Home About us Contact | |||
ECG Data (ecg + data)
Selected AbstractsPrognostic Value of 12-Lead Electrocardiogram During Dobutamine Stress EchocardiographyECHOCARDIOGRAPHY, Issue 5 2000Milind R. Dhond M.D. The aim of this study was to assess the prognostic value of the 12-lead electrocardiogram (ECG) obtained during dobutamine stress echocardiography (DSE) in predicting subsequent cardiac events. We retrospectively analyzed 345 patients undergoing DSE in 1992,1994 and selected those patients with negative echo results for ischemia. Of the 200 patients with negative DSE results, a separate analysis of their ECG data was performed with results reported as either positive, negative, or nondiagnostic for ischemia. Follow-up was performed through a physician chart review and direct telephone contact. Event rates were determined for hard (myocardial infarction or cardiac death) and soft (hospitalization for angina and/or congestive heart failure, coronary angioplasty, or coronary artery bypass graft surgery) cardiac events occurring after the negative DSE for up to 6 years after the test. Death was also determined by referencing the patients' data with mortality data available on the Internet. There were 143 patients with ECG data reported as negative and 40 patients with ECG data reported as positive for ischemia. The hard and soft event rates were 1.5% and 9% per patient per year in the ECG negative group and 2% and 11% in the ECG positive group. There were no statistical differences in event rates between the two groups during the 5-year follow-up period. Our results suggest that the ECG result obtained during DSE does not confer any incremental prognostic value over the echo result. [source] Cardiac function and antiepileptic drug treatment in the elderly: A comparison between lamotrigine and sustained-release carbamazepineEPILEPSIA, Issue 8 2009Erik Saetre Summary Purpose:, To investigate the comparative effects of carbamazepine (CBZ) and lamotrigine (LTG) on electrocardiography (ECG) parameters in elderly patients with newly diagnosed epilepsy. Methods:,, The study was conducted in the Norwegian subcohort (n = 108) of an international randomized double-blind 40-week trial, which compared the efficacy and tolerability of LTG and sustained-release CBZ in patients aged 65 and older with newly diagnosed epilepsy. Target maintenance doses were 400 mg/day for CBZ and 100 mg/day for LTG, with adjustments based on clinical response. Patients with significant unpaced atrioventricular (AV) conduction defect were excluded. Resting 12-lead ECG recordings were made under standardized conditions at pretreatment (baseline) and at the 40-week study visit (treatment visit). Changes in QRS interval (primary endpoint), heart rate (HR), PQ, and QTc (HR-corrected QT) intervals were assessed and compared between groups. Results:, Of the 108 patients randomized, 33 discontinued prematurely because of adverse events (n = 24, none of which was cardiac) or other reasons (n = 9), and 15 were nonevaluable due to incomplete ECG data. None of the assessed ECG parameters differed significantly between groups at baseline. No significant ECG changes were recorded between baseline and treatment visit for QRS duration and QTc intervals, whereas HR fell and PQ intervals increased slightly on both treatments. However, there were no differences between groups in changes from baseline to treatment visit. There were no significant relationships between individual ECG changes and serum drug concentrations, except for QTc intervals, which decreased slightly with increasing CBZ concentrations. The proportion of patients with ECG parameters outside the normal range at treatment visit was similar to that recorded at baseline. Discussion:, Clinically significant ECG changes are not common during treatment with CBZ or LTG in elderly patients with no preexisting significant AV conduction defects. [source] Repolarization Abnormality in Idiopathic Ventricular Fibrillation:JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, Issue 1 2004Assessment Using 24-Hour QT-RR, QaT-RR Relationships Introduction: We evaluated the characteristics of QT-RR and QaT (apex of T wave)-RR relationships in patients with idiopathic ventricular fibrillation (IVF) compared with control subjects. We hypothesized that IVF patients have unique repolarization dynamics related to a reduced fast Na current and a prominent transient outward current. Methods and Results: The study group consisted of 9 men (age 47 ± 10 years) with IVF (6 with Brugada type and 3 with non-Brugada type) who had experienced nocturnal episodes of VF. The control group consisted of 28 healthy age-matched men (age 44 ± 12 years). The relationships between QT and RR intervals and between QaT and RR intervals were analyzed from 24-hour Holter ECG data using an automatic measurement system. Both QT and QaT at RR intervals of 0.6, 1.0, and 1.2 seconds were determined from QT-RR and QaT-RR linear regression lines. Both QT-RR and QaT-RR slopes were lower in the IVF group than in the control group (QT-RR: 0.092 ± 0.023 vs 0.137 ± 0.031, P < 0.001; QaT-RR: 0.109 ± 0.025 vs 0.153 ± 0.028, P < 0.001). QT at an RR interval of 0.6 second did not differ between two groups, but QT at RR intervals of either 1.0 or 1.2 seconds was significantly shorter in the IVF group than in the control group (RR 1.0 s: 0.384 ± 0.018 vs 0.399 ± 0.017, P < 0.05; RR 1.2 s: 0.402 ± 0.019 vs 0.426 ± 0.020, P < 0.01). QaT at RR intervals of either 1.0 or 1.2 seconds also was shorter in the IVF group (RR 1.0 s: 0.289 ± 0.022 vs 0.312 ± 0.021, P < 0.01; RR 1.2 s: 0.311 ± 0.024 vs 0.343 ± 0.024, P < 0.01). In four patients, oral administration of disopyramide (300 mg/day) was effective in suppressing VF episodes and increased slopes of QT-RR and QaT-RR relationships. Conclusion: IVF patients had lower slopes of QT-RR and QaT-RR regression lines and impaired prolongation of QT and QaT at longer RR intervals compared with control subjects. These unique repolarization dynamics may be related to the frequent occurrence of VF episodes at night. (J Cardiovasc Electrophysiol, Vol. 15, pp. 59-63, January 2004) [source] All is Not Lost: Utilizing Continuous Remote ILR Monitoring to Diagnose SyncopePACING AND CLINICAL ELECTROPHYSIOLOGY, Issue 6 2010PAUL S. G. HONG M.D. A 63-year-old man with frequent unexplained syncope was implanted with a second generation remotely monitored implantable loop recorder for continuous electrocardiogram (ECG) monitoring. He had a subsequent syncopal episode and despite accidental destruction of his patient activator, vital ECG data from the event were transmitted wirelessly, enabling a cardiac arrhythmia to be excluded. This case highlights the benefit of remote monitoring in syncope assessment, as well as a transmission system that ensures prompt analysis of the ECG data and therefore rapid optimal patient management. (PACE 2010; 33:763,765) [source] Electrocardiographic Activity before Onset of Postoperative Atrial Fibrillation in Cardiac Surgery PatientsPACING AND CLINICAL ELECTROPHYSIOLOGY, Issue 11 2008MIRELA OVREIU Ph.D. Background:Electrocardiographic (ECG) characteristics were analyzed in postoperative cardiac surgery patients in an attempt to predict development of new-onset postoperative atrial fibrillation (AF). Methods:Nineteen ECG characteristics were analyzed using computer-based algorithms. The parameters were retrospectively analyzed from ECG signals recorded in postoperative cardiac surgery patients while they were in the cardiovascular intensive care unit (CVICU) at our institution. ECG data from 99 patients (of whom 43 developed postoperative AF) were analyzed. A bootstrap variable selection procedure was applied to select the most important ECG parameters, and a multivariable logistic regression model was developed to classify patients who did and did not develop AF. Results:Premature atrial activity (PAC) was greater in AF patients (P < 0.01). Certain heart rate variability (HRV) and turbulence parameters also differed in patients who did and did not develop AF. In contrast, P-wave morphology was similar in patients with and without AF. Receiver operating curve (ROC) analysis applied to the model produced a C-statistic of 0.904. The model thus correctly classified AF patients with more than a 90% sensitivity and a 70% specificity. Conclusion:Among the 19 ECG parameters analyzed, PAC activity, frequency-domain HRV, and heart rate turbulence parameters were the best discriminators for postoperative AF. [source] Correlation of Electrical and Mechanical Reverse Remodeling after Cardiac Resynchronization TherapyANNALS OF NONINVASIVE ELECTROCARDIOLOGY, Issue 2 2009Swapna Kamireddy M.D. Background: Cardiac resynchronization therapy (CRT) improves clinical outcome in many patients with refractory heart failure (HF). This study examined whether CRT is associated with reverse electrical remodeling by surface electrocardiogram (ECG). Methods: Consecutive CRT recipients at the University of Pittsburgh Medical Center with >90 days of follow-up were included in this analysis. ECG data were abstracted from medical records. Subjects with a relative increase of ,15% in left ventricular ejection fraction (LVEF) after CRT were considered responders. Results: A total of 113 patients (age 69 ± 11 years, men 70%, white 92%) were followed for a mean duration of 407 ± 290 (92,1439) days. Overall, LVEF increased after CRT (29 ± 13% vs 24 ± 9%; P < 0.01) and 50% of patients were responders. The mean native QRS interval among responders was higher than in nonresponders (163 ± 32 ms vs 148 ± 29 ms; P < 0.01). More than 3 months after CRT, there was no change in the paced QRS duration compared to baseline. Paced QRS duration, however, decreased among responders and increased among nonresponders and was significantly different by response status (P < 0.001). There was a significant correlation between increase in LVEF and decrease in paced QRS width in the overall population (r =,0.3; P < 0.01). Conclusions: Among responders to CRT, the paced QRS width decreases significantly, whereas it increases among nonresponders. Given the paced nature of the QRS, the improved conduction probably reflects enhanced cell-to-cell coupling after CRT as opposed to improved conduction within the His-Purkinje system. These findings have significant implications as to the mechanisms of benefit from CRT. [source] Automated QT Analysis That Learns from Cardiologist AnnotationsANNALS OF NONINVASIVE ELECTROCARDIOLOGY, Issue 2009Iain Guy David Strachan Ph.D. Background: Reliable, automated QT analysis would allow the use of all the ECG data recorded during continuous Holter monitoring, rather than just intermittent 10-second ECGs. Methods: BioQT is an automated ECG analysis system based on a Hidden Markov Model, which is trained to segment ECG signals using a database of thousands of annotated waveforms. Each sample of the ECG signal is encoded by its wavelet transform coefficients. BioQT also produces a confidence measure which can be used to identify unreliable segmentations. The automatic generation of templates based on shape descriptors allows an entire 24 hours of QT data to be rapidly reviewed by a human expert, after which the template annotations can automatically be applied to all beats in the recording. Results: The BioQT software has been used to show that drug-related perturbation of the T wave is greater in subjects receiving sotalol than in those receiving moxifloxacin. Chronological dissociation of T-wave morphology changes from the QT prolonging effect of the drug was observed with sotalol. In a definitive QT study, the percentage increase of standard deviation of QTc for the standard manual method with respect to that obtained with BioQT analysis was shown to be 44% and 30% for the placebo and moxifloxacin treatments, respectively. Conclusions: BioQT provides fully automated analysis, with confidence values for self-checking, on very large data sets such as Holter recordings. Automatic templating and expert reannotation of a small number of templates lead to a reduction in the sample size requirements for definitive QT studies. [source] Comparing Methods of Measurement for Detecting Drug-Induced Changes in the QT Interval: Implications for Thoroughly Conducted ECG StudiesANNALS OF NONINVASIVE ELECTROCARDIOLOGY, Issue 2 2004Nkechi E. Azie M.D. Background:,The aim of this study was to compare the reproducibility and sensitivity of four commonly used methods for QT interval assessment when applied to ECG data obtained after infusion of ibutilide. Methods:,Four methods were compared: (1) 12-lead simultaneous ECG (12-SIM), (2) lead II ECG (LEAD II), both measured on a digitizing board, (3) 3-LEAD ECG using a manual tangential method, and (4) a computer-based, proprietary algorithm, 12SLÔ ECG Analysis software (AUT). QT intervals were measured in 10 healthy volunteers at multiple time points during 24 hours at baseline and after single intravenous doses of ibutilide 0.25 and 0.5 mg. Changes in QT interval from baseline were calculated and compared across ECG methods, using Bland,Altman plots. Variability was studied using a mixed linear model. Results:,Baseline QT values differed between methods (range 376,395 ms), mainly based on the number of leads incorporated into the measurement, with LEAD II and 3-LEAD providing the shortest intervals. The 3-LEAD generated the largest QT change from baseline, whereas LEAD II and 12-SIM generated essentially identical result within narrow limits of agreement (0.4 ms mean difference, 95% confidence interval ± 20.5 ms). Variability with AUT (standard deviation 15.8 ms for within-subject values) was clearly larger than with 3-LEAD, LEAD II, and 12-SIM (9.6, 10.0, and 11.3 ms). Conclusion:,This study demonstrated significant differences among four commonly used methods for QT interval measurement after pharmacological prolongation of cardiac repolarization. Observed large differences in variability of measurements will have a substantial impact on the sample size required to detect QT prolongation in the range that is currently advised in regulatory guidance. [source] Novel mobile telemedicine system for real-time transmission of out-of-hospital ECG data for ST-elevation myocardial infarction,CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, Issue 6 2009Yoritaka Otsuka MD Abstract The guidelines recommend routine use of 12-lead electrocardiogram (ECG) and advance notification to the emergency department for patients with ST-elevation myocardial infarction (STEMI). However, transmission of out-of-hospital 12-lead ECG to emergency department is still not widely practiced and ECG interpretation before arrival at the emergency department is not established. We have developed a novel mobile telemedicine system to transmit real-time 12-lead ECG data between moving ambulances and in-hospital physicians in cardiovascular emergency cases. When used, this system immediately identifies patients with STEMI and it is coupled to a centralized system to alert the cardiac catheterization teams to prepare for prompt intervention. This report presents the first case with STEMI who was successfully treated using this novel mobile telemedicine system. © 2009 Wiley-Liss, Inc. [source] |