Home About us Contact | |||
Gastric Tube Insertion (gastric + tube_insertion)
Selected AbstractsThe Laryngeal Mask Airway SupremeTM, a single use laryngeal mask airway with an oesophageal vent.ANAESTHESIA, Issue 1 2009A randomised, anaesthetised patients, cross-over study with the Laryngeal Mask Airway ProSealTM in paralysed Summary The LMA SupremeTM is a new extraglottic airway device which brings together features of the LMA ProSealTM, FastrachTM and UniqueTM. We test the hypothesis that ease of insertion, oropharyngeal leak pressure, fibreoptic position and ease of gastric tube placement differ between the LMA ProSealTM and the LMA SupremeTM in paralysed anesthetised patients. Ninety-three females aged 19,71 years were studied. Both devices were inserted into each patient in random order. Two attempts were allowed. Digital insertion was used for the first attempt and guided insertion for the second attempt. Oropharyngeal leak pressure and fibreoptic position were determined during cuff inflation from 0 to 40 ml in 10 ml increments. Gastric tube insertion was attempted if there was no gas leak from the drain tube. First attempt and overall insertion success were similar (LMA ProSealTM, 92% and 100%; LMA SupremeTM 95% and 100%). Guided insertion was always successful following failed digital insertion. Oropharyngeal leak pressure was 4,8 ml higher for the LMA ProSealTM over the inflation range (p < 0.001). Intracuff pressure was 16,35 cm higher for the LMA ProSealTM when the cuff volume was 20,40 ml (p < 0.001). There was an increase in oropharyngeal leak pressure with increasing cuff volume from 10 to 30 ml for both devices, but no change from 0 to 10 ml and 30,40 ml. There were no differences in the fibreoptic position of the airway or drain tube. The first attempt and overall insertion success for the gastric tube was similar (LMA ProSealTM 91% and 100%; LMA SupremeTM 92% and 100%). We conclude that ease of insertion, gastric tube placement and fibreoptic position are similar for the LMA ProSealTM and LMA SupremeTM in paralysed, anaesthetised females, but oropharyngeal leak pressure and intracuff pressure are higher for the LMA ProSealTM. [source] The I-gel®, a single-use supraglottic airway device with a non-inflatable cuff and an esophageal vent: an observational study in childrenACTA ANAESTHESIOLOGICA SCANDINAVICA, Issue 3 2009L. BEYLACQ Background: The I-gel® is a new single-use supraglottic airway device with a non-inflatable cuff. It is composed of a thermoplastic elastomer and a soft gel-like cuff that adapts to the hypopharyngeal anatomy. Like the LMA-ProSeal, it has an airway tube and a gastric drain tube. Little is known about its efficiency in pediatric anesthesia. Methods: Fifty children above 30 kg, ASA I,II, undergoing a short-duration surgery were included in this prospective, observational study. We evaluated ease in inserting the I-gel®, seal pressure, gastric leak, complications during insertion and removal, ease in inserting the gastric tube and ventilatory parameters during positive pressure ventilation. Results: All devices were inserted at the first attempt. The mean seal pressure was 25 cmH2O. There was no gastric inflation and gastric tube insertion was achieved in all cases. The results appear similar to those in a previous study concerning laryngeal mask airway in terms of leak pressure and complication rates. Conclusion: Because the I-gel® has a very good insertion success rate and very few complications, it seems to be an efficient and safe device for pediatric airway management. [source] The ProSealTM laryngeal mask airway in childrenPEDIATRIC ANESTHESIA, Issue 3 2005M. LOPEZ-GIL MD Summary Background :,The ProSealTM (PLMA) is a new laryngeal mask device with a modified cuff to improve the seal and a drain tube to provide access to the gastrointestinal tract. We assessed the performance of the size 2 (which has no dorsal cuff) and size 3 (which has a dorsal cuff) in terms of insertion success, efficacy of seal, tidal volume, gas exchange, fiberoptic position, gastric tube placement and frequency of problems. Methods :,Eighty children undergoing minor surgery were studied (n = 40, size 2 PLMA, weight 10,25 kg; n = 40, size 3 PLMA, weight >25,50 kg). Induction was with remifentanil and propofol. Insertion was with the introducer tool and by experienced users. Maintenance was with propofol or sevoflurane and pressure controlled ventilation. Results :,The first-time and overall insertion success rate was 84 and 100%, respectively. Oropharyngeal leak pressure was 31 ± 5 cmH2O. There were no gastric or drain tube air leaks. Tidal volume and gas exchange was adequate in all patients, other than two brief episodes of hypoxia because of airway reflex activation. The vocal cords and epiglottis were visible in 99 and 80%, respectively, via the airway tube. The first-time and overall insertion success rate for gastric tube insertion was 87 and 100%, respectively. During maintenance, the PLMA was removed in one patient with airway reflex activation and another required epinephrine for bronchospasm. There were no differences in performance between the sizes 2 and 3 PLMA. Conclusion :,The PLMA is an effective airway device in children and isolates the glottis from the esophagus when correctly positioned. Despite the lack of a dorsal cuff, the performance of the size 2 was similar to the size 3 PLMA in the age groups tested. [source] Insertion and use of the LMA SupremeÔ in the prone position,ANAESTHESIA, Issue 2 2010A. M. López Summary We investigated whether insertion of an LMA SupremeÔ and its use for maintenance of anaesthesia is feasible in the prone position. Forty adult patients positioned themselves prone and were given propofol until the Bispectral Index was < 50. A size-4 LMA Supreme was inserted by experienced anaesthetists. Ease of insertion, ease of ventilation, efficacy of seal, ease of gastric tube insertion, blood staining, postoperative sore throat, and other complications were recorded. Insertion was successful at the first and second attempt in 37 (92.5%) and 3 (7.5%) patients, respectively. The mean (SD) insertion time was 21 (15) s. Oropharyngeal leak pressure was greater in females than males (29 (4) vs 25 (4) cmH2O, respectively, p = 0.01). Adequate ventilation was achieved in all patients. Gastric tube placement was successful in all patients. The frequency of blood staining and sore throat was 7.5% each. No other complications were noted. We conclude that use of the LMA Supreme in the prone position by experienced users is feasible. [source] A study of airway management using the ProSeal LMA® laryngeal mask airway compared with the tracheal tube on postoperative analgesia requirements following gynaecological laparoscopic surgeryANAESTHESIA, Issue 9 2007M. Hohlrieder Summary In a randomised double blind prospective study, we tested the hypothesis that postoperative pain is lower in patients who receive an ProSeal LMAÔ laryngeal mask airway compared with a tracheal tube. One hundred consecutive female patients (ASA I,II, 18,75 years) undergoing laparoscopic gynaecological surgery were divided into two equal-sized groups for airway management with the ProSeal LMA or tracheal tube. Anaesthesia management was identical for both groups and included induction of anaesthesia using propofol/fentanyl, and maintenance with propofol/remifentanil, muscle relaxation with rocuronium, positive pressure ventilation, gastric tube insertion, dexamethasone/tropisetron for anti-emetic prophylaxis, and diclofenac for pain prophylaxis. All types of postoperative pain were treated using intravenous patient-controlled analgesia (PCA) morphine. Patients and postoperative staff were unaware of the airway device used. Data were collected by a single blinded observer. We found that pain scores were lower for the ProSeal LMA at 2 h and 6 h but not at 24 h. Morphine requirements were lower for the ProSeal LMA by 30.4%, 30.6% and 23.3% at 2, 6 and 24 h, respectively. Nausea was less common with the ProSeal LMA than with the tracheal tube at 2 h and 6 h but not at 24 h. There were no differences in the frequency of vomiting, sore throat, dysphonia or dysphagia. We conclude that postoperative pain is lower for the ProSeal LMA than the tracheal tube in females undergoing gynaecological laparoscopic surgery. [source] |