AF Recurrence (af + recurrence)

Distribution by Scientific Domains


Selected Abstracts


Persistence of Pulmonary Vein Isolation After Robotic Remote-Navigated Ablation for Atrial Fibrillation and its Relation to Clinical Outcome

JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, Issue 10 2010
STEPHAN WILLEMS M.D.
Robotic Remote Ablation for AF. Aims: A robotic navigation system (RNS, HansenÔ) has been developed as an alternative method of performing ablation for atrial fibrillation (AF). Despite the growing application of RNS-guided pulmonary vein isolation (PVI), its consequences and mechanisms of subsequent AF recurrences are unknown. We investigated the acute procedural success and persistence of PVI over time after robotic PVI and its relation to clinical outcome. Methods and Results: Sixty-four patients (60.7 ± 9.8 years, 53 male) with paroxysmal AF underwent robotic circumferential PVI with 3-dimensional left atrial reconstruction (NavXÔ). A voluntary repeat invasive electrophysiological study was performed 3 months after ablation irrespective of clinical course. Robotic PVI was successful in all patients without complication (fluoroscopy time: 23.5 [12,34], procedure time: 180 [150,225] minutes). Fluoroscopy time demonstrated a gradual decline but was significantly reduced after the 30th patient following the introduction of additional navigation software (34 [29,45] vs 12 [9,17] minutes; P < 0.001). A repeat study at 3 months was performed in 63% of patients and revealed electrical conduction recovery in 43% of all PVs. Restudied patients without AF recurrence (n = 28) showed a significantly lower number of recovered PVs (1 (0,2) vs 2 (2,3); P = 0.006) and a longer LA-PV conduction delay than patients with AF recurrences (n = 12). Persistent block of all PVs was associated with freedom from AF in all patients. At 3 months, 67% of patients were free of AF, while reablation of recovered PVs led to an overall freedom from AF in 81% of patients after 1 year. Conclusion: Robotic PVI for PAF is safe, effective, and requires limited fluoroscopy while yielding comparable success rates to conventional ablation approaches with PV reconduction as a common phenomenon associated with AF recurrences. (J Cardiovasc Electrophysiol, Vol. 21, pp. 1079-1084) [source]


The Impact of Age on the Electroanatomical Characteristics and Outcome of Catheter Ablation in Patients with Atrial Fibrillation

JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, Issue 9 2010
TA-CHUAN TUAN M.D.
Age and Atrial Fibrillation.,,Background: Previous studies have indicated that atrial fibrillation (AF) in patients over the age of 60 at diagnosis is a risk factor for a substantial increase in cardiovascular events. However, information about the impact of age on the atrial substrate and clinical outcome after catheter ablation of AF is limited. Methods: This study included 350 patients (53 ± 12 years, 254 males) who underwent circumferential pulmonary vein isolation (CPVI) of AF, guided by a NavX mapping system. The subjects were divided into three groups according to their age, as follows: Group I: age ,50 (n = 141), Group II: age = 51,64 (n = 149) and Group III: age ,65 years old (n = 60). The mean voltage and total activation time of the individual atria were obtained by using a NavX mapping system before ablation. Several parameters, including the gender, AF duration, and left atrial (LA) diameter were analyzed. Results: The younger age group had a significantly smaller LA diameter (Group I vs Group II vs Group III, 36.89 ± 7.11 vs 39.16 ± 5.65 vs 40.77 ± 4.95 mm, P = 0.002) and higher LA bipolar voltage (2.09 ± 0.83 vs 1.73 ± 0.73 vs 1.86 ± 0.67 mV, respectively, P = 0.024), compared with the older AF patients. The LA bipolar voltage exhibited a significant reduction when the patients became older, however, that did not occur in the right atrium. The incidence of an AF recurrence was higher in the older age group than in the younger age groups. A subgroup of patients with lone AF was analyzed and age was found to be an independent predictor of the AF recurrence after receiving the first CPVI in the multivariable model (P < 0.05). Conclusions: Age has a significant impact on the LA substrate properties and outcome of the catheter ablation of AF. (J Cardiovasc Electrophysiol, Vol. 21, pp. 966-972, September 2010) [source]


A Short-Term, Randomized, Double-Blind, Parallel-Group Study to Evaluate the Efficacy and Safety of Dronedarone versus Amiodarone in Patients with Persistent Atrial Fibrillation: The DIONYSOS Study

JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, Issue 6 2010
JEAN-YVES LE HEUZEY M.D.
Dronedarone versus Amiodarone in Patients with AF.,,Introduction: We compared the efficacy and safety of amiodarone and dronedarone in patients with persistent atrial fibrillation (AF). Methods: Five hundred and four amiodarone-naïve patients were randomized to receive dronedarone 400 mg bid (n = 249) or amiodarone 600 mg qd for 28 days then 200 mg qd (n = 255) for at least 6 months. Primary composite endpoint was recurrence of AF (including unsuccessful electrical cardioversion, no spontaneous conversion and no electrical cardioversion) or premature study discontinuation. Main safety endpoint (MSE) was occurrence of thyroid-, hepatic-, pulmonary-, neurologic-, skin-, eye-, or gastrointestinal-specific events, or premature study drug discontinuation following an adverse event. Results: Median treatment duration was 7 months. The primary composite endpoint was 75.1 and 58.8% with dronedarone and amiodarone, respectively, at 12 months (hazard ratio [HR] 1.59; 95% confidence interval [CI] 1.28,1.98; P < 0.0001), mainly driven by AF recurrence with dronedarone compared with amiodarone (63.5 vs 42.0%). AF recurrence after successful cardioversion was 36.5 and 24.3% with dronedarone and amiodarone, respectively. Premature drug discontinuation tended to be less frequent with dronedarone (10.4 vs 13.3%). MSE was 39.3 and 44.5% with dronedarone and amiodarone, respectively, at 12 months (HR = 0.80; 95% CI 0.60,1.07; P = 0.129), and mainly driven by fewer thyroid, neurologic, skin, and ocular events in the dronedarone group. Conclusion: In this short-term study, dronedarone was less effective than amiodarone in decreasing AF recurrence, but had a better safety profile, specifically with regard to thyroid and neurologic events and a lack of interaction with oral anticoagulants. (J Cardiovasc Electrophysiol, Vol. 21, pp. 597-605, June 2010) [source]


Triggering Pulmonary Veins: A Paradoxical Predictor for Atrial Fibrillation Recurrence After PV Isolation

JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, Issue 4 2010
YVES DE GREEF M.D.
Triggering Pulmonary Veins and Recurrence After Ablation.,Purpose: To identify procedural parameters predicting recurrence of atrial fibrillation (AF) after a first circumferential pulmonary vein isolation (CPVI). Methods: One hundred seventy-one patients undergoing CARTO-guided CPVI for recurrent AF with a left atrial (LA) diameter <45 mm were studied. Follow-up (symptoms and 7-day Holter) was performed at 1 and 3 months and every 3 months thereafter. Clinical and procedural characteristics between successful patients and patients undergoing repeat ablation were compared. In addition, procedural parameters of the first procedure were compared with parameters during repeat ablation. Results: After first CPVI, 80% of patients were free of AF without antiarrhythmic drugs after a follow-up (FU) of 28 ± 11 months (N = 136). Thirty-five patients (20%) had recurrence of AF of which 25 underwent repeat ablation (N = 25). Clinical characteristics did not differ between the successful and repeat group. A triggering vein during the index procedure was significantly more observed in the repeat group (56% vs 11%, P < 0.001). At repeat ablation, 2.6 ± 1.2 veins per patient were reconnected. Whereas there was no preferential reconnecting PV, all PVs triggering at index were reconnected (100%). Conclusions: (1) In patients with symptomatic recurrent AF, the presence of a triggering pulmonary vein during ablation is a paradoxical predictor for AF recurrence after PV isolation. (2) The consistent finding of reconnection of the triggering PV at repeat ablation, suggests that, in these patients, the triggering PV is the culprit vein and that reconnection invariably results in clinical AF recurrence. (3) The present study advocates a strategy of even more stringent PV isolation in case of a triggering PV. (J Cardiovasc Electrophysiol, Vol. 21, pp. 381,388, April 2010) [source]


Characteristics of Complex Fractionated Electrograms in Nonpulmonary Vein Ectopy Initiating Atrial Fibrillation/Atrial Tachycardia

JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, Issue 12 2009
LI-WEI LO M.D.
Background: Nonpulmonary vein (PV) ectopy initiating atrial fibrillation (AF)/atrial tachycardia (AT) is not uncommon in patients with AF. The relationship of complex fractionated atrial electrograms (CFAEs) and non-PV ectopy initiating AF/AT has not been assessed. We aimed to characterize the CFAEs in the non-PV ectopy initiating AF/AT. Methods: Twenty-three patients (age 53 ± 11 y/o, 19 males) who underwent a stepwise AF ablation with coexisting PV and non-PV ectopy initiating AF or AT were included. CFAE mapping was applied before and after the PV isolation in both atria by using a real-time NavX electroanatomic mapping system. A CFAE was defined as a fractionation interval (FI) of less than 120 ms over 8-second duration. A continuous CFAE (mostly, an FI < 50 ms) was defined as electrogram fractionation or repetitive rapid activity lasting for more than 8 seconds. Results: All patients (100%) with non-PV ectopy initiating AF or AT demonstrated corresponding continuous CFAEs at the firing foci. There was no significant difference in the FI among the PV ostial or non-PV atrial ectopy or other atrial CFAEs (54.1 ± 5.6, 58.3 ± 11.3, 52.8 ± 5.8 ms, P = 0.12). Ablation targeting those continuous CFAEs terminated the AF and AT and eliminated the non-PV ectopy in all patients (100%). During a follow-up of 7 months, 22% of the patients had an AF recurrence with PV reconnections. There was no recurrence of any ablated non-PV ectopy during the follow-up. Conclusion: The sites of the origin of the non-PV ectopies were at the same location as those of the atrial continuous CFAEs. Those non-PV foci were able to initiate and sustain AF/AT. By limited ablation targeting all atrial continuous CFAEs, the AF could be effectively eliminated. [source]


Prevalence, Predictors, and Prognosis of Atrial Fibrillation Early After Pulmonary Vein Isolation: Findings from 3 Months of Continuous Automatic ECG Loop Recordings

JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, Issue 10 2009
SANDEEP JOSHI M.D.
Introduction: Following pulmonary vein isolation (PVI) for atrial fibrillation (AF), early recurrences are frequent, benign and classified as a part of a "blanking period." This study characterizes early recurrences and determines implications of early AF following PVI. Methods and Results: Seventy-two consecutive patients (59.8 ± 10.7 years, 69% male) were studied following PVI for paroxysmal or persistent AF. Subjects were fitted with an external loop recorder for automatic, continuous detection of AF recurrence for 3 months. AF prevalence was highest 2 weeks after PVI (54%) and declined to an eventual low of 22%. A significant number (488, 34%) of recurrences were asymptomatic; however, all patients with ,1 AF event had ,1 symptomatic event. No clear predictor of early recurrence was identified. Forty-seven (65%) patients had at least 1 AF episode, predominantly (39 of 47 patients, 83%) within 2 weeks of PVI. Of the 33 patients who did not experience AF within the first 2 weeks, 85% (28/33) were complete responders (P = 0.03) at 12 months. Recurrence at any time within 3 months was not associated with procedural success or failure. Conclusions: Early AF recurrence peaks within the first few weeks after PVI, but continues at a lower level until the completion of monitoring. A blanking period of 3 months is justified to identify patients with AF recurrences that do not portend procedure failure. Freedom from AF in the first 2 weeks following ablation significantly predicts long-term AF freedom. [source]


Does Left Atrial Volume and Pulmonary Venous Anatomy Predict the Outcome of Catheter Ablation of Atrial Fibrillation?

JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, Issue 9 2009
IRENE HOF M.D.
Introduction: Preprocedural factors may be helpful in selecting patients with atrial fibrillation (AF) for treatment with catheter ablation and in making an assumption regarding their prognosis. The aims of this study were to investigate whether left atrial (LA) volume and pulmonary venous (PV) anatomy, evaluated by computed tomography (CT) prior to ablation, will predict AF recurrence following catheter ablation. Methods and Results: We included 146 patients (mean age 57 ± 11 years, 83% male) with symptomatic AF (55% paroxysmal, 18% persistent, 27% long-standing persistent). All patients underwent CT scanning prior to catheter ablation to evaluate LA volume and PV anatomy. Circumferential PV isolation was performed guided by Cartomerge electroanatomical mapping. The outcome was defined as complete success, improvement, or failure. After a mean follow-up of 19 ±7 months, complete success was achieved in 59 patients (40%), and 38 patients (26%) demonstrated improvement. LA volume was found to be an independent predictor of AF recurrence with an adjusted OR of 1.14 for every 10-mL increase in volume (95% CI 1.00,1.29, P = 0.047). PV variations were equally distributed among the different outcomes of the ablation procedure, and therefore univariate analysis did not identify PV anatomy as a predictor of outcome. Conclusion: LA volume is an independent predictor of AF recurrence after catheter ablation. Additionally, PV anatomy did not have any effect on the outcome. These findings suggest that an assessment of LA volume may be incorporated into the preprocedural evaluation of patients being considered for AF ablation. [source]


Biatrial Substrate Properties in Patients with Atrial Fibrillation

JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, Issue 11 2007
SHIH-LIN CHANG M.D.
Introduction: The atrial substrate plays an important role in the maintenance of atrial fibrillation (AF). Further investigation of the biatrial substrate may be helpful for understanding the mechanism of AF. The aim of this study was to investigate the properties of right and left atrial (RA and LA) substrate in AF patients and their impact on the catheter ablation. Methods: Biatrial electroanatomic mapping using a three-dimensional mapping system (NavX) was performed in 117 consecutive patients with paroxysmal (n = 99) and persistent (n = 18) AF. The biatrial voltage and total activation time (TAT) were obtained during sinus rhythm. Results: The LA had a lower voltage (1.6 ± 0.5 vs 2.0 ± 0.6 mV, P < 0.001) than the RA. The TAT correlated with the voltage (r =,0.65, P< 0.001). The patients with persistent AF had a lower atrial voltage, higher coefficient of variance for the LA voltage, longer LA TAT, and more extensive scar than those with paroxysmal. The patients with recurrent AF after catheter ablation had a lower LA voltage and higher incidence of LA scarring than those without recurrence. A scar located in the low anteroseptal or low posterior wall of LA was related to recurrence of AF. LA scarring was the independent predictor of AF recurrence after catheter ablation. Conclusion: The LA voltage was lower than the RA, and the atrial voltage correlated with the TAT. Electroanatomical remodeling of the atria could be crucial to the maintenance of AF. The LA substrate properties may play an important role in the recurrence of AF after catheter ablation of AF. [source]


Incidence of Atrial Arrhythmias Detected by Permanent Pacemakers (PPM) Post-Pulmonary Vein Antrum Isolation (PVAI) for Atrial Fibrillation (AF): Correlation with Symptomatic Recurrence

JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, Issue 6 2007
ATUL VERMA M.D.
Background: Studies examining AF recurrences post-PVAI base recurrence on patient reporting of symptoms. However, whether asymptomatic recurrences are common is not well known. Objective: To assess the incidence of atrial tachycardia/fibrillation post-PVAI as detected by a PPM and whether these recurrences correlate to symptomatic recurrence. Methods: Eighty-six consecutive patients with symptomatic AF and PPMs with programmable mode-switch capability underwent PVAI. Mode switching was programmed post-PVAI to occur at an atrial-sensed rate of >170 bpm. Patients were followed with clinic visits, ECG, and PPM interrogation at 1, 3, 6, and 9 months post-PVAI. The number and duration of mode-switching episodes (MSEs) were recorded at each visit and is presented as median (interquartile range). Results: The patients (age 57 ± 8 years, EF 54 ± 10%) had paroxysmal (65%) and persistent (35%) AF pre-PVAI. Sensing, pacing, and lead function were normal for all PPMs at follow-up. Of the 86 patients, 20 (23%) had AF recurrence based on symptoms. All 20 of these patients had appropriate MSEs detected. Of the 66 patients without symptomatic recurrence, 21 (32%) had MSEs detected. In 19 of these patients, MSEs were few in number, compared with patients with symptomatic recurrence (16 [4,256] vs 401 [151,2,470], P < 0.01). The durations were all <60 seconds. All of these nonsustained MSEs occurred within the first 3 months post-PVAI, gradually decreasing over time. The other 2 of 21 remaining patients had numerous (1,343 [857,1,390]) and sustained (18 ± 12 minutes) MSEs that also persisted beyond 3 months (1 beyond 6 months). Therefore, the incidence of numerous, sustained MSEs in asymptomatic patients post-PVAI was 2 of 66 (3%). Conclusions: Detection of atrial tachyarrhythmias by a PPM occurred in 30% of patients without symptomatic AF recurrence. Most of these episodes were <60 seconds and waned within 3 months. Sustained, asymptomatic episodes were uncommon. [source]


Clinical Implications of Reconnection Between the Left Atrium and Isolated Pulmonary Veins Provoked by Adenosine Triphosphate after Extensive Encircling Pulmonary Vein Isolation

JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, Issue 4 2007
HITOSHI HACHIYA M.D.
Introduction: Dormant pulmonary vein (PV) conduction can be provoked by adenosine triphosphate (ATP) after extensive encircling pulmonary vein isolation (EEPVI). However, the clinical implication of reconnection between the left atrium (LA) and isolated PVs provoked by ATP (ATP-reconnection) remains unknown. Methods and Results: We studied the clinical consequences of ATP-reconnection during intravenous isoproterenol infusion (ISP-infusion). EEPVI severs conduction between the LA and ipsilateral PVs at their junction. Radiofrequency energy is applied at a distance from the PV ostia guided by double Lasso catheters placed within the ipsilateral superior and inferior PVs. This study comprised 82 patients (67 men, 56 ± 9 years old) with atrial fibrillation (AF) who underwent injection of ATP during ISP infusion after successful EEPVI (ATP(+) group). We compared clinical characteristics of 170 patients who underwent earlier EEPVI prior to our use of ATP injection after successful EEPVI (ATP(N/D) group) with those of ATP(+) group patients who underwent one session of EEPVI. ATP-reconnection occurred in 34 (41%) of 82 ATP(+) group patients. Additional radiofrequency applications were performed to eliminate ATP-reconnection in all ipsilateral PVs. Continuous ATP-reconnection of more than 20 seconds duration occurred in six (7.3%) of 82 patients. A total of 102 (60%) of 170 patients in the ATP(N/D) group had no recurrence of AF, whereas 60 (73%) of 82 ATP(+) group patients who underwent only one EEPVI session have had no recurrence of AF in a 6.1 ± 3.3-month follow-up period (P = 0.04). Conclusion: Radiofrequency application for provoked ATP-reconnection may reduce clinical AF recurrence. [source]


Ablation of Focally Induced Atrial Fibrillation:

JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, Issue 2 2004
Selective or Extensive?
Introduction: Focally induced atrial fibrillation (AF) often is due to ectopic activity in the pulmonary veins (PV). Although initial approaches were aimed at ablating only the ectopic foci, more extensive ablation approaches have evolved that isolate all PVs empirically and/or create circumferential ablation lines in the left atrium (LA). These techniques last longer and may be associated with more risks. We retrospectively evaluated the outcome and risks of ablation for focally induced AF in a single-center patient population. Methods and Results: We report on 47 patients (32 men and 15 women; age 47 ± 10 years) in whom 52 ablations were performed. In 19 patients (22 sessions), ablation was directed at the site(s) of overt ectopic activity ("selective" group), whereas in 28 patients (30 sessions) without sufficient ectopy to determine the culprit PV a mean of 3.5 PVs were empirically targeted for bidirectional disconnection from the LA ("extensive" group). On a preprocedural Holter recording, the "selective" group had significantly more isolated atrial ectopy (3,276 ± 2,933 vs 620 ± 937 beats/24 hours) and runs of atrial tachycardia (330 ± 202 vs 53 ± 87 runs/24 hours) than the "extensive" group (P < 0.01 for both). Only 11% had persistent AF before ablation. Acute procedural success was 81% (elimination of all ectopy) and 83%, respectively (bidirectional and fully circumferential isolation of all targeted PVs). Procedure and fluoroscopy times were significantly shorter in the "selective" group. There were no major complications, but 7 minor complications and 2 acute PV stenoses > 50% in the 30 "extensive" procedures were observed. Mean follow-up was 8.4 ± 8.5 months (median 6.9). Kaplan-Meier analysis, excluding recurrences during only the first month ("delayed cure"), showed AF recurrence in 45% after 6 months and in 55% after 1 year. Outcome was not dependent on ablation approach ("selective" or "extensive") nor was time to first AF (22 ± 64 days and 30 ± 69 days). AF recurrence tended to be higher in patients with larger LA (P = 0.08), underlying heart disease or hypertension (P = 0.08), and those "extensive" patients in whom not all 4 PVs were targeted (P = 0.07). Conclusion: Trigger-directed ablation for focally induced AF is associated with a relatively high recurrence rate during follow-up. Apart from recurrence of the ectopic trigger, this may point to underlying structural changes in the atrial substrate not addressed by the ablation. Prospective evaluation of the risk-to-benefit profile of any technique (selective, extensive, including linear lines) is required. (J Cardiovasc Electrophysiol, Vol. 15, pp. 200-205, February 2004) [source]


Sinus Pacemaker Function after Cardioversion of Chronic Atrial Fibrillation: Is Sinus Node Remodeling Related with Recurrence?

JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, Issue 7 2001
EMMANUEL G. MANIOS M.D.
Sinus Node Remodeling and Atrial Fibrillation. Introduction: The objective of this study was to investigate the temporal changes in sinus node function in postcardioversion chronic atrial fibrillation (AF) patients and their possible relation with the recurrence rates of AF. Methods and Results: In 37 chronic AF patients, internally cardioverted to sinus rhythm, corrected sinus node recovery time (CSNRT), and the pattern of corrected return cycle lengths were assessed 5 to 20 minutes and 24 hours after conversion. The last 20 consecutive patients also were evaluated after autonomic blockade. Twenty subjects with normal atrial structure and no history of AF served as the control group. Patients were followed-up for 1 month for recurrence, and the density of supraventricular ectopic beats per hour was obtained during the first 24 hours after conversion. Fifteen patients (40.5%) relapsed during follow-up. CSNRT values at 600 msec (371 ± 182 msec) and 500 ms (445 ± 338 msec) were significantly higher than those of control subjects (278 ± 157 msec, P = 0.050, and 279 ± 130 msec, P = 0.037, respectively). Significant temporal changes in CSNRT also were observed during the first 24 hours after conversion (600 msec: 308 ± 120 msec, P = 0.034; 500 msec: 340 ± 208 msec, P = 0.017). No significant interaction and temporal effects were observed with regard to corrected return cycle length pattern. Similar data regarding CSNRT and corrected return cycle length pattern were obtained after autonomic blockade. Patients with abnormal CSNRT after cardioversion had higher recurrence rates (50%) than those with normal function (37%; P = NS). Patients who relapsed had a higher density of supraventricular ectopic beats per hour (159 ± 120) compared with those who did not (35 ± 37; P = 0.001). Conclusion: Depressed sinus node function is observed after conversion of chronic AF. Recovery from this abnormality and its independence from autonomic function suggest that AF remodels the sinus node. Our data do not support a causative role of sinus node function in AF recurrence, but they do indicate such a role for the density of atrial ectopic beats. [source]


Left Atrial Ablation at the Anatomic Areas of Ganglionated Plexi for Paroxysmal Atrial Fibrillation

PACING AND CLINICAL ELECTROPHYSIOLOGY, Issue 10 2010
EVGENY POKUSHALOV M.D., Ph.D.
Background:,Modification of left atrial ganglionated plexi (GP) is a promising technique for the treatment of paroxysmal atrial fibrillation (AF) but its therapeutic efficacy is not established. This study aimed at evaluating the effectiveness of anatomic GP modification by means of an implantable arrhythmia monitoring device. Methods:,In 56 patients with paroxysmal AF, radiofrequency ablation at anatomic sites, where the main clusters of GP have been identified in the left atrium, was performed. In all patients, an electrocardiogram monitor (Reveal XT, Medtronic Inc., Minneapolis, MN, USA) was implanted before (n = 7) or immediately after (n = 49) AF ablation. Results:,Average duration of the procedure was 142 ± 18 min and average fluoroscopy time 20 ± 7 min. In total, 53,81 applications of RF energy were delivered (mean of 18.2 ± 3.8 at each of the four areas of GP ablation). Heart rate variability was assessed in 31 patients. Standard deviation of RR intervals over the entire analyzed period, the root mean square of differences between successive RR intervals, and high frequencies decreased, while HRmin, HRmean, and LF to HF ratio increased immediately postablation; these values returned to baseline 6 months after the procedure. At end of 12-month follow-up, 40 (71%) patients were free of arrhythmia recurrence. Ten patients had AF recurrence, two patients had left atrial flutter, and four patients had episodes of flutter as well as AF recurrence. Duration of episodes of AF after ablation gradually decreased over the follow-up period. Conclusions:,Regional ablation at the anatomic sites of the left atrial GP can be safely performed and enables maintenance of sinus rhythm in 71% of patients with paroxysmal AF for a 12-month period. (PACE 2010; 33:1231,1238) [source]


Predictive Capability of Left Atrial Size Measured by CT, TEE, and TTE for Recurrence of Atrial Fibrillation Following Radiofrequency Catheter Ablation

PACING AND CLINICAL ELECTROPHYSIOLOGY, Issue 5 2010
SACHIN S. PARIKH M.D.
Background: Recurrence of atrial fibrillation (AF) after radiofrequency catheter ablation (RFCA) has been well established and is in part related to left atrial (LA) size. The purpose of this study was to assess the predictive capability of LA diameter (LAD) and LA volume (LAV) by echocardiography and computed tomography (CT) to determine success in patients undergoing RFCA of AF. Methods: Eighty-eight patients with paroxysmal or persistent AF who had undergone RFCA and had a prior transthoracic echocardiogram (TTE), transesophageal echocardiogram (TEE), and CT were enrolled in the study. TTE LADs and LV ejection fraction as well as TEE LADs and LAVs in three views were recorded. CT LAVs were also recorded. Clinical parameters prior to ablation as well as at 1-year follow-up were assessed. Results: A total of 40 (45%) patients with paroxysmal AF and 48 (55%) patients with persistent AF were analyzed. Paroxysmal AF patients had a RFCA success rate of 88% at 1 year with persistent AF patients having a 52% success rate (P < 0.001). A CT-derived LAV , 117 cc was associated with an odds ratio (OR) for recurrence of 4.8 (95% confidence interval [CI]=[1.4,16.4], P = 0.01) while a LAV ,130 cc was associated with an OR for recurrence of 22.0 (95% CI =[2.5,191.0], P = 0.005) after adjustment for persistent AF. Conclusions: LA dimensions and AF type are highly predictive of AF recurrence following RFCA. LAV by CT has significant predictive benefit over standard LADs in severely enlarged atria even after adjustment for AF type. (PACE 2010; 532,540) [source]


Usefulness of the Adenosine Triphosphate with a Sufficient Observation Period for Detecting Reconduction after Pulmonary Vein Isolation

PACING AND CLINICAL ELECTROPHYSIOLOGY, Issue 10 2009
YUICHI NINOMIYA M.D.
Background: Although reconduction after pulmonary vein (PV) isolation is considered to play a key role in the recurrence of paroxysmal atrial fibrillation (AF), there have been few reports regarding the precise time course of early reconduction. Several studies have suggested that transient PV reconduction facilitated by adenosine may predict long-term AF recurrence. This study was designed to clarify the incidence and time course of early reconduction after PVI during the procedure and to confirm whether the use of ATP after a certain observation period was useful to detect early reconduction after PVI. Methods: In 21 patients (18 males, 56 ± 11 years) with drug refractory AF, radiofrequency circumferential PV antrum ablation was performed in all 4 PVs. After the completion of isolation, electrograms in each PV were repeatedly recorded (1.98 ± 0.57 times per PV) using a circular mapping catheter for an observation period of 87 ± 29 minutes. After isolation of all 4 PVs, 30 mg of adenosine triphosphate (ATP) was administered during isoproterenol infusion. Results: PV electrical isolation was initially achieved in all 81 PVs. During the observation period, 12 (15%) PVs in 10 (48%) of 21 patients exhibited spontaneous reconduction. Among the remaining 69 PVs, 8 (12%) additional PVs had reconduction with the use of ATP. All PV reconduction was successfully eliminated by 4.5 ± 2.2 additional radiofrequency applications. Conclusion: A sufficient observation period and the use of ATP are useful to detect early reconduction after PV isolation. [source]


Segmental Pulmonary Vein Ablation: Success Rates with and without Exclusion of Areas Adjacent to the Esophagus

PACING AND CLINICAL ELECTROPHYSIOLOGY, Issue 6 2008
KLAUS KETTERING M.D.
Background: Catheter ablation has become the first line of therapy in patients with symptomatic recurrent, drug-refractory atrial fibrillation (AF). The occurrence of an atrioesophageal fistula is a rare but serious complication after AF-ablation procedures. This risk is even present during segmental pulmonary vein (PV) ablation procedures because the esophagus does frequently have a very close anatomical relationship to the right or left PV ostia. The aim of the present study was to analyze whether the exclusion of areas adjacent to the esophagus does have a significant effect on the success rates after segmental pulmonary vein ablation procedures. Methods: Forty-three consecutive patients with symptomatic paroxysmal AF were enrolled in this study. In all patients, a segmental PV ablation procedure was performed. The procedures were facilitated by a 3D real-time visualization of the circumferential mapping catheter placed in the pulmonary veins using the NavXÔ system (St. Jude Medical, St. Paul, MN, USA; open irrigated tip ablation catheter; 43°C; 30 W). In 21 patients, a complete ostial PV isolation was attempted regardless of the anatomical relationship between the ablation sites and the esophagus (group A). In the remaining 22 patients, the esophagus was marked by a stomach tube and areas adjacent to the esophagus were excluded from the ablation procedure (group B). After discharge, patients were scheduled for repeated visits at the arrhythmia clinic at 1, 3, and 6 months after the ablation procedure. Results: The segmental pulmonary vein ablation procedure could be performed as planned in all patients. In group A, all pulmonary veins could be isolated successfully in 14 out of 21 patients (67%). A mean number of 3.7 pulmonary veins (SD ± 0.5 PVs) were isolated per patient. The main reasons for an incomplete PV isolation were: small diameter of the PVs, side branches close to the ostium, or poorly accessible PV ostia. In group B, all PVs could be isolated successfully in only 12 out of 22 patients (55%; P = 0.54). A mean number of 3.2 PVs (SD ± 0.9 PVs) were isolated per patient (P = 0.05). This was mostly due to a close anatomical relationship to the esophagus. The ablation strategy had to be modified in 16/22 patients in group B because of a close anatomical relationship between the left (n = 10) or right (n = 6) PV ostia and the esophagus. After 3 months, the percentage of patients free from an AF recurrence was not significantly different between the two groups (90% vs 95%; P = 0.61). After 6 months, there was no significant difference between the success rates either (81% vs 82%; P = 1.0). There were no major complications in both groups. Conclusions: The exclusion of areas adjacent to the esophagus results in a moderately higher percentage of incompletely isolated PVs. However, it does not have a significant effect on the AF recurrence rate during short-term and mid-term follow-up. [source]


Catheter Ablation of Chronic Atrial Fibrillation with Noncontact Mapping:

PACING AND CLINICAL ELECTROPHYSIOLOGY, Issue 2p1 2003
Are Continuous Linear Lesions Associated with Ablation Success?
SEIDL, K., et al.: Catheter Ablation of Chronic Atrial Fibrillation with Noncontact Mapping: Are Continuous Linear Lesions Associated with Ablation Success?Catheter-based, right and left atrial compartmentalization procedure was evaluated using a noncontact mapping (NCM) system. Its usefulness to identify and close discontinuities in linear lesions in both atria was evaluated. The impact of linear lesion continuity on ablation success of chronic AF was also investigated. Nineteen patients with symptomatic, drug refractory chronic AF were studied. Right atrial ablation with three predefined lines was attempted in all patients. In 18 patients, left atrial ablation was performed with four linear lesions. During a follow-up of 12 ± 3 months, 6 of 19 patients remained in sinus rhythm (SR) without antiarrhythmic agents (AAs). In addition, four patients were maintained in SR with AA. Thirteen of 14 patients with gaps identified during off-line analysis had recurrence of AF. Only one patient with a gap was free of recurrence without AAs. In the remaining five patients without recurrence of AF, no gap was observed during off-line analysis. In all four patients who were free of AF with additional treatment of AAs, two gaps had been identified. In the remaining nine patients with chronic AF recurrence, a mean of 4.9 gaps were identified. Excluding the initial learning period (first five patients) the success rate increased to 43% (6/14 patients) without and to 71% (10/14 patients) with AA. NCM identifies discontinuities in lines of ablation. Successful ablation of chronic AF is associated with continuity of linear lesions and good clinical technique demands a vigilant search for and closure of every gap. (PACE 2003; 26[Pt. I]:534,543) [source]


P Wave Duration and Morphology Predict Atrial Fibrillation Recurrence in Patients with Sinus Node Dysfunction and Atrial-Based Pacemaker

PACING AND CLINICAL ELECTROPHYSIOLOGY, Issue 11 2002
ANTONIO DE SISTI
DE SISTI, A., et al.: P Wave Duration and Morphology Predict Atrial Fibrillation Recurrence in Patients with Sinus Node Dysfunction and Atrial-Based Pacemaker. P wave duration and morphology have never been systematically evaluated as markers of AF in patients with a conventional indication to pacing. This study correlated sinus P wave duration and morphology and the incidence of AF in patients with sinus node dysfunction (SND), previous history of AF before implant, and atrial-based pacemaker. Included were 140 patients (86 men, 54 women; mean age 71.8 ± 10.4 years) with recurrent paroxysmal AF and who received a DDD (128 patients) or AAI (12 patients) pacemaker for SND. Forty-nine patients had structural heart disease. Sinus P wave duration and morphology was evaluated in leads II, III. Twenty-two patients had an abnormal P wave morphology, diphasic (+/-) in 5 and notched (+/+) in 17. The basic pacemaker rate was programmed between 60 and 70 beats/min. Rate responsive function was activated in 65 patients. During a follow-up of 27.6 ± 17.8 months, AF was documented in 87 patients. Forty-four patients developed permanent AF, following at least one episode of paroxysmal AF in 26 cases. Statistical analysis used Cox model regression. Univariate predictors of AF (P < 0.10) were drugs (mean: 2 ± 1.4) and DC shock before pacing (16/140 patients), P wave duration (mean 112.5 ± 24.6 ms), basic pacemaker rate (mean 68 ± 5 beats/min), and drugs in the follow-up (mean 1.2 ± 0.94). Multivariate analysis showed that P wave duration (b = 0.013, s.e. = 0.004; P = 0.003), and drugs before pacing (b = 0.2; s.e.= 0.08; P < 0.01) resulted in a significant independent predictor of AF. Actuarial incidence of patients free of AF at 30 months was 35%: 56% in patients with a P wave < 120 ms, and 13% in those with P wave , 120 ms (P < 0.01 by Score test). Univariate predictors of permanent AF were drugs and DC shock before pacing, left atrial size (mean 39 ± 6 mm), P wave duration, abnormal P wave morphology (22/140 patients), and drugs in the follow-up. Multivariate analysis showed that P wave morphology was the most important predictor of permanent AF (b = - 0.56, s.e.= 0.2; P = 0.008). Incidence of patients free of permanent AF at 30 months was 69%: 74% in patients with normal P wave, compared to 28% in the case of abnormal P wave morphology (P < 0.01). P wave duration and morphology are good markers of postpacing AF recurrence in patients with SND and an atrial-based pacemaker. This observation suggests that intra- and interatrial conduction disturbances be extensively evaluated before implantation, and the indication for atrial resynchronization procedures be reevaluated. [source]


P Wave Dispersion Predicts Recurrence of Paroxysmal Atrial Fibrillation in Patients with Atrioventricular Nodal Reentrant Tachycardia Treated with Radiofrequency Catheter Ablation

ANNALS OF NONINVASIVE ELECTROCARDIOLOGY, Issue 3 2006
Basri Amasyali M.D.
Background: Paroxysmal atrial fibrillation (AF) recurs in up to one-third of patients with atrioventricular nodal reentrant tachycardia (AVNRT) treated with slow pathway ablation. Therefore, identification of patients at risk for recurrence of AF after slow pathway ablation is important because of the necessity for additional therapies. The purpose of this study was to determine whether successful slow pathway ablation influences P wave parameters and whether these parameters predict the recurrence of paroxysmal AF in patients with both AVNRT and paroxysmal AF after ablation. Methods: Thirty-six patients with AVNRT and documented paroxysmal AF (Group 1) were compared to 36 age-matched controls with AVNRT only (Group 2). P wave durations and P dispersion were measured before and after ablation. Results: No significant differences were observed between P wave parameters observed before and after ablation. Maximum P wave durations (Pmax) and P dispersion (Pdisp) were significantly higher in Group 1 than in Group 2 (P < 0.001 for both) whereas minimum P wave durations did not differ between groups, both before and after ablation. Ten patients (28%) in Group-1 had recurrence of AF during a mean follow-up of 34 ± 11 months. Univariate predictors of AF recurrence were Pdisp ,35.5 ms (P < 0.010), left atrial diameter >40 mm (P < 0.010), mitral or aortic calcification (P < 0.010), Pmax ,112 ms (P < 0.050), valvular heart disease (P < 0.050), and atrial vulnerability (induction of AF lasting >30 second) after ablation (P < 0.050). However, only Pdisp ,35.5 ms (P < 0.050) and left atrial diameter >40 mm (P < 0.010) were independent predictors of AF recurrences. Conclusion: This study suggests that P wave dispersion could identify patients with AVNRT susceptible to recurrence of AF after slow pathway ablation. [source]


Dronedarone: Current Evidence and Future Questions

CARDIOVASCULAR THERAPEUTICS, Issue 1 2010
Jeremy A. Schafer
Atrial fibrillation (AF) is the most common sustained arrhythmia, affecting more than 2.2 million Americans. ACC/AHA/ESC guidelines for the management of patients with AF recommend amiodarone for maintaining sinus rhythm. Dronedarone is a derivative of amiodarone indicated for the treatment of AF. To provide an overview of dronedarone with a focus on the phase III trials and discuss unresolved questions of dronedarone. A literature search was conducted via the PubMed database using the keyword "dronedarone." Search was limited to human trials in english. The FDA website was searched for briefing documents and subcommittee meetings on dronedarone. Clinicaltrials.gov was searched with the keyword dronedarone for upcoming or unpublished clinical trials. Five phase III trials are available for dronedarone: ANDROMEDA, EURIDIS/ADONIS, ATHENA, ERATO, and DIONYSIS. EURIDIS/ADONIS and ATHENA demonstrated a reduction AF recurrence with dronedarone compared to placebo. The ANDROMEDA trial recruited patients with recent hospitalization for heart failure and was terminated due to an excess of deaths in the dronedarone group. The DIONYSIS trial was a comparative effectiveness trial that demonstrated less efficacy for dronedarone but improved tolerability compared to amiodarone. Dronedarone represents an option in the management of AF in select patients. Dronedarone is not appropriate in patients with recently decompensated heart failure or those treated with strong CYP3A4 inhibitors or medications prolonging the QT interval. Dronedarone appears to have improved tolerability at the expense of decreased efficacy when compared to amiodarone. Questions remain on the long-term safety, use in patients with heart failure, retreatment after dronedarone or amiodarone failure, and comparative efficacy with a rate control strategy. [source]


The Long-Term Risk of Stroke in Patients with Acute Myocardial Infarction Complicated with New-Onset Atrial Fibrillation

CLINICAL CARDIOLOGY, Issue 8 2009
Asanin R. Milika MD
Background The long-term risk of stroke after acute myocardial infarction (AMI) complicated with new-onset atrial fibrillation (AF) remains unclear. The aim of this study was to determine the long-term risk of AF and stroke in patients with AMI complicated with new-onset AF. Methods Patients with AMI complicated with new-onset AF (n = 260) and those without new-onset AF (n = 292) were followed for a mean of 7 years. All patients had sinus rhythm at hospital discharge. Results During the follow-up, AMI patients with new-onset AF had more frequent AF than those without new-onset AF (10.4% vs 2.7%, respectively; P < 0.0001). New-onset AF during AMI was a significant predictor of subsequent AF occurrence (the time elapsing between 2 consecutive R waves [RR] = 3.15, P = 0.004); but AF recurrence in follow-up (RR = 5.08, P = 0.001) and non-anticoagulation at discharge (RR = 0.29, P = 0.008) were independent predictors of stroke (Cox regression analysis). A period of 3.5 hours of AF within the first 48 hours of AMI was the high sensitivity cut-off level for the prediction of low long-term risk of stroke obtained by receiver operating characteristic analysis. Among patients who did not receive anticoagulants at discharge, the patients with short AF did not experience stroke and AF recurrence during follow-up, while those in the other group developed it (10.8%, P = 0.038 and 13.5%, P = 0.019, respectively). Conclusion New-onset AF during AMI identifies the patients at long-term risk for stroke who may potentially benefit from anticoagulant therapy. Atrial fibrillation recurrence in follow-up was independently related to the development of stroke. However, for low-risk patients with AF (those with short AF occurring early in AMI) long-term anticoagulants might not be required. Copyright © 2009 Wiley Periodicals, Inc. [source]


Persistence of Pulmonary Vein Isolation After Robotic Remote-Navigated Ablation for Atrial Fibrillation and its Relation to Clinical Outcome

JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, Issue 10 2010
STEPHAN WILLEMS M.D.
Robotic Remote Ablation for AF. Aims: A robotic navigation system (RNS, HansenÔ) has been developed as an alternative method of performing ablation for atrial fibrillation (AF). Despite the growing application of RNS-guided pulmonary vein isolation (PVI), its consequences and mechanisms of subsequent AF recurrences are unknown. We investigated the acute procedural success and persistence of PVI over time after robotic PVI and its relation to clinical outcome. Methods and Results: Sixty-four patients (60.7 ± 9.8 years, 53 male) with paroxysmal AF underwent robotic circumferential PVI with 3-dimensional left atrial reconstruction (NavXÔ). A voluntary repeat invasive electrophysiological study was performed 3 months after ablation irrespective of clinical course. Robotic PVI was successful in all patients without complication (fluoroscopy time: 23.5 [12,34], procedure time: 180 [150,225] minutes). Fluoroscopy time demonstrated a gradual decline but was significantly reduced after the 30th patient following the introduction of additional navigation software (34 [29,45] vs 12 [9,17] minutes; P < 0.001). A repeat study at 3 months was performed in 63% of patients and revealed electrical conduction recovery in 43% of all PVs. Restudied patients without AF recurrence (n = 28) showed a significantly lower number of recovered PVs (1 (0,2) vs 2 (2,3); P = 0.006) and a longer LA-PV conduction delay than patients with AF recurrences (n = 12). Persistent block of all PVs was associated with freedom from AF in all patients. At 3 months, 67% of patients were free of AF, while reablation of recovered PVs led to an overall freedom from AF in 81% of patients after 1 year. Conclusion: Robotic PVI for PAF is safe, effective, and requires limited fluoroscopy while yielding comparable success rates to conventional ablation approaches with PV reconduction as a common phenomenon associated with AF recurrences. (J Cardiovasc Electrophysiol, Vol. 21, pp. 1079-1084) [source]


Prevalence, Predictors, and Prognosis of Atrial Fibrillation Early After Pulmonary Vein Isolation: Findings from 3 Months of Continuous Automatic ECG Loop Recordings

JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, Issue 10 2009
SANDEEP JOSHI M.D.
Introduction: Following pulmonary vein isolation (PVI) for atrial fibrillation (AF), early recurrences are frequent, benign and classified as a part of a "blanking period." This study characterizes early recurrences and determines implications of early AF following PVI. Methods and Results: Seventy-two consecutive patients (59.8 ± 10.7 years, 69% male) were studied following PVI for paroxysmal or persistent AF. Subjects were fitted with an external loop recorder for automatic, continuous detection of AF recurrence for 3 months. AF prevalence was highest 2 weeks after PVI (54%) and declined to an eventual low of 22%. A significant number (488, 34%) of recurrences were asymptomatic; however, all patients with ,1 AF event had ,1 symptomatic event. No clear predictor of early recurrence was identified. Forty-seven (65%) patients had at least 1 AF episode, predominantly (39 of 47 patients, 83%) within 2 weeks of PVI. Of the 33 patients who did not experience AF within the first 2 weeks, 85% (28/33) were complete responders (P = 0.03) at 12 months. Recurrence at any time within 3 months was not associated with procedural success or failure. Conclusions: Early AF recurrence peaks within the first few weeks after PVI, but continues at a lower level until the completion of monitoring. A blanking period of 3 months is justified to identify patients with AF recurrences that do not portend procedure failure. Freedom from AF in the first 2 weeks following ablation significantly predicts long-term AF freedom. [source]


Value of Different Follow-Up Strategies to Assess the Efficacy of Circumferential Pulmonary Vein Ablation for the Curative Treatment of Atrial Fibrillation

JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, Issue 12 2005
CHRISTOPHER PIORKOWSKI M.D.
Background: The objective of this study was to compare transtelephonic ECG every 2 days and serial 7-day Holter as two methods of follow-up after atrial fibrillation (AF) catheter ablation for the judgment of ablation success. Patients with highly symptomatic AF are increasingly treated with catheter ablation. Several methods of follow-up have been described, and judgment on ablation success often relies on patients' symptoms. However, the optimal follow-up strategy objectively detecting most of the AF recurrences is yet unclear. Methods: Thirty patients with highly symptomatic AF were selected for circumferential pulmonary vein ablation. During follow-up, a transtelephonic ECG was transmitted once every 2 days for half a year. Additionally, a 7-day Holter was recorded preablation, after ablation, after 3 and 6 months, respectively. With both, procedures symptoms and actual rhythm were correlated thoroughly. Results: A total of 2,600 transtelephonic ECGs were collected with 216 of them showing AF. 25% of those episodes were asymptomatic. On a Kaplan-Meier analysis 45% of the patients with paroxysmal AF were still in continuous SR after 6 months. Simulating a follow-up based on symptomatic recurrences only, that number would have increased to 70%. Using serial 7-day ECG, 113 Holter with over 18,900 hours of ECG recording were acquired. After 6 months the percentage of patients classified as free from AF was 50%. Of the patients with recurrences, 30,40% were completely asymptomatic. The percentage of asymptomatic AF episodes stepwise increased from 11% prior ablation to 53% 6 months after. Conclusions: The success rate in terms of freedom from AF was 70% on a symptom-only-based follow-up; using serial 7-day Holter it decreased to 50% and on transtelephonic monitoring to 45%, respectively. Transtelephonic ECG and serial 7-day Holter were equally effective to objectively determine long-term success and to detect asymptomatic patients. [source]


Feasibility of Pulmonary Vein Ostia Radiofrequency Ablation in Patients with Atrial Fibrillation: A Multicenter Study (CACAF Pilot Study)

PACING AND CLINICAL ELECTROPHYSIOLOGY, Issue 1p2 2003
GIUSEPPE STABILE
STABILE, G., et al.: Feasibility of Pulmonary Vein Ostia Radiofrequency Ablation in Patients with Atrial Fibrillation: A Multicenter Study (CACAF Pilot Study)Radiofrequency (RF) catheter ablation has been proposed as a treatment of atrial fibrillation (AF). Several approaches have been reported and success rates have been dependent on procedural volume and operator's experience. This is the first report of a multicenter study of RF ablation of AF. We treated 44 men and 25 women with paroxysmal(n = 40)or persistent(n = 29), drug refractory AF. Circular pulmonary vein (PV) ostial lesions were deployed transseptally, during sinus rhythm(n = 42)or AF(n = 26), under three-dimensional electroanatomic guidance. Cavo-tricuspid isthmus ablation was performed in 27 (40%) patients. The mean procedure time was215 ± 76minutes (93,530), mean fluoroscopic exposure32 ± 14minutes (12,79), and mean number of RF pulses per patient56 ± 29(18,166). The mean numbers of separate PV ostia mapped and isolated per patient were3.9 ± 0.5, and3.8 ± 0.7, respectively. Major complications were observed in 3 (4%) patients, including pericardial effusion, transient ischemic attack, and tamponade. At 1-month follow-up, 21 of 68 (31%) patients had had AF recurrences, of whom 8 required electrical cardioversion. After the first month, over a mean period of9 ± 3(5,14) months, 57 (84%) patients remained free of atrial arrhythmias. RF ablation of AF by circumferential PV ostial ablation is feasible with a high short-term success rate. While the procedure and fluoroscopic exposure duration were short, the incidence of major cardiac complications was not negligible. (PACE 2003; 26[Pt. II]:284,287) [source]


P Wave Dispersion Predicts Recurrence of Paroxysmal Atrial Fibrillation in Patients with Atrioventricular Nodal Reentrant Tachycardia Treated with Radiofrequency Catheter Ablation

ANNALS OF NONINVASIVE ELECTROCARDIOLOGY, Issue 3 2006
Basri Amasyali M.D.
Background: Paroxysmal atrial fibrillation (AF) recurs in up to one-third of patients with atrioventricular nodal reentrant tachycardia (AVNRT) treated with slow pathway ablation. Therefore, identification of patients at risk for recurrence of AF after slow pathway ablation is important because of the necessity for additional therapies. The purpose of this study was to determine whether successful slow pathway ablation influences P wave parameters and whether these parameters predict the recurrence of paroxysmal AF in patients with both AVNRT and paroxysmal AF after ablation. Methods: Thirty-six patients with AVNRT and documented paroxysmal AF (Group 1) were compared to 36 age-matched controls with AVNRT only (Group 2). P wave durations and P dispersion were measured before and after ablation. Results: No significant differences were observed between P wave parameters observed before and after ablation. Maximum P wave durations (Pmax) and P dispersion (Pdisp) were significantly higher in Group 1 than in Group 2 (P < 0.001 for both) whereas minimum P wave durations did not differ between groups, both before and after ablation. Ten patients (28%) in Group-1 had recurrence of AF during a mean follow-up of 34 ± 11 months. Univariate predictors of AF recurrence were Pdisp ,35.5 ms (P < 0.010), left atrial diameter >40 mm (P < 0.010), mitral or aortic calcification (P < 0.010), Pmax ,112 ms (P < 0.050), valvular heart disease (P < 0.050), and atrial vulnerability (induction of AF lasting >30 second) after ablation (P < 0.050). However, only Pdisp ,35.5 ms (P < 0.050) and left atrial diameter >40 mm (P < 0.010) were independent predictors of AF recurrences. Conclusion: This study suggests that P wave dispersion could identify patients with AVNRT susceptible to recurrence of AF after slow pathway ablation. [source]