Home About us Contact | |||
AF Episodes (af + episode)
Selected AbstractsPrevalence, Predictors, and Prognosis of Atrial Fibrillation Early After Pulmonary Vein Isolation: Findings from 3 Months of Continuous Automatic ECG Loop RecordingsJOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, Issue 10 2009SANDEEP JOSHI M.D. Introduction: Following pulmonary vein isolation (PVI) for atrial fibrillation (AF), early recurrences are frequent, benign and classified as a part of a "blanking period." This study characterizes early recurrences and determines implications of early AF following PVI. Methods and Results: Seventy-two consecutive patients (59.8 ± 10.7 years, 69% male) were studied following PVI for paroxysmal or persistent AF. Subjects were fitted with an external loop recorder for automatic, continuous detection of AF recurrence for 3 months. AF prevalence was highest 2 weeks after PVI (54%) and declined to an eventual low of 22%. A significant number (488, 34%) of recurrences were asymptomatic; however, all patients with ,1 AF event had ,1 symptomatic event. No clear predictor of early recurrence was identified. Forty-seven (65%) patients had at least 1 AF episode, predominantly (39 of 47 patients, 83%) within 2 weeks of PVI. Of the 33 patients who did not experience AF within the first 2 weeks, 85% (28/33) were complete responders (P = 0.03) at 12 months. Recurrence at any time within 3 months was not associated with procedural success or failure. Conclusions: Early AF recurrence peaks within the first few weeks after PVI, but continues at a lower level until the completion of monitoring. A blanking period of 3 months is justified to identify patients with AF recurrences that do not portend procedure failure. Freedom from AF in the first 2 weeks following ablation significantly predicts long-term AF freedom. [source] Frequency Analysis of Atrial Electrograms Identifies Conduction Pathways from the Left to the Right Atrium During Atrial Fibrillation,Studies in Two Canine ModelsJOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, Issue 6 2009KYUNGMOO RYU Ph.D. Studies of atrial fibrillation (AF) have demonstrated that a stable rhythm of very short cycle length in the left atrium (LA) can cause fibrillatory conduction in the rest of the atria. We tested the hypothesis that fast Fourier transform (FFT) analysis of atrial electrograms (AEGs) during this AF will rapidly and reliably identify LA-to-right atrium (RA) conduction pathway(s) generated by the driver. Methods and Results: During induced atrial tachyarrhythmias in the canine sterile pericarditis and rapid ventricular pacing-induced congestive heart failure models, 380,404 AEGs were recorded simultaneously from epicardial electrodes on both atria. FFT analysis of AEGs during AF demonstrated a dominant frequency peak in the LA (driver), and multiple frequency peaks in parts of the LA and the most of the RA. Conduction pathways from the LA driver to the RA varied from study-to-study. They were identified by the presence of multiple frequency peaks with one of the frequency peaks at the same frequency as the driver, and traveled (1) inferior to the inferior vena cava (IVC); (2) between the superior vena cava and the right superior pulmonary vein (RSPV); (3) between the RSPV and the right inferior pulmonary vein (RIPV); (4) between the RIPV and the IVC; and (5) via Bachmann's bundle. Conduction pathways identified by FFT analysis corresponded to the conduction pathways found in classical sequence of activation mapping. Computation time for FFT analysis for each AF episode took less than 5 minutes. Conclusion: FFT analysis allowed rapid and reliable detection of the LA-to-RA conduction pathways in AF generated by a stable and rapid LA driver. [source] Individualized Selection of Pacing Algorithms for the Prevention of Recurrent Atrial Fibrillation: Results from the VIP RegistryPACING AND CLINICAL ELECTROPHYSIOLOGY, Issue 2 2006THORSTEN LEWALTER Objectives: The VIP registry investigated the efficacy of preventive pacing algorithm selection in reducing atrial fibrillation (AF) burden. Background: There are few data identifying which patients might benefit most from which preventive pacing algorithms. Methods: Patients, with at least one documented AF episode and a conventional antibradycardia indication for pacemaker therapy, were enrolled. They received pacemakers with AF diagnostics and four preventive algorithms (Selection and PreventAF series, Vitatron). A 3-month Diagnostic Phase with conventional pacing identified a Substrate Group (>70% of AF episodes with <2 premature atrial contractions [PACs] before AF onset) and a Trigger Group (,70% of AF episodes with <2 PACs before AF onset). This was followed by a 3-month Therapeutic Phase where in the Trigger Group algorithms were enabled aimed at avoiding or preventing a PAC and in the Substrate Group continuous atrial overdrive pacing was enabled. Results: One hundred and twenty-six patients were evaluated. In the Trigger Group (n = 73), there was a statistically significant 28% improvement in AF burden (median AF burden: 2.06 hours/day, Diagnostic Phase vs 1.49 hours/day, Therapy Phase; P = 0.03304 signed-rank test), and reduced PAC activity. There was no significant improvement in AF burden in the Substrate Group (median AF burden: 1.82 hours/day, Diagnostic Phase vs 2.38 hours/day, Therapy Phase; P = 0.12095 signed-rank test), and little change in PAC activity. Conclusions: We identified a subgroup of patients for whom the selection of appropriate pacing algorithms, based on individual diagnostic data, translated into a reduced AF burden. Trigger AF patients were more likely responders to preventive pacing algorithms as a result of PAC suppression. [source] Vagal Paroxysmal Atrial Fibrillation: Prevalence and Ablation Outcome in Patients Without Structural Heart DiseaseJOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, Issue 5 2010RAPHAEL ROSSO M.D. Prevalence of Vagal Paroxysmal Atrial Fibrillation.,Introduction: The prevalence of vagal and adrenergic atrial fibrillation (AF) and the success rate of pulmonary vein isolation (PVI) are not well defined. We investigated the prevalence of vagal and adrenergic AF and the ablation success rate of antral pulmonary vein isolation (APVI) in patients with these triggers compared with patients with random AF. Methods and Results: Two hundred and nine consecutive patients underwent APVI due to symptomatic drug refractory paroxysmal AF. Patients were diagnosed as vagal or adrenergic AF if >90% of AF episodes were related to vagal or adrenergic triggers; otherwise, a diagnosis of random AF was made. Clinical, electrocardiogram (ECG), and Holter follow-up was every 3 months in the first year and every 6 months afterward and for symptoms. Of 209 patients, 57 (27%) had vagal AF, 14 (7%) adrenergic AF, and 138 (66%) random AF. Vagal triggers were sleep (96.4%), postprandial (96.4%), late post-exercise (51%), cold stimulus (20%), coughing (7%), and swallowing (2%). At APVI, 94.3% of patients had isolation of all veins. Twenty-five (12%) patients had a second APVI. At a follow-up of 21 ± 15 months, the percentage of patients free of AF was 75% in the vagal group, 86% in the adrenergic group, and 82% for random AF (P = 0.51). Conclusion: In patients with PAF and no structural heart disease referred for APVI, vagal AF is present in approximately one quarter. APVI is equally effective in patients with vagal AF as in adrenergic and random AF. (J Cardiovasc Electrophysiol, Vol. 21, pp. 489-493, May 2010) [source] Presence and Duration of Atrial Fibrillation Detected by Continuous Monitoring: Crucial Implications for the Risk of Thromboembolic EventsJOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, Issue 3 2009GIOVANNI L. BOTTO M.D. Introduction: Asymptomatic atrial fibrillation (AF) can expose patients to the risk of stroke. The primary objective of this study was to assess the incidence of thromboembolic events in relationship with CHADS2 (congestive heart failure, hypertension, age ,75 years, diabetes mellitus, and prior stroke, or transient ischemic attack) score and AF presence/duration. The secondary objective was to compare intermittent versus continuous monitoring strategies. Methods and Results: Data from patients with an implanted pacemaker and a history of AF were analyzed. Thromboembolic risk was quantified through CHADS2 score. Three AF groups were considered: patients with <5-minutes AF on 1 day (AF-free); patients with >5-minutes AF on 1 day but <24 hours (AF-5 minutes); patients with AF episodes >24 hours (AF-24 hours). Monitoring strategies involving 24-hour Holter, 1-week Holter, and 30-day Holter were simulated. Data from 568 patients continuously monitored for 1 year were analyzed: 171 (30%) had CHADS2 score = 0; 269 (47%) had CHADS2 score = 1; 111 (20%) had CHADS2 score = 2; and 17 (3%) had CHADS2 score , 3. During follow-up, 14 patients (2.5%) had an ischemic thromboembolic event. AF-24 hours patients numbered 223 (39.2%); AF-5 minutes, 179 (31.5%); and AF-free, 29.2%. By combining AF presence/duration with CHADS2 score, two subpopulations with markedly different risks of events (0.8% vs 5%, P = 0.035) were identified, the former corresponding to AF-free with CHADS2,2, or AF-5 minutes with CHADS2,1, or AF-24 hours with CHADS2= 0. The mean sensitivity in detecting an AF episode lasting >5 minutes was 44.4%, 50.4%, and 65.1% for 24-hour Holter, 1-week Holter, and 1-month Holter monitoring, respectively. Conclusion: In patients with recurrent AF episodes, risk stratification for thromboembolic events can be improved by combining CHADS2 score with AF presence/duration. [source] Spontaneous Pulmonary Vein Firing in Man: Relationship to Tachycardia-Pause Early Afterdepolarizations and Triggered Arrhythmia in Canine Pulmonary Veins In VitroJOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, Issue 10 2007EUGENE PATTERSON Ph.D. Introduction: Rapid firing originating within pulmonary veins (PVs) initiates atrial fibrillation (AF). The following studies were performed to evaluate spontaneous PV firing in patients with AF to distinguish focal versus reentrant mechanisms. Methods: Intracardiac recordings were obtained in 18 patients demonstrating paroxysmal AF. Microelectrode (ME) recordings were obtained from superfused canine PV sleeves (N = 48). Results: Spontaneous PV firing (566 ± 16 bpm; 127 ± 6 ms cycle length) giving rise to AF (52 episodes) was observed. Tachycardia-pause initiation was present in 132 of 200 episodes of rapid PV firing and 34 of 52 AF episodes. The pause cycle length preceding PV firing was 1,039 ± 86 ms following tachycardia (420 ± 40 ms cycle length). The remaining episodes were initiated following a 702 ± 32 ms pause during sinus rhythm (588 ± 63 ms). Spontaneous firing recorded with a multipolar mapping catheter did not detect electrical activity bridging the diastolic interval between the initial ectopic and preceding post-pause sinus beat. Tachycardia-pause initiated PV firing (138 ± 7 ms coupling interval) in patients correlated with tachycardia-pause enhanced isometric force, early afterdepolarization (EAD) amplitude, and triggered firing within canine PVs. Rapid firing (1,172 ± 134 bpm; 51 ± 8 ms cycle length) following an abbreviated coupling interval (69 ± 12 ms) was initiated in 13 of 18 canine PVs following tachycardia-pause pacing during norepinephrine + acetylcholine superfusion. Stimulation selectively activating local autonomic nerve terminals facilitated tachycardia-pause triggered firing in canine PVs (5 of 15 vs 0 of 15; P < 0.05). Conclusions: The studies demonstrate (1) tachycardia-pause initiation of rapid, short-coupled PV firing in AF patients and (2) tachycardia-pause facilitation of isometric force, EAD formation, and autonomic-dependent triggered firing within canine PVs, suggestive of a common arrhythmia mechanism. [source] Atrial Fibrillation Burden During the Post-Implant Period After CRT Using Device-Based DiagnosticsJOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, Issue 8 2006BURKHARD HÜGL M.D. Aims: Cardiac resynchronization therapy (CRT) is increasingly used in congestive heart failure (CHF) patients (with cardiac dyssynchrony). In addition to delivering therapy, CRT devices offer a variety of diagnostic tools for continuous long-term monitoring of clinically relevant information (i.e., occurrence and duration of arrhythmia episodes). Methods and Results: Eighty-four patients with drug-refractory CHF in NYHA-class II,IV received a CRT device. The response to CRT was assessed by determining NYHA class at baseline and at 3 months follow-up. Atrial fibrillation (AF) burden (defined as time of AF per day) was continuously measured by the device. A significant gradual reduction of AF burden (from 9.88 ± 12.61 to 4.20 ± 9.24 [hours/day]) and number of patients experiencing AF episodes (from 26 to 13) were observed during CRT. Conclusions: (1) Diagnostic features for long-term monitoring of physiological variables provide useful information on the state and course of AF and may improve disease management. (2) AF burden reduces over time during the first 3 months after CRT implantation. [source] Value of Different Follow-Up Strategies to Assess the Efficacy of Circumferential Pulmonary Vein Ablation for the Curative Treatment of Atrial FibrillationJOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, Issue 12 2005CHRISTOPHER PIORKOWSKI M.D. Background: The objective of this study was to compare transtelephonic ECG every 2 days and serial 7-day Holter as two methods of follow-up after atrial fibrillation (AF) catheter ablation for the judgment of ablation success. Patients with highly symptomatic AF are increasingly treated with catheter ablation. Several methods of follow-up have been described, and judgment on ablation success often relies on patients' symptoms. However, the optimal follow-up strategy objectively detecting most of the AF recurrences is yet unclear. Methods: Thirty patients with highly symptomatic AF were selected for circumferential pulmonary vein ablation. During follow-up, a transtelephonic ECG was transmitted once every 2 days for half a year. Additionally, a 7-day Holter was recorded preablation, after ablation, after 3 and 6 months, respectively. With both, procedures symptoms and actual rhythm were correlated thoroughly. Results: A total of 2,600 transtelephonic ECGs were collected with 216 of them showing AF. 25% of those episodes were asymptomatic. On a Kaplan-Meier analysis 45% of the patients with paroxysmal AF were still in continuous SR after 6 months. Simulating a follow-up based on symptomatic recurrences only, that number would have increased to 70%. Using serial 7-day ECG, 113 Holter with over 18,900 hours of ECG recording were acquired. After 6 months the percentage of patients classified as free from AF was 50%. Of the patients with recurrences, 30,40% were completely asymptomatic. The percentage of asymptomatic AF episodes stepwise increased from 11% prior ablation to 53% 6 months after. Conclusions: The success rate in terms of freedom from AF was 70% on a symptom-only-based follow-up; using serial 7-day Holter it decreased to 50% and on transtelephonic monitoring to 45%, respectively. Transtelephonic ECG and serial 7-day Holter were equally effective to objectively determine long-term success and to detect asymptomatic patients. [source] Mechanism of Propensity to Atrial Fibrillation in Patients Undergoing Isthmus Ablation for Typical Atrial FlutterJOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, Issue 2 2005HEMANTH RAMANNA M.D. Background: Patients undergoing isthmus ablation for atrial flutter (AFL) may reveal postablation atrial fibrillation (AF). The electrophysiological mechanism is unclear. In patients with idiopathic AF, enhanced spatial dispersion of right atrial refractoriness was the substrate for the initiation of AF. We hypothesize that dispersion of right atrial refractoriness in patients undergoing AFL ablation is the major cause of postablation AF. Methods: Consecutive patients (n = 42) undergoing isthmus ablation for typical AFL were included. Twelve right atrial unipolar electrograms were recorded. Inducibility of AF was assessed by a pacing protocol, starting with one extrastimulus, followed by more aggressive pacing until AF was induced. Mean fibrillatory intervals were used to assess local refractoriness of each recording site. Spatial dispersion of right atrial refractoriness was calculated as the coefficient of dispersion (CD-value: standard deviation of the mean of all local mean fibrillatory intervals as a percentage of the overall mean fibrillatory interval). A CD-value of 3.0 or less was defined as normal, whereas CD-value greater than 3.0 was considered enhanced dispersion. PES and refractoriness analysis were followed by isthmus ablation. Results: Of the 42 patients, 29 had CD-value of 3.0 or less. In these 29 patients, AF was induced with 1 extrastimulus in only 1 patient, with 2 extrastimuli in 4 patients and burst pacing was required to induce AF in 24 of these 29 patients. Prior to the procedure, 5 of 29 patients had AF episodes, after ablation 6 of 29 patients. Of the 42 patients, 13 had CD-value greater than 3.0, AF was induced with a single extrastimulus in 11 patients, with 2 extrastimuli in the remaining 2 patients. Of the 13 patients, 11 had AF episodes both before and after ablation (P < 0.001). Conclusion: Enhanced spatial dispersion of right atrial refractoriness may be the substrate for propensity to AF in patients with AFL. The substrate was associated with enhanced inducibility of atrial fibrillation. [source] Inhibitors of the Na+/H+ Exchanger Cannot Prevent Atrial Electrical Remodeling in the GoatJOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, Issue 4 2004YURI BLAAUW M.D. Introduction: It has been suggested that blockade of the Na+/H+ exchanger (NHE1) can prevent atrial fibrillation (AF)-induced electrical remodeling and the development of AF. Methods and Results: AF was maintained by burst pacing in 10 chronically instrumented conscious goats. Intravenous and oral dosages of two NHE1 blockers (EMD87580 and EMD125021) resulted in plasma levels several magnitudes higher than required for effective NHE1 blockade. Shortening of atrial refractoriness immediately after 5 minutes of AF was not prevented by NHE1 blockade. In remodeled atria, increasing dosages of EMD87580 and EMD125021 did not reverse shortening of the atrial refractory period or reduce the duration of AF episodes. The cycle length during persistent AF also was not affected. Oral pretreatment with EMD87580 (8 mg/kg bid) starting 3 days before AF could not prevent electrical remodeling. After 24 and 48 hours of remodeling, the duration of AF paroxysms was 47 ± 32 seconds and 135 ± 63 seconds compared to 56 ± 17 seconds and 136 ± 52 seconds in placebo-treated animals (P > 0.8), respectively. Conclusion: In the goat model of AF, the Na+/H+ exchanger inhibitors EMD87580 and EMD125021 did not prevent or revert AF-induced electrical remodeling. This indicates that activation of the Na+/H+ exchanger is not involved in the intracellular pathways of electrical remodeling. This does not support the suggestion that blockers of the Na+/H+ exchanger may be beneficial for prevention and treatment of AF. (J Cardiovasc Electrophysiol, Vol. 15, pp. 440-446, April 2004) [source] Do Patients Accept Implantable Atrial Defibrillation Therapy?JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, Issue 3 2004Results from the Patient Atrial Shock Survey of Acceptance, Tolerance (PASSAT) Study Introduction: The Medtronic Jewel AF 7250 is an implantable cardioverter defibrillator with atrial and ventricular therapies (ICD-AT). The ICD-AT is effective in managing atrial tachyarrhythmias (atrial fibrillation [AF]), but patient acceptance remains an issue. This aim of this study was to measure ICD-AT acceptance. Methods and Results: ICD-AT acceptance was evaluated in 96 patients enrolled in the "Jewel AF-AF-Only Study" for ,3 months of follow-up (mean 19 months). Patients were mostly men (72%; age 65 ± 12 years). Clinical data and a written survey (75% response rate) were used to quantify demographics, AF frequency and symptoms, atrial defibrillation therapy, quality of life (QOL), psychosocial distress, and ICD-AT therapy acceptance. From implant to survey, AF symptom and severity scores decreased by 18% (P , 0.05), and QOL (SF-36) scores increased by 15% to 50% (P , 0.05). ICD-AT therapy acceptance was high, with 71.3% of patients scoring in the 75th percentile on the Florida Patient Acceptance Survey. ICD-AT acceptance was correlated with the Physical Component Scale and Mental Health Component Scale scores of the SF-36 (r = 0.28 and 0.35, respectively). ICD-AT acceptance was negatively correlated with depressive symptomatology (r =,0.59), trait anxiety (r =,0.48), illness intrusiveness (r =,0.55), and AF symptom and severity scores (r =,0.26). ICD-AT acceptance did not correlate with preimplant cardioversions, number of atrial shocks, AF episodes detected by the device, or device implant duration. Conclusion: Most patients accepted ICD-AT therapy. Patients were more likely to accept ICD-AT if they had less psychosocial distress, greater QOL, and lower AF symptom burden. (J Cardiovasc Electrophysiol, Vol. 15, pp. 286-291, March 2004) [source] Effects of Continuous and Triggered Atrial Overdrive Pacing on Paroxysmal Atrial Fibrillation in Pacemaker PatientsPACING AND CLINICAL ELECTROPHYSIOLOGY, Issue 8 2008ANDREAS SCHUCHERT M.D. Background: The aim of the study was to compare the effects of different pacing strategies to prevent paroxysmal atrial fibrillation (AF): triggered atrial overdrive pacing versus the combination of triggered and continuous overdrive pacing. Methods: Patients with an indication for dual-chamber pacing (Selection 9000, Prevent AF; Vitatron B.V., Arnhem, the Netherlands) and a history of paroxysmal AF were randomized to triggered atrial pacing (three pacing functions, "triggered group": PAC SuppressionÔ, Post-PAC ResponseÔ, and Post-Exercise ResponseÔ) or to the combination of continuous (Pace ConditioningÔ) and triggered atrial pacing (four pacing functions, "combined group"). After 3 months, there was a crossover to the other pacemaker setting. Results: In 171 enrolled patients, the median AF burden of the combined group was with 2.1% versus 0.1% in the triggered group (P = 0.014). Fewer AF episodes were observed in the triggered (median: 7) than in the combined group (median: 116; P = 0.016). The combined group had more frequent atrial pacing (median 97%) than the triggered group with 85% (P < 0.001), but ventricular pacing was not significantly different with 95% and 96% in the combined and triggered group, respectively. After the crossover, the AF burden increased in the triggered group to 0.3% and decreased in the combined group to 0.4%. Conclusions: Triggered atrial pacing functions alone resulted in a low AF burden. The additional activation of continuous atrial overdrive pacing increased the percentage of atrial pacing, but had no beneficial effects on the prevention of paroxysmal AF. [source] Time-Domain and Morphological Analysis of the P Wave.PACING AND CLINICAL ELECTROPHYSIOLOGY, Issue 8 2008Part II: Effects of Atrial Pacing on P-Wave Features Background: The aim of this study was to compare time-domain and morphological descriptors of paced and spontaneous P wave in patients prone to atrial fibrillation (AF). Methods: Nineteen patients (nine women, aged 72 ± 10 years) affected by paroxysmal AF and implanted with dual-chamber pacemakers (PM) were studied. Two 5-minute recordings were performed during spontaneous and paced rhythm. Electrocardiogram (ECG) signals were acquired using a 32-lead mapping system. Patients were grouped into two classes: no previous AF and previous AF groups, according to the number of AF episodes in the 6 months before the analysis. Results and Conclusion:During atrial pacing P wave appeared prolonged and morphologically more complex with respect to sinus rhythm. We also found that in patients at lower risk for AF, the atrial pacing changes the atrial activation to a greater extent than in patients at higher risk for AF. Finally, all time-domain and morphological descriptors of the P wave except one succeed in discriminating "no previous AF" and "previous AF" patients in spontaneous rhythm, while no significant differences have been observed during pacing for any parameters. [source] Electrophysiological Differences of the Spontaneous Onset of Paroxysmal and Persistent Atrial FibrillationPACING AND CLINICAL ELECTROPHYSIOLOGY, Issue 3 2007STEFAN WEBER M.D. Background: Information about the spatiotemporal organization of atrial activity at the onset of atrial fibrillation (AF) is still limited. Methods: AF mapping was performed in 30 patients with AF (mean age 53 ± 9 years, 26 males) by deploying a noncontact mapping balloon in the left atrium (LA). Twenty-four patients had paroxysmal AF and six patients had persistent AF. Three types of AF episodes were analyzed: nonsustained AF (lasting , 30 seconds), sustained AF (lasting > 30 seconds, with spontaneous conversion or requiring internal cardioversion and subsequent stable sinus rhythm), and persistent AF episodes (stable sinus rhythm lasting , 1 minute after cardioversion). Results: A total of 101 spontaneous AF onset episodes were analyzed. Analysis of AF onset showed that there was a progressive shortening of the initial cycle lengths from nonsustained episodes to sustained episodes and to persistent AF episodes. There was an earlier and more rapid reduction in the cycle lengths from persistent episodes to sustained episodes and to nonsustained episodes of AF (P < 0.05 for persistent vs sustained and for sustained vs nonsustained episodes). The development of multiwavelet activity and disorganization of conduction occurred earlier in persistent and sustained episodes than in nonsustained AF episodes. LA size was greater in patients with persistent AF episodes compared with patients with sustained or nonsustained AF episodes. Conclusions: Electrophysiological events that develop at the onset of AF seem to be different in different types of AF. A more rapid degeneration into the fibrillatory activity was observed in persistent and sustained AF than in nonsustained AF episodes. [source] Individualized Selection of Pacing Algorithms for the Prevention of Recurrent Atrial Fibrillation: Results from the VIP RegistryPACING AND CLINICAL ELECTROPHYSIOLOGY, Issue 2 2006THORSTEN LEWALTER Objectives: The VIP registry investigated the efficacy of preventive pacing algorithm selection in reducing atrial fibrillation (AF) burden. Background: There are few data identifying which patients might benefit most from which preventive pacing algorithms. Methods: Patients, with at least one documented AF episode and a conventional antibradycardia indication for pacemaker therapy, were enrolled. They received pacemakers with AF diagnostics and four preventive algorithms (Selection and PreventAF series, Vitatron). A 3-month Diagnostic Phase with conventional pacing identified a Substrate Group (>70% of AF episodes with <2 premature atrial contractions [PACs] before AF onset) and a Trigger Group (,70% of AF episodes with <2 PACs before AF onset). This was followed by a 3-month Therapeutic Phase where in the Trigger Group algorithms were enabled aimed at avoiding or preventing a PAC and in the Substrate Group continuous atrial overdrive pacing was enabled. Results: One hundred and twenty-six patients were evaluated. In the Trigger Group (n = 73), there was a statistically significant 28% improvement in AF burden (median AF burden: 2.06 hours/day, Diagnostic Phase vs 1.49 hours/day, Therapy Phase; P = 0.03304 signed-rank test), and reduced PAC activity. There was no significant improvement in AF burden in the Substrate Group (median AF burden: 1.82 hours/day, Diagnostic Phase vs 2.38 hours/day, Therapy Phase; P = 0.12095 signed-rank test), and little change in PAC activity. Conclusions: We identified a subgroup of patients for whom the selection of appropriate pacing algorithms, based on individual diagnostic data, translated into a reduced AF burden. Trigger AF patients were more likely responders to preventive pacing algorithms as a result of PAC suppression. [source] Understanding Atrial Symptom Reports: Objective versus Subjective PredictorsPACING AND CLINICAL ELECTROPHYSIOLOGY, Issue 8 2005SAMUEL F. SEARS Background: Atrial fibrillation (AF) is the most common cardiac arrhythmia and is associated with a variety of symptoms such as dizziness, palpitations, shortness of breath, and other signs of heart failure, which in turn impact quality of life (QOL). Implantable cardioverter defibrillators with atrial therapies (ICDs-ATs) have been shown to reduce AF symptoms and improve QOL in select AF samples. Method: This study examined the strength of relationships between objective (device-detected AF events) versus subjective (emotional symptoms) data and AF symptoms (number) reported as part of the Patient Atrial Shock Survey of Acceptance and Tolerance Study (N = 96, 72% men, M age = 65, SD = 12). Depression and anxiety were assessed via the Center for Epidemiological Studies,Depression Scale and the-State Trait Anxiety Inventory. AF disease burden was measured via a number of device-detected AF episodes and the Atrial Tachyarrhythmia Symptom Severity Scale. Results: Hierarchical multiple regression analysis indicated that negative emotions accounted for a significant 13.2% of unique variance in AF symptom score (F change (1, 54) = 9.625, P = 0.003). On the other hand, the number of device-detected AF episodes accounted for non-significant 8.2% of unique variance in the AF symptom score (P = 0.167). The full model explained 25.7% of the variance in AF symptom score (F(6, 54) = 3.110, P = 0.011). Specifically, greater number of treated AF episodes (,= 0.251, P = 0.043) and higher levels of negative emotions (,= 0.369, P = 0.003) predicted greater number of reported AF symptoms. Conclusion: Therefore, psychological distress may be a significant confounding factor affecting patient's report of AF symptoms rather than the actual experience of recurrent AF episodes. [source] Pulmonary Vein Internal Electrical Activity Does Not Contribute to the Maintenance of Atrial FibrillationPACING AND CLINICAL ELECTROPHYSIOLOGY, Issue 6 2003GJIN NDREPEPA Whether the electrical activity generated in the pulmonary veins (PVs) during atrial fibrillation (AF) contributes to the maintenance of arrhythmia is not known. The study population consisted of 22 patients (mean age 58 ± 9.5 years, 16 men) with persistent (12 patients) or intermittent (10 patients) AF. Mapping of the left atrium (LA) was performed with a 64-electrode basket catheter. PVs were mapped simultaneously with the LA with a quadripolar catheter. PV were defined as arrhythmogenic (if frequent ectopic activity induced AF) or nonarrhythmogenic (if no ectopic activity was observed during the procedure). AF cycle lengths in arrhythmogenic and nonarrhythmogenic PV were 130 ± 50 ms and 152 ± 42 ms, respectively(P < 0.001). Both were significantly longer than simultaneous AF activity recorded from the posterior wall of the LA(116 ± 49 ms, P < 0.001). AF cycle lengths in arrhythmogenic PVs as compared to nonarrhythmogenic PVs were: right superior PV 125 ± 49 ms versus 148 ± 51 ms ; left superior PV 140 ± 52 ms versus 161 ± 30 ms ; left inferior PV 127 ± 48 ms versus 147 ± 45 ms ; and right inferior PV 129 ± 38 versus 152 ± 44 ms (P < 0.001for all four comparisons). AF activity in the PV was more organized than in the posterior wall of the LA and the veins were activated in a proximal-to-distal direction during sustained AF episodes. In patients with AF not related to rheumatic heart disease, the posterior wall of the LA has faster activity than the PVs. The AF activity generated inside the PV during sustained AF episodes originates from the posterior wall of the LA rather than from focal firing. (PACE 2003; 26:1356,1362) [source] |