermal exposure levels to SMWF were assessed on hands, forearms, and face with a observational method that was validated using a fluorescent tracer method. The symptom-based questionnaire had a relatively high sensitivity (0.86) but moderate specificity (0.64), and the skin screening list had a low sensitivity (0.36) and a relatively high specificity (0.84). The skin screening list seemed to represent the more severe cases of dermatitis and showed a significant relation with exposure for dermatitis on hands, forearms, or face. In epidemiological surveys where workers are not seen by a dermatologist, the skin screening list seems to be more appropriate to detect cases of dermatitis, as its higher specificity results in less false positives. Alternatively, it would be preferable applying the symptom-based questionnaire; workers with symptoms should be seen by a dermatologist to identify false positives. [source]


Contact allergy to textile dyes in southern Sweden

CONTACT DERMATITIS, Issue 6 2006
K. Ryberg
Contact allergy to disperse dyes in textiles is documented in prevalence studies from southern Europe. To evaluate the prevalence of allergic patch test reactions to different textile dyes in southern Sweden, and to look at the sites of dermatitis in individuals hypersensitive to textile dyes, we retrospectively investigated 3325 consecutively patch-tested patients. They had all been patch tested with the standard test series supplemented with a textile dye mix (TDM) consisting of 8 disperse dyes, i.e. Disperse (D) Blue 35, 106 and 124, D Yellow 3, D Orange 1 and 3 and D Red 1 and 17. All but 3 of the TDM-positive patients were additionally tested with the separate dyes included in the mix. The frequency of contact allergy to TDM was 1.5%, which is comparable with studies from southern Europe. The most common dye allergen was D Orange 1. The high prevalence of allergic reactions to D Orange 1 was unexpected, whereas test reactions to D Blue 106 and 124 were lower than expected from other studies. Compared to all tested patients, the TDM-positive patients more often had dermatitis on their arms, face, neck and axillary folds, and women also had a higher frequency of hand dermatitis. [source]


FC03.1 Experience from joint occupational health/dermatology clinics

CONTACT DERMATITIS, Issue 3 2004
Yat Wing Wong
Background:, A monthly consultant led occupational health/dermatology clinic was started in 1999 providing rapid access to staff with suspected occupational skin disease including natural rubber latex (NRL) allergy and teaching for the occupational health staff. Objectives:, To evaluate the characteristics and outcome of staff attending this clinic and to assess patient satisfaction. Methods:, A retrospective case note survey was performed from staff attending the clinic from 1999 to 2002. A questionnaire was sent to them >3 months following consultation. Results:, A total of 116 patients were identified (12 male, 104 female), and 85 (73%) were nurses. 77 (66%) patients were referred with hand eczema (HE). Of the 45 patients referred with adverse reactions or exacerbation of hand dermatitis following the use of latex gloves, only 4 had positive prick tests and were considered to have NRL allergy. Patients with significant HE or occupational exacerbation of HE were referred for patch testing (n = 36). Of the remainder, most could be discharged after a single visit. 49/95 (52%) questionnaires were returned, 34/45 (76%) patients found the consultation useful. As a separate study, the data recorded within the patch test clinic looking at health care workers (HCW) referred both from this clinic and from other sources was analysed. This showed relevant positive patch tests in 16/49 (33%) patients. In 55/99 (56%), an occupational cause was likely. Conclusion:, Occupational skin disease in HCW is common, attendance at the clinic was beneficial and a single visit was sufficient in most cases. [source]


P03 Type-I and -IV hypersensitivity to platinum salts

CONTACT DERMATITIS, Issue 3 2004
Willeke Kamphof
A 28-year-old female analytical chemist visited our patch test clinic with initially complaints of severe hand dermatitis. Later on she developed rhinitis, bronchial asthma and tightness of the chest. The complaints seemed work related: her condition improved during holidays and on sick leaves. She worked in a laboratory with several platinum salts and used different kinds of gloves (latex, nitril, etc.). Methods:, Patch tests were performed with the European Standard series and prick tests with common inhalant allergens. Patch-, prick- and open patch tests were carried out with various aqueous dilutions of platinum chloride (PtCl2). Results:, Patch tests with 0.01,2% PtCl2 were positive on day 2, 3 and 6, and at 0.001% a follicular reaction was found. The prick-test was already positive at the lowest concentration tested (0.001%). The open patch test, carried out retro-auricular, showed a positive reaction at 1 and 2% PtCl2 after 20 min. Controls in healthy volunteers (n = 5) were all negative. Discussion:, It is well known that platinum salts can cause type-I hypersensitivity reactions like allergic rhinitis, conjunctivitis, bronchial asthma and urticaria, also referred to as platinosis. Contact dermatitis to platinum salts, however, is very rare. In our patch test clinic, 78 patients were tested between 1987 and 2001 with PtCl2 2%. Only 2 women showed a positive patch test for PtCl2. The patient presented here, stopped working with platinum salts and recovered from all complaints. We interpret our case as occupational type-I and type-IV hypersensitivity to platinum salts with mucosal and dermal manifestations. [source]


Contact dermatitis in Korean dental technicians

CONTACT DERMATITIS, Issue 1 2001
Jun Young Lee
The high risk of occupational contact dermatitis in dental personnel are well accepted throughout the world. There are few reports concerning occupational skin disease in dental personnel in Korea. The purposes of this study were to investigate the frequency, characteristics and causative factors of contact dermatitis in Korean dental technicians. Recording of personal history, physical examination and patch tests with the Korean standard series and dental screening series were performed in 49 dental technicians. Most of the subjects were exposed to a variety of compounds, including acrylics, metals, plaster, alginate, etc. 22 (44.9%) subjects had contact dermatitis, present or past, and the site involved was the hand in all 22. The most common clinical feature of hand dermatitis was itching (77.3%); scaling, fissuring and erythema were other common clinical features. Metals, including potassium dichromate (24.5%), nickel sulfate (18.4%), mercury ammonium chloride (16.3%), cobalt chloride (12.2%) and palladium chloride (10.2%), showed high positive rates in patch test results of 49 dental technicians. 7 positive reactions to the various acrylics were found in 3 subjects. In our study, the frequency and clinical features of the contact dermatitis showed a similarity to other reports, though the patch test results were somewhat different; a higher patch-positive reaction to metals and a relatively lower patch-positive reaction to acrylics than the patch test results reported in Europe. [source]


The efficacy of ,0.05% Clobetasol + 2.5% zinc sulphate' cream vs. ,0.05% Clobetasol alone' cream in the treatment of the chronic hand eczema: a double-blind study

JOURNAL OF THE EUROPEAN ACADEMY OF DERMATOLOGY & VENEREOLOGY, Issue 5 2008
G Faghihi
Abstract Background, Many therapeutic modalities have been suggested for treatment of the chronic hand eczema. Despite good immediate efficacy of some of these treatments, there is high recurrence of the dermatitis following cessation of the treatment. Aim, Regarding the beneficial effects of the zinc sulfate on the skin, we designed a double blind study to evaluate the efficacy of the ,0.05% Clobetasol + 2.5% zinc sulphate' cream versus ,0.05% Clobetasol alone' cream in the treatment of the chronic hand eczema. Subjects and Methods, This study was a double-blind, right to left, prospective, clinical trial. In total, 47 patients with chronic hand eczema admitted to dermatology center of Isfahan University of Medical Sciences were selected and their right hand or left hand were selected at random to be treated with either the ,0.05% Clobetasol + 2.5% zinc sulphate' cream or ,0.05% Clobetasol alone' cream twice daily for 2 weeks. All of the patients were treated for 2 weeks and were followed up at weeks 2, 4, 6 and 8 after starting the treatment. For determining the severity of chronic hand eczema, we assessed and scored 4 different characteristics of the lesions including redness; scaling; lichenification and pruritus. The data were analyzed using SPSS program (release 13) and statistical tests including Mann-Whitney test. Results, Overall, 47 patients (94 samples) were evaluated. All of these patients had similar and symmetrical lesions on their right and left hands. Out of them, 35 patients were females and 12 patients were male. In all of the evaluated characterisitics, the ,0.05% Clobetasol + 2.5% zinc sulphate' cream was more effective than ,0.05% Clobetasol alone' cream (P < 0.05). The recurrence rate of eczema was significantly lower in the group treated with this combination treatment (P < 0.05). Conclusion, With regard to the encouraging results of the combination treatment with Clobetasol + zinc sulphate, we suggest that in a more extensive clinical trial, the efficacy of this treatment against chronic hand dermatitis be evaluated. In addition, evaluation of this combination therapy against other inflammatory dermatosis seems to be logical. [source]


Acanthosis nigricans: A new cutaneous sign in severe atopic dermatitis and Down syndrome

JOURNAL OF THE EUROPEAN ACADEMY OF DERMATOLOGY & VENEREOLOGY, Issue 4 2001
MA Muńoz-Pérez
Abstract Acanthosis nigricans (AN) occurs associated with many different systemic diseases, such as endocrine disorders and internal malignant neoplasms. To our knowledge, the association of AN with severe atopic dermatitis (AD) or Down syndrome has not been described before. This 82-month retrospective study included 1038 patients: AN was present in 4.9% of atopic patients and 50.9% of subjects with Down syndrome. AN was more frequent in patients with severe AD and in 100% of cases of hand dermatitis and juvenile plantar dermatosis, located on the interphalangeal and metacarpophalangeal joints, whereas in Down syndrome other flexures were also affected. The pathogenesis of AN in AD is unknown, but in Down syndrome it seems to be related to obesity. Possible insulin resistance underlyng the pathogenesis of AN in these patients is still unknown. [source]


Prospective study of clinical symptoms and skin test reactions in medical students exposed to formaldehyde gas

THE JOURNAL OF DERMATOLOGY, Issue 5 2007
Sachiko TAKAHASHI
ABSTRACT Previous investigators have reported the occurrence of both allergic and non-allergic systemic complications due to exposure to formaldehyde gas. However, little is known about the pathogenic link between formaldehyde-induced clinical symptoms and patch test results, or about the long-term effects of formaldehyde exposure. In the present study, a questionnaire was administered to 143 medical students, and 60 of them were tested by patch test for formaldehyde at the beginning and end of a human anatomy laboratory course. Another group of 76 students who had finished the course 2,4 years previously were administered another questionnaire, and the patch test was carried out on 58 of them. The frequencies of skin irritation, eye soreness, lacrimation, eye fatigue, rhinorrhea, throat irritation, general fatigue and mood swings increased after repeated exposure. Two (3.3%) of 60 students became positive to 1% formaldehyde at the end of the anatomy course (one male with allergic hand dermatitis due to direct contact with formaldehyde, and one female with an atopic background with unbearable physical symptoms) while the remaining 58 showed a negative reaction throughout the study period. The vast majority of students complained of various non-allergic, physical symptoms, and recovered from such symptoms without subsequent complications. No progression to multiple chemical sensitivity was found. Students with an episode of atopic dermatitis and allergic rhinitis were susceptible to formaldehyde exposure, and developed mucocutaneous symptoms, probably due to the impaired barrier function and remodeling of the skin and mucosa. [source]


Occupational allergic contact dermatitis to cobalt octoate included as an accelerator in a polyester resin

AUSTRALASIAN JOURNAL OF DERMATOLOGY, Issue 2 2006
Namrata S Anavekar
SUMMARY A 46-year-old woman, who worked as a laminator of spa baths, presented with hand dermatitis, which was suspected to be related to her occupation. Patch testing revealed strong reactions to both cobalt chloride and a polyester resin that the patient had been using at her workplace. She also reacted to latex and had been wearing cotton gloves underneath rubber gloves at work. It was later discovered that cobalt octoate (synonym: cobalt-2-ethylhexanoate), a compound not listed on the manufacturer's material safety data sheet, was included as an accelerator in the polyester resin. She was then tested to cobalt octoate, which was also strongly positive. Her successful treatment included protection of her hands at work with cotton lined PVC gloves. This case highlights the role of cobalt salts as sensitizers and their presence as accelerators used in polyester resins, and the importance of recognizing concomitant latex allergy that may complicate occupational dermatitis. It also illustrates the difficulties in relying on material safety data sheets to identify all possible allergens. [source]


Hand dermatitis and lymphoedema

BRITISH JOURNAL OF DERMATOLOGY, Issue 1 2009
V.J. Pearce
Summary Hand dermatitis is common, with lymphoedema of the hand and forearm a rare complication. The mechanism of lymphoedema in such cases is poorly understood, hence management can be challenging. To investigate the underlying mechanism of lymphoedema associated with hand dermatitis and outline recommendations for management, we identified all patients with lymphoedema associated with hand dermatitis referred to our lymphoedema service, a tertiary referral centre. Treatment outcome was assessed by telephone interview and through correspondence with primary physicians and therapists. In total, nine patients, six with bilateral and three with unilateral lymphoedema associated with hand dermatitis, attended our service over a 4-year period. Most had long-standing bilateral pompholyx eczema. Three patients reported no signs of infection prior to the onset of swelling. All patients had recurrent episodes of infection after the onset of swelling. Lymphoscintigraphy, when used, revealed a failure of small initial lymphatics of the hand to absorb and drain lymph to regional nodes. Prophylactic antibiotics together with aggressive management of the dermatitis, often with systemic therapy, were required to reduce swelling. Possible mechanisms for lymphoedema associated with hand dermatitis include obliterative lymphangitis from infection, an inflammatory effect of the dermatitis on local lymphatics or a constitutive weakness of lymph drainage exposed to chronic inflammation, or any combination of the three. Treatment is only successful once both infection and inflammation from the dermatitis are controlled. [source]


Novel treatment of chronic severe hand dermatitis with bexarotene gel

BRITISH JOURNAL OF DERMATOLOGY, Issue 3 2004
J.M. Hanifin
Summary Background Hand dermatitis is an eczematous inflammation of the hands that is related to occupation or to routine activities. It often becomes chronic, and in some patients may become severe and disabling. Topical corticosteroids are effective treatment, particularly for milder forms, but they often lose effectiveness with time and can produce skin atrophy. Objectives To evaluate bexarotene gel topical therapy for safety, tolerability and efficacy in patients with chronic hand dermatitis. Methods A phase I,II open-label randomized clinical study of bexarotene gel, alone and in combination with a low- and a mid-potency steroid, was conducted in 55 patients with chronic severe hand dermatitis at two academic clinics. Results Patients using bexarotene gel monotherapy reached a 79% response rate for ,,50% clinical improvement and a 39% response rate for ,,90% clearance of hands. Adverse events possibly related to treatment in all patients were stinging or burning (15%), flare of dermatitis (16%) and irritation (29%). Thirteen patients (24%) withdrew early, including two for related adverse events and five for inadequate response. Conclusions Bexarotene gel appears to be safe, tolerated by most patients, with useful therapeutic activity in chronic severe hand dermatitis. [source]


Which children should we patch test?

CLINICAL & EXPERIMENTAL DERMATOLOGY, Issue 1 2007
P. E. Beattie
Summary Background., Allergic contact dermatitis (ACD) in childhood was considered rare until recently. However, reports are increasing, which may reflect an increased incidence and/or more frequent patch testing of children. It is also likely that allergen exposure in children has changed with time. Aims., To determine the most common contact allergens and the rate of positive patch-test reactions among children with suspected contact allergy. Methods., We carried out a retrospective case study of 114 children (66 girls and 48 boys) aged from 3 to 15 years (median 11.5) patch tested over a 3-year period. Indications for patch testing included uncontrolled or deteriorating atopic dermatitis, localized dermatitis or a history of reacting to a specific allergen. Results., Of 110 children for whom we had notes, 83 (75%) had a history of atopy. Positive reactions that were of current, past or possible relevance were seen in 61 children (54%); in 58 (52%) of 111 tested with the standard series (SS) and in 6 (10%) of 60 tested with the medicament series. None of the children patch tested to the corticosteroid (n = 47), shoe (n = 15), fragrance (n = 12), cosmetic (n = 10) or rubber (n = 5) series had a positive reaction. However, 11 (10%) reacted to rubber allergens within the SS and one of five to their own shoes. The lowest rate of relevant positive reactions was among those with deteriorating atopic dermatitis (22%) and facial (33%) or perioral dermatitis (40%), and the highest rate amongst those with eyelid (86%) or hand (71%) dermatitis. Nickel was the most common allergen (20%) in line with previous reports (82% female), followed by rubber chemicals (10%), fragrance (7.2%), cobalt (5.4%) and lanolin (wool alcohol) (4.5%). Conclusions., The reported incidence of ACD among children, in particular nickel and rubber allergy, appears to be increasing, which may relate to changing fashions and hobbies. Contact allergy should be considered in all children with dermatitis, particularly with eyelid or hand dermatitis, and patch testing carried out more frequently. [source]