Home About us Contact | |||
Endorectal Coil (endorectal + coil)
Selected AbstractsProstate cancer detection with multi-parametric MRI: Logistic regression analysis of quantitative T2, diffusion-weighted imaging, and dynamic contrast-enhanced MRIJOURNAL OF MAGNETIC RESONANCE IMAGING, Issue 2 2009Deanna L. Langer MSc Abstract Purpose To develop a multi-parametric model suitable for prospectively identifying prostate cancer in peripheral zone (PZ) using magnetic resonance imaging (MRI). Materials and Methods Twenty-five radical prostatectomy patients (median age, 63 years; range, 44,72 years) had T2-weighted, diffusion-weighted imaging (DWI), T2-mapping, and dynamic contrast-enhanced (DCE) MRI at 1.5 Tesla (T) with endorectal coil to yield parameters apparent diffusion coefficient (ADC), T2, volume transfer constant (Ktrans) and extravascular extracellular volume fraction (ve). Whole-mount histology was generated from surgical specimens and PZ tumors delineated. Thirty-eight tumor outlines, one per tumor, and pathologically normal PZ regions were transferred to MR images. Receiver operating characteristic (ROC) curves were generated using all identified normal and tumor voxels. Step-wise logistic-regression modeling was performed, testing changes in deviance for significance. Areas under the ROC curves (Az) were used to evaluate and compare performance. Results The best-performing single-parameter was ADC (mean Az [95% confidence interval]: Az,ADC: 0.689 [0.675, 0.702]; Az,T2: 0.673 [0.659, 0.687]; Az,Ktrans: 0.592 [0.578, 0.606]; Az,ve: 0.543 [0.528, 0.557]). The optimal multi-parametric model, LR-3p, consisted of combining ADC, T2 and Ktrans. Mean Az,LR-3p was 0.706 [0.692, 0.719], which was significantly higher than Az,T2, Az,Ktrans, and Az,ve (P < 0.002). Az,LR-3p tended to be greater than Az,ADC, however, this result was not statistically significant (P = 0.090). Conclusion Using logistic regression, an objective model capable of mapping PZ tumor with reasonable performance can be constructed. J. Magn. Reson. Imaging 2009;30:327,334. © 2009 Wiley-Liss, Inc. [source] High-field MRSI of the prostate using a transmit/receive endorectal coil and gradient modulated adiabatic localizationJOURNAL OF MAGNETIC RESONANCE IMAGING, Issue 2 2009Jamie Near PhD Abstract Purpose To demonstrate in vivo magnetic resonance spectroscopic imaging (MRSI) of the human prostate at 4.0T using a transmit/receive endorectal coil and a pulse sequence designed specifically for this application. Materials and Methods A solid, reusable endorectal probe was designed for both radiofrequency transmission and reception. Finite difference time domain (FDTD) simulations were performed to characterize the coil's electric field distribution, and temperature measurements were performed in a beef tissue phantom to determine the coil's safe operating limit. The localization by selective adiabatic refocusing (LASER) pulse sequence was implemented using six gradient modulated offset independent adiabatic (GOIA) pulses for very sharp, B1 -insensitive voxel localization. Results Based on the simulations and temperature measurements, the coil's safe operating limit was conservatively estimated to be 1.0W for 15 minutes. The transition width of the GOIA pulse selection profiles was only 6% of the bandwidth, compared with 22% for a specific absorption rate (SAR)-matched conventional adiabatic pulse. Using the coil and pulse sequence described here, MRSI data were successfully acquired from a patient with biopsy-proven prostate cancer, with a nominal voxel size of 0.34 cc in a scan time of 15 minutes. Conclusion This work demonstrates the safe and effective use of a transmit/receive endorectal coil for in vivo MRSI of the prostate. J. Magn. Reson. Imaging 2009;30:335,343. © 2009 Wiley-Liss, Inc. [source] 3T MR of the prostate: Reducing susceptibility gradients by inflating the endorectal coil with a barium sulfate suspensionMAGNETIC RESONANCE IN MEDICINE, Issue 5 2007Yael Rosen Abstract Most prostate MRI/MRS examinations are performed with an endorectal coil inflated with air, leading to an air,tissue interface that induces magnetic susceptibility gradients within the gland. Inflation of the coil with a barium sulfate suspension is described and compared to inflation with air or liquid perfluorocarbon (PFC). The B0 field in the prostate gland was mapped for five healthy volunteers when the endorectal coil was inflated with each of the three agents. A marked decrease in the posterior-anterior (P-A) field gradient and a significant improvement in field homogeneity were evident in the presence of a barium suspension and PFC relative to air. MRS data acquired from the prostate gland in the presence of air, PFC, and a barium suspension in the endorectal coil showed similar trends, demonstrating improvement in line-widths and spectral resolution when the barium suspension or the PFC were inflating the endorectal coil. On this basis we conclude that a barium suspension provides an available, cheap, and safe alternative to PFC, and we suggest that inflating the endorectal coil with a barium suspension should be considered for prostate MR studies, especially at high field strengths (such as 3T). Magn Reson Med 57:898,904, 2007. © 2007 Wiley-Liss, Inc. [source] |