Home About us Contact | |||
Donor Screening (donor + screening)
Kinds of Donor Screening Selected AbstractsDonor Screening for Human T-Cell Lymphotrophic Virus 1/2: The future Is UncertainAMERICAN JOURNAL OF TRANSPLANTATION, Issue 2 2010A. Humar Screening of organ donors for HTLV-1/2 infection has advantages and disadvantages that must be weighed, and rational decisions will require new evidence. See minireview by Kaul et al on page 207. [source] Donor Screening for Human T-cell Lymphotrophic Virus 1/2: Changing Paradigms for Changing Testing CapacityAMERICAN JOURNAL OF TRANSPLANTATION, Issue 2 2010D. R. Kaul Organ Procurement and Transplant Network (OPTN) policy currently requires the testing of all potential organ donors for human T-cell lymphotrophic virus (HTLV)-1/2. Most Organ Procurement Organizations (OPO) use the Abbott HTLV-I/HTLV-II Enzyme Immunoassay (EIA). This assay will no longer be manufactured after December 31, 2009; the only commercially available FDA-licensed assay will be the Abbott PRISM HTLV-I/II assay which poses many challenges to OPO use for organ donor screening. As a result, screening donors for HTLV-1/2 in a timely manner pretransplant after December 31, 2009 will be challenging. The true incidence of HTLV-1 in United States (U.S.) organ donors is not well described but appears to be low (,0.03,0.5%). HTLV-1 is associated with malignancy and neurological disease; HTLV-2 has not been convincingly associated with disease in humans. Donors that are HTLV-1/2 seropositive are infrequently used despite most results being either false positive or resulting from HTLV-2 infection. There is urgent need to encourage the development of assays, instruments and platforms optimized for organ donors that can be used to screen for transmissible disease in donors; these must have appropriate sensitivity and specificity to identify all infections while minimizing organ loss through false positive testing. [source] Concentrate safety and efficacyHAEMOPHILIA, Issue 3 2002C. K. KASPER Safety from transmission of infections through plasma-derived clotting factor concentrates is assured by improved donor screening, serological testing of individual donations and direct viral testing of small plasma pools. Modern viral-inactivation techniques are highly effective. Recombinant concentrates stabilized in human albumin are being superaeded by those with other stabilizers. Recently reported discrepancies between estimates of concentrate potency from in vitro assays versus in vivo recovery, depending upon type of assay and reference standard used, are not fully resolved. [source] Viral safety of a pasteurized, monoclonal antibody-purified factor VIII concentrate in previously untreated haemophilia A patientsHAEMOPHILIA, Issue 2 2001C. S. Philipp The efficacy and viral safety of a pasteurized, immunoaffinity-purified procoagulant factor VIII protein (FVIII:C; Monoclate-P) was studied in two multicentre, prospective, open-label trials in 30 previously untreated patients, 18 with severe (< 1% FVIII:C activity), and 12 with moderate (1% to 5% FVIII:C activity) haemophilia A. Clinical assessments, performed at screening and regularly thereafter for 6 to > 24 months (maximum 34 months), showed that none of 24 assessable patients acquired illnesses consistent with monitored transfusion-transmissible diseases. No patients acquired hepatitis B surface antigen, or antibodies against hepatitis B core antigen, hepatitis C, or human immunodeficiency virus. Likewise, no patients acquired treatment-related hepatitis A antibodies or sustained elevations of alanine aminotransferase levels. The safety profile for Monoclate-P is brought about by a multi-step safety system that incorporates viral inactivation (through a combination of immunoaffinity chromatography and pasteurization) plus donor screening, plasma testing, and quality assurance. The inhibitor development rate (13% low titre, 10% high titre) was similar to that reported in the literature for other FVIII concentrates (24% to 52%). The most frequently reported adverse events were related to typical infant and childhood diseases. Monoclate-P was effective in all patients treated according to protocol, except in two, who developed inhibitors. [source] Comparison of haemoglobinometry by WHO Haemoglobin Colour Scale and copper sulphate against haemiglobincyanide reference methodINTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, Issue 4 2004I. S. Timan Summary Although estimation of haemoglobin is essential for diagnosing anaemia and assessing its severity, many health centres in developing countries do not have the facilities for haemoglobinometry. The WHO Haemoglobin Colour Scale (HCS) method is a simple and inexpensive clinical device that was recently developed in order to diagnose anaemia in such centres. In Indonesia, the copper sulphate specific gravity method is used for blood donor screening and also in primary health clinics in the rural and remote areas. In this study, the HCS method is compared with the copper sulphate method and with an earlier paper scale, the Tallquist method, against the standard haemiglobincyanide spectrophotometric method. The HCS method showed an acceptable level of precision and accuracy for use as a reliable screening tool to diagnose anaemia in patients and also for blood donor screening. [source] Comparison of different methods of bacterial detection in blood componentsISBT SCIENCE SERIES: THE INTERNATIONAL JOURNAL OF INTRACELLULAR TRANSPORT, Issue 1 2009M. Schmidt Background, Over the last two decades, the residual risk of acquiring a transfusion-transmitted viral infection has been reduced to less than 1 : 1 000 000 via improvements in different techniques (e.g. donor selection, leuco-depletion, introduction of 3rd or 4th generation enzyme-linked immunosorbent assays and mini-pool nucleic acid testing (MP-NAT). In contrast, the risk for transfusion-associated bacterial infections has remained fairly stable, and is estimated to be in a range between 1 : 2000 and 1 : 3000. Platelets are at an especially higher risk for bacterial contamination, because they are stored at room temperature, which provides good culture conditions for a broad range of bacterial strains. To improve bacterial safety of blood products, different detection systems have been developed that can be divided into culture systems like BacT/ALERT or Pall eBDS, rapid detection systems like NAT systems, immunoassays and systems based on the FACS technique. Culture systems are used for routine bacterial screening of platelets in many countries, whereas rapid detection systems so far are mainly used in experimental spiking studies. Nevertheless, pathogen-reduction systems are currently available for platelet concentrates and plasma, and are under investigation for erythrocytes. Methods, In this review, the functional principles of the different assays are described and discussed with regard to their analytical sensitivity, analytical specificity, diagnostic sensitivity, diagnostic specificity and clinical efficiency. The detection methods were clustered into three groups: (i) detection systems currently used for routine screening of blood products, (ii) experimental detection systems ready to use for routine screening of blood products, and (iii) new experimental detection systems that need to be investigated in additional spiking studies and clinical trials. Results, A recent International Society of Blood Transfusion international forum reported on bacterial detection methods in 12 countries. Eight countries have implemented BacT/ALERT into blood donor screening, whereas in three countries only quality controls were done by culture methods. In one country, shelf-life was reduced to 3 days, so no bacterial screening was implemented. Screening data with culture methods can be used to investigate the prevalence of bacterial contamination in platelets. Differing results between the countries could be explained by different test definitions and different test strategies. Nevertheless, false-negative results causing severe transfusion-related septic reactions have been reported all over the world due to a residual risk of sample errors. Rapid screening systems NAT and FACS assays have improved over the last few years and are now ready to be implemented in routine screening. Non-specific amplification in NAT can be prevented by pre-treatment with Sau3AI, filtration of NAT reagents, or reduction of the number of polymerase chain reaction cycles. FACS systems offer easy fully automated handling and a handling time of only 5 min, which could be an option for re-testing day-5 platelets. New screening approaches like immunoassays, detection of bacterial adenosine triphosphate, or detection of esterase activity need to be investigated in additional studies. Conclusion, Bacterial screening of blood products, especially platelets, can be done with a broad range of technologies. The ideal system should be able to detect one colony-forming unit per blood bag without a delay in the release process. Currently, we are far away from such an ideal screening system. Nevertheless, pathogen-inactivation systems are available, but a system for all blood components will not be expected in the next few years. Therefore, existing culture systems should be complemented by rapid systems like NAT or FACS especially for day-5 platelets. [source] Pathogen-reduction methods: advantages and limitsISBT SCIENCE SERIES: THE INTERNATIONAL JOURNAL OF INTRACELLULAR TRANSPORT, Issue 1 2009H. G. Klein Pathogen-reduction (inactivation) provides a proactive approach to reducing transfusion-transmitted infection. Pathogen-reduction technologies have been successfully implemented by plasma fractionators resulting in no transmission of human immunodeficiency, hepatitis C, or hepatitis B viruses by US-licensed plasma derivatives since 1987. Fractionation technologies cannot be used to treat cellular blood components. Although blood donor screening, deferral and disease testing have drastically reduced the incidence of transfusion-transmitted diseases, the threat of new or re-emerging pathogens remains. Of particular concern is the silent emergence of a new agent with a prolonged latent period in which asymptomatic infected carriers would donate and spread infection. The ultimate goal of pathogen-inactivation is to reduce transmission of potential pathogens without significantly compromising the therapeutic efficacy of the cellular and protein constituents of blood. The acceptable technology must not introduce toxicities into the blood supply nor result in neoantigen formation and subsequent antibody production. Several promising pathogen-inactivation technologies are being developed and tested, and others are currently in use, but all of them have limits. Pathogen-reduction promises an additional ,layer of protection' from infectious agents and has the potential to impact the safety of blood transfusions worldwide. [source] Pathogen inactivation technology: cleansing the blood supplyJOURNAL OF INTERNAL MEDICINE, Issue 3 2005H. G. KLEIN Abstract., Klein HG (The Johns Hopkins School of Medicine and Warren G. Magnuson Clinical Center, National Institutes of Health, Bethesda, MD, USA). Pathogen inactivation technology: cleansing the blood supply (Review). J Intern Med 2005; 257: 224,237. The calculated residual infectious risk of HIV, hepatitis B virus (HBV) and hepatitis C virus (HCV) from blood transfusion is extremely low. However, the risk of bacterial contamination remains and a variety of other agents including emerging viruses, protozoa and tick-borne agents threaten blood supplies and undermine public confidence in blood safety. Traditional methods of donor screening and testing have limited ability to further reduce disease transmission and cannot prevent an emerging infectious agent from entering the blood supply. Pathogen inactivation technologies have all but eliminated the infectious risks of plasma-derived protein fractions, but as yet no technique has proved sufficiently safe and effective for traditional blood components. Half-way technologies can reduce the risk of pathogen transmission from fresh frozen plasma and cryoprecipitate. Traditional methods of mechanical removal such as washing and filtration have limited success in reducing the risk of cell-associated agents, but methods aimed at sterilizing blood have either proved toxic to the cells or to the recipients of blood components. Several promising methods that target pathogen nucleic acid have recently entered clinical testing. [source] Evaluation of a new, fully automated immunoassay for detection of HTLV-I and HTLV-II antibodiesJOURNAL OF MEDICAL VIROLOGY, Issue 3 2008Xiaoxing Qiu Abstract Screening blood donations for human T-lymphotropic virus types I and II (HTLV-I/II) continues to be important in protecting the safety of blood products and controlling the global spread of these retroviruses. We have developed a fully automated, third generation chemiluminescent immunoassay, ARCHITECT rHTLV-I/II, for detection of antibodies to HTLV-I/II. The assay utilizes recombinant proteins and synthetic peptides and is configured in a double antigen sandwich assay format. Specificity of the assay was 99.98% (9,254/9,256, 95% CI,=,99.92,100%) with the negative specimens from the general population including blood donors, hospital patients and pregnant women from the US, Japan and Nicaragua. The assay demonstrated 100% sensitivity by detecting 498 specimens from individuals infected with HTLV-I (n,=,385) and HTLV-II (n,=,113). ARCHITECT rHTLV-I/II results were in complete agreement with the Murex HTLV-I/II reference assay and 99.7% agreement with the Genelabs HTLV Blot 2.4 confirmatory assay. Analytical sensitivity of the assay was equivalent to Murex HTLV-I/II assay based on end point dilutions. Furthermore, using a panel of 397 specimens from Japan, the ARCHITECT rHTLV-I/II assay exhibited distinct discrimination between the antibody negative (Delta Value,=,,7.6) and positive (Delta Value,=,7.6) populations. Based on the excellent specificity and sensitivity, the new ARCHITECT rHTLV-I/II assay should be an effective test for the diagnosis of HTLV-I/II infection and also for blood donor screening. J. Med. Virol. 80:484,493, 2008. © 2008 Wiley-Liss, Inc. [source] Donor Screening for Human T-cell Lymphotrophic Virus 1/2: Changing Paradigms for Changing Testing CapacityAMERICAN JOURNAL OF TRANSPLANTATION, Issue 2 2010D. R. Kaul Organ Procurement and Transplant Network (OPTN) policy currently requires the testing of all potential organ donors for human T-cell lymphotrophic virus (HTLV)-1/2. Most Organ Procurement Organizations (OPO) use the Abbott HTLV-I/HTLV-II Enzyme Immunoassay (EIA). This assay will no longer be manufactured after December 31, 2009; the only commercially available FDA-licensed assay will be the Abbott PRISM HTLV-I/II assay which poses many challenges to OPO use for organ donor screening. As a result, screening donors for HTLV-1/2 in a timely manner pretransplant after December 31, 2009 will be challenging. The true incidence of HTLV-1 in United States (U.S.) organ donors is not well described but appears to be low (,0.03,0.5%). HTLV-1 is associated with malignancy and neurological disease; HTLV-2 has not been convincingly associated with disease in humans. Donors that are HTLV-1/2 seropositive are infrequently used despite most results being either false positive or resulting from HTLV-2 infection. There is urgent need to encourage the development of assays, instruments and platforms optimized for organ donors that can be used to screen for transmissible disease in donors; these must have appropriate sensitivity and specificity to identify all infections while minimizing organ loss through false positive testing. [source] |