Glove perforations during open surgery for gynaecological malignancies

BJOG : AN INTERNATIONAL JOURNAL OF OBSTETRICS & GYNAECOLOGY, Issue 8 2008
AP Manjunath
Objective, To audit glove perforations at laparotomies for gynaecological cancers. Setting, Gynaecological oncology unit, cancer centre, London. Design, Prospective audit. Sample, Twenty-nine laparotomies for gynaecological cancers over 3 months. Methods, Gloves used during laparotomies for gynaecological cancer were tested for perforations by the air inflation and water immersion technique. Parameters recorded were: type of procedure, localisation of perforation, type of gloves, seniority of surgeon, operation time and awareness of perforations. Main outcome measure, Glove perforation rate. Results, Perforations were found in gloves from 27/29 (93%) laparotomies. The perforation rate was 61/462 (13%) per glove. The perforation rate was three times higher when the duration of surgery was more than 5 hours. The perforation rate was 63% for primary surgeons, 54.5% for first assistant, 4.7% for second assistant and 40.5% for scrub nurses. Clinical fellows were at highest risk of injury (94%). Two-thirds of perforations were on the index finger or thumb. The glove on the nondominant hand had perforations in 54% of cases. In 50% of cases, the participants were not aware of the perforations. There were less inner glove perforations in double gloves compared with single gloves (5/139 versus 26/154; P = 0.0004, OR = 5.4, 95% CI 1.9,16.7). The indicator glove system failed to identify holes in 44% of cases. Conclusions, Glove perforations were found in most (93%) laparotomies for gynaecological malignancies. They are most common among clinical fellows, are often unnoticed and often not detected by the indicator glove system. [source]


Latex-induced occupational asthma: time trend in incidence and relationship with hospital glove policies

ALLERGY, Issue 3 2009
O. Vandenplas
Background:, Natural rubber latex (NRL) has become as a major cause of occupational asthma (OA) in workers using NRL gloves. Few population-based studies have assessed the impact of changes in the patterns of glove usage on the incidence of NRL-induced OA. Objective:, To characterize the time trends in incident cases of NRL-induced OA in Belgium and examine whether incidence rates were related to the types of gloves used in hospitals. Methods:, Incident cases of NRL-induced OA were identified through a retrospective review of all claims submitted to the Workers' Compensation Board up to December 2004. Based on the results of diagnostic procedures, the diagnosis of NRL-induced OA was categorized as definite, probable, unlikely, or indeterminate. The patterns of glove usage were characterized through a questionnaire survey of Belgian hospitals. Results:, A total of 298 claims for NRL-induced OA were identified, including 127 subjects with definite OA and 68 with probable OA. Categorized by the year of asthma onset, the incident cases of definite and probable NRL-induced OA markedly decreased from 1999 onwards. The use of powdered NRL gloves fell from 80.9% in 1989 to 17.9% in 2004. Powdered NRL gloves were predominantly substituted with NRL-free gloves, especially in the case of non-sterile procedures. Conclusion:, These national compensation-based data confirm that a persistent decline in the incidence of NRL-induced OA has occurred since late 1990s. This downward trend has temporally been associated with a decreasing usage of powdered NRL, further supporting a beneficial role of changes in glove policies. [source]


A study of natural rubber latex allergens in gloves used by healthcare workers in Singapore

BRITISH JOURNAL OF DERMATOLOGY, Issue 5 2005
D. Koh
Summary Background, Allergy to natural rubber latex (NRL) proteins is a well-recognized health problem among subjects using protective gloves and products made of NRL. There is currently no information on NRL allergen levels in gloves used in Singapore. Objectives, This study aims to quantify the amount of specific allergens (Hev b 1, Hev b 3, Hev b 5 and Hev b 6.02) found in rubber gloves used in Singapore. It also aims to determine if these levels are above thresholds that may cause NRL allergy. It also compares the levels of these specific allergens in gloves used for different purposes, namely gloves used for examination purposes or for surgical procedures. Methods, Forty-nine rubber gloves were obtained from major hospitals and healthcare departments in Singapore and were analysed for their NRL allergen levels. FITkitTM, based on the enzyme immunometric assay technique, was used to determine the specific allergen levels of Hev b 1, Hev b 3, Hev b 5 and Hev b 6.02 in the gloves. Results, Examination gloves had higher NRL allergen content compared with surgical gloves, and powdered gloves had higher allergen content compared with nonpowdered gloves. Among the various allergens, Hev b 5 and Hev b 6.02 were present in larger quantities than Hev b 1 and Hev b 3. Only two of 19 (11%) surgical gloves had the sum of the four allergens (Hev b 1, Hev b 3, Hev b 5, Hev b 6.02) in excess of 1 µg g,1, which is believed to be a clinically relevant threshold. Among the examination gloves, 25 of 30 (83%) exceeded this level. Conclusions, This study shows that NRL allergen levels are present in the majority of examination gloves used by healthcare workers in Singapore at levels high enough to cause NRL allergy among sensitized persons. The information can serve as evidence for a possible requirement for manufacturers to produce gloves with low NRL allergen levels and to state the allergen level in gloves in the product information. [source]