Extraction Sockets (extraction + socket)

Distribution by Scientific Domains

Kinds of Extraction Sockets

  • fresh extraction socket


  • Selected Abstracts


    Rationale for esthetic tissue preservation of a fresh extraction socket by an implant treatment concept simulating a tooth replantation

    DENTAL TRAUMATOLOGY, Issue 1 2010
    Georgia Trimpou
    A soft-tissue recession must be avoided, whether it is due to a compression of the peri-implant soft-tissue caused by an over-dimensioned restoration in the cervical collar of the provisional crown or to a too small dimensioned sulcus former. A simulation of the exact dimension of the lost tooth , especially on the cervical part of the new provisional restoration , is expected to preserve all relevant information and allows the design of a naturally looking emergence profile. Based on theoretical considerations and a case report, the authors intend to demonstrate that a near-naturally dimensioned sealing of the dento-gingival soft-tissue collar may initiate a tissue-maintaining healing process, similar to a tooth replantation. The natural dental crown, connected to an implant instead of the root, is applied for a tight sealing of the wound. If due to traumatic impact the tooth is no longer available, a naturally dimensioned crown restoration will serve as an alternative wound sealant. [source]


    Tissue alterations after tooth extraction with and without surgical trauma: a volumetric study in the beagle dog

    JOURNAL OF CLINICAL PERIODONTOLOGY, Issue 4 2008
    Stefan Fickl
    Abstract Objectives: The aim of this study is to evaluate whether tooth extraction without the elevation of a muco-periosteal flap has advantageous effects on the resorption rate after tooth extraction. Material and Methods: In five beagle dogs polyether impressions were taken before the surgery. The roots of the first and second pre-molars (P1 and P2) were extracted and the sites were assigned to one of the following treatments: treatment group (Tx) 1, no treatment; Tx 2, surgical trauma (flap elevation and repositioning); Tx 3, the extraction socket was filled with BioOss Collagen® and closed with a free soft-tissue graft; Tx 4, after flap elevation and repositioning, the extraction socket was treated with BioOss Collagen® and a free soft-tissue graft. Impressions were taken 2 and 4 months after surgery. The casts were scanned, matched together with baseline casts and evaluated with digital image analysis. Results: The "flapless groups" demonstrated significant lower resorption rates both when using socket-preservation techniques and without. Furthermore, socket-preservation techniques yielded better results compared with not treating the socket. Conclusion: The results demonstrate that leaving the periosteum in place decreases the resorption rate of the extraction socket. Furthermore, the treatment of the extraction socket with BioOss Collagen® and a free gingival graft seems beneficial in limiting the resorption process after tooth extraction. [source]


    Langerhans cell histiocytosis: oral/periodontal involvement in adult patients

    ORAL DISEASES, Issue 8 2009
    S Annibali
    Objective:, Langerhans cell histiocytosis (LCH) is a clonal proliferative multisystem disease. Although bone and mucosae have been classified as non-risk organs, their involvement may increase the risk of disease progression. Oral and periodontal lesions are burdened with a significant impairment of quality of life for associated signs, symptoms and loss of function. Most of information regards paediatric disease; the disease in adults has received limited attention. Subjects and Methods:, A total of 31 adult patients affected by immuno-histopathology confirmed LCH have been prospectively examined; attention was paid to the occurrence and characterization of oral lesions. Results:, Twelve patients developed oral lesions. Posterior regions of jawbones were always affected; the involvement of anterior regions was not constant. Unifocal oral involvement was significantly associated with multisystemic disease while multifocal lesions were associated with unisystemic disease. Oral disease presented with soft tissue ulcers (50% of cases), gingival bleeding (66.7%), pain (83.4%), periodontal damage (50%), tooth mobility (16.7%), non-healing extraction socket (8.3%); 41.6% of patients complained of negative outcomes on quality of life. Oral lesions were easily handled with local measures. Conclusions:, Posterior regions require attention; single oral lesions may be part of multisystemic disease; oral and periodontal lesions may be early signs of disease reactivation. [source]


    ,-tricalcium phosphate in the early phase of socket healing: an experimental study in the dog

    CLINICAL ORAL IMPLANTS RESEARCH, Issue 4 2010
    Mauricio G. Araújo
    Abstract Objectives: The aim of this experiment was to analyze processes involved in the incorporation of ,-tricalcium phospate (TCP) particles in host tissue during healing following tooth extraction and grafting. Material and methods: Five beagle dogs were used. Four premolars in the maxilla (3P3, 2P2) were hemi-sected, the distal roots were removed and the fresh extraction socket filled with TCP. The tooth extraction and grafting procedures were scheduled in such a way that biopsies representing 1 and 3 days, as well as 1, 2, and 4 weeks of healing could be obtained. Tissue elements such as cells, fibers, vessels, leukocytes and mineralized bone were determined. In deparaffinized sections structures and cells that expressed Tratarate resistant acid phosphate, alkaline phosphatase, and osteopontin were identified by the use of markers. Results: The porosities of the TCP particles were initially filled with erythrocytes that subsequently were replaced with mineralized bone. Some of the graft material was invaded by mesenchymal and inflammatory cells and disintegrated. Thus, small membrane bound granules appeared in the granulation tissue and the provisional matrix. In the process of hard tissue formation, partly mineralized (modified) TCP particles became surrounded by ridges of woven bone. Conclusions: It was demonstrated that the early healing of an extraction socket that had been grafted with ,-TCP involved (i) the formation of a coagulum that was (ii) replaced with granulation tissue and a provisional matrix in which (iii) woven bone could form. In this process the biomaterial was apparently involved. To cite this article: Araújo MG, Liljenberg B, Lindhe J. ,-tricalcium phosphate in the early phase of socket healing: an experimental study in the dog. Clin. Oral Impl. Res. 21, 2010; 445,454. doi: 10.1111/j.1600-0501.2009.01876.x [source]


    A prospective, randomized-controlled clinical trial to evaluate bone preservation using implants with different geometry placed into extraction sockets in the maxilla

    CLINICAL ORAL IMPLANTS RESEARCH, Issue 1 2010
    Mariano Sanz
    Abstract Aim: The primary objective of this study was to determine the association between the size of the void established by using two different implant configurations and the amount of buccal/palatal bone loss that occurred during 16 weeks of healing following their installation into extraction sockets. Material and methods: The clinical trial was designed as a prospective, randomized-controlled parallel-group multicenter study. Adults in need of one or more implants replacing teeth to be removed in the maxilla within the region 15,25 were recruited. Following tooth extraction, the site was randomly allocated to receive either a cylindrical (group A) or a tapered implant (group B). After implant installation, a series of measurements were made to determine the dimension of the ridge and the void between the implant and the extraction socket. These measurements were repeated at the re-entry procedure after 16 weeks. Results: The study demonstrated that the removal of single teeth and the immediate placement of an implant resulted in marked alterations of the dimension of the buccal ridge (43% and 30%) and the horizontal (80,63%) as well as the vertical (69,65%) gap between the implant and the bone walls. Although the dimensional changes were not significantly different between the two-implant configurations, both the horizontal and the vertical gap changes were greater in group A than in group B. Conclusions: Implant placement into extraction sockets will result in significant bone reduction of the alveolar ridge. To cite this article: Sanz M, Cecchinato D, Ferrus J, Pjetursson EB, Lang NP, Jan L. A prospective, randomized-controlled clinical trial to evaluate bone preservation using implants with different geometry placed into extraction sockets in the maxilla. Clin. Oral Impl. Res. 21, 2009; 13,21. [source]


    A prospective clinical study of non-submerged immediate implants: clinical outcomes and esthetic results

    CLINICAL ORAL IMPLANTS RESEARCH, Issue 5 2007
    Stephen T. Chen
    Abstract Objectives: To evaluate healing of marginal defects in immediate transmucosal implants grafted with anorganic bovine bone, and to assess mucosal and radiographic outcomes 3,4 years following restoration. Material and methods: Thirty immediate transmucosal implants in maxillary anterior extraction sites of 30 patients randomly received BioOssÔ (N=10; BG), BioOssÔ and resorbable collagen membrane (N=10; BG+M) or no graft (N=10; control). Results: Vertical defect height (VDH) reductions of 81.2±5%, 70.5±17.4% and 68.2±16.6%, and horizontal defect depth (HDD) reductions of 71.7±34.3%, 81.7±33.7% and 55±28.4% were observed for BG, BG+M and control groups, respectively, with no significant inter-group differences. Horizontal resorption was significantly greater in control group (48.3±9.5%) when compared with BG (15.8±16.9%) and BG+M (20±21.9%) groups (P=0.000). Ten sites (33.3%) exhibited recession of the mucosa after 6 months; eight (26.7%) had an unsatisfactory esthetic result post-restoration due to recession. Mucosal recession was significantly associated (P=0.032) with buccally positioned implants (HDD 1.1±0.3 mm) when compared with lingually positioned implants (HDD 2.3±0.6 mm). In 19 patients followed for a mean of 4.0±0.7 years, marginal mucosa and bone levels remained stable following restoration. Conclusion: BioOssÔ significantly reduced horizontal resorption of buccal bone. There is a risk of mucosal recession and adverse soft tissue esthetics with immediate implant placement. However, this risk may be reduced by avoiding a buccal position of the implant in the extraction socket. [source]


    Modeling of the buccal and lingual bone walls of fresh extraction sites following implant installation

    CLINICAL ORAL IMPLANTS RESEARCH, Issue 6 2006
    Mauricio G. Araújo
    Abstract Objective: To determine whether the reduction of the alveolar ridge that occurs following tooth extraction and implant placement is influenced by the size of the hard tissue walls of the socket. Material and methods: Six beagle dogs were used. The third premolar and first molar in both quadrants of the mandible were used. Mucoperiostal flaps were elevated and the distal roots were removed. Implants were installed in the fresh extraction socket in one side of the mandible. The flaps were replaced to allow a semi-submerged healing. The procedure was repeated in the contra later side of the mandible after 2 months. The animals were sacrificed 1 month after the final implant installation. The mandibles were dissected, and each implant site was removed and processed for ground sectioning. Results: Marked hard tissue alterations occurred during healing following tooth extraction and implant installation in the socket. The marginal gap that was present between the implant and the walls of the socket at implantation disappeared as a result of bone fill and resorption of the bone crest. The modeling in the marginal defect region was accompanied by marked attenuation of the dimensions of both the delicate buccal and the wider lingual bone wall. Bone loss at molar sites was more pronounced than at the premolar locations. Conclusion: Implant placement failed to preserve the hard tissue dimension of the ridge following tooth extraction. The buccal as well as the lingual bone walls were resorbed. At the buccal aspect, this resulted in some marginal loss of osseointegration. [source]


    Tissue modeling following implant placement in fresh extraction sockets

    CLINICAL ORAL IMPLANTS RESEARCH, Issue 6 2006
    Mauricio G. Araújo
    Abstract Objective: To study whether osseointegration once established following implant placement in a fresh extraction socket may be lost as a result of tissue modeling. Material and methods: Seven beagle dogs were used. The third and fourth premolars in both quadrants of the mandible were used as experimental teeth. Buccal and lingual full-thickness flaps were elevated and distal roots were removed. Implants were installed in the fresh extraction socket. Semi-submerged healing of the implant sites was allowed. In five dogs, the experimental procedure was first performed in the right side of the mandible and 2 months later in the left mandible. These five animals were sacrificed 1 month after the final implant installation. In two dogs, the premolar sites on both sides of the mandible were treated in one surgical session and biopsies were obtained immediately after implant placement. All biopsies were processed for ground sectioning and stained. Results: The void that existed between the implant and the socket walls at surgery was filled at 4 weeks with woven bone that made contact with the SLA surface. In this interval, (i) the buccal and lingual bone walls underwent marked surface resorption and (ii) the height of the thin buccal hard tissue wall was reduced. The process of healing continued, and the buccal bone crest shifted further in the apical direction. After 12 weeks, the buccal crest was located>2 mm apical of the marginal border of the SLA surface. Conclusion: The bone-to-implant contact that was established during the early phase of socket healing following implant installation was in part lost when the buccal bone wall underwent continued resorption. [source]


    Immediate implants at fresh extraction sockets: an experimental study in the beagle dog comparing four different implant systems.

    JOURNAL OF CLINICAL PERIODONTOLOGY, Issue 8 2010
    Soft tissue findings
    de Sanctis M, Vignoletti F, Discepoli N, Muñoz F, Sanz M. Immediate implants at fresh extraction sockets: an experimental study in the beagle dog comparing four different implant systems. Soft tissue findings. J Clin Periodontol 2010; 37: 769-776 doi: 10.1111/j.1600-051X.2010.01570.x. Abstract Objectives: To evaluate whether different implants placed immediately upon tooth extraction may affect the dimension and composition of the peri-implant soft tissues. Material and Methods: Eight beagle dogs received implants randomly installed into the distal socket of 3P3 and 4P4. Four commercially available implant systems were evaluated: 3i Osseotite Certain straight; Astra MicroThreadÔ -OsseoSpeedÔ; Thommen SPI Element®; and Straumann ITI standard. Each animal provided four test implant sites. All animals were sacrificed 6 weeks after implant placement, providing specimens for the evaluation of the soft tissue dimensions by histometric analysis. Results: The biological width at 6 weeks after implant placement consisted of a junctional epithelium measuring between 2 and 2.7 mm and a connective tissue component between 1 and 1.8 mm with no statistical differences among the four implant systems. Conclusion: This study failed to demonstrate differences in the soft tissue healing outcome when placing four different implant systems into fresh extraction sockets. Nevertheless, the length of the epithelium achieved with the four implant systems is longer than what has been reported when placing implants in healed-ridge experimental models. [source]


    Immediate implants at fresh extraction sockets: bone healing in four different implant systems

    JOURNAL OF CLINICAL PERIODONTOLOGY, Issue 8 2009
    Massimo De Sanctis
    Abstract Objectives: To describe the differences in bone healing, when placing four different implant systems in fresh extraction sockets. Material and Methods: Eight beagle dogs received implants randomly installed into the distal socket of three P3 and four P4. Four-implant systems were evaluated. Each animal provided four test implant sites. All animals were sacrificed at 6 weeks after implant placement, providing specimens for histo-morphometric analysis of bone to implant contact (BIC), bone area, new bone formation, as well as histometric measurements of the ridge alterations. Results: No statistically significant difference was observed among the four-implant systems. The mean BIC % ranged between 58.5% and 72.1%. Bone modelling of the buccal plate was marked and amounted approximately to 2.5 mm, independently of the system used. Conclusion: This study failed to demonstrate differences in the healing pattern after 6 weeks when placing four different implant systems in fresh extraction sockets. In spite of achieving predictable osteointegration with the four implants studied, the occurrence of buccal bone resorption may limit the use of this surgical approach. [source]


    Early healing of implants placed into fresh extraction sockets: an experimental study in the beagle dog.

    JOURNAL OF CLINICAL PERIODONTOLOGY, Issue 3 2009
    De novo bone formation
    Abstract Objectives: Describe the early phases of tissue integration in implants placed into fresh extraction sockets and test whether a new implant surface nano-topography (DCD nano-particles, NanotiteÔ) promotes early osseointegration when compared with minimally rough surface implants (DAE, Osseotite®). Material and Methods: Sixteen beagle dogs received 64 test and control implants randomly installed into the distal socket of 3P3 and 4P4. Histomorphometric analysis of bone to implant contact (BIC) and bone area was performed at 4 h, 1, 2, 4 and 8 weeks. Results: Wound healing initiated with a coagulum that was substituted by a provisional matrix at 1 week. Bone formation started concomitant to a marked bone resorption. At 2 weeks, woven bone formation was evident and gradually remodelled into lamellar bone at 4 and 8 weeks. BIC increased similarly throughout the study in both groups with a tendency to higher percentages for the test devices at 2 and 4 weeks. The influence of the DCD nano-particles was more evident at the fourth premolar site. Conclusion: Osseointegration occurred similarly at both implant groups, although the socket dimension appeared to influence bone healing. It is suggested that the enhanced nano-topography has a limited effect in the immediate implant surgical protocol. [source]


    Volumetric analysis of extraction sockets using cone beam computed tomography: a pilot study on ex vivo jaw bone

    JOURNAL OF CLINICAL PERIODONTOLOGY, Issue 11 2007
    Jimoh Olubanwo Agbaje
    Abstract Aim: The aim of this study was to determine the accuracy of volumetric analysis of extraction sockets using cone beam computed tomography (CBCT). Material and Methods: The volume of 40 dental alveoli in nine dry skull specimens (four mandibles and five maxillae) was determined by measuring the volume of the tooth socket impression using the water displacement technique. This was considered as the gold standard. Then, the tooth socket was scanned with CBCT and data were uploaded in the semi-automated Livewire® segmentation software. The software segments the tooth socket in consecutive 1 mm-thick two-dimensional slices. After segmentation, the total volume of the delineated socket was computed. The statistical difference between direct volumetric measurements and those obtained with CBCT imaging was assessed using the Student paired t -test. Result: The mean socket volume of the skull specimens was 227±91 mm3 when obtained by direct measurement and 225±90 mm3 when obtained by CBCT imaging. Student paired t -test showed no significant differences between both volume measurements (p>0.1). Conclusions: CBCT permits imaging of anatomical structures in three planes and allows for reliable volume estimates. The results should be verified in clinical circumstances and might have potential applicability for evaluation of extraction socket healing under different conditions. [source]


    Immediate Implant Placement: Clinical Decisions, Advantages, and Disadvantages

    JOURNAL OF PROSTHODONTICS, Issue 7 2008
    Monish Bhola DDS
    Abstract Implant placement in fresh extraction sockets in conjunction with appropriate guided bone regeneration is well documented. The decision to extract teeth and replace them with immediate implants is determined by many factors, which ultimately affect the total treatment plan. The goal of this article is to review some of the important clinical considerations when selecting patients for immediate implant placement, and to discuss the advantages and disadvantages of this mode of therapy. [source]


    Interventions for replacing missing teeth: bone augmentation techniques for dental implant treatment

    AUSTRALIAN DENTAL JOURNAL, Issue 1 2009
    M Esposito
    Background:, Dental implants require sufficient bone to be adequately stabilized. For some patients implant treatment would not be an option without bone augmentation. A variety of materials and surgical techniques are available for bone augmentation. Objectives:, General objectives: To test the null hypothesis of no difference in the success, function, morbidity and patient satisfaction between different bone augmentation techniques for dental implant treatment. Specific objectives: (A) to test whether and when augmentation procedures are necessary; (B) to test which is the most effective augmentation technique for specific clinical indications. Trials were divided into three broad categories according to different indications for the bone augmentation techniques: (1) major vertical or horizontal bone augmentation or both; (2) implants placed in extraction sockets; (3) fenestrated implants. Search strategy:, The Cochrane Oral Health Group's Trials Register, the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE and EMBASE were searched. Several dental journals were handsearched. The bibliographies of review articles were checked, and personal references were searched. More than 55 implant manufacturing companies were also contacted. Last electronic search was conducted on 9 January 2008. Selection criteria:, Randomized controlled trials (RCTs) of different techniques and materials for augmenting bone for implant treatment reporting the outcome of implant therapy at least to abutment connection. Data collection and analysis:, Screening of eligible studies, assessment of the methodological quality of the trials and data extraction were conducted independently and in duplicate. Authors were contacted for any missing information. Results were expressed as random-effects models using mean differences for continuous outcomes and odd ratios for dichotomous outcomes with 95% confidence intervals. The statistical unit of the analysis was the patient. Main results:, Seventeen RCTs out of 40 potentially eligible trials reporting the outcome of 455 patients were suitable for inclusion. Since different techniques were evaluated in different trials, no meta-analysis could be performed. Ten trials evaluated different techniques for vertical or horizontal bone augmentation or both. Four trials evaluated different techniques of bone grafting for implants placed in extraction sockets and three trials evaluated different techniques to treat bone dehiscence or fenestrations around implants. Authors' conclusions:, Major bone grafting procedures of resorbed mandibles may not be justified. Bone substitutes (Bio-Oss or Cerasorb) may replace autogenous bone for sinus lift procedures of atrophic maxillary sinuses. Various techniques can augment bone horizontally and vertically, but it is unclear which is the most efficient. It is unclear whether augmentation procedures at immediate single implants placed in fresh extraction sockets are needed, and which is the most effective augmentation procedure, however, sites treated with barrier plus Bio-Oss showed a higher position of the gingival margin when compared to sites treated with barriers alone. Non-resorbable barriers at fenestrated implants regenerated more bone than no barriers, however it remains unclear whether such bone is of benefit to the patient. It is unclear which is the most effective technique for augmenting bone around fenestrated implants. Bone morphogenetic proteins may enhance bone formation around implants grafted with Bio-Oss. Titanium may be preferable to resorbable screws to fixate onlay bone grafts. The use of particulate autogenous bone from intraoral locations, also taken with dedicated aspirators, might be associated with an increased risk of infective complications. These findings are based on few trials including few patients, sometimes having short follow up, and often being judged to be at high risk of bias. [source]


    Collagen membranes at immediate implants: a histomorphometric study in dogs

    CLINICAL ORAL IMPLANTS RESEARCH, Issue 9 2010
    Marco Caneva
    Abstract Aim: To evaluate the influence of resorbable membranes on hard tissue alterations and osseointegration at implants placed into extraction sockets in a dog model. Material and methods: In the mandibular premolar region, implants were installed immediately into the extraction sockets of six Labrador dogs. Collagen-resorbable membranes were placed at the test sites, while the control sites were left uncovered. Implants were intended to heal in a submerged mode. After 4 months of healing, the animals were sacrificed, and ground sections were obtained for histomorphometric evaluation. Results: After 4 months of healing, a control implant was not integrated (n=5). Both at the test and at the control sites, bone resorption occurred. While the most coronal bone-to-implant contact was similar between the test and the control sites, the alveolar bone crest outline was maintained to a higher degree at the buccal aspect of the test sites (loss: 1.7 mm) compared with the control sites (loss: 2.2 mm). Conclusions: The use of collagen-resorbable membranes at implants immediately placed into extraction sockets contributed to a partial (23%) preservation of the buccal outline of the alveolar process. To cite this article: Caneva M, Botticelli D, Salata LA, Souza SLS, Carvalho Cardoso L, Lang NP. Collagen membranes at immediate implants: a histomorphometric study in dogs. Clin. Oral Impl. Res. 21, 2010; 891,897. doi: 10.1111/j.1600-0501.2010.01946.x [source]


    A prospective, randomized-controlled clinical trial to evaluate bone preservation using implants with different geometry placed into extraction sockets in the maxilla

    CLINICAL ORAL IMPLANTS RESEARCH, Issue 1 2010
    Mariano Sanz
    Abstract Aim: The primary objective of this study was to determine the association between the size of the void established by using two different implant configurations and the amount of buccal/palatal bone loss that occurred during 16 weeks of healing following their installation into extraction sockets. Material and methods: The clinical trial was designed as a prospective, randomized-controlled parallel-group multicenter study. Adults in need of one or more implants replacing teeth to be removed in the maxilla within the region 15,25 were recruited. Following tooth extraction, the site was randomly allocated to receive either a cylindrical (group A) or a tapered implant (group B). After implant installation, a series of measurements were made to determine the dimension of the ridge and the void between the implant and the extraction socket. These measurements were repeated at the re-entry procedure after 16 weeks. Results: The study demonstrated that the removal of single teeth and the immediate placement of an implant resulted in marked alterations of the dimension of the buccal ridge (43% and 30%) and the horizontal (80,63%) as well as the vertical (69,65%) gap between the implant and the bone walls. Although the dimensional changes were not significantly different between the two-implant configurations, both the horizontal and the vertical gap changes were greater in group A than in group B. Conclusions: Implant placement into extraction sockets will result in significant bone reduction of the alveolar ridge. To cite this article: Sanz M, Cecchinato D, Ferrus J, Pjetursson EB, Lang NP, Jan L. A prospective, randomized-controlled clinical trial to evaluate bone preservation using implants with different geometry placed into extraction sockets in the maxilla. Clin. Oral Impl. Res. 21, 2009; 13,21. [source]


    Clinical outcome of submerged vs. non-submerged implants placed in fresh extraction sockets

    CLINICAL ORAL IMPLANTS RESEARCH, Issue 12 2009
    Luca Cordaro
    Abstract Aim: The aim of this study was to compare the clinical outcome of submerged vs. non-submerged tapered implants placed into fresh extraction sockets. Materials and methods: A prospective, controlled, multicenter, randomized, clinical trial has been performed in two centers in Rome and Torino (Italy). Thirty healthy patients were recruited according to the following inclusion criteria: need for an immediate post extraction implant, ages between 18 and 70, horizontal defect depth <2 mm, smokers <10 cigarettes/day and absence of any circumstance or condition that could represent contraindications to implant surgery. The patients were randomly allocated to submerged or non-submerged treatment groups immediately after flap elevation and tooth extraction. Submerged implants were exposed 8 weeks after the first surgery; all implants were loaded with provisional restorations 12 weeks after the first surgery and with definitive restoration 12 weeks thereafter. Clinical and radiographic parameters were evaluated at baseline, at implant loading and at the 1-year follow-up visit. Results: The results showed statistically significant differences between the two groups in the mean value of keratinized tissue (KT) height after surgery that was significantly reduced for submerged implants when compared with transmucosal implants (mean reduction of KT at year follow-up: T group 0.2 mm, S group 1.3 mm; P=0.007). Conclusion: Similar outcomes were found for submerged and non-submerged implants placed in fresh extraction sockets with a horizontal peri-implant defect smaller than 2 mm, except for a reduction of KT in the submerged group. Either with a submerged or a non-submerged procedure, 1 mm of mean soft tissue recession is seen after 1 year when compared with the pre-extraction situation. [source]


    Double-blind randomized controlled trial study on post-extraction immediately restored implants using the switching platform concept: soft tissue response.

    CLINICAL ORAL IMPLANTS RESEARCH, Issue 4 2009
    Preliminary report
    Abstract Aim: To evaluate the soft tissue response to immediately placed implants using the platform switching concept. Material and methods: In 22 patients, 22 implants of 5.5 mm platform diameter were placed immediately into fresh extraction sockets in maxillae without compromised bone tissue. Eventual post-extraction bone defects were filled using bovine bone matrix mixed with collagen. Immediately after insertion, implants were randomly divided: 11 implants were connected with a 3.8 mm diameter abutment (test group) and 11 with a 5.5 mm diameter abutment (control group). A provisional crown was adapted and adjusted for non-functional immediate positioning. Two months later, definitive prosthetic rehabilitation was performed. Periodontal parameter, buccal peri-implant mucosal changes (REC), mesial and distal papilla height (PH) and vertical height of jumping distance (VHG) were measured at the time of implant placement, of definitive prosthesis insertion and every 6 months thereafter. Results: The mean follow-up was 25 months. All implants were clinically osseointegrated. The test group showed a +0.18 mm REC gain. PH gain was +0.045 mm on average. The mean values were statistically significant (P,0.005) compared with the control group (PH=,0.88 mm; REC=,0.45 mm). No difference between the two groups in periodontal parameters was found. The mean value of bone filling was 7.51 mm in the test group (97.4% of VHG) and 8.57 mm in the control group (95.2% of VHG). No statistically significant difference was found between the two groups. Conclusions: This study suggests that, in a limited time period of 2 years, immediately placed implants with subsequent platform switching can provide peri-implant tissue stability. [source]


    Histomorphometric analysis of extraction sockets augmented with Bio-Oss Collagen after a 6-week healing period: A prospective study

    CLINICAL ORAL IMPLANTS RESEARCH, Issue 12 2008
    Susanne Heberer
    First page of article [source]


    Implants in fresh extraction sockets: a prospective 5-year follow-up clinical study

    CLINICAL ORAL IMPLANTS RESEARCH, Issue 12 2008
    Daniele Botticelli
    Abstract Objective: The aim of this prospective study was to evaluate the 5-year clinical outcome of the ,immediate implants.' Material and methods: One week after the cementation of the prosthesis, a clinical baseline examination was carried out. Clinical measurements were performed of the following: plaque, mucositis, probing pocket depth, and soft tissue position. The height of the keratinized mucosa was measured at the buccal/lingual aspects. Standardized intra-oral radiographs were taken. The marginal level of bone to implant contact [radiographic (Rx) bone level] was measured, and Rx bone level change over time was evaluated. The clinical/radiographic measurements were repeated on a yearly basis. The subjects were enrolled in a carefully supervised oral hygiene program. Results and conclusion: It was demonstrated that ,immediate implants' that were loaded after 5,7 months had a high success rate. During the 5-year interval, no implant was lost, and the mean Rx bone level at the implants was maintained or even improved. The plaque and mucositis scores were low (<20%) at baseline and at all re-examinations. Implant sites located adjacent to the teeth showed bone gain during the initial period while sites that were facing edentulous zones lost some bone. [source]


    Soft and hard tissue assessment of immediate implant placement: a case series

    CLINICAL ORAL IMPLANTS RESEARCH, Issue 2 2007
    Gintaras Juodzbalys
    Abstract Objectives: The aim of this prospective study was to evaluate clinically and radiographically the success and esthetic result of immediate implant placement at the time of extraction. Material and methods: Twelve patients with 14 titanium screw-shaped implants (13,16 mm length and 4.3 or 5 mm diameters) were placed in the extraction sockets. Defects after implant placement were recorded, and then filled up with deproteinized bovine bone mineral, bioabsorbable collagen membrane, and absorbable pins. The defect was again re-evaluated at second-stage surgery. Clinical and radiographic parameters of the peri-implant conditions were assessed at the moment of prosthesis placement and at 1-year follow-up. Results: The cumulative implant survival and success rate was 100% after a 1-year observation period. Analysis of the esthetic result showed that the mean pink esthetic score (PES) was 11.1 (SD 1.35) at 1-year follow-up. At 1 year, 64.3% papillae had a score of 2 and the remaining 35.7% score 3 according to the Jemt (1997) papillary index. Optimal value of width of the keratinized mucosa was recorded in 13 (92.9%) implant cases in both periods of follow-up. At 1-year follow-up, the linear distance between implant-shoulder to the bone peaks remains stable with a mean of 2.62±0.2 mm at the mesial and 2.9±0.58 mm at the distal aspect. Conclusion: Careful evaluation of potential extraction sites before immediate implant installation promotes optimal implant esthetics. [source]


    Tissue modeling following implant placement in fresh extraction sockets

    CLINICAL ORAL IMPLANTS RESEARCH, Issue 6 2006
    Mauricio G. Araújo
    Abstract Objective: To study whether osseointegration once established following implant placement in a fresh extraction socket may be lost as a result of tissue modeling. Material and methods: Seven beagle dogs were used. The third and fourth premolars in both quadrants of the mandible were used as experimental teeth. Buccal and lingual full-thickness flaps were elevated and distal roots were removed. Implants were installed in the fresh extraction socket. Semi-submerged healing of the implant sites was allowed. In five dogs, the experimental procedure was first performed in the right side of the mandible and 2 months later in the left mandible. These five animals were sacrificed 1 month after the final implant installation. In two dogs, the premolar sites on both sides of the mandible were treated in one surgical session and biopsies were obtained immediately after implant placement. All biopsies were processed for ground sectioning and stained. Results: The void that existed between the implant and the socket walls at surgery was filled at 4 weeks with woven bone that made contact with the SLA surface. In this interval, (i) the buccal and lingual bone walls underwent marked surface resorption and (ii) the height of the thin buccal hard tissue wall was reduced. The process of healing continued, and the buccal bone crest shifted further in the apical direction. After 12 weeks, the buccal crest was located>2 mm apical of the marginal border of the SLA surface. Conclusion: The bone-to-implant contact that was established during the early phase of socket healing following implant installation was in part lost when the buccal bone wall underwent continued resorption. [source]