Home About us Contact | |||
File Size (file + size)
Selected AbstractsInfluence of cervical preflaring on apical file size determinationINTERNATIONAL ENDODONTIC JOURNAL, Issue 7 2005J. D. Pecora Abstract Aim, To investigate the influence of cervical preflaring with different instruments (Gates-Glidden drills, Quantec Flare series instruments and LA Axxess burs) on the first file that binds at working length (WL) in maxillary central incisors. Methodology, Forty human maxillary central incisors with complete root formation were used. After standard access cavities, a size 06 K-file was inserted into each canal until the apical foramen was reached. The WL was set 1 mm short of the apical foramen. Group 1 received the initial apical instrument without previous preflaring of the cervical and middle thirds of the root canal. Group 2 had the cervical and middle portion of the root canals enlarged with Gates-Glidden drills sizes 90, 110 and 130. Group 3 had the cervical and middle thirds of the root canals enlarged with nickel-titanium Quantec Flare series instruments. Titanium-nitrite treated, stainless steel LA Axxess burs were used for preflaring the cervical and middle portions of root canals from group 4. Each canal was sized using manual K-files, starting with size 08 files with passive movements until the WL was reached. File sizes were increased until a binding sensation was felt at the WL, and the instrument size was recorded for each tooth. The apical region was then observed under a stereoscopic magnifier, images were recorded digitally and the differences between root canal and maximum file diameters were evaluated for each sample. Results, Significant differences were found between experimental groups regarding anatomical diameter at the WL and the first file to bind in the canal (P < 0.01, 95% confidence interval). The major discrepancy was found when no preflaring was performed (0.151 mm average). The LA Axxess burs produced the smallest differences between anatomical diameter and first file to bind (0.016 mm average). Gates-Glidden drills and Flare instruments were ranked in an intermediary position, with no statistically significant differences between them (0.093 mm average). Conclusions, The instrument binding technique for determining anatomical diameter at WL is not precise. Preflaring of the cervical and middle thirds of the root canal improved anatomical diameter determination; the instrument used for preflaring played a major role in determining the anatomical diameter at the WL. Canals preflared with LA Axxess burs created a more accurate relationship between file size and anatomical diameter. [source] A survey of interfacial forces used during filing of root canalsDENTAL TRAUMATOLOGY, Issue 3 2000J. D. Regan Abstract , The pattern of dentine removal during endodontic instrumentation is influenced by many factors including the interfacial forces applied by the operator. The aim of this study was to investigate the influence of operators and different sizes and types of instruments on the magnitude of these interfacial forces. Single-rooted teeth were mounted on a cantilevered aluminium beam to which two pairs of single element strain gauges were joined in a half-bridge configuration and mounted at right angles to each other. The strain gauges were connected to an analogue-to-digital converter fitted in a micro-computer via conditioning amplifiers. This enabled strains to be recorded over a period of time. Twenty operators instrumented root canals using a series of hand instruments for 1 min each. The mean interfacial forces used by operators demonstrated a wide variation ranging from 9.06 g to 149.42 g (range of forces from 0,331 g) but there was a consistency in the relative magnitude for each operator. The 20 operators could be divided into 13 groups which were significantly different (,=0.05) from each other. There were significant differences (,=0.05) between the forces used for each of the K-Flex files (15, 25, 35, 45, and 70), the force increasing with the file size. There was also a significant difference (,=0.05) in the forces used between the Flexofile (#25) and the #25 K-Flex and Hedström files. However, there was no significant difference between the K-Flex and Hedström files. [source] Liquidity, Labels and Medium-Term NotesFINANCIAL MARKETS, INSTITUTIONS & INSTRUMENTS, Issue 5 2002Donald J. Mullineaux We suggest that the medium-term note market provides an excellent laboratory for exploring the relationships between yield, liquidity, and the label affixed to a financial instrument. Crabbe and Turner (1995) examined the liquidity issue and uncovered the counter-intuitive result that issue size is unrelated to liquidity. Their study failed to examine a potential channel for a liquidity effect, however, in the form of multiple issues from a single, typically large, MTN registration filing. We find evidence that file size is significantly related to yield in a number of instances. Several other proxies for liquidity, such as frequency of issue, are also sometimes significantly related to yields. Contrary to Crabbe and Turner (1995), we find that labeling a security an MTN can have an impact on its yield. The label "note" also appears to matter for yield in some instances. [source] Influence of cervical preflaring on apical file size determinationINTERNATIONAL ENDODONTIC JOURNAL, Issue 7 2005J. D. Pecora Abstract Aim, To investigate the influence of cervical preflaring with different instruments (Gates-Glidden drills, Quantec Flare series instruments and LA Axxess burs) on the first file that binds at working length (WL) in maxillary central incisors. Methodology, Forty human maxillary central incisors with complete root formation were used. After standard access cavities, a size 06 K-file was inserted into each canal until the apical foramen was reached. The WL was set 1 mm short of the apical foramen. Group 1 received the initial apical instrument without previous preflaring of the cervical and middle thirds of the root canal. Group 2 had the cervical and middle portion of the root canals enlarged with Gates-Glidden drills sizes 90, 110 and 130. Group 3 had the cervical and middle thirds of the root canals enlarged with nickel-titanium Quantec Flare series instruments. Titanium-nitrite treated, stainless steel LA Axxess burs were used for preflaring the cervical and middle portions of root canals from group 4. Each canal was sized using manual K-files, starting with size 08 files with passive movements until the WL was reached. File sizes were increased until a binding sensation was felt at the WL, and the instrument size was recorded for each tooth. The apical region was then observed under a stereoscopic magnifier, images were recorded digitally and the differences between root canal and maximum file diameters were evaluated for each sample. Results, Significant differences were found between experimental groups regarding anatomical diameter at the WL and the first file to bind in the canal (P < 0.01, 95% confidence interval). The major discrepancy was found when no preflaring was performed (0.151 mm average). The LA Axxess burs produced the smallest differences between anatomical diameter and first file to bind (0.016 mm average). Gates-Glidden drills and Flare instruments were ranked in an intermediary position, with no statistically significant differences between them (0.093 mm average). Conclusions, The instrument binding technique for determining anatomical diameter at WL is not precise. Preflaring of the cervical and middle thirds of the root canal improved anatomical diameter determination; the instrument used for preflaring played a major role in determining the anatomical diameter at the WL. Canals preflared with LA Axxess burs created a more accurate relationship between file size and anatomical diameter. [source] In vitro antimicrobial effect of chlorhexidine-impregnated gutta percha points on Enterococcus faecalisINTERNATIONAL ENDODONTIC JOURNAL, Issue 2 2004J. N. Lui Abstract Aim, To evaluate the in vitro antimicrobial effect of chlorhexidine-impregnated gutta percha points, Roeko activ point (Roeko, Langenau, Germany) on Enterococcus faecalis. Methodology, Human maxillary premolar roots were prepared with .04 rotary ProFile instruments to a master apical file size 40, autoclave-sterilized and then infected with E. faecalis (ATCC 29212) for 3 weeks. Baseline controls were carried out verifying negligible effects of plain gutta percha cones on E. faecalis. Subsequent to intracanal placement of calcium hydroxide, ,activ points' or saline (positive control) and the 2-week incubation in 54 root specimens, dentine sampling at depths of 100 and 250 µm was carried out using .04 rotary ProFile instruments at sizes 60 and 90 to assess the quantity of bacteria present. Inactivating agents were used prior to sampling and the colony-forming units (CFU) of E. faecalis were then plate-counted after culturing. Statistical analysis was completed using the paired t -test. Results, In comparison to the positive control, treatment with calcium hydroxide (P = 0.000 and 0.000) or activ points (P = 0.000 and 0.002) produced significantly lower colony counts of E. faecalis at dentine depths of 100 and 250 µm, respectively. Calcium hydroxide (2.10 × 102 CFU mL,1) was significantly more effective than activ points (1.58 × 103 CFU mL,1) at 100 µm (P = 0.013), but not at 250 µm (P = 0.353). Neither of these two medications was able to eliminate E. faecalis completely. Conclusions, Chlorhexidine-impregnated activ points did not possess an in vitro inhibitory activity strong enough to eliminate E. faecalis completely from infected dentinal tubules. [source] Light and scanning electron microscopic evaluation of GlydeÔ File Prep in smear layer removalINTERNATIONAL ENDODONTIC JOURNAL, Issue 5 2003T. S. Lim Abstract Aim, To evaluate the effectiveness of GlydeÔ File Prep used in conjunction with sodium hypochlorite irrigation in the removal of smear layer produced during root canal instrumentation. Methodology, Thirty-nine extracted human teeth with single root canals were used. Access cavities were prepared and the teeth divided into three groups of 13 teeth each. Each group was treated by one of the three different regimes of irrigation and conditioning during root canal instrumentation. Group A: 0.5 mL of 1% NaOCl irrigation after each file size with an additional final irrigation of 10 mL 1% NaOCl; group B: 0.5 mL of 1% NaOCl irrigation after each file size with an additional final irrigation of 10 mL 17% EDTA; group C: GlydeÔ File Prep coated on each instrumentation file used in conjunction with 0.5 mL 1% NaOCl irrigation after each file size and an additional final irrigation of 10 mL 1% NaOCl. The teeth were then longitudinally grooved and sectioned. Root canal cleanliness was evaluated with the aid of a Nikon light microscope (×40 and ×100) and scanning electron microscope (×1000 and ×3000). The debris scores obtained at three canal regions were compared statistically within the same group and among different groups using repeated measurements of analysis of variance (anova) with Bonferroni adjustments and anova with posthoc Tukey HSD, respectively. Results, The canals treated with EDTA and GlydeÔ File Prep were significantly cleaner than those treated with NaOCl alone. The apical region of the root canals generally displayed more residual smear layer, but the difference was not significant. Conclusions, Used in conjunction with NaOCl irrigation, GlydeÔ File Prep was effective in removing smear layer produced during root canal instrumentation. [source] Evaluation of smear layer removal by EDTAC and sodium hypochlorite with ultrasonic agitationINTERNATIONAL ENDODONTIC JOURNAL, Issue 5 2002D. M. Z. Guerisoli Abstract Aim To evaluate smear layer removal by different irrigating solutions under ultrasonic agitation. Methodology Twenty recently extracted mandibular incisors with a single root canal were divided into four equal groups. Three groups were instrumented using the modified double-flared technique, the fourth remained unprepared. Each group was irrigated with either distilled water, 1.0% sodium hypochlorite alone or associated with 15% EDTAC between each file size. The final group was not instrumented but irrigated with 1.0% sodium hypochlorite and 15% EDTAC. A size 15 file energised by ultrasound was used with small amplitude filing movements against the canal walls in all groups. The teeth were split longitudinally and the roots measured to provide three sections of the same size (cervical, middle and apical). Samples were examined under the scanning electron microscope and assessed for the amount of smear layer by three independent and calibrated examiners. The scoring system ranged from 1 (no smear layer) to 4 (all areas covered by smear layer). Due to the non-parametric nature of the data, Friedman's test was used for statistical analysis. Results Canal walls were covered with smear layer in the group irrigated with 1% sodium hypochlorite alone and the group irrigated with distilled water. Canals irrigated with 1.0% sodium hypochlorite associated with 15% EDTAC had less smear layer throughout the canal (P < 0.001). There were no statistical differences for the amount of smear layer found on the cervical, middle and apical thirds when each group was analysed separately. Conclusions Under ultrasonic agitation, sodium hypochlorite associated with EDTAC removed the smear layer from root canal walls, whereas irrigation with distilled water or 1.0% sodium hypochlorite alone did not remove smear layer. [source] The distribution of file transmission duration in the webINTERNATIONAL JOURNAL OF COMMUNICATION SYSTEMS, Issue 5 2004R. Nossenson Abstract It is well known that the distribution of files transmission duration in the Web is heavy-tailed (A practical guide to Heavy Tails: Statistical Techniques and Application. Birkhauser: Boston, 1998; 3,26). This paper attempts to understand the reasons for this phenomenon by isolating the three major factors influencing the transmission duration: file size, network conditions and server load. We present evidence that the transmission-duration distribution (TDD) of the same file from the same server to the same client in the Web is Pareto and therefore heavy tailed. Furthermore, text files transmission delay for a specific client/server pair is not significantly affected by the file sizes: all files transmitted from the same server to the same client have very similar transmission duration distributions, regardless of their size. We use simulations to estimate the impact of network conditions and server load on the TDD. When the server and the client are on the same local network, the TDD of each file is usually Pareto as well (for server files and client requests that are distributed in a realistic way). By examining a wide-area network situation, we conclude that the network conditions do not have a major influence on the heavy-tailed behaviour of TDD. In contrast, the server load is shown to have a significant impact on the high variability of this distribution. Copyright © 2004 John Wiley & Sons, Ltd. [source] Embedding 3D models of biological specimens in PDF publicationsMICROSCOPY RESEARCH AND TECHNIQUE, Issue 11 2008Bernhard Ruthensteiner Abstract By providing two examples, the option for embedding 3D models in electronic versions of life science publications is presented. These examples, presumably representing the first such models published, are developmental stages of an evertebrate (Patella caerulea, Mollusca) and a vertebrate species (Psetta maxima, Teleostei) obtained from histological section series reconstruction processed with the software package Amira. These surface rendering models are particularly suitable for a PDF file because they can easily be transformed to a file format required and components may be conveniently combined and hierarchically arranged. All methodological steps starting from specimen preparation until embedding of resulting models in PDF files with emphasis on conversion of Amira data to the appropriate 3D file format are explained. Usability of 3D models in PDF documents is exemplified and advantages over 2D illustrations are discussed, including better explanation capabilities for spatial arrangements, higher information contents, and limiting options for disguising results by authors. Possibilities for additional applications reaching far beyond the examples presented are suggested. Problems such as long-term compatibility of file format and hardware plus software, editing and embedding of files, file size and differences in information contents between printed and electronic version will likely be overcome by technical development and increasing tendency toward electronic at the cost of printed publications. Since 3D visualization plays an increasing role in manifold disciplines of science and appropriate tools for the popular PDF format are readily available, we propose routine application of this way of illustration in electronic life science papers. Microsc. Res. Tech., 2008. © 2008 Wiley-Liss, Inc. [source] The distribution of file transmission duration in the webINTERNATIONAL JOURNAL OF COMMUNICATION SYSTEMS, Issue 5 2004R. Nossenson Abstract It is well known that the distribution of files transmission duration in the Web is heavy-tailed (A practical guide to Heavy Tails: Statistical Techniques and Application. Birkhauser: Boston, 1998; 3,26). This paper attempts to understand the reasons for this phenomenon by isolating the three major factors influencing the transmission duration: file size, network conditions and server load. We present evidence that the transmission-duration distribution (TDD) of the same file from the same server to the same client in the Web is Pareto and therefore heavy tailed. Furthermore, text files transmission delay for a specific client/server pair is not significantly affected by the file sizes: all files transmitted from the same server to the same client have very similar transmission duration distributions, regardless of their size. We use simulations to estimate the impact of network conditions and server load on the TDD. When the server and the client are on the same local network, the TDD of each file is usually Pareto as well (for server files and client requests that are distributed in a realistic way). By examining a wide-area network situation, we conclude that the network conditions do not have a major influence on the heavy-tailed behaviour of TDD. In contrast, the server load is shown to have a significant impact on the high variability of this distribution. Copyright © 2004 John Wiley & Sons, Ltd. [source] Evaluation of performance enhancing proxies in internet over satelliteINTERNATIONAL JOURNAL OF COMMUNICATION SYSTEMS, Issue 6 2003Navid Ehsan Abstract Performance enhancing proxies (PEPs) are widely used to improve the performance of TCP over high delay-bandwidth product links and links with high error probability. In this paper we analyse the performance of using TCP connection splitting in combination with web caching via traces obtained from a commercial satellite system. We examine the resulting performance gain under different scenarios, including the effect of caching, congestion, random loss and file sizes. We show, via analysing our measurements, that the performance gain from using splitting is highly sensitive to random losses and the number of simultaneous connections, and that such sensitivity is alleviated by caching. On the other hand, the use of a splitting proxy enhances the value of web caching in that cache hits result in much more significant performance improvement over cache misses when TCP splitting is used. We also compare the performance of using different versions of HTTP in such a system. Copyright © 2003 John Wiley & Sons, Ltd. [source] |